scholarly journals A Novel Dual-Band Conformal Surface Plasmons Waveguide With Tunable Frequency Response In Large-scale

Author(s):  
Yijiao Fang ◽  
Jiangwei Zhong

Abstract A novel dual-band conformal surface plasmons (CSPs) waveguide is designed and well studied in this paper. In earlier researches, we have recognized that electromagnetic field of CSPs waveguide are always confined to a sub-wavelength area and have a strong potential to be applied in devices designing. However, almost all of the earlier CSP structures is mainly focus on the fundamental mode characteristics with only single resonance frequency. Here we propose a innovative dual inverted-L structure with excellent performance not only on the fundamental mode but also on a new upper mode. This structure operates in microwave frequencies regime and shows outstanding frequency tunability characteristic. Being different from frequency characteristics in the earlier CSP waveguides which always used to be designed single-frequency device, dual-frequency tunability can be obtained via the dual L-type bending branch of the periodical CSP structure. In present paper, we also realize a tunable dual-frequency filter by changing the scaling factor of inverted-L stubs.

2016 ◽  
Vol 9 (4) ◽  
pp. 843-850 ◽  
Author(s):  
Dinesh Kumar Singh ◽  
Binod Kumar Kanaujia ◽  
Santanu Dwari ◽  
Ganga Prasad Pandey ◽  
Sandeep Kumar

The design and measurement of reconfigurable circularly polarized capacitive fed microstrip antenna are presented. Small isosceles right angle triangular sections are removed from diagonally opposite corners for the generation of circular polarization (CP) of axial ratio bandwidth of 11.1%. Horizontal slits of different lengths are inserted at the edges of the truncated patch to provide the dual-band CP and by switching PIN diodes across the slits ON and OFF, reconfigurable circularly polarized antenna is realized. The antenna shows dual-band behavior with reconfigurable CP. In order to enhance the operation bandwidth of the antenna, an inclined slot was embedded on the patch along with PIN diodes across the horizontal slits. This proposed antenna gave an impedance bandwidth of 66.61% (ON state) ranging from 4.42 to 8.80 GHz and 68.42% (OFF state) ranging from 4.12 to 8.91 GHz and exhibits dual-frequency CP with PIN diode in OFF state and single-frequency CP with PIN diode in ON state with good axial ratio bandwidth. The axial ratio bandwidth of 4.42, 2.35, and 2.72% is obtained from the antenna. The antenna has a similar radiation pattern in all the three different CP bands and almost constant gain within the bands of CP operation.


Energies ◽  
2020 ◽  
Vol 14 (1) ◽  
pp. 71
Author(s):  
Volodymyr Gursky ◽  
Igor Kuzio ◽  
Pavlo Krot ◽  
Radoslaw Zimroz

The low energy efficiency and excessive power of electric motors of large-scale vibrating machines for processing bulk materials motivated a new design of the inertial drive. This drive consists of one motor and two coaxial unbalanced masses, whose rotational frequencies are related in the ratio 2:1. This approach allows for a generation of the excitation force with variable amplitude and frequency, which changes depending on the inertial characteristics and shaft rotation frequency and does not relate to the phase difference of the unbalanced masses. Because of this, the symmetry axis of the resulting vector hodograph can be changed. The spectral composition of the exciting force up to 200 Hz contains higher harmonics, the energy share of which is 25.4% from the 2nd harmonic and 14.1% from the 3rd and higher harmonics that correspondingly improves bulk material treatment in comparison to single-frequency vibrators. The finite element model is used for checking the strength capacity of the most loaded units of a dual-frequency drive. Its use allows the realization of complex trajectories of motion that are more technologically efficient for variable parameters of the treated media and energy saving in sieving screens and other vibrating machines.


2021 ◽  
Vol 11 (2) ◽  
pp. 699
Author(s):  
Worapol Tangsopa ◽  
Jatuporn Thongsri

At present, development of manufacturer’s ultrasonic cleaning tank (UCT) to match the requirements from consumers usually relies on computer simulation based on harmonic response analysis (HRA). However, this technique can only be used with single-frequency UCT. For dual frequency, the manufacturer used information from empirical experiment alongside trial-and-error methods to develop prototypes, resulting in the UCT that may not be fully efficient. Thus, lack of such a proper calculational method to develop the dual frequency UCT was a problem that greatly impacted the manufacturers and consumers. To resolve this problem, we proposed a new model of simulation using transient dynamics analysis (TDA) which was successfully applied to develop the prototype of dual frequency UCT, 400 W, 18 L in capacity, eight horn transducers, 28 and 40 kHz frequencies for manufacturing. The TDA can indicate the acoustic pressure at all positions inside the UCT in transient states from the start to the states ready for proper cleaning. The calculation also reveals the correlation between the positions of acoustic pressure and the placement positions of transducers and frequencies. In comparison with the HRA at 28 kHz UCT, this TDA yielded the results more accurately than the HRA simulation, comparing to the experiments. Furthermore, the TDA can also be applied to the multifrequency UCTs as well. In this article, the step-by-step development of methodology was reported. Finally, this simulation can lead to the successful design of the high-performance dual frequencies UCT for the manufacturers.


Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3803
Author(s):  
Chan-Mi Song ◽  
Hong-Jun Lim ◽  
Son Trinh-Van ◽  
Kang-Yoon Lee ◽  
Youngoo Yang ◽  
...  

In this paper, a dual-band RF wireless power transfer (WPT) system with a shared-aperture dual-band Tx array antenna for 2.4 and 5.8 GHz is proposed. The final configuration of the Tx array, which is made up of 2.4 GHz right-handed circular polarization (RHCP) patches and 5.8 GHz RHCP patches, is derived from the optimization of 2.4 and 5.8 GHz thinned arrays, ultimately to achieve high transmission efficiency for various WPT scenarios. The dual-band RF WPT Tx system including the Tx array antenna and a Tx module is implemented, and Rx antennas with a 2.4 GHz patch, a 5.8 GHz patch, and a dual-band (2.4 and 5.8 GHz) patch are developed. To validate the proposed dual-band RF WPT system, WPT experiments using a single band and dual bands were conducted. When transmitting RF wireless power on a single frequency (either 2.482 GHz or 5.73 GHz), the received power according to the distance between the Tx and Rx and the position of the Rx was measured. When the distance was varied from 1 m to 3.9 m and the transmitted power was 40 dBm, the received power value at 2.482 GHz and 5.73 GHz were measured and found to be 24.75–13.5 dBm (WPT efficiency = 2.985–0.224%) and 19.25–6.8 dBm (WPT efficiency = 0.841–0.050%), respectively. The measured results were in good agreement with the calculated results, and it is revealed that the transmission efficiency when wireless power is transmitted via beam-focusing increases more than that with conventional beam-forming. Furthermore, the dual-band WPT experiment proves that 2.482 GHz beam and 5.73 GHz beams can be formed individually and that their wireless power can be transmitted to a dual-band Rx or two different Rx.


1988 ◽  
Vol 133 ◽  
pp. 461-464
Author(s):  
O.J. Sovers ◽  
C.D. Edwards ◽  
C.S. Jacobs ◽  
G.E. Lanyi ◽  
R.N. Treuhaft

Intercontinental dual-frequency radio interferometric measurements were carried out during 1978 to 1985 between NASA's Deep Space Network stations in California, Spain, and Australia. Analysis of 6800 pairs of delay and delay rate observations made during 51 sessions produced a catalog of positions of 106 extragalactic radio sources, fairly uniformly distributed over the celestial sphere between −45° and +85° declination. Almost all of the resulting source positions have formal uncertainties between 0.5 and 3 milliarcseconds, with their distributions peaking somewhat below 1 mas. Root-mean-square uncertainties are 2.1 and 2.0 mas for RA and declination, respectively. Evidence is found for a long-term drift of the Earth's rotation axis in inertial space, relative to the 1984 IAU precession and nutation models. Tests for time variability of positions of 32 frequently observed sources place limits at the 1 mas/yr level. Comparisons with independently determined source catalogs of comparable quality show differences of positions of common sources that amount to a few mas, and may indicate the level of systematic errors in VLBI source position measurements.


Sensors ◽  
2019 ◽  
Vol 19 (9) ◽  
pp. 2189 ◽  
Author(s):  
Qiong Wu ◽  
Mengfei Sun ◽  
Changjie Zhou ◽  
Peng Zhang

The update of the Android system and the emergence of the dual-frequency GNSS chips enable smartphones to acquire dual-frequency GNSS observations. In this paper, the GPS L1/L5 and Galileo E1/E5a dual-frequency PPP (precise point positioning) algorithm based on RTKLIB and GAMP was applied to analyze the positioning performance of the Xiaomi Mi 8 dual-frequency smartphone in static and kinematic modes. The results showed that in the static mode, the RMS position errors of the dual-frequency smartphone PPP solutions in the E, N, and U directions were 21.8 cm, 4.1 cm, and 11.0 cm, respectively, after convergence to 1 m within 102 min. The PPP of dual-frequency smartphone showed similar accuracy with geodetic receiver in single-frequency mode, while geodetic receiver in dual-frequency mode has higher accuracy. In the kinematic mode, the positioning track of the smartphone dual-frequency data had severe fluctuations, the positioning tracks derived from the smartphone and the geodetic receiver showed approximately difference of 3–5 m.


Sign in / Sign up

Export Citation Format

Share Document