scholarly journals TRNSYS simulation of desiccant integrated hybrid cooling and dehumidification system

2021 ◽  
Vol 4 (3) ◽  

The traditional air conditioners suffer from performance degradation especially in humid conditions. This is due to fact that the excess moisture level in ventilation air considerably increases latent cooling load of the space to be conditioned. The use of desiccant integrated sensible cooling system can alleviate this problem by controlling the temperature and humidity separately. It also reduces energy consumption for obtaining desired thermal comfort. In the present study, TRNSYS simulation studio project has been developed to perform the simulations of the desiccant dehumidifier coupled HVAC system for different configurations in summer cooling season. Measurements are also carried out to observe the influence of operating parameters on system performance. The obtained results show that the proposed system has ensured a substantial reduction in process air humidity at dehumidifier exit while maintaining the conditioned room comfort.

1996 ◽  
Vol 118 (1) ◽  
pp. 16-21 ◽  
Author(s):  
S. M. Aceves

This paper shows an analysis of the applicability of an adsorption system for electric vehicle (EV) air conditioning. Adsorption systems are designed and optimized to provide the required cooling for four combinations of vehicle characteristics and driving cycles. The resulting adsorption systems are compared with vapor compression air conditioners that can satisfy the cooling load. The objective function is the overall system weight, which includes the cooling system weight and the weight of the battery necessary to provide energy for air conditioner operation. The system with the minimum overall weight is considered to be the best. The results show the optimum values of all the variables, as well as temperatures and amounts adsorbed, for the adsorption and desorption processes. The results indicate that, for the conditions analyzed in this paper, vapor compression air conditioners are superior to adsorption systems, not only because they are lighter, but also because they have a higher COP and are more compact.


Author(s):  
Junaidah Jailani ◽  
◽  
Norsyalifa Mohamad ◽  
Muhammad Amirul Omar ◽  
Hauashdh Ali ◽  
...  

According to the National Energy Balance report released by the Energy Commission of Malaysia in 2016, the residential sector uses 21.6% of the total energy in Malaysia. Residents waste energy through inefficient energy consumption and a lack of awareness. Building occupants are considered the main factor that influences energy consumption in buildings, and to change energy consumption on an overall scale, it is crucial to change individual behaviour. Therefore, this study focused on analysing the energy consumption pattern and the behaviour of consumers towards energy consumption in their homes in the residential area of Batu Pahat, Johor. A self-administrated questionnaire approach was employed in this study. The findings of this study showed that the excessive use of air conditioners was a significant factor in the increasing electricity bills of homeowners as well as the inefficient use of electrical appliances. Also, this study determined the effect of awareness on consumer behaviour. This study recommends ways to help minimise energy consumption in the residential area.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3298
Author(s):  
Gianpiero Colangelo ◽  
Brenda Raho ◽  
Marco Milanese ◽  
Arturo de Risi

Nanofluids have great potential to improve the heat transfer properties of liquids, as demonstrated by recent studies. This paper presents a novel idea of utilizing nanofluid. It analyzes the performance of a HVAC (Heating Ventilation Air Conditioning) system using a high-performance heat transfer fluid (water-glycol nanofluid with nanoparticles of Al2O3), in the university campus of Lecce, Italy. The work describes the dynamic model of the building and its heating and cooling system, realized through the simulation software TRNSYS 17. The use of heat transfer fluid inseminated by nanoparticles in a real HVAC system is an innovative application that is difficult to find in the scientific literature so far. This work focuses on comparing the efficiency of the system working with a traditional water-glycol mixture with the same system that uses Al2O3-nanofluid. The results obtained by means of the dynamic simulations have confirmed what theoretically assumed, indicating the working conditions of the HVAC system that lead to lower operating costs and higher COP and EER, guaranteeing the optimal conditions of thermo-hygrometric comfort inside the building. Finally, the results showed that the use of a nanofluid based on water-glycol mixture and alumina increases the efficiency about 10% and at the same time reduces the electrical energy consumption of the HVAC system.


2021 ◽  
Vol 13 (2) ◽  
pp. 983
Author(s):  
Mustapha Mukhtar ◽  
Bismark Ameyaw ◽  
Nasser Yimen ◽  
Quixin Zhang ◽  
Olusola Bamisile ◽  
...  

The world has not been able to achieve minimum greenhouse gas emissions in buildings’ energy consumptions because the energy and emissions optimization techniques have not been fully utilized. Thermal comfort is one of the most important issues for both residential and commercial buildings. Out of the 40% of global energy consumed by buildings, a large fraction is used to maintain their thermal comfort. In this study, a comprehensive review of the recent advancements in building energy conservation and efficiency application is presented based on existing high-quality research papers. Additionally, the retrofit of the heating/cooling and hot water system for an entire community in Cyprus is presented. This study aims to analyze the technical and environmental benefits of replacing existing electric heaters for hot water with heat pump water heating systems and the use of heat pump air conditioners for thermal comfort in place of the existing ordinary air conditioners for space heating and cooling. One administrative building, 86 apartments (including residential and commercial) buildings, and a restaurant building is retrofitted, and the feasibility of the project is determined based on three economic indicators, namely; simple payback period (SPP), internal rate of return (IRR), and net present value (NPV). The electrical energy required by the hot water systems and the heating/cooling system is reduced by 263,564 kWh/yr and 144,825 kWh/yr, respectively. Additionally, the retrofit project will reduce Cyprus’ CO2 emission by 121,592.8 kg yearly. The SPP, IRR, and NPV for the project show that the retrofit is economically feasible.


Author(s):  
Mehdi Mehrpooya ◽  
Parimah Bahramian ◽  
Fathollah Pourfayaz ◽  
Hadi Katooli ◽  
Mostafa Delpisheh

Abstract The production of liquefied natural gas (LNG) is a high energy-consuming process. The study of ways to reduce energy consumption and consequently to reduce operational costs is imperative. Toward this purpose, this study proposes a hybrid system adopting a mixed refrigerant for the liquefaction of natural gas that is precooled with an ammonia/water absorption refrigeration (AR) cycle utilizing the exhaust heat of a molten carbonate fuel cell, 700°C and 2.74 bar, coupled with a gas turbine and a bottoming Brayton super-critical carbon dioxide cycle. The inauguration of the ammonia/water AR cycle to the LNG process increases the cooling load of the cycle by 10%, providing a 28.3-MW cooling load duty while having a 0.45 coefficient of performance. Employing the hybrid system reduces energy consumption, attaining 85% overall thermal efficiency, 53% electrical efficiency and 35% fuel cell efficiency. The hybrid system produces 6300 kg.mol.h−1 of LNG and 146.55 MW of electrical power. Thereafter, exergy and sensitivity analyses are implemented and, accordingly, the fuel cell had an 83% share of the exergy destruction and the whole system obtained a 95% exergy efficiency.


Author(s):  
Uschas Chowdhury ◽  
Manasa Sahini ◽  
Ashwin Siddarth ◽  
Dereje Agonafer ◽  
Steve Branton

Modern day data centers are operated at high power for increased power density, maintenance, and cooling which covers almost 2 percent (70 billion kilowatt-hours) of the total energy consumption in the US. IT components and cooling system occupy the major portion of this energy consumption. Although data centers are designed to perform efficiently, cooling the high-density components is still a challenge. So, alternative methods to improve the cooling efficiency has become the drive to reduce the cooling cost. As liquid cooling is more efficient for high specific heat capacity, density, and thermal conductivity, hybrid cooling can offer the advantage of liquid cooling of high heat generating components in the traditional air-cooled servers. In this experiment, a 1U server is equipped with cold plate to cool the CPUs while the rest of the components are cooled by fans. In this study, predictive fan and pump failure analysis are performed which also helps to explore the options for redundancy and to reduce the cooling cost by improving cooling efficiency. Redundancy requires the knowledge of planned and unplanned system failures. As the main heat generating components are cooled by liquid, warm water cooling can be employed to observe the effects of raised inlet conditions in a hybrid cooled server with failure scenarios. The ASHRAE guidance class W4 for liquid cooling is chosen for our experiment to operate in a range from 25°C – 45°C. The experiments are conducted separately for the pump and fan failure scenarios. Computational load of idle, 10%, 30%, 50%, 70% and 98% are applied while powering only one pump and the miniature dry cooler fans are controlled externally to maintain constant inlet temperature of the coolant. As the rest of components such as DIMMs & PCH are cooled by air, maximum utilization for memory is applied while reducing the number fans in each case for fan failure scenario. The components temperatures and power consumption are recorded in each case for performance analysis.


2014 ◽  
Vol 525 ◽  
pp. 408-411
Author(s):  
Min Seon Jang ◽  
Gyeong Seok Choi ◽  
Jae Sik Kang ◽  
Yumin Kim

Window film is generally attached the glazing in buildings to improve the thermal performance of the window system by addressing a range of problems such as indoor temperature rise, indoor temperature imbalance, degraded heating and cooling load due to excessive influx of solar radiation. To evaluate the performance of window films, window films are attached to 3mm or 6mm clear glass. However, window films are generally used on existing window systems for reducing the annual energy consumption. Therefore it is necessary to evaluate the performance of window films depending on the performance of glazing such as clear double glazing or low-e double glazing. Thus the purpose of this study is to analyze the performance of window systems when window film is attached. As a result, in the case of applying window films for reducing the SHGC of buildings, it is necessary to select window films suitable for the configuration and performance of the glazing to be installed, considering the SHGC of the entire glazing system.


2011 ◽  
Vol 396-398 ◽  
pp. 516-519
Author(s):  
Yi Zhang ◽  
Dong Ming Guo ◽  
Li Meng

With the deep mining in coal mine, heat damage is one of the technical issues need to be solved. HEMS cooling system in Sanhejian Coal Mine is a process system for high-temperature heat damage controlling in deep coal mine, in which cool energy extracted to reduce work face’s ambient temperature to achieve heat damage controlling. Part of the cool energy is from the level circulating of cooling water in -700 level main raodway, the other is from the mine water. We analyze the energy consumption of every subsystem during operation of the HEMS system, which could provide a theoretical basis and technical guidance on more efficiently running of cooling system deep in the future.


Author(s):  
Zicheng Cai ◽  
Asad A. Ul Haq ◽  
Michael E. Cholette ◽  
Dragan Djurdjanovic

This paper presents evaluation of the energy consumption and tracking performance associated with the use of a recently introduced dual-mode model predictive controller (DMMPC) for control of a heating, ventilation, and air conditioning (HVAC) system. The study was conducted using detailed simulations of an HVAC system, which included a multizone air loop, a water loop, and a chiller. Energy consumption and tracking performance are computed from the simulations and evaluated in the presence of different types and magnitudes of noise and disturbances. Performance of the DMMPC is compared with a baseline proportional-integral-derivative (PID) control structure commonly used for HVAC system control, and this comparison showed clear and consistent superiority of the DMMPC.