New Approach of Laser-SQUID Microscopy to LSI Failure Analysis

2009 ◽  
Vol E92-C (3) ◽  
pp. 327-333 ◽  
Author(s):  
Kiyoshi NIKAWA ◽  
Shouji INOUE ◽  
Tatsuoki NAGAISHI ◽  
Toru MATSUMOTO ◽  
Katsuyoshi MIURA ◽  
...  
Author(s):  
Michael Hertl ◽  
Diane Weidmann ◽  
Alex Ngai

Abstract A new approach to reliability improvement and failure analysis on ICs is introduced, involving a specifically developed tool for Topography and Deformation Measurement (TDM) under thermal stress conditions. Applications are presented including delamination risk or bad solderability assessment on BGAs during JEDEC type reflow cycles.


2018 ◽  
Vol 2 (Special edition 2) ◽  
pp. 123-132
Author(s):  
Jasminka Bonato ◽  
Martina Badurina ◽  
Julijan Dobrinić

The paper aims at presenting the FMEA method based on the fuzzy technique, representing a new approach to the failure analysis and its effects on the observed system. The FMEA (Failure Mode and Effect Analysis) method has assigned the risks a coefficient i.e. a numerical indicator that very clearly defines the degree of risk. The risk is calculated as a mathematical function of RPN which depends on the effects S, probability O that some case will lead to a failure and to a probability that a failure D can not be detected before its effects are realized. RPN = S O D. The FMEA method, based on the fuzzy logic, makes a more reliable evaluation of the observed system failures possible.


Author(s):  
Lajmi Fatma ◽  
Jalel Ghabi ◽  
Hedi Dhouibi

In this article, the authors propose a new approach for modelling and failure analysis by combining the graphical representation provided by Petri nets and fuzzy logic. The graphical method is used for describing the relationship between conditions and events. The use of Petri nets in failure analysis enables replacing logic gate functions in fault trees. The Fuzzy logic technique allows natural language descriptions of process entities as well as an if-then rule-based definition of production. In addition, this study devises an alternative, a trapezoidal graph method in order to account for failure scenarios. Examples validating this novel method in dealing with failure analysis are also provided.


Author(s):  
S.H. Lau ◽  
Wenbing Yun ◽  
Sylvia JY Lewis ◽  
Benjamin Stripe ◽  
Janos Kirz ◽  
...  

Abstract We describe a technique for mapping the distribution and concentrations of trace elements, most notably with capabilities of achieving 1-10 parts per million sensitivities within 1 second and at <8 μm resolution. The technique features an innovative, high flux microstructured x-ray source and a new approach to x-ray optics comprising a high efficiency twin paraboloidal x-ray mirror lens. The resulting ability to acquire dramatically higher sensitivities and resolution than conventional x-ray fluorescence approaches, and at substantially higher throughput enables powerful compositional mapping for failure analysis, process development, and process monitoring.


2012 ◽  
Vol 52 (9-10) ◽  
pp. 2135-2138
Author(s):  
Andreas Rummel ◽  
Klaus Schock ◽  
Andrew Smith ◽  
Stephan Kleindiek

2016 ◽  
Author(s):  
Christopher Nemirow ◽  
Neel Leslie

Abstract LVx, a workhorse in many failure analysis laboratories, consists of laser voltage imaging (LVI) and laser voltage probing. Laser voltage tracing (LVT) eliminates the inherent restrictions bestowed by LVI and reduces the need for costly probing. It monitors a distinct feature of the test pattern and creates a corresponding signal map. This weapon in the LVx arsenal significantly decreases debug time and will prove as invaluable as LVI. Beginning with an overview of the limitations of traditional LVx, this paper provides information on the process steps, experimental setup, and applications of LVT. LVT introduces a new approach to monitoring LVx signals. The most obvious LVT application is debugging problematic peripheral NAND circuitry.


Author(s):  
Guillaume Celi ◽  
Sylvain Dudit ◽  
Thierry Parrassin ◽  
Michel Vallet ◽  
Philippe Perdu ◽  
...  

Abstract The Laser Voltage Imaging (LVI) technique [1], introduced in 2009, appears as a very promising approach for Failure Analysis application which allows mapping frequencies through the backside of integrated circuits. In this paper, we propose a new range of application based on the study of the LVI second harmonic for signal degradation analysis. After a theoretical study of the impact of signal degradation on the second harmonic, we will demonstrate the interest of this new approach on two case studies on ultimate technology (28nm). This technique is a new approach of failure analysis that maps timing degradation and duty cycle degradation. In order to confirm the degradations we will use the LVP Technique. The last part is two real case studies on which this LVI second harmonic technique was used to find the root cause of a 28nm process issue.


Author(s):  
F. Hapke ◽  
M. Keim ◽  
T. Herrmann ◽  
T. Heidel ◽  
M. Reese ◽  
...  

Abstract This paper describes a new approach for quickly ramping up the yield for new CMOS technologies by performing a cell-internal (CI) diagnosis based on the cell-aware (CA) methodology. We present results from carrying out this new method on a test chip of a 28-nm technology. After creating defect-oriented CA test patterns for this test chip, we tested various wafers with those CA patterns, selected fail data, conducted a normal electrical failure analysis, and used the new CI diagnosis method to guide the physical failure analysis (PFA) process to look specifically for hot-spot areas within standard library cells. This new approach can reduce the yield ramp-up time significantly.


Sign in / Sign up

Export Citation Format

Share Document