Faecal indicator bacteria in river biofilms

2010 ◽  
Vol 61 (5) ◽  
pp. 1105-1111 ◽  
Author(s):  
M. Balzer ◽  
N. Witt ◽  
H.-C. Flemming ◽  
J. Wingender

Biofilms in surface waters primarily consist of allochthonous microorganisms. Under conditions of pollution faecally derived bacteria may interact with these biofilms. Total coliform bacteria, Escherichia coli and intestinal enterococci are used to monitor source water quality, indicating faecal pollution and the possible presence of enteric pathogens. In the present study the occurrence of faecal indicators was investigated in biofilms (epilithic biofilms, sediments) of German rivers. All of the biofilms contained significant concentrations of these bacteria, which were several orders of magnitude lower compared with the total cell number and the number of culturable heterotrophic plate count bacteria indicating that faecal indicator bacteria represented a minor fraction of the whole biofilm communities. The biofilms displayed approximately two orders of magnitude higher concentrations of total coliforms, E. coli and enterococci compared with the overlying water. Identification of coliform and enterococcal isolates from the biofilms revealed the presence of species which are known to be opportunistic pathogens. Overall, the results of the present study show that faecal indicator bacteria can survive in the presence of high cell densities of the authochthonous microflora in epilithic biofilms and sediments, suggesting that these biofilms may act as a reservoir for bacterial pathogens in polluted rivers.

2016 ◽  
Vol 10 (1) ◽  
pp. 13-23 ◽  
Author(s):  
Agustina Arianita Cahyaningtyas ◽  
Wiwik Pudjiastuti ◽  
Ilham Ramdhan

One attempt to reduce the number of pathogenic microbes in milk is through the pasteurization process. This research aims to determine the effect of storage temperature on the organoleptic, acidity (pH) and growth of coliform bacteria in pasteurized milk. Pasteurized milk is stored at the varies of temperature  4°C (observed for 14 days), 10°C-15°C (observed for 14 days) and 25°C-27°C (observed for 22 hours), as well as also conducted an initial analysis pasteurized milk. The parameters were observed among other organoleptic (smell, taste, color, texture), pH and total coliform bacteria. Testing acidity using pH paper, while the growth of coliform bacteria testing done using Total Plate Count method based on ISO 2897 in 2008. The results of this study indicate that storage at 4°C for 14 days, organoleptic pasteurized milk is still good until the day ke- 8, pH progressively decreases, and the growth of coliform bacteria obtained the highest score of 3100x101 CFU / ml. Storage at 10°C-15°C for 14 days, organoleptic pasteurized milk is still good until the 6th day, the pH progressively decreases, and the growth of coliform bacteria obtained the highest score of 5729x101 CFU / ml. Storage at 25°C-27°C for 22 days, organoleptic pasteurized milk is still good until the 9th, pH progressively decreases, and the growth of coliform bacteria obtained the highest score of 4.3 x106 CFU / ml.ABSTRAKSalah satu usaha untuk mengurangi jumlah mikroba patogen pada susu adalah melalui proses pasteurisasi. Penelitian ini bertujuan untuk mengetahui pengaruh suhu penyimpanan terhadap organoleptik, derajat keasaman (pH) dan pertumbuhan bakteri Coliform pada susu pasteurisasi. Susu pasteurisasi disimpan pada suhu yang bervariasi yaitu suhu 4°C (diamati selama 14 hari), suhu 10°C-15°C (diamati selama 14 hari) dan suhu 25°C-27°C (diamati selama 22 jam), serta dilakukan pula analisa awal susu pasteurisasi. Parameter yang diamati antara lain organoleptik (bau, rasa, warna, tekstur), pH dan jumlah bakteri Coliform. Pengujian derajat keasaman menggunakan kertas pH, sedangkan pengujian pertumbuhan bakteri Coliform dilakukan dengan menggunakan metode Total Plate Count berdasarkan SNI 2897 Tahun 2008. Hasil penelitian ini menunjukkan bahwa penyimpanan pada suhu 4°C selama 14 hari, organoleptik susu pasteurisasi masih baik sampai dengan hari ke-8, pH semakin lama semakin menurun, dan pertumbuhan bakteri Coliform didapatkan nilai tertinggi sebesar 3100x101 Cfu/ml. Penyimpanan pada suhu 10°C-15°C selama 14 hari, organoleptik susu pasteurisasi masih baik sampai hari ke-6, pH semakin lama semakin menurun, dan pertumbuhan bakteri Coliform didapatkan nilai tertinggi sebesar 5729x101 Cfu/ml. Penyimpanan pada suhu 25°C-27°C selama 22 hari, organoleptik susu pasteurisasi masih baik sampai jam ke-9, pH semakin lama semakin menurun, dan pertumbuhan bakteri Coliform didapatkan nilai tertinggi sebesar 4,3 x106 Cfu/ml.Kata kunci : bakteri coliform, derajat keasaman, suhu penyimpanan, organoleptik, susu pasteurisasi


2020 ◽  
Vol 10 (2) ◽  
pp. 298-308
Author(s):  
Carlos I. Gonzalez ◽  
John Erickson ◽  
Karina A. Chavarría ◽  
Kara L. Nelson ◽  
Amador Goodridge

Abstract Safe water storage is critical to preserve water quality, especially when intermittent piped drinking water supply creates a need for household storage. This study characterized household storage practices and stored water quality in 94 households (N = 94) among four peri-urban neighborhoods in Arraiján, Panama with varying degrees of supply intermittency. We found that 18 (19.1%) households stored drinking water in unsafe containers. Forty-four (47%) samples of household stored drinking water had residual chlorine levels <0.2 mg/L. While 33 (35.1%) samples were positive for total coliform bacteria, only 23 (24.4%) had >10 most probable number (MPN)/100 mL total coliform bacteria. Eight (44%) samples were positive for Escherichia coli, whereas only one (1.3%) sample from the safe containers was positive. Twenty-nine (30.9%) samples had >500 MPN/mL heterotrophic plate count bacteria. These findings suggest that longer supply interruptions were associated with longer storage times and lower chlorine residual, which were associated with higher concentrations of indicator bacteria. This is one of the first studies in the Central-American region to show an association between the lack of turnover (replacement with fresh water) and greater contamination during household water storage. Thus, when drinking water supply is not completely continuous and household storage is required, decreasing the time between supply periods can facilitate safer water storage. Public awareness and education are also recommended to increase hygiene practices during water collection and storage.


2005 ◽  
Vol 23 (1) ◽  
pp. 48
Author(s):  
A A M Hatha ◽  
K S Christi ◽  
R Singh ◽  
S Kumar

Forty samples of freshwater clam (Batissa violacea), popularly known as Kai, collected from the Suva market were analysed for total aerobic plate count and total coliforms. The heterotrophic bacteria isolated by plate count were also characterised up to genera. The results indicated higher than acceptable level of plate count and coliform bacteria. While total plate count of aerobic heterotrophic bacteria ranged from 5.5 x 105 colony forming units (cfu) per gram to more than 107 cfu/ gram, total coliform load varied between 1.1 x 104 to 1.1 x 105 per 100 gm of Kai flesh. The characterisation of the heterotrophic bacteria revealed the predominance of the genera Micrococcus (34%) and Bacillus (24%). Other genera encountered included Acinetobacter, Vibrio, Aeromonas, Alcaligenes, Pseudomonas, Streptococcus and members of the family Enterobacteriaceae. The results revealed the need for depuration of the Kai in clean running water to reduce the bacterial load to acceptable levels. Temperature control soon after harvesting by proper icing and thorough cooking of the Kai before consumption is also recommended.


2013 ◽  
Vol 5 (1) ◽  
Author(s):  
Lies Indah Sutiknowati

The objective of this research was to evaluate waters quality in Pari island waters for aquaculture purpose based on bacteriological information conducted in Mei and September 2011. Microbiological parameters analyzed were total density of bacteria for coliforms, E.coli, pathogenic, heterotrophic, halotoleran, phosphate-nitrate-ammonia breaker, and total cells. Method to analyze coliform bacteria was filtration, identification of pathogenic bacteria using biochemical test, density analises for heterotrophic bacteria, analises for phosphate-nitrate-ammonia breaker bacteria using pour plate, and total cell using Acridine Orange Epifluorescence Microscopy. Results showed that the abundance of total coliform cell was about 1000-7000 colony forming unit (cfu)/100 ml. The abundance of heterotrophic, halotolerant, phosphate-nitrate-ammonia bacteria in seawater was (3.6-4.3)x105 cfu/ml, (1.1-1.3)x105 cfu/ml, (0.5-3.44)x103cfu/ml; and (3.6-6.7)x105 cfu/ml, (1.6-2.7)x105 cfu/ml, (0.6-5.22)x103 cfu/ml in sediment, respectively. The total cell of bacteria was (0.05-2.1)x107cells/ml. The dog-conch (Strombus turturella) and blood-clamps (Anadara granosa) can survive in Pari Island and there was a significant increase in sea grass litter with growth average of 0.67 mm/day and 0.90 mm/day. During snails and clamps growth, there were found several genus of pathogenic bacteria such as Salmonella, Vibrio, Aeromonas, Pseudomonas, Citrobacter, Proteus, Shigella, Hafnia, and Yersinia. The results showed that Pari island waters was suitable for developing shellfish aquaculture dog conch and blood clamps. Keywords: bacteria, parameter, shellfish, aquaculture.


1995 ◽  
Vol 32 (2) ◽  
pp. 45-52 ◽  
Author(s):  
H. Z. Sarikaya ◽  
A. M. Saatçi

Total coliform bacteria have been chosen as the indicator organism. Coliform die-away experiments have been carried out in unpolluted sea water samples collected at about 100 m off the coastline and under controlled environmental conditions. The samples were transformed into one litre clean glass beakers which were kept at constant temperature and were exposed to the solar radiation. The membrane filter technique was used for the coliform analysis. The temperature ranged from 20 to 40° C and the dilution ratios ranged from 1/50 to 1/200. Coliform decay rate in the light has been expressed as the summation of the coliform decay rate in the dark and the decay rate due to solar radiation. The solar radiation required for 90 percent coliform removal has been found to range from 17 cal/cm2 to 40 cal/cm2 within the temperature range of 25 to 30° C. Applying the linear regression analysis two different equations have been given for the high (I>10 cal/cm2.hour) and low solar intensity ranges in order to determine the coliform decay rate constant as a function of the solar intensity. T-90 values in the light have been found to follow log-normal distribution with a median T-90 value of 32 minutes. The corresponding T-90 values in the dark were found to be 70-80 times longer. Coliform decay rate in the dark has been correlated with the temperature.


1996 ◽  
Vol 34 (7-8) ◽  
pp. 187-194 ◽  
Author(s):  
Tanya Gawthorne ◽  
Robyn A. Gibbs ◽  
Kuruvilla Mathew ◽  
Goen E. Ho

Coliform bacteria may not be adequate as sole indicators of recent faecal contamination in tropical waters. Salmonella spp. in particular have been found in tropical waters in the absence of traditional indicator bacteria. Remote areas without access to a laboratory have no opportunity for salmonellae analysis as portable tests are currently not available. H2S papers indicate the presence of hydrogen sulphide producing bacteria, a characteristic shared by the majority of Salmonella spp.. The potential of H2S papers to act as a presumptive test for salmonellae in the absence of coliform bacteria was assessed. Salmonella spp. grew in the H2S medium, with an optimum incubation temperature of 37°C and a recommended length of incubation for a negative result of 48 hours. The presence of high numbers of the type of noncoliform bacteria commonly found in drinking water did not affect the performance of the H2S strips. H2S papers are recommended for use in conjunction with a coliform test as a presumptive test for the presence of Salmonella spp. in drinking water.


2021 ◽  
Vol 3 (7) ◽  
Author(s):  
Alex Saturday ◽  
Thomas J. Lyimo ◽  
John Machiwa ◽  
Siajali Pamba

AbstractBackground Microbial water quality serves to indicate health risks associated with the consumption of contaminated water. Nevertheless, little is known about the microbiological characteristics of water in Lake Bunyonyi. This study was therefore undertaken to examine the spatial and temporal variations of faecal indicator bacteria (FIB) in relation to physicochemical parameters in Lake Bunyonyi. Result The FIB concentration was consistently measured during sampling months and correlated with each other showing the presumed human faecal pollution in the lake. The highest concentration values for E. coli (64.7 ± 47.3 CFU/100 mL) and enterococci (24.6 ± 32.4 CFU/100 mL were obtained in the station close to the Mugyera trading centre. On a temporal basis, the maximum values were recorded during the rainy season in October 2019 (70.7 ± 56.5 CFU/100 mL for E. coli and 38.44 ± 31.8 CFU/100 mL for enterococci. FIB did not differ significantly among the study stations (p > 0.05) but showed significant temporal variations among the months (p < 0.05) with concentrations being significantly high in wet season than dry season (U = 794, p < 0.0001 for E. coli; U = 993.5, p = 0.008 for enterococci). Spearman’s rank correlation revealed that FIB concentrations were significantly positively correlated with turbidity and DO concentration levels (p < 0.05). Approximately 97.2% of the water samples had E. coli and enterococci concentrations levels below USEPA threshold for recreational waters. Likewise, 98.1 and 90.7% of samples recorded E. coli and enterococci counts exceeding the UNBS, APHA, WHO and EU threshold values for drinking water. Conclusion The FIB counts show that the Lake Bunyonyi water is bacteriologically unsuitable for drinking unless it is treated since the FIB pose health risks to consumers. Besides, the water can be used for recreational purposes.


2018 ◽  
Vol 53 (1) ◽  
pp. 77-82
Author(s):  
MA Riaz ◽  
B Ijaz ◽  
A Riaz ◽  
M Amjad

Present study aim to investigate application of microalgae for improvement of physiochemical parameters of waste water and improvement of treatment process through reducing the pollutant concentrations including coliform bacteria through their ability to uptake nutrients. Aquatic cultures were conducted in container with dimensions of 1.5×3sq ft. and wastewater samples 5 Litre samples were collected in plastic cans from Sukhnar drain and algal samples were collected from Bhaini Sigyain Village near Ravi Siphon, Lahore. The one experimental treatment lasted for 10 days to make 50% 5 liter water added concentration and 200g of inocula of algae were grown in wastewater container for experiments to optimize at room temperature as local outdoor cultures conditions for wastewater treatment. Total experiment repeated thrice and completed in 30 days. Results show that treatments improved the physiochemical parameter after week. Turbidity (NTU), total suspended solids (mg/L), total dissolved solids (mg/L), nitrate (mg/L), phosphate (mg/L) decrease (P < 0.05) after treatment. However, pH not significantly decreases (P≥ 0.05) pre-treatment values 6.56±0.05 (mg/L) and post-treatment 6.53± 0.057(mg/L). Maximum total coliform disinfection (P < 0.05) was indicated with 200 g of algae was pre-treatment 1602± 6.8 (MPN) and post treatment 1447±39.5 (MPN) observed.Bangladesh J. Sci. Ind. Res.53(1), 77-82, 2018


2017 ◽  
Vol 18 (3) ◽  
pp. 843-852
Author(s):  
Travis D. Gardner ◽  
Joe D. Guggenberger

Abstract Ceramic pot filters (CPFs) are an effective point of use water treatment device in developing nations due to their low cost and effectiveness. CPFs are gravity fed, typically making water production a major limiting factor to a CPF's lifetime and acceptability. Directly connecting CPFs to in-line pumping systems or systems with an elevated storage tank would allow filter usage for constant water treatment at increased pressures, increasing the quantity of treated water. Ceramic disks were manufactured for testing in a specially designed housing apparatus. Filters of varying thicknesses and clay to sawdust mass ratios were manufactured to fit tightly. Flowrate and microbiological removal efficacy (logarithmic reduction value (LRV)) were determined over the testing period at various pressures. Flowrate values ranged from 2.44 to 9.04 L per hour, significantly higher than traditional CPF technology. LRVs ranged from 1.1 to 2.0, lower than traditional CPF technology but still effective at removing most Escherichia coli and total coliform bacteria. Filters proved effective at removing total and fecal coliforms at pressures less than 70 kilopascals. The optimum filter had a thickness of 3.2 cm and clay to sawdust ratio of 6:1 by mass. Filters proved to be ineffective if flowrates were above 5 L/h.


Sign in / Sign up

Export Citation Format

Share Document