scholarly journals Origins of Dry Air in the Tropics and Subtropics

2007 ◽  
Vol 20 (12) ◽  
pp. 2745-2759 ◽  
Author(s):  
Piero Cau ◽  
John Methven ◽  
Brian Hoskins

Abstract The humidity in the dry regions of the tropical and subtropical troposphere has a major impact on the ability of the atmosphere to radiate heat to space. The water vapor content in these regions is determined by their “origins,” here defined as the last condensation event following air masses. Trajectory simulations are used to investigate such origins using the 40-yr European Centre for Medium-Range Weather Forecasts Re-Analysis (ERA-40) data for January 1993. It is shown that 96% of air parcels experience condensation within 24 days and most of the remaining 4% originate in the stratosphere. Dry air masses are shown to experience a net pressure increase since last condensation, which is uniform with latitude, while the median time taken for descent is 5 days into the subtropics but exceeds 16 days into the equatorial lower troposphere. The associated rate of decrease in potential temperature is consistent with radiative cooling. The relationship between the drier regions in the Tropics and subtropics and the geographical localization of their origin is investigated. Four transport processes are identified to explain these relationships.

2014 ◽  
Vol 7 (2) ◽  
pp. 1001-1025
Author(s):  
L. L. Smith ◽  
J. C. Gille

Abstract. Global satellite observations from the EOS Aura spacecraft's High Resolution Dynamics Limb Sounder (HIRDLS) of temperature and geopotential height (GPH) are discussed. The accuracy, resolution and precision of the HIRDLS version 7 algorithms are assessed and data screening recommendations are made. Comparisons with GPH from observations, reanalyses and models including European Center for Medium-Range Weather Forecasts Interim Reanalysis (ERA-Interim), National Centers for Environmental Prediction/National Center for Atmospheric Research (NCEP/NCAR) Reanalysis, Goddard Earth Observing System Model (GEOS) version 5, and EOS Aura Microwave Limb Sounder (MLS) illustrate the HIRDLS GPH have a precision ranging from 2 m to 30 m and an accuracy of ±100 m. Comparisons indicate HIRDLS GPH may have a slight low bias in the tropics and a slight high bias at high latitudes. Geostrophic winds computed with HIRDLS GPH qualitatively agree with winds from other data sources including ERA-Interim, NCEP and GEOS-5.


2019 ◽  
Vol 19 (23) ◽  
pp. 15049-15071
Author(s):  
Heiko Bozem ◽  
Peter Hoor ◽  
Daniel Kunkel ◽  
Franziska Köllner ◽  
Johannes Schneider ◽  
...  

Abstract. The springtime composition of the Arctic lower troposphere is to a large extent controlled by the transport of midlatitude air masses into the Arctic. In contrast, precipitation and natural sources play the most important role during summer. Within the Arctic region sloping isentropes create a barrier to horizontal transport, known as the polar dome. The polar dome varies in space and time and exhibits a strong influence on the transport of air masses from midlatitudes, enhancing transport during winter and inhibiting transport during summer. We analyzed aircraft-based trace gas measurements in the Arctic from two NETCARE airborne field campaigns (July 2014 and April 2015) with the Alfred Wegener Institute Polar 6 aircraft, covering an area from Spitsbergen to Alaska (134 to 17∘ W and 68 to 83∘ N). Using these data we characterized the transport regimes of midlatitude air masses traveling to the high Arctic based on CO and CO2 measurements as well as kinematic 10 d back trajectories. We found that dynamical isolation of the high Arctic lower troposphere leads to gradients of chemical tracers reflecting different local chemical lifetimes, sources, and sinks. In particular, gradients of CO and CO2 allowed for a trace-gas-based definition of the polar dome boundary for the two measurement periods, which showed pronounced seasonal differences. Rather than a sharp boundary, we derived a transition zone from both campaigns. In July 2014 the polar dome boundary was at 73.5∘ N latitude and 299–303.5 K potential temperature. During April 2015 the polar dome boundary was on average located at 66–68.5∘ N and 283.5–287.5 K. Tracer–tracer scatter plots confirm different air mass properties inside and outside the polar dome in both spring and summer. Further, we explored the processes controlling the recent transport history of air masses within and outside the polar dome. Air masses within the springtime polar dome mainly experienced diabatic cooling while traveling over cold surfaces. In contrast, air masses in the summertime polar dome were diabatically heated due to insolation. During both seasons air masses outside the polar dome slowly descended into the Arctic lower troposphere from above through radiative cooling. Ascent to the middle and upper troposphere mainly took place outside the Arctic, followed by a northward motion. Air masses inside and outside the polar dome were also distinguished by different chemical compositions of both trace gases and aerosol particles. We found that the fraction of amine-containing particles, originating from Arctic marine biogenic sources, is enhanced inside the polar dome. In contrast, concentrations of refractory black carbon are highest outside the polar dome, indicating remote pollution sources. Synoptic-scale weather systems frequently disturb the transport barrier formed by the polar dome and foster exchange between air masses from midlatitudes and polar regions. During the second phase of the NETCARE 2014 measurements a pronounced low-pressure system south of Resolute Bay brought inflow from southern latitudes, which pushed the polar dome northward and significantly affected trace gas mixing ratios in the measurement region. Mean CO mixing ratios increased from 77.9±2.5 to 84.9±4.7 ppbv between these two regimes. At the same time CO2 mixing ratios significantly decreased from 398.16 ± 1.01 to 393.81 ± 2.25 ppmv. Our results demonstrate the utility of applying a tracer-based diagnostic to determine the polar dome boundary for interpreting observations of atmospheric composition in the context of transport history.


2016 ◽  
Vol 16 (13) ◽  
pp. 8389-8403 ◽  
Author(s):  
Jörn Ungermann ◽  
Mandfred Ern ◽  
Martin Kaufmann ◽  
Rolf Müller ◽  
Reinhold Spang ◽  
...  

Abstract. This paper presents an analysis of trace gases in the Asian summer monsoon (ASM) region on the basis of observations by the CRISTA infrared limb sounder taken in low-earth orbit in August 1997. The spatially highly resolved measurements of peroxyacetyl nitrate (PAN) and O3 allow a detailed analysis of an eddy-shedding event of the ASM anticyclone. We identify enhanced PAN volume mixing ratios (VMRs) within the main anticyclone and within the eddy, which are suitable as a tracer for polluted air originating in India and China. Plotting the retrieved PAN VMRs against potential vorticity (PV) and potential temperature reveals that the PV value at which the PAN VMRs exhibit the strongest decrease with respect to PV increases with potential temperature. These PV values might be used to identify the extent of the ASM. Using temperature values also derived from CRISTA measurements, we also computed the location of the thermal tropopause according to the WMO criterion and find that it confines the PAN anomaly vertically within the main ASM anticyclone. In contrast, the shed eddy exhibits enhanced PAN VMRs for 1 to 2 km above the thermal tropopause. Using the relationship between PAN as a tropospheric tracer and O3 as a stratospheric tracer to identify mixed air parcels, we further found the anticyclone to contain few such air parcels, whereas the region between the anticyclone and the eddy as well as the eddy itself contains many mixed air parcels. In combination, this implies that while the anticyclone confines polluted air masses well, eddy shedding provides a very rapid horizontal transport pathway of Asian pollution into the extratropical lowermost stratosphere with a timescale of only a few days.


2007 ◽  
Vol 7 (1) ◽  
pp. 107-119 ◽  
Author(s):  
A. Karpechko ◽  
A. Lukyanov ◽  
E. Kyrö ◽  
S. Khaikin ◽  
L. Korshunov ◽  
...  

Abstract. Balloon-borne water vapour measurements during January and February 2004, which were obtained as part of the LAUTLOS campaign at Sodankylä, Finland, 67° N, were used to analyse the water vapour distribution in the wintertime Arctic lowermost stratosphere. A 2.5 km thick layer (or 30 K in the potential temperature scale) above the tropopause is characterized by a significant water vapour variability on a synoptic timescale with values between stratospheric and tropospheric, which is in good agreement with previously reported measurements. A cross-correlation analysis of ozone and water vapour confirms that this layer contains a mixture of stratospheric and tropospheric air masses. Some of the flights sampled laminae of enhanced water vapour above the tropopause. Meteorological analyses and backward trajectory calculations show that these features were related to filaments that had developed along the flanks of cut-off anticyclones, which had been active at this time over the Northern Atlantic. The role of the filaments was however not to transport water vapour from the troposphere to the stratosphere but rather to transport it within the stratosphere away from regions where intensive two-way stratosphere-troposphere exchange (STE) was identified. Intensive STE occurred around cut-off anticyclones in regions of strong winds, where calculations suggest the presence of clear-air turbulence (CAT). Evidences that CAT contributes to the troposphere-to-stratosphere transport (TST) are presented. However, statistically, relation between TST and CAT during the studied period is weak.


2014 ◽  
Vol 7 (8) ◽  
pp. 2775-2785 ◽  
Author(s):  
L. L. Smith ◽  
J. C. Gille

Abstract. The geopotential height (GPH) product created from global observations by the High Resolution Dynamics Limb Sounder (HIRDLS) instrument on NASA's Earth Observing System (EOS) Aura spacecraft is discussed. The accuracy, resolution and precision of the HIRDLS version 7 algorithms are assessed and data screening recommendations are made. Comparisons with GPH from observations, reanalyses and models including European Centre for Medium-Range Weather Forecasts Interim Reanalysis (ERA-Interim), and National Centers for Environmental Prediction/National Center for Atmospheric Research (NCEP/NCAR) Reanalysis illustrate the HIRDLS GPHs have a precision ranging from 2 to 30 m and an accuracy of ±100 m up to 1 hPa. Comparisons indicate HIRDLS GPH may have a slight low bias in the tropics and a slight high bias at high latitudes. Geostrophic winds computed with HIRDLS GPH qualitatively agree with winds from other data sources including ERA-Interim.


2009 ◽  
Vol 137 (1) ◽  
pp. 51-67 ◽  
Author(s):  
Kay L. Shelton ◽  
John Molinari

Abstract Hurricane Claudette developed from a weak vortex in 6 h as deep convection shifted from downshear into the vortex center, despite ambient vertical wind shear exceeding 10 m s−1. Six hours later it weakened to a tropical storm, and 12 h after the hurricane stage a circulation center could not be found at 850 hPa by aircraft reconnaissance. At hurricane strength the vortex contained classic structure seen in intensifying hurricanes, with the exception of 7°–12°C dewpoint depressions in the lower troposphere upshear of the center. These extended from the 100-km radius to immediately adjacent to the eyewall, where equivalent potential temperature gradients reached 6 K km−1. The dry air was not present prior to intensification, suggesting that it was associated with vertical shear–induced subsidence upshear of the developing storm. It is argued that weakening of the vortex was driven by cooling associated with the mixing of dry air into the core, and subsequent evaporation and cold downdrafts. Evidence suggests that this mixing might have been enhanced by eyewall instabilities after the period of rapid deepening. The existence of a fragile, small, but genuinely hurricane-strength vortex at the surface for 6 h presents difficult problems for forecasters. Such a “temporary hurricane” in strongly sheared flow might require a different warning protocol than longer-lasting hurricane vortices in weaker shear.


2020 ◽  
Vol 29 (2) ◽  
pp. 196-211
Author(s):  
Osama Al-Taai ◽  
Zainab Abbood

The Convective Available Potential Energy (CAPE) represents the amount of energy for a sample of air. The sample departs vertically within the atmosphere and through these values the potential energy to predict the extreme weather conditions such as storms, hurricanes, lightning and thunder. Data are taken by CAPE, convective precipitation (Cp) and total precipitation (Tp) from satellites recorded by the European Centre for Medium-Range Weather Forecasts (ECMWF). The choice of 30 years (1989– –2018) over Iraq station between two latitudes (29.5°–37.22° N) and two longitudes (48.45°–38.45° E). Otherwise, we have studied total yearly mean of CAPE, Cp and Tp over Iraq, the total monthly mean of CAPE, Cp and Tp for the selected station, as well as the relationship between of CAPE, Cp and Tp for the selected station. The results showed that the highest total yearly mean of CAPE, Cp and Tp over Iraq was included northern stations and lowest was included central and southern stations. The highest total monthly mean of CAPE, Cp and Tp for Zakho station. The relationship between the CAPE and Cp is positive and the relationship between CAPE and Tp is positive too at five stations but Mosul station represents very high correlation while Zakho station represents the low correlation.


2006 ◽  
Vol 23 (11) ◽  
pp. 1506-1518 ◽  
Author(s):  
Gé Verver ◽  
Masatomo Fujiwara ◽  
Pier Dolmans ◽  
Cor Becker ◽  
Paul Fortuin ◽  
...  

Abstract In climate research there is a strong need for accurate observations of water vapor in the upper atmosphere. Radiosoundings provide relative humidity profiles but the accuracy of many routine instruments is notoriously inadequate in the cold upper troposphere. In this study results from a soundings program executed in Paramaribo, Suriname (5.8°N, 55.2°W), are presented. The aim of this program was to compare the performance of different humidity sensors in the upper troposphere in the Tropics and to test different bias corrections suggested in the literature. The payload of each sounding consisted of a chilled-mirror “Snow White” sensor from Meteolabor AG, which was used as a reference, and two additional sensors from Vaisala, that is, either the RS80A, the RS80H, or the RS90. In total 37 separate soundings were made. For the RS80A a clear, dry bias of between −4% and −8% RH is found in the lower troposphere compared to the Snow White observation, confirming the findings in previous studies. A mean dry bias was found in the upper troposphere, which could be effectively corrected. The RS80H sensor shows a significant wet bias of 2%–5% in RH in the middle and upper troposphere, which has not been reported before. Comparing observations with RS80H sensors of different ages gives no indication of sensor aging or sensor contamination. It is therefore concluded that the plastic cover introduced by Vaisala to avoid sensor contamination is effective. Finally, the RS90 sensor yields a small but significant wet bias of 2%–3% below 7-km altitude. The time-lag error correction from Miloshevich et al. was applied to the Vaisala data, which resulted in an increased variability in the relative humidity profile above 9- (RS80A), 8- (RS80H), and 11-km (RS90) altitude, respectively, which is in better agreement with the Snow White data. The averaged Snow White profile is compared with the average profiles of relative humidity from the European Centre for Medium-Range Weather Forecasts (ECMWF). No significant bias is found in either the analyses or the forecasts. The correlation coefficient for the Snow White and ECMWF data between 200 and 800 hPa was 0.66 for the 36-h forecast and 0.77 for the analysis.


2010 ◽  
Vol 67 (12) ◽  
pp. 4001-4016 ◽  
Author(s):  
Joseph Egger ◽  
Klaus-Peter Hoinka

Abstract Given the distribution of one atmospheric variable, that of nearly all others can be derived in balanced flow. In particular, potential vorticity inversion (PVI) selects potential vorticity (PV) to derive pressure, winds, and potential temperature θ. Potential temperature inversion (PTI) starts from available θ fields to derive pressure, winds, and PV. While PVI has been applied extensively, PTI has hardly been used as a research tool although the related technical steps are well known and simpler than those needed in PVI. Two idealized examples of PTI and PVI are compared. The 40-yr European Centre for Medium-Range Weather Forecasts (ECMWF) Re-Analysis (ERA-40) datasets are used to determine typical anomalies of PV and θ in the North Atlantic storm-track region. Statistical forms of PVI and PTI are applied to these anomalies. The inversions are equivalent but the results of PTI are generally easier to understand than those of PVI. The issues of attribution and piecewise inversion are discussed.


2016 ◽  
Author(s):  
Karl Bumke ◽  
Gert König-Langlo ◽  
Julian Kinzel ◽  
Marc Schröder

Abstract. The satellite derived HOAPS (Hamburg Ocean Atmosphere Parameters and Fluxes from Satellite data) and ECMWF (European Centre for Medium-Range Weather Forecasts) ERA-Interim reanalysis data sets have been validated against in-situ precipitation measurements from ship rain gauges and optical disdrometers over the open-ocean by applying a statistical analysis for binary forecasts. For this purpose collocated pairs of data were merged within a certain temporal and spatial threshold into single events, according to the satellites' overpass, the observation and the forecast times. HOAPS detects the frequency of precipitation well, while ERA-Interim strongly overestimates it, especially in the tropics and subtropics. Although precipitation rates are difficult to compare because along-track point measurements are collocated with areal estimates and the numbers of available data are limited, we find that HOAPS underestimates precipitation rates, while ERA-Interim's Atlantic-wide average precipitation rate is close to measurements. However, regionally averaged over latitudinal belts, there are deviations between the observed mean precipitation rates and ERA-Interim. The most obvious ERA-Interim feature is an overestimation of precipitation in the area of the intertropical convergence zone and the southern sub-tropics over the Atlantic Ocean. For a limited number of snow measurements by optical disdrometers it can be concluded that both HOAPS and ERA-Interim are suitable to detect the occurrence of solid precipitation.


Sign in / Sign up

Export Citation Format

Share Document