Combined shear and compression analysis using a modified Iosipescu shear test device. Experimental studies on dry wood

Holzforschung ◽  
2005 ◽  
Vol 59 (5) ◽  
pp. 539-545 ◽  
Author(s):  
Federica De Magistris ◽  
Lennart Salmén

Abstract The mechanical treatment of wood in a refiner involves a complex combination of shear and compression forces. To obtain more knowledge on this process, the possibility of using an apparatus based on the Iosipescu shear test device to measure the behaviour of wood under a combined shear and compression load was tested. In this new apparatus, different combinations of shear and compression load were achieved by different rotations of the shear test device itself. Numerical simulations of the combined shear and compression test were carried out and compared with experimental data to verify the reliability of the modified device as applied to wood. It was concluded that the new apparatus is suitable for applying different combinations of shear and compression load in testing wood samples. However, finite element analysis showed that with the use of homogeneous material in the model, the level of strain reached would be 10-fold smaller. This fact is probably due to the honeycomb structure of the wood cells, which allows for different local deformation that could not be represented by the continuous material used in the model.

1996 ◽  
Vol 118 (2) ◽  
pp. 240-246 ◽  
Author(s):  
P. J. Prendergast ◽  
R. Huiskes

Damage accumulation in living tissues occurs when the rate of damage formation is greater than the rate of damage repair. For very large increases in the loading rate of bones, this can result in “stress fractures” due to the growth and coalescence of fatigue related microdamage. At lower increases of loading rates, the damage accumulation process is halted because there is time for adaptive bone-remodeling to occur in response to the new load. However, it is not known if there is a relationship between microdamage and bone remodeling per se. One hypothesis for the control of bone remodeling is that osteocytes sense strains and mediate osteoblastic and osteoclastic activity. The purpose of this study was to investigate whether damage generates strains which may trigger bone remodeling. If this were true, then accumulative damage would cause adaptive bone remodeling. This study applies the methods of finite element analysis to determine the effect of observed damage mechanisms on the proposed sensors of remodeling in Haversian bone. Individual lamellae are modeled and osteocyte-lacunae are included in a generalized plane strain geometric representation. It is predicted that microdamage alters the local deformation behavior around lacunae, and that the changes increase as microdamage accumulates. Hence, if damage accumulates in a bone, it could be sensed as a change in strain at a microstructural level. The results give theoretical support to the experimental studies that have shown a correlation between microdamage and the initiation of resorption as a first step in bone remodeling.


Polymers ◽  
2021 ◽  
Vol 13 (12) ◽  
pp. 1983
Author(s):  
Olimpia Basurto-Vázquez ◽  
Elvia P. Sánchez-Rodríguez ◽  
Graham J. McShane ◽  
Dora I. Medina

Energy resulting from an impact is manifested through unwanted damage to objects or persons. New materials made of cellular structures have enhanced energy absorption (EA) capabilities. The hexagonal honeycomb is widely known for its space-filling capacity, structural stability, and high EA potential. Additive manufacturing (AM) technologies have been effectively useful in a vast range of applications. The evolution of these technologies has been studied continuously, with a focus on improving the mechanical and structural characteristics of three-dimensional (3D)-printed models to create complex quality parts that satisfy design and mechanical requirements. In this study, 3D honeycomb structures of novel material polyethylene terephthalate glycol (PET-G) were fabricated by the fused deposition modeling (FDM) method with different infill density values (30%, 70%, and 100%) and printing orientations (edge, flat, and upright). The effectiveness for EA of the design and the effect of the process parameters of infill density and layer printing orientation were investigated by performing in-plane compression tests, and the set of parameters that produced superior results for better EA was determined by analyzing the area under the curve and the welding between the filament layers in the printed object via FDM. The results showed that the printing parameters implemented in this study considerably affected the mechanical properties of the 3D-printed PET-G honeycomb structure. The structure with the upright printing direction and 100% infill density exhibited an extension to delamination and fragmentation, thus, a desirable performance with a long plateau region in the load–displacement curve and major absorption of energy.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Saurabhi Samant ◽  
Wei Wu ◽  
Shijia Zhao ◽  
Behram Khan ◽  
Mohammadali Sharzehee ◽  
...  

AbstractLeft main (LM) coronary artery bifurcation stenting is a challenging topic due to the distinct anatomy and wall structure of LM. In this work, we investigated computationally and experimentally the mechanical performance of a novel everolimus-eluting stent (SYNERGY MEGATRON) purpose-built for interventions to large proximal coronary segments, including LM. MEGATRON stent has been purposefully designed to sustain its structural integrity at higher expansion diameters and to provide optimal lumen coverage. Four patient-specific LM geometries were 3D reconstructed and stented computationally with finite element analysis in a well-validated computational stent simulation platform under different homogeneous and heterogeneous plaque conditions. Four different everolimus-eluting stent designs (9-peak prototype MEGATRON, 10-peak prototype MEGATRON, 12-peak MEGATRON, and SYNERGY) were deployed computationally in all bifurcation geometries at three different diameters (i.e., 3.5, 4.5, and 5.0 mm). The stent designs were also expanded experimentally from 3.5 to 5.0 mm (blind analysis). Stent morphometric and biomechanical indices were calculated in the computational and experimental studies. In the computational studies the 12-peak MEGATRON exhibited significantly greater expansion, better scaffolding, smaller vessel prolapse, and greater radial strength (expressed as normalized hoop force) than the 9-peak MEGATRON, 10-peak MEGATRON, or SYNERGY (p < 0.05). Larger stent expansion diameters had significantly better radial strength and worse scaffolding than smaller stent diameters (p < 0.001). Computational stenting showed comparable scaffolding and radial strength with experimental stenting. 12-peak MEGATRON exhibited better mechanical performance than the 9-peak MEGATRON, 10-peak MEGATRON, or SYNERGY. Patient-specific computational LM stenting simulations can accurately reproduce experimental stent testing, providing an attractive framework for cost- and time-effective stent research and development.


2013 ◽  
Vol 423-426 ◽  
pp. 2035-2039
Author(s):  
Long Cang Huang ◽  
Yin Ping Cao ◽  
Yang Yu ◽  
Yi Hua Dou

In the process of oil and gas well production, tubing connection stand the axial alternating load during open well, shut well and fluid flow. In order to know premium connection seal ability under the loading, two types of P110 88.9mmx6.45mm premium tubing connections which called A connection and B connection are performed with finite element analysis, in which contact pressures and their the regularities distribution on sealing surface are analyzed. The results show that with the increasing of cycle number, the maximum contact pressures on sealing surface of both A connection and B connection are decreased. The decreasing of the maximum contact pressures on B connection is greater than those on A connection. With the increasing of cycle number of axial alternating compression load, the maximum contact pressure on sealing surface of A connection is decreased, and the maximum contact pressure on sealing surface of B connection remains constant. Compared the result, it shows that the seal ability of A connection is better than B connection under axial alternating tension load, while the seal ability of B connection is better than type A connection under axial alternating compression load.


2005 ◽  
Vol 58 (1) ◽  
pp. 37-48 ◽  
Author(s):  
Alan T. Zehnder ◽  
Mark J. Viz

The fracture mechanics of plates and shells under membrane, bending, twisting, and shearing loads are reviewed, starting with the crack tip fields for plane stress, Kirchhoff, and Reissner theories. The energy release rate for each of these theories is calculated and is used to determine the relation between the Kirchhoff and Reissner theories for thin plates. For thicker plates, this relationship is explored using three-dimensional finite element analysis. The validity of the application of two-dimensional (plate theory) solutions to actual three-dimensional objects is analyzed and discussed. Crack tip fields in plates undergoing large deflection are analyzed using von Ka´rma´n theory. Solutions for cracked shells are discussed as well. A number of computational methods for determining stress intensity factors in plates and shells are discussed. Applications of these computational approaches to aircraft structures are examined. The relatively few experimental studies of fracture in plates under bending and twisting loads are also reviewed. There are 101 references cited in this article.


2021 ◽  
Vol 7 (2) ◽  
pp. 58
Author(s):  
Celal Çakıroğlu ◽  
Gebrail Bekdaş

In the recent years natural fiber reinforced composites are increasingly receiving attention from the researchers and engineers due to their mechanical properties comparable to the conventional synthetic fibers and due to their ease of preparation, low cost and density, eco-friendliness and bio-degradability. Natural fibers such as kenaf or flux are being considered as a viable replacement for glass, aramid or carbon. Extensive experimental studies have been carried out to determine the mechanical behavior of different natural fiber types such as the elastic modulus, tensile strength, flexural strength and the Poisson’s ratio. This paper presents a review of the various experimental studies in the field of fiber reinforced composites while summarizing the research outcome about the elastic properties of the major types of natural fiber reinforced composites. Furthermore, the performance of a kenaf reinforced composite plate is demonstrated using finite element analysis and results are compared to a glass fiber reinforced laminated composite plate.


Author(s):  
Gürkan İrsel

In this study, the total algorithm of the strength-based design of the system for mass production has been developed. The proposed algorithm, which includes numerical, analytical, and experimental studies, was implemented through a case study on the strength-based structural design and fatigue analysis of a tractor-mounted sunflower stalk cutting machine (SSCM). The proposed algorithm consists of a systematic engineering approach, material selection and testing, design of the mass criteria suitability, structural stress analysis, computer-aided engineering (CAE), prototype production, experimental validation studies, fatigue calculation based on an FE model and experimental studies (CAE-based fatigue analysis), and an optimization process aimed at minimum weight. Approximately 85% of the system was designed using standard commercially available cross-section beams and elements using the proposed algorithm. The prototype was produced, and an HBM data acquisition system was used to collect the strain gage output. The prototype produced was successful in terms of functionality. Two- and three-dimensional mixed models were used in the structural analysis solution. The structural stress analysis and experimental results with a strain gage were 94.48% compatible in this study. It was determined using nCode DesignLife software that fatigue damage did not occur in the system using the finite element analysis (FEA) and experimental data. The SSCM design adopted a multi-objective genetic algorithm (MOGA) methodology for optimization with ANSYS. With the optimization solved from 422 iterations, a maximum stress value of 57.65 MPa was determined, and a 97.72 kg material was saved compared to the prototype. This study provides a useful methodology for experimental and advanced CAE techniques, especially for further study on complex stress, strain, and fatigue analysis of new systematic designs desired to have an optimum weight to strength ratio.


2018 ◽  
Vol 7 (2.21) ◽  
pp. 66 ◽  
Author(s):  
R Roopa ◽  
P Navin Karanth ◽  
S M. Kulkarni

This study reports the performance of piezo actuated compliant flexure diaphragm for micropump and MEMS application. To achieve the high performance of diaphragm at the low operating voltage compliant flexure diaphragm design is introduced. Very limited work has done on the diaphragms of micropump. Large numbers of mechanical micropumps have used plane diaphragms. The central deflection of diaphragm plays an important role in defining the micropump performance. The flow rate of mechanical type micropump strongly depends on the central deflection of diaphragm. In this paper compliant flexure diaphragms are designed for micropump to achieve higher deflection at lower operating voltage. Finite element analysis of compliant flexure diaphragm with single layer PVDF (Polyvinylidene fluoride) actuator is simulated in COMSOL. Compliant flexure diaphragms with a different number of flexures are analyzed. The central deflection of compliant flexure diaphragms is measured for driving voltages of 90V to 140V in 10 steps. The deflection of the compliant flexure diaphragm mainly depends on flexure width and length, the number of flexures in the diaphragm, PVDF thickness, diaphragm thickness and driving voltage. Use of compliant flexure diaphragm for micropump will reduce the mass and driving voltage of micropump. An attempt is made to compare the results of compliant flexure diaphragms with plane diaphragms. From the experimental results it is noticed that the compliant flexure diaphragm deflection is twice that of the plane diaphragm at same driving voltage. Deflection of three flexure and four flexure compliant diaphragms is 10.5µm and 11.5µm respectively at 140V.  


2017 ◽  
Vol 139 (5) ◽  
Author(s):  
Hiun Nagamori ◽  
Koji Takahashi

The stress states of elbow and tee pipes are complex and different from those of straight pipes. The low-cycle fatigue lives of elbows and tees cannot be predicted by Manson's universal slope method; however, a revised universal method proposed by Takahashi et al. was able to predict with high accuracy the low-cycle fatigue lives of elbows under combined cyclic bending and internal pressure. The objective of this study was to confirm the validity of the revised universal slope method for the prediction of low-cycle fatigue behaviors of elbows and tees of various shapes and dimensions under conditions of in-plane bending and internal pressure. Finite element analysis (FEA) was carried out to simulate the low-cycle fatigue behaviors observed in previous experimental studies of elbows and tees. The low-cycle fatigue behaviors, such as the area of crack initiation, the direction of crack growth, and the fatigue lives, obtained by the analysis were compared with previously obtained experimental data. Based on this comparison, the revised universal slope method was found to accurately predict the low-cycle fatigue behaviors of elbows and tees under internal pressure conditions regardless of differences in shape and dimensions.


Sign in / Sign up

Export Citation Format

Share Document