A Novel OBIRCH Fault Isolation Method to Locate the Leakage Failure Point

Author(s):  
Chi-Lin Huang ◽  
Yu Hsiang Shu

Abstract Conventional isolation techniques, such as Optical Beam Induced Resistance Change (OBIRCH) or photoemission microscopy (PEM) frequently fail to locate failure points when only applied to power pin of the semiconductor device. In this paper, a novel OBIRCH failure isolation technique is utilized to detect leakage failures. Different test conditions are presented to identify the differences in current when all input pins are pulled high in an OBIRCH system. In order to verify a failure point, it is necessary to perform electrical analysis of the suspected failure point in the failing sample. In general, Conductive Atomic Force Microscope (C-AFM) and a Nano-Prober is sufficient to provide the electrical data required for failure analysis. Experiment results, however, prove that this novel OBIRCH failure isolation technique is effective in locating the failure point, especially for leakage failures. The failure mechanism is illustrated using cross-sectional TEM.

Author(s):  
Ryan Fredrickson ◽  
Tim Kuebrich ◽  
Andrew Le ◽  
Derek Snider ◽  
Lucas Winiarski

Abstract Fault isolation is an important initial component of the failure analysis investigation as it provides the first indicator of the defect physical location. The most broadly familiar fault isolation techniques include photoemission microscopy (PEM), optical beam induced resistance change (OBIRCH) and liquid crystal analysis (LCA). Each of these techniques has their own strengths but also drawbacks which can impede the analysis by either not providing a well isolated defect location or causing damage to the defect region. For some types of defects, photoemission and liquid crystal analysis may create local heating of the device which can distort the defect and mask the root cause of the failure. These techniques also rely on optical microscopy which has low resolution compared to the feature size of current technologies. In addition, each technique may not highlight the defect site itself; only pointing the analyst to the defective circuit within the sample. Electron Beam Induced Current (EBIC) and Electron Beam Absorbed Current (EBAC) microscopy provides solutions to these complications. In this paper we describe some very effective approaches by using these beam-based techniques in conjunction with traditional methods. As introduction, we have provided some interesting case studies whereby EBIC/EBAC have been used in conjunction with FIB circuit edits and scan diagnostic results to narrow the defect search areas. We focus the paper on some less common applications of cross sectional EBIC/EBAC as well as utilizing an AC coupled configuration to activate more subtle defect sites. We conclude with two examples where AC coupled cross-sectional EBIC is needed to highlight the cause of the failure.


Author(s):  
Lucile C. Teague Sheridan ◽  
Linda Conohan ◽  
Chong Khiam Oh

Abstract Atomic force microscopy (AFM) methods have provided a wealth of knowledge into the topographic, electrical, mechanical, magnetic, and electrochemical properties of surfaces and materials at the micro- and nanoscale over the last several decades. More specifically, the application of conductive AFM (CAFM) techniques for failure analysis can provide a simultaneous view of the conductivity and topographic properties of the patterned features. As CMOS technology progresses to smaller and smaller devices, the benefits of CAFM techniques have become apparent [1-3]. Herein, we review several cases in which CAFM has been utilized as a fault-isolation technique to detect middle of line (MOL) and front end of line (FEOL) buried defects in 20nm technologies and beyond.


Author(s):  
Frank S. Arnold

Abstract To be better prepared to use laser based failure isolation techniques on field failures of complex integrated circuits, simple test structures without any failures can be used to study Optical Beam Induced Resistance Change (OBIRCH) results. In this article, four case studies are presented on the following test structures: metal strap, contact string, VIA string, and comb test structure. Several experiments were done to investigate why an OBIRCH image was seen in certain areas of a VIA string and not in others. One experiment showed the OBRICH variation was not related to the cooling and heating effects of the topology, or laser beam focusing. A 4 point probe resistance measurement and cross-sectional views correlated with the OBIRCH results and proved OBIRCH was able to detect a variation in VIA fabrication.


Author(s):  
Brett A. Buchea ◽  
Christopher S. Butler ◽  
H.J. Ryu ◽  
Wen-hsien Chuang ◽  
Martin von Haartman ◽  
...  

Abstract A novel fault isolation technique, electron beam induced resistance change (EBIRCh), allows for the direct stimulation and localization of eBeam current sensitive defects with resolution of approximately 100nm square, continuing a history of beam based failure isolation methods. EBIRCh has been shown to work over a range of defects, significantly decreasing the time required for isolation of shorts through straightforward high resolution imagery, allowing for explicit visual defect isolation with a linear resolution of approximately 10nm. This paper discusses the operational setups for the source and amplifier while performing an EBIRCh scan, describes the processes involved in the Intel test vehicle that was used to test EBIRCh, and provides information on two independent functional theories for EBIRCh that operate in conjunction to a greater or lesser extent depending on the defect type. EBIRCh is expected to improve through-put and resolution on various defect types compared to conventional fault isolation techniques.


Author(s):  
Jim Douglass ◽  
Sohrab Pourmand

Abstract This paper shows that by combining electrical fault isolation and characterization by microprobing with physical fault isolation techniques both what is wrong with the circuit and where the defect is located can be determined with less microprobing and more safety from electrical recovery. In the first example, the unit was powered up using the optical beam induced resistance change (OBIRCH) supply, and OBIRCH was performed to determine if there were OBIRCH site differences between the good part and the return. The second example uses a combination of electrical fault isolation and characterization with microprobing and the physical fault isolation tool of lock in thermography (LIT). With these two examples, it has been shown that the use of electrical fault isolation and microprobing can be used to enhance the physical fault isolation tools of OBIRCH and LIT.


2016 ◽  
Vol 64 ◽  
pp. 321-325 ◽  
Author(s):  
P.K. Tan ◽  
H.H. Yap ◽  
C.Q. Chen ◽  
F. Rivai ◽  
Y.Z. Zhao ◽  
...  

Author(s):  
Ikuo Arata ◽  
Shigeru Sakamoto ◽  
Yoshiyuki Yokoyama ◽  
Hirotoshi Terada

Abstract SIL(Solid Immersion Lens) is well investigated for optical pickup application because of its capability of high resolution. We applied this technique to microscopy, especially for precise observation of semiconductors. And also we applied it to fault isolation techniques like emission microscopy , OBIRCH(Optical Beam Induced Resistance Change) and TIVA,SEI. We found significant enhancement of resolution and sensitvity by using SIL. Applying this technique to emission microscopy, we should be aware of optical absorption charactristics of SIL lens materials. We investigated proper SIL lens materials for emission microscopy and laser scanning applications, and checked performance of Si(Silicon)-SIL and GaP(Gallium phosphide)-SIL. We also compared combinations of some kinds of SILs and detectors like C-CCD(cooled CCD) camera, MCT(HgCdTe) camera and position sensitive detector with InGaAs photo cathode II(image intensifier).


2018 ◽  
Author(s):  
Zhi Jie Lau ◽  
Chris Philips

Abstract Thermal-Laser Signal Injection Microscopy (T-LSIM) is a widely used fault isolation technique. Although there are several T-LSIM systems on the market, each is limited in terms of the voltage and current it can produce. In this paper, the authors explain how they incorporated an Amplified External Isolated Source-Sense (AxISS) unit into their T-LSIM platform, increasing its current sourcing capability and voltage biasing range. They also provide examples highlighting the types of faults and failures that the modified system can detect.


2018 ◽  
Author(s):  
Daechul Choi ◽  
Yoonseong Kim ◽  
Jongyun Kim ◽  
Han Kim

Abstract In this paper, we demonstrate cases for actual short and open failures in FCB (Flip Chip Bonding) substrates by using novel non-destructive techniques, known as SSM (Scanning Super-conducting Quantum Interference Device Microscopy) and Terahertz TDR (Time Domain Reflectometry) which is able to pinpoint failure locations. In addition, the defect location and accuracy is verified by a NIR (Near Infra-red) imaging system which is also one of the commonly used non-destructive failure analysis tools, and good agreement was made.