Implementation of new high-rise building staircase pressure differential system improvements

Author(s):  
Dorota Brzezinska ◽  
Marcin Fryda

The following technical note demonstrates full-scale staircase test results of the pressure differential system improvement method described by Fryda et al. in 2021. It is a continuation of experimental research on the impact of the escape route’s leakages on the pressure differential systems for staircases. Based on the lab experiments, it has been found that an additional throttle of the leak implemented in the pressure differential system improves its effectiveness and allows it to be more precisely adjusted to the required overpressure. The results presented in this article have confirmed this hypothesis and provided the opportunity to apply for new patent solutions of a special throttle of the leak control and pressure regulating system. The proposed new leakage-based improvements could increase the efficiency of existing systems based on proportional-integral-derivative controller and could also be installed in new buildings.

2020 ◽  
Vol 42 (1) ◽  
pp. 112-124
Author(s):  
Marcin Fryda ◽  
Dorota Brzezińska ◽  
Marek Dziubiński

The task of fire pressure differential systems in a building is to prevent smoke from entering protected spaces such as stairwells and areas that should remain smoke-free in the event of fire. The required overpressure must consider leakage within the protected space. This article presents the results of testing to determine the impact of leakage of the protected space on the conditions for maintaining overpressure. The research was conducted in accordance with draft standard N161-prEN12101-6. The pressure distribution as a function of time was obtained for stairwells with different levels of leakage, using a constant flow aeration fan as well as systems with a variable airflow. Practical application: Designers of differential pressure smoke control systems are required to calculate aeration fan airflow volume. The leakage level of protected spaces should be taken into consideration given that European Standard EN12101-6 suggests that gap areas should be minimal. Consequently, modern building design and construction requires estimation of the leakage area in such protected spaces. The objective is to improve safety of buildings and reduce the system reaction time during a fire.


Author(s):  
Larisa Dmitrievna Popovich ◽  
Svetlana Valentinovna Svetlichnaya ◽  
Aleksandr Alekseevich Moiseev

Diabetes – a disease in which the effect of the treatment substantially depends on the patient. Known a study showed that the use of glucometers with the technology of three-color display of test results facilitates self-monitoring of blood sugar and leads to a decrease in glycated hemoglobin (HbAlc). Purpose of the study: to modeling the impact of using of a glucometer with a color-coded display on the clinical outcomes of diabetes mellitus and calculating, the potential economic benefits of reducing the hospitalization rate of patients with diabetes. Material and methods. Based on data from two studies (O. Schnell et al. and M. Baxter et al.) simulation of the reduction in the number of complications with the use of a glucometer with a color indication. In a study by O. Schnell et al. a decrease of HbA1c by 0.69 percent is shown when using the considered type of glucometers, which was the basis of the model. Results. In the model, the use of a glucometer with a color-coded display for type 1 diabetes led to a decrease in the total number of complications by 9.2 thousand over 5 years per a cohort of 40 thousand patients with different initial levels of HbA1c. In a cohort of 40 thousand patients with type 2 diabetes, the simulated number of prevented complications was 1.7 thousand over 5 years. When extrapolating these data to all patients with diabetes included in the federal register of diabetes mellitus (FRD), the number of prevented complications was 55.4 thousand cases for type 1 diabetes and 67.1 thousand cases for type 2 diabetes. The possible economic effect from the use of the device by all patients with a diagnosis of diabetes, which are included in the FRD, estimated at 1.5 billion rubles for a cohort of patients with type 1 diabetes and 5.3 billion rubles for patients with type 2 diabetes. Conclusion. Improving the effectiveness of self-monitoring, which is the result of the use of glucometers with color indicators, can potentially significantly reduce the incidence of complications in diabetes and thereby provide significant economic benefits to society.


2019 ◽  
Vol 43 (3) ◽  
pp. 229-249 ◽  
Author(s):  
Shahrzad Soudian ◽  
Umberto Berardi

This article investigates the possibility to enhance the use of latent heat thermal energy storage (LHTES) as an energy retrofit measure by night ventilation strategies. For this scope, phase change materials (PCMs) are integrated into wall and ceiling surfaces of high-rise residential buildings with highly glazed facades that experience high indoor diurnal temperatures. In particular, this article investigates the effect of night ventilation on the performance of the PCMs, namely, the daily discharge of the thermal energy stored by PCMs. Following previous experimental tests that have shown the efficacy of LHTES in temperate climates, a system comprising two PCM layers with melting temperatures selected for a year-around LHTES was considered. To quantify the effectiveness of different night ventilation strategies to enhance the potential of this composite PCM system, simulations in EnergyPlusTM were performed. The ventilation flow rate, set point temperature, and operation period were the main tested parameters. The performance of the PCMs in relation to the variables was evaluated based on indoor operative temperature and cooling energy use variations in Toronto and New York in the summer. The solidification of the PCMs was analyzed based on the amount of night ventilation needed in each climate condition. The results quantify the positive impact of combining PCMs with night ventilation on cooling energy reductions and operative temperature regulation of the following days. In particular, the results indicate higher benefits obtainable with PCMs coupled with night ventilation in the context of Toronto, since this city experiences higher daily temperature fluctuations. The impact of night ventilation design variables on the solidification rate of the PCMs varied based on each parameter leading to different compromises based on the PCM and climate characteristics.


2021 ◽  
pp. 135481662110224
Author(s):  
Liang-Ju Wang ◽  
Ming-Hsiang Chen ◽  
Zhandong Yang ◽  
Ching-Hui (Joan) Su

This study proposes and tests two hypotheses concerning the effects of hotel industry operations on air quality based on data of 26 major tourist cities in China from 2002 to 2017. The empirical analyses take two steps. In the first step, panel regression test results reveal that hotel industry operations (measured by hotel sales revenue) significantly raise the value of particulate matter (PM)2.5 (the key indicator of air quality), supporting the first hypothesis that hotel industry operations deteriorate air quality and providing empirical evidence of the adverse impact of the hotel industry on air quality. In the second step, subsample analyses support the second hypothesis that the impact of hotel sales revenue on air quality diminishes over time. The results from the rolling regression tests validate the existence of a diminishing effect of hotel industry operations on air quality.


2021 ◽  
Vol 11 (14) ◽  
pp. 6537
Author(s):  
Marian Łupieżowiec

The article presents the concept of monitoring buildings and infrastructure elements located near large construction investments (the construction of high-rise buildings of the Oak Terraces housing estate in Katowice and the construction of a tunnel under the roundabout in Katowice along the intercity express road DTŚ). The impacts include deep excavation, lowering of the groundwater level over a large area, and dynamic influences related to the use of impact methods of soil improvement. The presented monitoring includes observation of the groundwater level with the use of piezometers, geodetic measurements of settlement and inclinations, as well as the measurement of vibration amplitudes generated during the works involving shocks and vibrations. It was also important to observe the development of cracks on the basis of a previously made inventory of damage. The results of the monitoring allow corrections to be made in the technology of works (e.g., reduction of vibration amplitudes, application of additional protections at excavations, etc.) or the use additional safety measures. Currently, there are also monitoring systems used during the operation of completed facilities.


Polymers ◽  
2021 ◽  
Vol 13 (11) ◽  
pp. 1895
Author(s):  
Tomasz Kozior ◽  
Czesław Kundera

This research paper reviews the test results involving viscoelastic properties of cellular structure models made with the PolyJet Matrix—PJM additive technology. The designed test specimens were of complex cellular structure and made of three various photo-curable polymer resin types. Materials were selected taking into account the so-called “soft” and “tough” material groups. Compressive stress relaxation tests were conducted in accordance with the recommendations of standard ISO 3384, and the impact of the geometric structure shape and material selection on viscoelastic properties, as well as the most favorable geometric variants of the tested cellular structure models were determined. Mathematica and Origin software was used to conduct a statistical analysis of the test results and determine five-parameter functions approximating relaxation curves. The most favorable rheological was adopted and its mean parameters determined, which enables to match both printed model materials and their geometry in the future, to make a component with a specific rheological response. Furthermore, the test results indicated that there was a possibility of modelling cellular structures within the PJM technology, using support material as well.


2021 ◽  
Vol 11 (8) ◽  
pp. 3315
Author(s):  
Fabio Rizzo

Experimental wind tunnel test results are affected by acquisition times because extreme pressure peak statistics depend on the length of acquisition records. This is also true for dynamic tests on aeroelastic models where the structural response of the scale model is affected by aerodynamic damping and by random vortex shedding. This paper investigates the acquisition time dependence of linear transformation through singular value decomposition (SVD) and its correlation with floor accelerometric signals acquired during wind tunnel aeroelastic testing of a scale model high-rise building. Particular attention was given to the variability of eigenvectors, singular values and the correlation coefficient for two wind angles and thirteen different wind velocities. The cumulative distribution function of empirical magnitudes was fitted with numerical cumulative density function (CDF). Kolmogorov–Smirnov test results are also discussed.


2017 ◽  
Author(s):  
Ting Yang ◽  
Zifa Wang ◽  
Wei Zhang ◽  
Alex Gbaguidi ◽  
Nubuo Sugimoto ◽  
...  

Abstract. Predicting air pollution events in low atmosphere over megacities requires thorough understanding of the tropospheric dynamic and chemical processes, involving notably, continuous and accurate determination of the boundary layer height (BLH). Through intensive observations experimented over Beijing (China), and an exhaustive evaluation existing algorithms applied to the BLH determination, persistent critical limitations are noticed, in particular over polluted episodes. Basically, under weak thermal convection with high aerosol loading, none of the retrieval algorithms is able to fully capture the diurnal cycle of the BLH due to pollutant insufficient vertical mixing in the boundary layer associated with the impact of gravity waves on the tropospheric structure. Subsequently, a new approach based on gravity wave theory (the cubic root gradient method: CRGM), is developed to overcome such weakness and accurately reproduce the fluctuations of the BLH under various atmospheric pollution conditions. Comprehensive evaluation of CRGM highlights its high performance in determining BLH from Lidar. In comparison with the existing retrieval algorithms, the CRGM potentially reduces related computational uncertainties and errors from BLH determination (strong increase of correlation coefficient from 0.44 to 0.91 and significant decrease of the root mean square error from 643 m to 142 m). Such newly developed technique is undoubtedly expected to contribute to improve the accuracy of air quality modelling and forecasting systems.


Sign in / Sign up

Export Citation Format

Share Document