scholarly journals Performance Analysis of Air and Oxy-Fuel Laminar Combustion in a Porous Plate Reactor

Energies ◽  
2019 ◽  
Vol 12 (9) ◽  
pp. 1706
Author(s):  
Furqan Tahir ◽  
Haider Ali ◽  
Ahmer A.B. Baloch ◽  
Yasir Jamil

Greenhouse gas emissions from the combustion of fossil fuels pose a serious threat to global warming. Mitigation measures to counter the exponential growth and harmful impact of these gases on the environment require techniques for the reduction and capturing of carbon. Oxy-fuel combustion is one such effective method, which is used for the carbon capture. In the present work, a numerical study was carried out to analyze characteristics of oxy-fuel combustion inside a porous plate reactor. The advantage of incorporating porous plates is to control local oxy-fuel ratio and to avoid hot spots inside the reactor. A modified two-steps reaction kinetics model was incorporated in the simulation for modeling of methane air-combustion and oxy-fuel combustion. Simulations were performed for different oxidizer ratios, mass flow rates, and reactor heights. Results showed that that oxy-combustion with an oxidizer ratio (OR) of 0.243 could have the same adiabatic flame temperature as that of air-combustion. It was found that not only does OR need to be changed, but also flow field or reactor dimensions should be changed to achieve similar combustion characteristics as that of air-combustion. Fifty percent higher mass flow rates or 40% reduction in reactor height may achieve comparable outlet temperature to air-combustion. It was concluded that not only does the oxidizer ratio of oxy-combustion need to be changed, but the velocity field is also required to be matched with air-combustion to attain similar outlet temperature.

2020 ◽  
Vol 10 (4) ◽  
pp. 1298
Author(s):  
Shan Jin ◽  
Qingyang Meng ◽  
Zhiming Li ◽  
Ningbo Zhao ◽  
Hongtao Zheng ◽  
...  

The mixing process of fuel and oxidizer is a very critical factor affecting the real operating performance of non-premixed rotating detonation combustor. In this paper, a two-dimensional numerical study is carried out to investigate the flow and mixing characteristics of CH4/air in combustor with different injection structures. On this basis, the effect of CH4/air mixing on the critical ignition energy for forming detonation is theoretically analyzed in detail. The numerical results indicate that injection strategies of CH4 and air can obviously affect the flow filed characteristic, pressure loss, mixing uniformity and local equivalence ratio in combustor, which further affect the critical ignition energy for forming detonation. In the study for three different mass flow rates (the mass flow rates of air are 12.01 kg/s,8.58 kg/s and 1.72 kg/s, respectively), when air is radially injected into combustor (fuel/air are injected perpendicular to each other), although the mixing quality of CH4 and air is improved, the total pressure loss is also increased. In addition, the comparative analysis also shows that the increase of mass flow rate of CH4/air can decrease the difference of the critical ignition energy for forming detonation at a constant total equivalence ratio. The ignition energy decreases with the decrease of the total flow rate and then increases gradually.


1988 ◽  
Vol 110 (2) ◽  
pp. 90-97 ◽  
Author(s):  
R. Celentano ◽  
R. Kirchner

An experimental study was conducted on the operation of a “once-through” thermosiphon system. This new type of natural circulation system, unlike the standard thermosiphon system, heats the collector fluid in one pass without any recirculation. An electrically heated manifold was used to simulate the useful solar gain. Power was varied with time in 22 half-hour increments to simulate the actual daily useful solar gain. The time-dependent responses of the system in terms of temperatures and mass flow rates were recorded and plotted. The response time for mass flow and temperature to approach steady state varied directly with the size of the power step. Two experiments were conducted; one which tracked mass flows and outlet temperatures for variable useful solar gains, and a second which tracked mass flows at constant outlet temperature for variable useful solar gains.


2017 ◽  
Vol 2017 ◽  
pp. 1-14 ◽  
Author(s):  
Seyyed Mahdi Taheri Mousavi ◽  
Fuat Egelioglu

The thermal performances of three slit-glazed solar air heaters (SGSAHs) were investigated experimentally. Three SGSAHs with different bed heights (7 cm, 5 cm, and 3 cm) were fabricated with multiple glass panes used for glazing. The length, width, and thickness of each pane were 154 cm, 6 cm, and 0.4 cm, respectively. Ambient air was continuously withdrawn through the gaps between the glass panes by fans. The experiments were conducted for four different gap distances between the glass panes (0.5 mm, 1 mm, 2 mm, and 3 mm) and the air mass flow rate was varied between 0.014 kg/s and 0.057 kg/s. The effects of air mass flux on the outlet temperature and thermal efficiency were studied. For the SGSAH with bed height of 7 cm and glass pane gap distance of 0.5 mm, the highest efficiency was obtained as 82% at a mass flow rate of 0.057 kg/s and the air temperature difference between the inlet and the outlet (∆T) was maximum (27°C) when the mass flow rate was least. The results demonstrate that for lower mass flow rates and larger gaps, the performance of SGSAH with a bed height of 3 cm was better compared to that of others. However, for higher mass flow rates, the SGSAH with 7 cm bed height performed better.


2008 ◽  
Vol 2008 ◽  
pp. 1-5 ◽  
Author(s):  
David Palko ◽  
Henryk Anglart

A numerical investigation of the heat transfer deterioration (HTD) phenomena is performed using the low-Re k-ωturbulence model. Steady-state Reynolds-averaged Navier-Stokes equations are solved together with equations for the transport of enthalpy and turbulence. Equations are solved for the supercritical water flow at different pressures, using water properties from the standard IAPWS (International Association for the Properties of Water and Steam) tables. All cases are extensively validated against experimental data. The influence of buoyancy on the HTD is demonstrated for different mass flow rates in the heated pipes. Numerical results prove that the RANS low-Re turbulence modeling approach is fully capable of simulating the heat transfer in pipes with the water flow at supercritical pressures. A study of buoyancy influence shows that for the low-mass flow rates of coolant, the influence of buoyancy forces on the heat transfer in heated pipes is significant. For the high flow rates, buoyancy influence could be neglected and there are clearly other mechanisms causing the decrease in heat transfer at high coolant flow rates.


Author(s):  
A. Andreini ◽  
A. Bonini ◽  
G. Caciolli ◽  
B. Facchini ◽  
S. Taddei

Due to the stringent cooling requirements of novel aeroengines combustor liners, a comprehensive understanding of the phenomena concerning the interaction of hot gases with typical coolant jets plays a major role in the design of efficient cooling systems. In this work an aerodynamic analysis of the effusion cooling system of an aero-engine combustor liner was performed; the aim was the definition of a correlation for the discharge coefficient (CD) of the single effusion hole. The data was taken from a set of CFD RANS simulations, in which the behavior of the effusion cooling system was investigated over a wide range of thermo fluid-dynamics conditions. In some of these tests, the influence on the effusion flow of an additional air bleeding port was taken in account, making possible to analyze its effects on effusion holes CD. An in depth analysis of the numerical data set has pointed out the opportunity of an efficient reduction through the ratio of the annulus and the hole Reynolds numbers: the dependence of the discharge coefficients from this parameter is roughly linear. The correlation was included in an in-house one dimensional thermo-fluid network solver and its results were compared with CFD data. An overall good agreement of pressure and mass flow rates distributions was observed. The main source of inaccuracy was observed in the case of relevant air bleed mass flow rates, due to the inherent three-dimensional behavior of the flow close to bleed opening. An additional comparison with experimental data was performed in order to improve the confidence in the accuracy of the correlation: within the validity range of pressure ratio in which the correlation is defined (> 1.02), this comparison pointed out a good reliability in the prediction of discharge coefficients. An approach to model air bleeding was then proposed, with the assessment of its impact on liner wall temperature prediction.


Author(s):  
Yingyuan Liu ◽  
Leqin Wang ◽  
Zuchao Zhu

This work is purposed to study the flow characteristics of rotor pumps including cavitation. First, a simplified two-dimensional numerical model is developed and computing strategies of the numerical analysis for cavitation are set up, including the selection of cavitation model and its parameters. Second, the reliability and accuracy of the two-dimensional numerical model are verified by experimental results. Then, several factors affecting the cavitation are discussed, including the rotational speeds, pressure differences, clearance sizes, and inlet pressures. For different rotational speeds and pressure differences, the mass flow rates with cavitation are a little larger than that without cavitation, but the amplitudes of the mass flow rates with cavitation are much larger than that without cavitation. Meanwhile, the volume fraction of the water vapor increases with the increasing speeds and the decreasing pressure differences. However, compared with the influence of rotational speeds, the influence of the pressure differences on the vapor contents is relatively smaller. Regarding the clearance size, the smaller the clearance size is, the stronger the cavitation will be. Furthermore, the clearance size between two rotors has a larger effect on the cavitation than that between rotor and pump case. For inlet pressure, it has a little effect on the mass flow rates when cavitation is not considered, but it presents a remarkable effect for the model with cavitation. In addition, the peaks of the volume fractions of vapor and the mass flow rates generally offset backward with the decreasing inlet pressures.


2021 ◽  
Vol 9 (1) ◽  
Author(s):  
Tobias Blanke ◽  
Markus Hagenkamp ◽  
Bernd Döring ◽  
Joachim Göttsche ◽  
Vitali Reger ◽  
...  

AbstractPrevious studies optimized the dimensions of coaxial heat exchangers using constant mass flow rates as a boundary condition. They show a thermal optimal circular ring width of nearly zero. Hydraulically optimal is an inner to outer pipe radius ratio of 0.65 for turbulent and 0.68 for laminar flow types. In contrast, in this study, flow conditions in the circular ring are kept constant (a set of fixed Reynolds numbers) during optimization. This approach ensures fixed flow conditions and prevents inappropriately high or low mass flow rates. The optimization is carried out for three objectives: Maximum energy gain, minimum hydraulic effort and eventually optimum net-exergy balance. The optimization changes the inner pipe radius and mass flow rate but not the Reynolds number of the circular ring. The thermal calculations base on Hellström’s borehole resistance and the hydraulic optimization on individually calculated linear loss of head coefficients. Increasing the inner pipe radius results in decreased hydraulic losses in the inner pipe but increased losses in the circular ring. The net-exergy difference is a key performance indicator and combines thermal and hydraulic calculations. It is the difference between thermal exergy flux and hydraulic effort. The Reynolds number in the circular ring is instead of the mass flow rate constant during all optimizations. The result from a thermal perspective is an optimal width of the circular ring of nearly zero. The hydraulically optimal inner pipe radius is 54% of the outer pipe radius for laminar flow and 60% for turbulent flow scenarios. Net-exergetic optimization shows a predominant influence of hydraulic losses, especially for small temperature gains. The exact result depends on the earth’s thermal properties and the flow type. Conclusively, coaxial geothermal probes’ design should focus on the hydraulic optimum and take the thermal optimum as a secondary criterion due to the dominating hydraulics.


Sign in / Sign up

Export Citation Format

Share Document