A High Resolution TEM Specimen Thinning System

1991 ◽  
Vol 254 ◽  
Author(s):  
R. Clampitt ◽  
G. G. Ross ◽  
M. Phelan ◽  
S. A. Davies

AbstractImprovements in specimen preparation for TEM analysis are being constantly sought, particularly in the study of microelectronics' materials and in failure analysis of devices. We describe here a compact commercial system capable of thinning (milling) selected regions of a specimen by means of a scanned focused ion beam of sub-micron spatial resolution.

1997 ◽  
Vol 3 (S2) ◽  
pp. 357-358
Author(s):  
C. Amy Hunt

The demand for TEM analysis in semiconductor failure analysis is rising sharply due to the shrinking size of devices. A well-prepared sample is a necessity for getting meaningful results. In the past decades, a significant amount of effort has been invested in improving sample preparation techniques for TEM specimens, especially precision cross-sectioning techniques. The most common methods of preparation are mechanical dimpling & ion milling, focused ion beam milling (FIBXTEM), and wedge mechanical polishing. Each precision XTEM technique has important advantages and limitations that must be considered for each sample.The concept for both dimpling & ion milling and wedge specimen preparation techniques is similar. Both techniques utilize mechanical polishing to remove the majority of the unwanted material, followed by ion milling to assist in final polishing or cleaning. Dimpling & ion milling produces the highest quality samples and is a relatively easy technique to master.


2018 ◽  
Author(s):  
C.S. Bonifacio ◽  
P. Nowakowski ◽  
M.J. Campin ◽  
M.L. Ray ◽  
P.E. Fischione

Abstract Transmission electron microscopy (TEM) specimens are typically prepared using the focused ion beam (FIB) due to its site specificity, and fast and accurate thinning capabilities. However, TEM and high-resolution TEM (HRTEM) analysis may be limited due to the resulting FIB-induced artifacts. This work identifies FIB artifacts and presents the use of argon ion milling for the removal of FIB-induced damage for reproducible TEM specimen preparation of current and future fin field effect transistor (FinFET) technologies. Subsequently, high-quality and electron-transparent TEM specimens of less than 20 nm are obtained.


Author(s):  
Max L. Lifson ◽  
Carla M. Chapman ◽  
D. Philip Pokrinchak ◽  
Phyllis J. Campbell ◽  
Greg S. Chrisman ◽  
...  

Abstract Plan view TEM imaging is a powerful technique for failure analysis and semiconductor process characterization. Sample preparation for near-surface defects requires additional care, as the surface of the sample needs to be protected to avoid unintentionally induced damage. This paper demonstrates a straightforward method to create plan view samples in a dual beam focused ion beam (FIB) for TEM studies of near-surface defects, such as misfit dislocations in heteroepitaxial growths. Results show that misfit dislocations are easily imaged in bright-field TEM and STEM for silicon-germanium epitaxial growth. Since FIB tools are ubiquitous in semiconductor failure analysis labs today, the plan view method presented provides a quick to implement, fast, consistent, and straightforward method of generating samples for TEM analysis. While this technique has been optimized for near-surface defects, it can be used with any application requiring plan view TEM analysis.


Author(s):  
Chin Kai Liu ◽  
Chi Jen. Chen ◽  
Jeh Yan.Chiou ◽  
David Su

Abstract Focused ion beam (FIB) has become a useful tool in the Integrated Circuit (IC) industry, It is playing an important role in Failure Analysis (FA), circuit repair and Transmission Electron Microscopy (TEM) specimen preparation. In particular, preparation of TEM samples using FIB has become popular within the last ten years [1]; the progress in this field is well documented. Given the usefulness of FIB, “Artifact” however is a very sensitive issue in TEM inspections. The ability to identify those artifacts in TEM analysis is an important as to understanding the significance of pictures In this paper, we will describe how to measure the damages introduced by FIB sample preparation and introduce a better way to prevent such kind of artifacts.


1999 ◽  
Vol 5 (S2) ◽  
pp. 914-915
Author(s):  
T. Kamino ◽  
T. Yaguchi ◽  
H. Matsumoto ◽  
H. Kobayashi ◽  
H. Koike

A method for site specific characterization of the materials using a dedicated focused ion beam(FIB) system and an analytical transmission electron microscope (TEM) was developed. Needless to say, in TEM specimen preparation using FIB system, stability of a specimen is quite important. The specimen stage employed in the developed FIB system is the one designed for high resolution TEM, and the specimen drift rate of the stage is less than lnm/min. In addition, FIB-TEM compatible specimen holder which allows milling of a specimen with the FIB system and observation of the specimen with the TEM without re-loading was developed. To obtain thin specimen from the area to be characterized correctly, confirmation of the area before final milling is needed. However, observation of cross sectional view in a FIB system is recommended because it causes damage by Ga ion irradiation. To solve this problem, we used a STEM unit as a viewer of FIB milled specimen.


2011 ◽  
Vol 17 (6) ◽  
pp. 889-895 ◽  
Author(s):  
Lynne M. Gignac ◽  
Surbhi Mittal ◽  
Sarunya Bangsaruntip ◽  
Guy M. Cohen ◽  
Jeffrey W. Sleight

AbstractThe ability to prepare multiple cross-section transmission electron microscope (XTEM) samples from one XTEM sample of specific sub-10 nm features was demonstrated. Sub-10 nm diameter Si nanowire (NW) devices were initially cross-sectioned using a dual-beam focused ion beam system in a direction running parallel to the device channel. From this XTEM sample, both low- and high-resolution transmission electron microscope (TEM) images were obtained from six separate, specific site Si NW devices. The XTEM sample was then re-sectioned in four separate locations in a direction perpendicular to the device channel: 90° from the original XTEM sample direction. Three of the four XTEM samples were successfully sectioned in the gate region of the device. From these three samples, low- and high-resolution TEM images of the Si NW were taken and measurements of the NW diameters were obtained. This technique demonstrated the ability to obtain high-resolution TEM images in directions 90° from one another of multiple, specific sub-10 nm features that were spaced 1.1 μm apart.


Author(s):  
Dietmar Vogel ◽  
Astrid Gollhardt ◽  
Bernd Michel

Three different methods of stress measurement with strong spatial resolution are presented. They base on stress relief techniques caused by focused ion beam milling, on altered electron backscattering by deformed lattices and on Stokes line shift measurements by Raman spectroscopy. The capability of these methods is demonstrated by their application to typical MEMS structures. A comparison between the methods is performed in order to outline potentials and limitations.


1997 ◽  
Vol 480 ◽  
Author(s):  
L. A. Giannuzzi ◽  
J. L. Drown ◽  
S. R. Brown ◽  
R. B. Irwin ◽  
F. A. Stevie

AbstractA site specific technique for cross-section transmission electron microscopy specimen preparation of difficult materials is presented. Focused ion beams are used to slice an electron transparent sliver of the specimen from a specific area of interest. Micromanipulation lift-out procedures are then used to transport the electron transparent specimen to a carbon coated copper grid for subsequent TEM analysis. The experimental procedures are described in detail and an example of the lift-out technique is presented.


1999 ◽  
Vol 5 (S2) ◽  
pp. 908-909
Author(s):  
J.L. Drown-MacDonald ◽  
B.I. Prenitzer ◽  
T.L. Shofner ◽  
L.A. Giannuzzi

Focused Ion Beam (FIB) specimen preparation for both scanning and transmission electron microscopy (SEM and TEM respectively) has seen an increase in usage over the past few years. The advantage to the FIB is that site specific cross sections (or plan view sections) may be fabricated quickly and reproducibly from numerous types of materials using a finely focused beam of Ga+ ions [1,2]. It was demonstrated by Prenitzer et al. that TEM specimens may be acquired from individual Zn powder particles by employing the FIB LO specimen preparation technique [3]. In this paper, we use the FIB LO technique to prepare TEM specimens from Mount Saint Helens volcanic ash.Volcanic ash from Mount Saint Helens was obtained at the Microscopy and Microanalysis 1998 meeting in Atlanta. TEM analysis of the ash was performed using the FIB lift out technique [1]. Ash powders were dusted onto an SEM sample stud that had been coated with silver paint.