scholarly journals Optimization of active coagulant agent extraction method from Moringa Oleifera seeds for municipal wastewater treatment

Author(s):  
Raouf Bouchareb ◽  
Kerroum Derbal ◽  
Abderrezzak Benalia

Abstract An enhanced and different method for the active coagulant agent extraction from Moringa Oleifera seeds powder (MOSP) was established and compared to the conventional extraction method in distillate water. In the improved method, MOSP were extracted using sodium chloride as solvent at different concentrations to extract more coagulant agent from Moringa Oleifera and enhance coagulation activity. In this study, MOSP were initially processed and oil content was removed to minimize coagulant concentration usage (MOSP-EO). Moringa Oleifera seeds powder was characterized by both X-ray and FTIR analysis. Ultrasound treatment as well was considered as an additional treatment for MOSP-EO to investigate its effect on coagulant agent extraction process improvement. Coagulation/flocculation experiments were conducted to assess coagulant extraction performance realized through various conditions. The effect of coagulant dosage, solvent concentration and ultrasound exposition duration were investigated for a real effluent of municipal wastewater treatment. Among the three studied NaCl concentrations, 1.0 M was found to be the best solvent concentration for high turbidity removal of more than 97% using 140 mg/L of MOSP-EO compared to extraction in distillate water 88% using 170 mg/L of the same coagulant. NaCl 1.0 M demonstrated the best performance in biochemical oxygen demand (BOD5) removal as well, where more than 98% of municipal wastewater initial BOD5 was eliminated. Mixing MOSP-EO assisted with ultrasound waves at different treatment periods did decrease the active coagulant agent extraction and thus showed its inconvenient for Moringa Oleifera coagulation activity usage.

Author(s):  
Klaus Doelle ◽  
Qian Wang

The study tested a designed and built pilot scale packed bio-tower system under continuous operation using pre-clarified municipal wastewater. Performance was evaluated by measuring the removal of chemical oxygen demand and nitrogen ammonia. The pilot scale packed bio-tower system had a diameter of 1209 mm (4 ft.) and a height of 3,962 mm (13 ft.) and contained Bentwood CF-1900 bacteria growth media with a surface area of 6,028.80 ft² (560.09 m²). The municipal residential sewage was fed into a 1,481 l (375 gal.) recirculation reservoir at a temperature of 15°C (59.0°F) and a flow rate between 7,571 l/d (2000 gal/d) and 90,850 l/d (24,000 gal/d) and recirculated through the bio-tower with a fixed recirculation rate of 75.7 l/min (20 gal/min). The influent COD value reduction achieved is between 63.4% and 84.8%, whereas the COD influent value varied between 87 mg/l and 140 mg/l. The influent NH3-N reduction achieved was between 99.8% and 91.8% whereas the influent NH3-N value was between 28.8 mg/l and 18.6 mg/l  at a flow rate between 7571 l/d (2000 gal/d) and 90,850 l/d (24,000 gal/d).


2017 ◽  
Vol 10 (4) ◽  
pp. 1918 ◽  
Author(s):  
Cheikhou Kane ◽  
Aïcha Bâ ◽  
Seïd Ali Malloum Mahamat ◽  
Nicolas Ayessou ◽  
Maryam Khadim Mbacké ◽  
...  

2020 ◽  
Vol 15 (2) ◽  
pp. 515-527
Author(s):  
L. Desa ◽  
P. Kängsepp ◽  
L. Quadri ◽  
G. Bellotti ◽  
K. Sørensen ◽  
...  

Abstract Many wastewater treatment plants (WWTP) in touristic areas struggle to achieve the effluent requirements due to seasonal variations in population. In alpine areas, the climate also determines a low wastewater temperature, which implies long sludge retention time (SRT) needed for the growth of nitrifying biomass in conventional activated sludge (CAS). Moreover, combined sewers generate high flow and dilution. The present study shows how the treatment efficiency of an existing CAS plant with tertiary treatment can be upgraded by adding a compact line in parallel, consisting of a Moving Bed Biofilm Reactor (MBBR)-coagulation-flocculation-disc filtration. This allows the treatment of influent variations in the MBBR and a constant flow supply to the activated sludge. The performance of the new 2-step process was comparable to that of the improved existing one. Regardless significant variations in flow (10,000–25,000 m3/d) and total suspended solids (TSS) (50–300 mg/L after primary treatment) the effluent quality fulfilled the discharge requirements. Based on yearly average effluent data, TSS were 11 mg/L, chemical oxygen demand (COD) 27 mg/L and total phosphorus (TP) 0.8 mg/L. After the upgrade, ammonium nitrogen (NH4-N) dropped from 4.9 mg/L to 1.3 mg/L and the chemical consumption for phosphorus removal was reduced.


2018 ◽  
Vol 77 (9) ◽  
pp. 2242-2252 ◽  
Author(s):  
M. Vaccari ◽  
P. Foladori ◽  
S. Nembrini ◽  
F. Vitali

Abstract One of the largest surveys in Europe about energy consumption in Italian wastewater treatment plants (WWTPs) is presented, based on 241 WWTPs and a total population equivalent (PE) of more than 9,000,000 PE. The study contributes towards standardised resilient data and benchmarking and to identify potentials for energy savings. In the energy benchmark, three indicators were used: specific energy consumption expressed per population equivalents (kWh PE−1 year−1), per cubic meter (kWh/m3), and per unit of chemical oxygen demand (COD) removed (kWh/kgCOD). The indicator kWh/m3, even though widely applied, resulted in a biased benchmark, because highly influenced by stormwater and infiltrations. Plants with combined networks (often used in Europe) showed an apparent better energy performance. Conversely, the indicator kWh PE−1 year−1 resulted in a more meaningful definition of a benchmark. High energy efficiency was associated with: (i) large capacity of the plant, (ii) higher COD concentration in wastewater, (iii) separate sewer systems, (iv) capacity utilisation over 80%, and (v) high organic loads, but without overloading. The 25th percentile was proposed as a benchmark for four size classes: 23 kWh PE−1 y−1 for large plants > 100,000 PE; 42 kWh PE−1 y−1 for capacity 10,000 < PE < 100,000, 48 kWh PE−1 y−1 for capacity 2,000 < PE < 10,000 and 76 kWh PE−1 y−1 for small plants < 2,000 PE.


2013 ◽  
Vol 20 (1) ◽  
pp. 199-208 ◽  
Author(s):  
Marketa Julinova ◽  
Jan Kupec ◽  
Roman Slavik ◽  
Maria Vaskova

Abstract A synthetic polymer, polyvinylpyrrolidone (PVP - E 1201) primarily finds applications in the pharmaceutical and food industries due to its resistance and zero toxicity to organisms. After ingestion, the substance passes through the organism unchanged. Consequently, it enters the systems of municipal wastewater treatment plants (WWTP) without decomposing biologically during the waste treatment process, nor does it attach (through sorption) to particles of activated sludge to any significant extent, therefore, it passes through the system of a WWTP, which may cause the substance to accumulate in the natural environment. For this reason the paper investigates the potential to initiate aerobic biodegradation of PVP in the presence of activated sludge from a municipal wastewater treatment plant. The following agents were selected as the initiators of the biodegradation process - co-substrates: acrylamide, N-acethylphenylalanine and 1-methyl-2-pyrrolidone, a substance with a similar structure to PVP monomer. The biodegradability of PVP in the presence of co-substrates was evaluated on the basis of biological oxygen demand (BOD) as determined via a MicroOxymax O2/CO2/CH4 respirometer. The total substrate concentration in the suspension equaled 400 mg·dm-3, with the ratio between PVP and the cosubstrate being 1:1, while the concentration of the dry activated sludge was 500 mg·dm-3. Even though there was no occurrence of a significant increase in the biodegradation of PVP alone in the presence of a co-substrate, acrylamide appeared to be the most effective type of co-substrate. Nevertheless, a recorded decrease in the slope of biodegradation curves over time may indicate that a process of primary decomposition was underway, which involves the production of metabolites that inhibit activated sludge microorganisms. The resulting products are not identified at this stage of experimentation.


2006 ◽  
Vol 6 (4) ◽  
pp. 17-25 ◽  
Author(s):  
A. Ried ◽  
J. Mielcke

The use of ozone and/or UV for water treatment processes is often a combination of an ozone and/or UV-step with additional treatment steps, e.g. biological treatment, flocculation, filtration and activated carbon. Therefore, it is necessary to develop an optimized combination of these different steps. This article will demonstrate the advantages presenting two examples for drinking water treatment and two examples for municipal wastewater treatment.


2018 ◽  
Vol 77 (11) ◽  
pp. 2723-2732 ◽  
Author(s):  
Xiaowei Zheng ◽  
Shenyao Zhang ◽  
Jibiao Zhang ◽  
Deying Huang ◽  
Zheng Zheng

Abstract With the improvement of wastewater discharge standards, wastewater treatment plants (WWTPs) are continually undergoing technological improvements to meet the evolving standards. In this study, a quartz sand deep bed denitrification filter (DBDF) was used to purify WWTP secondary effluent, utilizing high nitrate nitrogen concentrations and a low C/N ratio. Results show that more than 90% of nitrate nitrogen (NO3-N) and 75% of chemical oxygen demand (COD) could be removed by the 20th day of filtration. When the filter layer depth was set to 1,600 mm and the additional carbon source CH3OH was maintained at 30 mg L−1 COD (20 mg L−1 methanol), the total nitrogen (TN) and COD concentrations of DBDF effluent were stabilized below 5 and 30 mg L−1, respectively. Analysis of fluorescence revealed that DBDF had a stronger effect on the removal of dissolved organic matter (DOM), especially of aromatic protein-like substances. High throughput sequencing and qPCR results indicate a distinctly stratified microbial distribution for the main functional species in DBDF, with quartz sand providing a good environment for microbes. The phyla Proteobacteria, Bacteroidetes, and Chloroflexi were found to be the dominant species in DBDF.


2020 ◽  
Vol 81 (9) ◽  
pp. 2011-2022
Author(s):  
Vallo Kõrgmaa ◽  
Mailis Laht ◽  
Riin Rebane ◽  
Erki Lember ◽  
Karin Pachel ◽  
...  

Abstract Chemical pollution poses a threat to the aquatic environment and to human health. Wastewater treatment plants are the last defensive line between the aquatic environment and emissions of pollutants. This study focuses on identification of most relevant hazardous substances in Estonian municipal wastewater and their fate in the treatment process. During this study, seasonal wastewater and sewage sludge samples were collected from nine municipal wastewater treatment plants and analyzed for 282 hazardous substances, including EU (n = 45) and Estonian (n = 31) priority substances. Results of this study show that several substances that are subject to international restrictions (e.g. Stockholm Convention) are still present in untreated sewage. Wastewater treatment systems that had a greater level of complexity (TEC >5) were more successful in removing hazardous substances. Statistical analyses showed that removal efficiency of organic hazardous substances had significant (p-value <0.05) linear correlation with removal efficiencies of chemical oxygen demand (COD) and total suspended solids (TSS), but a monotonic relationship with operators' competency. This study showed that operators' competency had a strong influence on the stability of the wastewater treatment efficiency and removal of organic hazardous substances.


2017 ◽  
Vol 76 (12) ◽  
pp. 3299-3306
Author(s):  
M. Kaless ◽  
L. Palmowski ◽  
J. Pinnekamp

Abstract The energy content of screenings from six municipal wastewater treatment plants (WWTPs) was examined. Hourly samples of separated screenings were taken over 24 hours at three of the plants to illustrate diurnal variations. To recover the chemical energy, which usually leaves the WWTP with the screenings, a screenings wash press was used to transfer organic matter from the solid into the liquid phase. The chemical energy of raw and compacted washed screenings as well as the chemical energy of washing water were determined by measuring the chemical oxygen demand (COD) for the six WWTPs. A mass weighted average of 1.35 gCOD/gdm (dm: dry matter) was found in the raw screenings of three WWTPs. The overall recovered energy from screenings was found to range from 0.27 to 0.62 gCOD/gdm. This washed-out COD found in the washing water could be sent for anaerobic digestion or to the wastewater treatment process as a carbon source for denitrification.


Sign in / Sign up

Export Citation Format

Share Document