scholarly journals Design and Performance of an Experimental Cooled Perch System for Heat Stress Relief of Laying Hens

2020 ◽  
Vol 63 (4) ◽  
pp. 1109-1121
Author(s):  
Yijie Xiong ◽  
Richard S. Gates ◽  
Jiaying Hu ◽  
Patricia Y. Hester ◽  
Heng-wei Cheng

This article summarizes the design and performance of a cooled perch system for laying hens during heat stress.Water flow rates, perch loop water temperatures, and system net heat gain are provided.The average daily net heat absorption data, useful for sizing thermal water storage and chiller capacity in future applications, is 256 W m-1 perch length, or 43.2 W per hen housed.This analysis provides a baseline for future cooled perch system design in other application settings.Abstract. This article summarizes the engineering design and performance of a cooled perch system used in a multi-year collaborative study to evaluate cooled perch effects on hen production, health, and welfare during heat stress. The cooled perch system consisted of two replicates (CP-1 and CP-2) of three-tier cage units with galvanized perch pipes forming a complete loop in each tier (top, middle, bottom) in which chilled water circulated. A total of 324 White Leghorns at 17 weeks of age were randomly assigned to 36 cages (76 cm × 52 cm × 48 cm) in six banks placed in the same room. Flow for each loop was provided by loop pumps that drew chilled water from an open thermal storage manifold and returned it to the same manifold. Each thermal storage was cooled by continuously circulating water through a water chiller. Each loop pump was thermostatically controlled based on the cage air temperature. The water inlet and outlet temperatures, cage air temperatures, and loop water flow rates during stable system operation were measured for performance evaluation. Mean water flow rates in 2015 were 5.19 and 5.45 kg min-1 for CP-1 and CP-2, respectively, but significantly declined to 3.91 and 4.03 kg min-1 in 2016. The mean loop water temperature rise was about 2°C for both replicates. The mean loop net heat gain of CP-1 and CP-2 ranged from 690 to 850 W and from 551 to 1,298 W, respectively, with a significant difference between CP-2 loops (p < 0.0001), indicating a discrepancy between the manufacturer’s pump curve and field performance. There was a correlation between room air temperature and net heat gain for all loops of CP-1 and the top loop of CP-2 (p < 0.0001), suggesting that natural convection and radiation from the room to the pipe were the major contributors to loop heat gain. The average daily net heat gain was approximately 2,334 W per replicate, 256 W m-1 perch length, or 43.2 W per hen housed. This analysis provides a baseline for future cooled perch system design in other application settings. An example is provided for sizing the thermal water storage and chiller capacity. In addition, a closed water system with a properly sized expansion tank is recommended for future energy-efficient cooled perch applications. Keywords: Alternative cooling, Heat stress, Heat transfer, Poultry.

2020 ◽  
Vol 51 (4) ◽  
pp. 209-219
Author(s):  
Mohamed Saied Ghoname

An experiment was conducted in three commercial laying hen houses with 32-week-old hens in the summer of 2017 in a commercial farm in Gharbia Province, Egypt (31.06ºN, 31.16ºE) using an evaporative pad cooling system to determine the most suitable water flow rate for maintaining indoor air temperature within the thermal comfort zone. The experiment was conducted using three different water flow rates, i.e. 4.76, 5.65, and 6.35 L min–1.m–2, to assess the effect of different water flow rates on evaporative pad cooling system performance and determine the most suitable water flow rate for maintaining the thermal comfort zone of laying hens. The evaporative pad cooling system maintained the mean indoor air temperature below 28°C. The mean indoor air relative humidity during the experimental period ranged from 72.6 to 73.8%. The 4.76 L min–1.m–2 water flow rate resulted in the highest saturation efficiency (ca. 73.75%). In contrast, the 6.35 L min–1 m–2 water flow rate resulted in the lowest saturation efficiency (70.63%). The mean cooling energy values were 69.11, 66.0, and 66.65 kwh for water flow rates of 4.76, 5.56, and 6.35 Lmin–1m–2, respectively. The highest temperature-humidity index was 27.78°C, which indicated that birds were not stressed in all treatments.


2011 ◽  
Vol 105-107 ◽  
pp. 922-925 ◽  
Author(s):  
Chao He ◽  
Wei Lin Guo ◽  
Yi Yun Huang

To discuss the effect of energy saving of heat-reflective insulation coating on exterior walls of building, the wall temperature change of two test rooms with heat insulation or not in Hangzhou has been monitored in summer, and the heat flux data of east, south and west walls were analyzed. The results indicate that the temperature of outside wall surface with the heat reflective insulation coating is reduced effectively, and the maximum temperature change was about 9, 10°C. There is a positive proportional between the mean daily air temperature and heat gain that the heat gain increases with the mean daily air temperature. By calculating, the higher the air temperature, the more the cooling effect of coating in summer. But the higher the mean daily temperature do not mean that the more heat gain in summer. The result shows the energy saving effect of the heat insulation coating on building wall was very obvious in summer in Hangzhou.


1980 ◽  
Author(s):  
R. D. Ingebo

Cold flow atomization tests of several different designs of swirl can combustor modules were conducted in a 7.6 cm diameter duct at airflow rates (per unit area) of 7.3 to 25.7 g/cm2 sec and water flow rates of 6.3 to 18.9 g/sec. The effect of air and water flow rates on the mean drop size of water sprays produced with the swirl blast fuel injectors were determined. Also, from these data it was possible to determine the effect of design modifications on the atomizing performance of various fuel injector and air swirler configurations. The trend in atomizing performance, as based on the mean drop size, was then compared with the trends in the production of nitrogen oxides obtained in combustion studies with the same swirl can combustors.


Author(s):  
Kaminat Muradovna Agakhanova

Heat stress is one of the main factors affecting the well-being and performance of cows during the warm season. The article presents the results of calculating the daily change in the ventilation air consumption during the cowshed aeration. The influence of changes in the outside air temperature on the amount of air exchange was revealed.


2000 ◽  
Vol 16 (2) ◽  
pp. 107-114 ◽  
Author(s):  
Louis M. Hsu ◽  
Judy Hayman ◽  
Judith Koch ◽  
Debbie Mandell

Summary: In the United States' normative population for the WAIS-R, differences (Ds) between persons' verbal and performance IQs (VIQs and PIQs) tend to increase with an increase in full scale IQs (FSIQs). This suggests that norm-referenced interpretations of Ds should take FSIQs into account. Two new graphs are presented to facilitate this type of interpretation. One of these graphs estimates the mean of absolute values of D (called typical D) at each FSIQ level of the US normative population. The other graph estimates the absolute value of D that is exceeded only 5% of the time (called abnormal D) at each FSIQ level of this population. A graph for the identification of conventional “statistically significant Ds” (also called “reliable Ds”) is also presented. A reliable D is defined in the context of classical true score theory as an absolute D that is unlikely (p < .05) to be exceeded by a person whose true VIQ and PIQ are equal. As conventionally defined reliable Ds do not depend on the FSIQ. The graphs of typical and abnormal Ds are based on quadratic models of the relation of sizes of Ds to FSIQs. These models are generalizations of models described in Hsu (1996) . The new graphical method of identifying Abnormal Ds is compared to the conventional Payne-Jones method of identifying these Ds. Implications of the three juxtaposed graphs for the interpretation of VIQ-PIQ differences are discussed.


2004 ◽  
Vol 79 (3) ◽  
pp. 545-570 ◽  
Author(s):  
Margaret A. Abernethy ◽  
Jan Bouwens ◽  
Laurence van Lent

We investigate two determinants of two choices in the control system of divisionalized firms, namely decentralization and use of performance measures. The two determinants are those identified in the literature as important to control system design: (1) information asymmetries between corporate and divisional managers and (2) division interdependencies. We treat decentralization and performance measurement choices as endogenous variables and examine the interrelation among these choices using a simultaneous equation model. Using data from 78 divisions, our results indicate that decentralization is positively related to the level of information asymmetries and negatively to intrafirm interdependencies, while the use of performance measures is affected by the level of interdependencies among divisions within the firm, but not by information asymmetries. We find some evidence that decentralization choice and use of performance measures are complementary.


Author(s):  
Ewa A. Burian ◽  
Lubna Sabah ◽  
Klaus Kirketerp-Møller ◽  
Elin Ibstedt ◽  
Magnus M. Fazli ◽  
...  

Acute wounds may require cleansing to reduce the risk of infection. Stabilized hypochlorous acid in acetic buffer (HOCl + buffer) is a novel wound irrigation solution with antimicrobial properties. We performed a first-in-man, prospective, open-label pilot study to document preliminary safety and performance in the treatment of acute wounds. The study enrolled 12 subjects scheduled for a split-skin graft transplantation, where the donor site was used as a model of an acute wound. The treatment time was 75 s, given on 6 occasions. A total of 7 adverse events were regarded as related to the treatment; all registered as pain during the procedure for 2 subjects. One subject had a wound infection at the donor site. The mean colony-forming unit (CFU) decreased by 41% after the treatment, and the mean epithelialization was 96% on both days 14 (standard deviation [SD] 8%) and 21 (SD 10%). The study provides preliminary support for the safety, well-tolerance, and efficacy of HOCl + buffer for acute wounds. The pain was frequent although resolved quickly. Excellent wound healing and satisfying antimicrobial properties were observed. A subsequent in vitro biofilm study also indicated good antimicrobial activity against Pseudomonas aeruginosa with a 96% mean reduction of CFU, when used for a treatment duration of 15 min ( P < .0001), and a 50% decrease for Staphylococcus aureus ( P = .1010). Future larger studies are needed to evaluate the safety and performance of HOCl + buffer in acute wounds, including the promising antimicrobial effect by prolonged treatment on bacterial biofilms.


2021 ◽  
Vol 99 (3) ◽  
Author(s):  
Y Zhu ◽  
L J Johnston ◽  
M H Reese ◽  
E S Buchanan ◽  
J E Tallaksen ◽  
...  

Abstract This study was conducted to evaluate whether cooled floor pads combined with chilled drinking water could alleviate negative impacts of heat stress on lactating sows. Thirty sows (Landrace × Yorkshire, Parity = 1 to 6) were housed in individual farrowing stalls in two rooms with temperatures being controlled at 29.4°C (0700–1900 hours) and 23.9°C (1900–0700 hours). Sows in one room (Cool), but not in the other room (Control) were provided cooled floor pads (21–22°C) and chilled drinking water (13–15°C). Behavior of sows (15 sows/treatment) was video recorded during farrowing, and days 1, 3, 7, 14, and 21 after farrowing. Videos were viewed continuously to register the birth time of each piglet, from which total farrowing duration and birth intervals were calculated. The number of drinking bouts and the duration of each drinking bout were registered for each sow through viewing videos continuously for 2 h (1530–1730 hours) each video-recording day. Postures (lying laterally, lying ventrally, sitting, and standing) were recorded by scanning video recordings at 5-min intervals for 24 h each video-recording day, and time budget for each posture was calculated. Rectal temperature and respiration rate were measured for all sows the day before and after farrowing, and then once weekly. Sow and litter performance was recorded. Data were analyzed using the Glimmix procedure of SAS. The cooling treatment did not affect sow behavior or litter performance. Sows in the Cool room had lower rectal temperature (P = 0.03) and lower respiration rate (P &lt; 0.001), consumed more feed (P = 0.03), tended to have reduced weight loss (P = 0.07), and backfat loss (P = 0.07) during lactation than sows in the Control room. As lactation progressed, sows increased drinking frequency (P &lt; 0.001) and time spent lying ventrally (P &lt; 0.0001), standing (P &lt; 0.001), and sitting (P &lt; 0.0001), and decreased time spent lying laterally (P &lt; 0.0001) in both Cool and Control rooms. While cooled floor pads combined with chilled drinking water did not affect sow behavior, they did alleviate heat stress partially, as indicated by decreased rectal temperature, respiration rate, weight, and backfat loss, and increased feed intake in lactating sows.


2021 ◽  
Vol 13 (4) ◽  
pp. 640
Author(s):  
Sadroddin Alavipanah ◽  
Dagmar Haase ◽  
Mohsen Makki ◽  
Mir Muhammad Nizamani ◽  
Salman Qureshi

The changing climate has introduced new and unique challenges and threats to humans and their environment. Urban dwellers in particular have suffered from increased levels of heat stress, and the situation is predicted to continue to worsen in the future. Attention toward urban climate change adaptation has increased more than ever before, but previous studies have focused on indoor and outdoor temperature patterns separately. The objective of this research is to assess the indoor and outdoor temperature patterns of different urban settlements. Remote sensing data, together with air temperature data collected with temperature data loggers, were used to analyze land surface temperature (outdoor temperature) and air temperature (indoor temperature). A hot and cold spot analysis was performed to identify the statistically significant clusters of high and low temperature data. The results showed a distinct temperature pattern across different residential units. Districts with dense urban settlements show a warmer outdoor temperature than do more sparsely developed districts. Dense urban settlements show cooler indoor temperatures during the day and night, while newly built districts show cooler outdoor temperatures during the warm season. Understanding indoor and outdoor temperature patterns simultaneously could help to better identify districts that are vulnerable to heat stress in each city. Recognizing vulnerable districts could minimize the impact of heat stress on inhabitants.


Designs ◽  
2021 ◽  
Vol 5 (1) ◽  
pp. 4
Author(s):  
Dillon Alexander Wilson ◽  
Kul Pun ◽  
Poo Balan Ganesan ◽  
Faik Hamad

Microbubble generators are of considerable importance to a range of scientific fields from use in aquaculture and engineering to medical applications. This is due to the fact the amount of sea life in the water is proportional to the amount of oxygen in it. In this paper, experimental measurements and computational Fluid Dynamics (CFD) simulation are performed for three water flow rates and three with three different air flow rates. The experimental data presented in the paper are used to validate the CFD model. Then, the CFD model is used to study the effect of diverging angle and throat length/throat diameter ratio on the size of the microbubble produced by the Venturi-type microbubble generator. The experimental results showed that increasing water flow rate and reducing the air flow rate produces smaller microbubbles. The prediction from the CFD results indicated that throat length/throat diameter ratio and diffuser divergent angle have a small effect on bubble diameter distribution and average bubble diameter for the range of the throat water velocities used in this study.


Sign in / Sign up

Export Citation Format

Share Document