scholarly journals EVALUATION OF SHAPING EFFICACY AND CANAL CENTERING ABILITY OF RECIPROCATING HANDPIECE WITH STAINLESS STEEL K FILE, NITI K FILE AND WAVEONE USING CBCT.

Author(s):  
Sundaresan Balagopal ◽  
Bahavathi Anandhan Hema Sathya ◽  
C Charanya ◽  
Vandana James ◽  
Vasudevan Navabharathy ◽  
...  

Introduction: Continuously tapered form of root canal and to maintain the original shape and position of the apical foramen is the key element in root canal treatment. However, canal curvature may cause difficulty in instrumentation. Aim: The aim of this study was to evaluate the shaping efficacy and centering ability of reciprocating handpiece with stainless steel (SS) K files and Nickel Titanium (NiTi) K files in 90 degree and WaveOne gold file system in 150 counterclockwise and 30 clockwise reciprocation using cone bean computer tomography. Materials and methods: Thirty freshly extracted human mandibular molars with fully formed apices were taken for the study and 11 mm of distal roots were used for the study. They were divided into three groups (n=10). All the three groups were instrumented using reciprocating handpiece. The file system used for Group 1, 2 and 3 are SS k file, NiTi K files, and WaveOne gold file respectively. Statistical analysis: Data was tabulated and One-way analysis of variance (ANOVA) followed by Tukey post hoc honestly significant difference (HSD) test were conducted at p=0.05 significance. Results: The results revealed significant variations in shaping efficacy and centering ability at various level by all the three file system. A good canal taper and improved shaping efficacy was significantly reported in favor of WaveOne gold reciprocating file. Conclusion: The WaveOne Gold showed better shaping ability whereas the canal centering ability at the coronal, middle and the apical third were not found uniform for the three tested instrument. Keywords: Shaping efficacy, Canal centering, reciprocating handpiece, NiTi files, WaveOne Gold, CBCT

2019 ◽  
Vol 13 (1) ◽  
pp. 57-60
Author(s):  
Damla Özsu Kırıcı ◽  
Ertuğrul Karataş ◽  
Ahmet Demirhan Uygun ◽  
Ezgi Doğanay Yıldız ◽  
Kezban Meltem Çolak ◽  
...  

Background. The aim of the present study was to compare the cyclic fatigue resistance of novel nickel titanium rotary pathfinding instruments. Methods. Twenty instruments were selected for each file system. A simulated stainless steel root canal, with a 90° angle of curvature and a curvature radius of 3 mm, was used for cyclic fatigue test of the ProGlider (#16, progressive taper: 0.02‒ 0.085), PathGlider (#15, taper: .03), and One G (#14, taper: .03) instruments. Statistical analyses were performed with oneway ANOVA (P=0.05). Post hoc Tukey tests were used to determine any statistically significant differences between the groups. Results. The ProGlider instruments exhibited significantly more cyclic fatigue resistance than both PathGlider and One G instruments (P<0.001). One G instruments had significantly more resistance to fracture than PathGlider instruments (P<0.05). Conclusion. ProGlider instruments had better cyclic fatigue resistance than PathGlider and One G instruments.


2019 ◽  
Vol 13 (02) ◽  
pp. 243-247
Author(s):  
Mirjana L. Paunovska ◽  
Nichola J. Coleman ◽  
Marija M. Stevanovic ◽  
Aleksandar G. Dimkov ◽  
Dragana Gabric ◽  
...  

Abstract Objective The aim of this study is to determine the effect of the addition of benzalkonium chloride and cetylpyridinium chloride in three commercial root canal sealers. Materials and Methods Three different root canal sealers were used: EndoRez, N2, and Apexit Plus. The samples were prepared by mixing the components according to the manufacturers’ guidelines and adding 2% in weight of the antimicrobials to the newly mixed cement. The paste was placed in molds and stored in an incubator (37°C, 24 h). The samples were then stored in 5-mL distilled water. Samples without antimicrobials served as a control. All samples were tested at 3 time intervals: 1 day, 1 week, and 1 month following their storage in distilled water. The impact of the antimicrobials on the solubility of the sealers, the release of chloride ions (Cl—), and the pH value were examined. Statistical Analysis Analysis was done using one-way analysis of variance and the post hoc Tukey's honestly significant difference test. Results Chloride ions are present in storage media with EndoRez, N2, and Apexit Plus samples (without antimicrobials) following all tested storage intervals. The addition of the antimicrobials increased the release of chloride ions. Endodontic cements without addition of antimicrobials show an increase in weight after 1 month. The highest pH value is measured in Apexit Plus samples. The solutions in which N2 samples (with and without addition of antimicrobials) were stored did not have a significant change in their pH, while in the EndoRez solutions, a significant decrease in the pH value after the first week was measured. Conclusions The addition of antimicrobials might lead to improved characteristics of the root canal sealers.


2016 ◽  
Vol 10 (02) ◽  
pp. 220-224 ◽  
Author(s):  
Emre Bayram ◽  
Huda Melike Bayram

ABSTRACT Objective: The purpose of this study was to evaluate fracture resistance of teeth with immature apices treated with coronal placement of mineral trioxide aggregate (MTA), bioaggregate (BA), and Biodentine. Materials and Methods: Forty-one freshly extracted, single-rooted human premolar teeth were used for the study. At first, the root length was standardized to 9 mm. The crown-down technique was used for the preparation of the root canals using the rotary ProTaper system (Dentsply Maillefer, Ballaigues, Switzerland) of F3 (30). Peeso reamer no. 6 was stepped out from the apex to simulate an incompletely formed root. The prepared roots were randomly assigned to one control (n = 5) and three experimental (n = 12) groups, as described below. Group 1: White MTA (Angelus, Londrina, Brazil) was prepared as per the manufacturer's instructions and compacted into the root canal using MAP system (Dentsply Maillefer, Ballaigues, Switzerland) and condensed by pluggers (Angelus, Londrina, Brazil). Group 2: The canals were filled with DiaRoot-BA (DiaDent Group International, Canada). Group 3: Biodentine (Septodont, Saint Maur des Fosses, France) solution was mixed with the capsule powder and condensed using pluggers. Instron was used to determine the maximum horizontal load to fracture the tooth, placing the tip 3 mm incisal to the cementoenamel junction. Mean values of the fracture strength were compared by ANOVA followed by a post hoc test. P < 0.05 was considered statistically significant. Results: No significant difference was observed among the MTA, BA, and biodentine experimental groups. Conclusion: All the three materials tested, may be used as effective strengthening agents for immature teeth.


2021 ◽  
Vol 11 (Suppl. 1) ◽  
pp. 67-73
Author(s):  
Ahmet Akay ◽  
Özkan Adıgüzel ◽  
Seda Erkan Akay ◽  
Sadullah Kaya

Aim: The purpose of this in vitro study is to compare the cyclic fatigue resistance of Reciproc Nickel-Titanium (Ni-Ti) rotary files while operating root canals using in three different reciprocal angles. Methodology: Forty-five pieces of Reciproc R25 canal files were tested using artificial canals with a 60° angle of curvature, 5 mm curvature radius, and 1.5 mm diameter carved into a stainless steel block. The Ni-Ti files were checked with a stereomicroscope and then randomly separated into 3 groups. Group 1 consisted of reciprocal angles CCW 150°–CW 30°, Group 2 consisted of CCW 180°–CW 60°, and Group 3 consisted of CCW 210°–CW 90°. The duration of the cyclic fatigue being measured, elapsed time until a file fractured was determined with a chronometer. The lengths of the fractured pieces were measured with a digital caliper. After the cyclic fatigue test, two samples from each group were examined with a Scanning Electron Microscope (SEM) to determine the signs of cyclic fatigue. Results: One-way analysis of variance (ANOVA) was applied to the normally distributed groups (p<0,05). Since there was a significant statistical difference of file’s cyclic fatigue resistance (p=0,001) between the groups, Tukey’s honestly significant difference (HSD) post-hoc pairwise comparison test were used for determine to between which groups. While there were statistically significant differences between Group 1 and Group 2 (p=0,001), and between Group 1 and Group 3 (p=0,001), there was no significant difference between Group 2 and Group 3 (p=0,376). Group 1 displayed the highest resistance to cyclic fatigue. There were no statistically significant differences between the lengths of the fractured files within the three groups according to the one-way analysis of variance (p=0,847). Conclusion: In our study, it was observed that the reciprocal angles of CCW 150°–CW 30°, which were also suggested by the file manufacturer firms, had the highest fracture resistance against cyclic fatigue.   How to cite this article: Akay A, Adıgüzel Ö, Erkan Akay S, Kaya S. Comparison of cyclic fatigue of a reciprocating file system at different angles of rotation. Int Dent Res 2021;11(Suppl.1):67-72. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.11   Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.  


2007 ◽  
Vol 77 (4) ◽  
pp. 701-706 ◽  
Author(s):  
Rodney G. Northrup ◽  
David W. Berzins ◽  
Thomas Gerard Bradley ◽  
William Schuckit

Abstract Objective: To evaluate and compare the shear bond strengths of two adhesives using two types of brackets: a conventional and a self-ligating bracket system. Materials and Methods: Sixty extracted human premolars were collected. The premolars were randomly divided into three groups of 20 teeth. All three groups were direct bonded. Groups 1 and 2 used light-cured adhesive and primer (Transbond XT) with a conventional (Orthos) and a self-ligating bracket (Damon 2), respectively. Group 3 used a light-cured primer (Orthosolo) and a light-cured adhesive (Blūgloo) with a self-ligating bracket (Damon 2). The specimens were stored in distilled water at 37°C for 40 ± 2 hours, after which they were debonded and inspected for Adhesive Remnant Index (ARI) scoring. Results: The mean shear bond strength was 15.2 MPa for group 1, 23.2 MPa for group 2, and 24.8 MPa for group 3. A one-way analysis of variance and post hoc Tukey test showed significant differences in bond strength (P &lt; .001) between group 1 and groups 2 and 3 but no significant difference (P &gt; .05) between groups 2 and 3. A Weibull analysis demonstrated that all three groups provided sufficient bond strength with over 90% survival rate at normal masticatory and orthodontic force levels. A Kruskal-Wallis test showed no significant difference (P &gt; .05) in ARI scores among all three groups. Conclusions: All three groups demonstrated clinically acceptable bond strength. The Damon 2 self-ligating bracket exhibited satisfactory in vitro bond strength with both adhesive systems used.


Molecules ◽  
2019 ◽  
Vol 24 (15) ◽  
pp. 2681 ◽  
Author(s):  
Camilla Maria Cova ◽  
Luisa Boffa ◽  
Marco Pistocchi ◽  
Silver Giorgini ◽  
Rafael Luque ◽  
...  

Vegetal leftovers from the agro–food industry represent a huge source of primary and secondary metabolites, vitamin, mineral salts and soluble as well as insoluble fibers. Economic reports on the growth in the polyphenol market have driven us to focus our investigation on chicory (Chicorium intybus L.), which is one of the most popular horticultural plants in the world and a rich source of phenolic compounds. Ultrasound-assisted extraction (UAE), microwave-assisted extraction (MAE) and their simultaneous combination, using either ethanol/water or water alone (also sub-critical), have been investigated with the aim of designing a green and efficient extraction process. Higher total-polyphenol yields as well as dramatic reductions in extraction times and solvent consumption have been obtained under these conditions. ANOVA test for analyses of variance followed by the Tukey honestly significant difference (HSD) post-hoc test of multiple comparisons was used in the statistical analysis. MAE experiments performed with sub-critical water, and MW/US experiments with an ethanol solution have shown polyphenol recovery values of up to ~3 g of gallic acid equivalents (GAE) per kg of fresh material in only 15 min, while conventional extraction required 240 min to obtain the same result.


2012 ◽  
Vol 147 (5) ◽  
pp. 848-854 ◽  
Author(s):  
Jean Anderson Eloy ◽  
Shawn Li ◽  
Khushabu Kasabwala ◽  
Nitin Agarwal ◽  
David R. Hansberry ◽  
...  

Objective Various otolaryngology associations provide Internet-based patient education material (IPEM) to the general public. However, this information may be written above the fourth- to sixth-grade reading level recommended by the American Medical Association (AMA) and National Institutes of Health (NIH). The purpose of this study was to assess the readability of otolaryngology-related IPEMs on various otolaryngology association websites and to determine whether they are above the recommended reading level for patient education materials. Study Design and Setting Analysis of patient education materials from 9 major otolaryngology association websites. Methods The readability of 262 otolaryngology-related IPEMs was assessed with 8 numerical and 2 graphical readability tools. Averages were evaluated against national recommendations and between each source using analysis of variance (ANOVA) with post hoc Tukey’s honestly significant difference (HSD) analysis. Mean readability scores for each otolaryngology association website were compared. Results Mean website readability scores using Flesch Reading Ease test, Flesch-Kincaid Grade Level, Coleman-Liau Index, SMOG grading, Gunning Fog Index, New Dale-Chall Readability Formula, FORCAST Formula, New Fog Count Test, Raygor Readability Estimate, and the Fry Readability Graph ranged from 20.0 to 57.8, 9.7 to 17.1, 10.7 to 15.9, 11.6 to 18.2, 10.9 to 15.0, 8.6 to 16.0, 10.4 to 12.1, 8.5 to 11.8, 10.5 to 17.0, and 10.0 to 17.0, respectively. ANOVA results indicate a significant difference ( P < .05) between the websites for each individual assessment. Conclusion The IPEMs found on all otolaryngology association websites exceed the recommended fourth- to sixth-grade reading level.


2018 ◽  
Vol 5 (2) ◽  
pp. 8-11
Author(s):  
Rupan Tripathi ◽  
Vanita Gautam ◽  
V. K. Pahwa ◽  
Vikas Agrhari ◽  
Manu Batra ◽  
...  

INTRODUCTION: The use of intracanal medicaments help in elimination of bacteria that remain even after cleaning and shaping. This study isdone to compare the antimicrobial efficacy of2% chlorhexidine gel and calcium hydroxide as an intracanal medicament against E.faecalis.MATERIAL  & METHODS: Sixty extracted single-rooted human teeth were prepared with standard method. After contaminating the canals with E. Faecalis and incubated for seven days, the samples were divided into four groups (n=15). Normal saline was used as control group. The teeth in each group were treated with normal saline, calcium hydroxide and 2% chlorhexidine gel. Microbial samples were obtained from the dentinal shavings of root and colony forming units (CFU) of E.faecalis were recorded after 24hrs, 72hrs and 7 days.RESULTS: To determine the significance of the differences between the different groups, ANOVA(Analysis of variance) and Tukeys Honestly significant Difference (HSD) Post hoc test were performed. Mean CFU of calcium hydroxide group and 2% chlorhexidine group was statistically significantly different from CFU of all other groups (p<0.01).CONCLUSION: Mean CFU of calcium hydroxide was found to increase at 24 hrs and decreases at 72 hrs and 7 days.The antimicrobial efficacy 2% chlorhexidine gel was better than calcium hydroxide paste.Journal of Universal College of Medical Sciences (2017)Vol.05 No.02 Issue 16, Page: 8-11


2013 ◽  
Vol 471 ◽  
pp. 151-155
Author(s):  
A.R. Yusoff ◽  
Baba M. Deros ◽  
D.D.I Daruis

The purpose of this paper is to discuss the vibration transmissibility from a cars body to pedal-pad, and the lower extremity, especially on the foot. The vibration transmissibility will occur when the foot interacts with the pedal-pad once the vehicle engine is turned on. The vibrations transmissibility will cause drivers discomfort, especially on the lower extremity due to fatigue and tiredness of the foot. The relationship between vibration transmissibility with the different sizes pedal-pad to the foot, and whether it can contribute to the foot discomfort during handling and controlling pedal-pad while driving is investigated. The variables are the different sizes of pedal-pad. Data was recorded from foot on three different sizes of pedal-pads. The data was measured in root mean square (r.m.s) unit, of the frequency weighted acceleration (m/s2) for every minute. The result for the foot-transmitted-vibration shows the ratio value of medium sized pedal-pad is greater than 1; compared to small sized and large sized pedal-pads which is less than 1. Analysis of One-way Anova shows that the mean of different sizes of pedal-pad is significant. Tukeyspost-hocwith HSD (Honestly Significant Difference) test on the foot transmitted-vibration proves that the means for medium size pedal-pad is the highest compared with the small and large size pedal-pads.


Blood ◽  
2009 ◽  
Vol 114 (22) ◽  
pp. 1868-1868 ◽  
Author(s):  
Michele Cavo ◽  
Sara Bringhen ◽  
Nicoletta Testoni ◽  
Paola Omedè ◽  
Giulia Marzocchi ◽  
...  

Abstract Abstract 1868 Poster Board I-893 Introduction Bortezomib was initially reported to overcome the poor prognosis related to the presence of del(13q) in patients with advanced refractory/relapsed multiple myeloma (MM). However, more recent evaluations of genomic aberrations in MM provided demonstration that only t(4;14) and del(17p) retained prognostic value for both EFS and OS, thus identifying a subgroup of patients at high risk of progression or death. The combination of bortezomib with melphalan and prednisone, actually licensed as first-line therapy for MM patients who are not eligible for autologous stem-cell transplantation (ASCT), showed comparable activities in terms of time to progression and OS among patients with or without high-risk cytogenetic profiles. However, the number of high-risk patients analyzed was very limited, due to the low frequency of these genomic abnormalities. To more carefully assess the role of bortezomib in patients with high-risk cytogenetics [(e.g. carrying t(4;14) and/or del(17p)], we performed a post-hoc analysis of two phase 3 studies of first-line bortezomib-based regimens for the treatment of a large series of MM patients. Both studies are actually conducted by the Italian Myeloma Network GIMEMA. Patients and methods The activity of three different bortezomib-based regimens in terms of achievement of best high-quality response (immunofixation negative CR) and PFS was analyzed. Regimens evaluated were bortezomib-thalidomide-dexamethasone (VTD), bortezomib-melphalan-prednisone (VMP) and bortezomib-melphalan-prednisone-thalidomide (VMPT). VTD was followed by ASCT. Treatment details are as follows: VTD (Bortezomib, 1.3 mg/m2 twice-weekly, every 21/d cycle; Thalidomide, 200 mg/d; Dexamethasone, 320 mg/cycle); VMP (Bortezomib 1.3 mg/m2 on d 1, 8, 15 and 22, every 35/d cycle; Melphalan, 9 mg/m2 on d 1 through 4, every cycle; Prednisone, 60 mg/m2 on d 1–4 of each cycle); VMPT (VMP, as previously described; Thalidomide, 50 mg/d). A total of 566 patients for whom results of interphase FISH analysis at diagnosis were available for the presence or absence of del(13q) and/or t(4;14) and/or del(17p), were included in the present study. Three cytogenetic subgroups of patients were identified, including those without genomic abnormalities (group 1; n=257), those with del(13q) alone (group 2; n=162) and those who carried t(4;14) and/or del(17p) with or without del(13q) (group 3; n=147). For the purpose of the present analysis, clinical outcomes (e.g. CR rate and PFS) of patients treated with the 3 bortezomib-based regimens were compared according to the presence or absence of different genomic aberrations (e.g. group 1 vs 3 and group 2 vs 3). Results Overall, the frequency of patients belonging to group 1 (no abnormalities), group 2 [del(13q) alone] and group 3 [t(4;14)±del(17p)] was 45%, 29% and 26%, respectively. Comparable rates of genomic aberrations were detected in patients treated with the 3 bortezomib-based regimens [no genetic abnormalities: 46% in VTD vs 48% in VMP vs 42% in VMPT; del(13q) alone: 30% in VTD vs 28% in VMP vs 28% in VMPT; t(4;14)±del(17p): 24% in VTD vs 24% in VMP vs 30% in VMPT]. No statistically significant difference in terms of CR rate was detected by comparing patients in group 3 with those in group 1 (38% vs 31.5%, respectively; P=0.1) and in group 2 (48%, P=0.07). The 2-year projected PFS was 63% for patients with high-risk cytogenetics vs 71% for those with del(13q) alone (P=0.1) vs 75% for patients without cytogenetic abnormalities (P=0.01). The finding that in the high-risk cytogenetic subgroup the VMP regimen comprising once-weekly standard-dose bortezomib effected the lowest rate of CR and PFS may explain, at least in part, the longer PFS for the subgroup without cytogenetic abnormalities. Indeed, after exclusion from the analysis of the VMP regimen, no statistically significant difference in terms of PFS was seen among VTD- and VMPT-treated patients according to the presence of high-risk cytogenetics or the absence of genomic abnormalities (P=0.09). Conclusions These results, based on a post-hoc analysis of patients with different age and treatment exposure, should be cautiously interpreted, although consistencies exist between them and previous reports on the activity of bortezomib in MM with high-risk cytogenetic abnormalities. Further analyses of large series of homogeneously treated patients are needed before firm conclusions can be drawn about the ability of bortezomib-based regimens to overcome the adverse prognosis related to t(4;14) and/or del(17p). Disclosures: Cavo: Ortho Biotech, Janssen-Cilag: Honoraria, Research Funding, Speakers Bureau; Millennium Pharmaceuticals: Honoraria; Novartis: Honoraria; Celgene: Honoraria. Boccadoro:Ortho Biotech, Janssen-Cilag: Honoraria, Speakers Bureau. Palumbo:Ortho Biotech, Janssen-Cilag: Honoraria; Celgene: Honoraria, Speakers Bureau.


Sign in / Sign up

Export Citation Format

Share Document