The Features of Investigations and Observations of Nanoamorphous Metals and Nanocrystalline Oxides on Electron Microscope

2004 ◽  
Vol 839 ◽  
Author(s):  
R. Malkhasyan ◽  
R. Karakhanyan ◽  
M. Nazaryan ◽  
A. Khachatryan ◽  
A. Markosyan

ABSTRACTThe present paper discusses two different active influences of an electron beam on a nanosize sample.The first observed influence is the formation of nanoparticle agglomerates due to the beam charge. This can be likened to the formation of fine sand and it enables the determination of grain magnitude of the given nanomaterial. This also enables to get a clear picture of the sample, which is latent at first due to the coating of nanoparticles and their agglomerates. For example, removal of nanopowder coatings has enabled for the first time to find self - assembling systems in a shape of double chain spatial helixes from inorganic particles (as DNA).The second type of influence is related to transformations, which distort the sample. Transformation of amorphous particles of metal into a crystalline state by means of local heating is the one of most importance.Growth of thread-shaped hollow and solid nanowhiskers from nanoparticles and their further disintegration to a great number of small crystals under influence of electron beam in the chamber of electron microscope was observed. Therefore it can be confirmed that it is necessary to use an electron microscope with special precautionary measures, when working with nanoamorphous metals.

1951 ◽  
Vol 29 (2) ◽  
pp. 122-128 ◽  
Author(s):  
D. E. McLennan

Electron bombardment experiments have been carried out on small crystals of the alkali halides within the electron microscope. Crystals of two size ranges were bombarded at high intensity, and evidence of a generalized photographic effect within the ionic group of solids is presented. The first group of crystal specimens ranged in size from 0.2 to 0.002 cm., the bombardment causing the formation of F-centers and entrapped metal colloids in the crystal lattice. Ionization pulses were observed to occur in the region of the specimen during bombardment. The second group ranged in size from 10 to 0.01 μ, observations on the effects of bombardment being carried out with electron diffraction techniques. A process has been suggested to explain the phenomenon of ionic crystals which appear to lose their centers under high electron beam intensity in the electron microscope.


Author(s):  
Chester J. Calbick ◽  
Richard E. Hartman

Quantitative studies of the phenomenon associated with reactions induced by the electron beam between specimens and gases present in the electron microscope require precise knowledge and control of the local environment experienced by the portion of the specimen in the electron beam. Because of outgassing phenomena, the environment at the irradiated portion of the specimen is very different from that in any place where gas pressures and compositions can be measured. We have found that differential pumping of the specimen chamber by a 4" Orb-Ion pump, following roughing by a zeolite sorption pump, can produce a specimen-chamber pressure 100- to 1000-fold less than that in the region below the objective lens.


Author(s):  
R. C. Moretz ◽  
D. F. Parsons

Short lifetime or total absence of electron diffraction of ordered biological specimens is an indication that the specimen undergoes extensive molecular structural damage in the electron microscope. The specimen damage is due to the interaction of the electron beam (40-100 kV) with the specimen and the total removal of water from the structure by vacuum drying. The lower percentage of inelastic scattering at 1 MeV makes it possible to minimize the beam damage to the specimen. The elimination of vacuum drying by modification of the electron microscope is expected to allow more meaningful investigations of biological specimens at 100 kV until 1 MeV electron microscopes become more readily available. One modification, two-film microchambers, has been explored for both biological and non-biological studies.


Author(s):  
R. Sinclair ◽  
B.E. Jacobson

INTRODUCTIONThe prospect of performing chemical analysis of thin specimens at any desired level of resolution is particularly appealing to the materials scientist. Commercial TEM-based systems are now available which virtually provide this capability. The purpose of this contribution is to illustrate its application to problems which would have been intractable until recently, pointing out some current limitations.X-RAY ANALYSISIn an attempt to fabricate superconducting materials with high critical currents and temperature, thin Nb3Sn films have been prepared by electron beam vapor deposition [1]. Fine-grain size material is desirable which may be achieved by codeposition with small amounts of Al2O3 . Figure 1 shows the STEM microstructure, with large (∽ 200 Å dia) voids present at the grain boundaries. Higher quality TEM micrographs (e.g. fig. 2) reveal the presence of small voids within the grains which are absent in pure Nb3Sn prepared under identical conditions. The X-ray spectrum from large (∽ lμ dia) or small (∽100 Ǻ dia) areas within the grains indicates only small amounts of A1 (fig.3).


Author(s):  
J. C. Ingram ◽  
P. R. Strutt ◽  
Wen-Shian Tzeng

The invisibility criterion which is the standard technique for determining the nature of dislocations seen in the electron microscope can at times lead to erroneous results or at best cause confusion in many cases since the dislocation can still show a residual image if the term is non-zero, or if the edge and screw displacements are anisotropically coupled, or if the dislocation has a mixed character. The symmetry criterion discussed below can be used in conjunction with and in some cases supersede the invisibility criterion for obtaining a valid determination of the nature of the dislocation.The symmetry criterion is based upon the well-known fact that a dislocation, because of the symmetric nature of its displacement field, can show a symmetric image when the dislocation is correctly oriented with respect to the electron beam.


Author(s):  
W. Brünger

Reconstructive tomography is a new technique in diagnostic radiology for imaging cross-sectional planes of the human body /1/. A collimated beam of X-rays is scanned through a thin slice of the body and the transmitted intensity is recorded by a detector giving a linear shadow graph or projection (see fig. 1). Many of these projections at different angles are used to reconstruct the body-layer, usually with the aid of a computer. The picture element size of present tomographic scanners is approximately 1.1 mm2.Micro tomography can be realized using the very fine X-ray source generated by the focused electron beam of a scanning electron microscope (see fig. 2). The translation of the X-ray source is done by a line scan of the electron beam on a polished target surface /2/. Projections at different angles are produced by rotating the object.During the registration of a single scan the electron beam is deflected in one direction only, while both deflections are operating in the display tube.


Author(s):  
David Joy ◽  
James Pawley

The scanning electron microscope (SEM) builds up an image by sampling contiguous sub-volumes near the surface of the specimen. A fine electron beam selectively excites each sub-volume and then the intensity of some resulting signal is measured. The spatial resolution of images made using such a process is limited by at least three factors. Two of these determine the size of the interaction volume: the size of the electron probe and the extent to which detectable signal is excited from locations remote from the beam impact point. A third limitation emerges from the fact that the probing beam is composed of a finite number of discrete particles and therefore that the accuracy with which any detectable signal can be measured is limited by Poisson statistics applied to this number (or to the number of events actually detected if this is smaller).


Author(s):  
George Christov ◽  
Bolivar J. Lloyd

A new high intensity grid cap has been designed for the RCA-EMU-3 electron microscope. Various parameters of the new grid cap were investigated to determine its characteristics. The increase in illumination produced provides ease of focusing on the fluorescent screen at magnifications from 1500 to 50,000 times using an accelerating voltage of 50 KV.The EMU-3 type electron gun assembly consists of a V-shaped tungsten filament for a cathode with a thin metal threaded cathode shield and an anode with a central aperture to permit the beam to course the length of the column. The cathode shield is negatively biased at a potential of several hundred volts with respect to the filament. The electron beam is formed by electrons emitted from the tip of the filament which pass through an aperture of 0.1 inch diameter in the cap and then it is accelerated by the negative high voltage through a 0.625 inch diameter aperture in the anode which is at ground potential.


Author(s):  
Richard E. Hartman ◽  
Roberta S. Hartman ◽  
Peter L. Ramos

The action of water and the electron beam on organic specimens in the electron microscope results in the removal of oxidizable material (primarily hydrogen and carbon) by reactions similar to the water gas reaction .which has the form:The energy required to force the reaction to the right is supplied by the interaction of the electron beam with the specimen.The mass of water striking the specimen is given by:where u = gH2O/cm2 sec, PH2O = partial pressure of water in Torr, & T = absolute temperature of the gas phase. If it is assumed that mass is removed from the specimen by a reaction approximated by (1) and that the specimen is uniformly thinned by the reaction, then the thinning rate in A/ min iswhere x = thickness of the specimen in A, t = time in minutes, & E = efficiency (the fraction of the water striking the specimen which reacts with it).


Author(s):  
J. Edie

In TEM image formation, the observed contrast variations within thin sections result from differential electron scattering within microregions of varying mass thickness. It is possible to utilize these electron scattering properties to obtain objective information regarding various specimen parameters (1, 2, 3).A pragmatic, empirical approach is described which enables a microscopist to perform physical measurements of thickness of thin sections and estimates of local mass, volume, density and, possibly, molecular configurations within thin sections directly in the microscope. A Faraday cage monitors the transmitted electron beam and permits measurements of electron beam intensities.


Sign in / Sign up

Export Citation Format

Share Document