scholarly journals Efficacy of Three Commercial Disinfectants in Reducing Microbial Surfaces’ Contaminations of Pharmaceuticals Hospital Facilities

Author(s):  
Giuseppina Di Martino ◽  
Salvatore Pasqua ◽  
Bruno Douradinha ◽  
Francesco Monaco ◽  
Chiara Di Bartolo ◽  
...  

To evaluate and validate the efficacy of disinfectants used in our cleaning procedure, in order to reduce pharmaceutical hospital surfaces’ contaminations, we tested the action of three commercial disinfectants on small representative samples of the surfaces present in our hospital cleanrooms. These samples (or coupons) were contaminated with selected microorganisms for the validation of the disinfectants. The coupons were sampled before and after disinfection and the microbial load was assessed to calculate the Log10 reduction index. Subsequently, we developed and validated a disinfection procedure on real surfaces inside the cleanrooms intentionally contaminated with microorganisms, using approximately 107–108 total colony forming units per coupon. Our results showed a bactericidal, fungicidal, and sporicidal efficacy coherent to the acceptance criteria suggested by United States Pharmacopeia 35 <1072>. The correct implementation of our cleaning and disinfection procedure, respecting stipulated concentrations and contact times, led to a reduction of at least 6 Log10 for all microorganisms used. The proposed disinfection procedure reduced the pharmaceutical hospital surfaces’ contaminations, limited the propagation of microorganisms in points adjacent to the disinfected area, and ensured high disinfection and safety levels for operators, patients, and treated surfaces.

2017 ◽  
Vol 70 (6) ◽  
pp. 1176-1183 ◽  
Author(s):  
Oleci Pereira Frota ◽  
Adriano Menis Ferreira ◽  
Odanir Garcia Guerra ◽  
Marcelo Alessandro Rigotti ◽  
Denise de Andrade ◽  
...  

ABSTRACT Objective: to assess the correlation among the ATP-bioluminescence assay, visual inspection and microbiological culture in monitoring the efficiency of cleaning and disinfection (C&D) of high-touch clinical surfaces (HTCS) in a walk-in emergency care unit. Method: a prospective and comparative study was carried out from March to June 2015, in which five HTCS were sampled before and after C&D by means of the three methods. The HTCS were considered dirty when dust, waste, humidity and stains were detected in visual inspection; when ≥2.5 colony forming units per cm2 were found in culture; when ≥5 relative light units per cm2 were found at the ATP-bioluminescence assay. Results: 720 analyses were performed, 240 per method. The overall rates of clean surfaces per visual inspection, culture and ATP-bioluminescence assay were 8.3%, 20.8% and 44.2% before C&D, and 92.5%, 50% and 84.2% after C&D, respectively (p<0.001). There were only occasional statistically significant relationships between methods. Conclusion: the methods did not present a good correlation, neither quantitative nor qualitatively.


Author(s):  
B Douglas Ford ◽  
Keith Sopha

Background: Microbes endemic to student desks can survive for long periods and infect students. The effectiveness of conventional cleaning and disinfection practices and electrostatic disinfectant spraying were examined. Methods: Six K-12 schools in Southeastern Ontario participated in the study. The viable microbial loads on 100 student desks were assessed via Replicate Organism Detection and Counting (RODAC) plates before and after cleaning and disinfection procedures. Results: The adjunctive effect of electrostatic disinfectant spraying was tested on 36 desks. Mean pretest colony-forming units (CFUs) per desk were 126.8 (SD 95.7), after conventional cleaning and disinfection mean CFUs were 73.4 (SD 93.0) (t = 4.0, P = 0.0003), and subsequent electrostatic disinfectant spraying further reduced mean CFUs to 54.2 (SD 85.0) (t = 2.6, P = 0.02). The independent effect of electrostatic disinfectant spraying without an intervening conventional cleaning step was tested on 64 desks. Mean pretest CFUs were 106.4 (SD 94.5) and after electrostatic disinfectant spraying mean CFUs decreased to 62.9 (SD 87.1) (t = 3.3, P = 0.001). Conclusions: Conventional and electrostatic disinfection methods were both effective in increasing the hygienic state of student desks. Electrostatic disinfection spraying improved hygienic state when conducted after conventional cleaning and disinfection and when used independently.


1985 ◽  
Vol 53 (01) ◽  
pp. 116-117 ◽  
Author(s):  
R E Merton ◽  
A D Curtis ◽  
D P Thomas

SummaryHeparin samples from five manufacturers were assayed by the revised British Pharmacopoeia (BP) heparin assay and the results compared with those obtained using the activated partial thromboplastin time (APTT) assay. The United States Pharmacopeia (USP) reference heparin preparation and the 4th International Standard (IS) for heparin were also assayed by the two methods relative to the 3rd IS. The results obtained by the revised BP assay were in close agreement with those obtained by the APTT assay for all the heparins that were tested. The assays revealed that there is at least a 10% discrepancy between the International Unit for heparin and the USP unit.


2020 ◽  
Vol 41 (S1) ◽  
pp. s519-s519
Author(s):  
Tami Inman BSN ◽  
David Chansolme

Background: The scientific literature increasingly indicates the need for the development of continuous disinfection to address the persistent contamination and recontamination that occurs in the patient rooms despite routine cleaning and disinfection. Methods: To determine a baseline microbial burden level on patient room surfaces in the intensive care unit (ICU) of a large urban hospital, 50 locations were swabbed for total colony-forming units (CFU) and the prevalence of methicillin-resistant Staphylococcus aureus (MRSA). Once the baseline in ICU patient rooms was established, 5 novel decontamination devices were installed in the HVAC ducts near these patient rooms. The devices provide a continuous low-level application of oxidizing molecules, predominately hydrogen peroxide. These molecules exit the duct and circulate in the patient room through normal convection, landing on all surfaces. After activation, environmental sampling was conducted every 4 weeks for 4 months. The effect from continuous low levels of oxidizing molecules on the intrinsic microbial burden and the prevalence of MRSA were analyzed. In addition to external laboratory reports, the facility tracked healthcare-associated infections (HAIs) in the unit. HAI data were averaged by month and were compared to the preactivation average in the same unit. Results: The preactivation average microbial burden found on the 50 locations were 179,000 CFU per 100 in2. The prevalence of MRSA was 71% with an average of 81 CFU per 100 in2. After activation of the devices, levels of microbial burden, prevalence of MRSA, and average monthly HAI rates were all significantly lower on average: 95% reduction in average microbial burden (8,206 CFU per 100 in2); 81% reduction in the prevalence of MRSA (13% vs 71%); 54% reduction in the average of healthcare-onset HAIs. All data were obtained from the averages of sampling data for 4 weeks during the 4-month trial period. Conclusions: The continuous application of low levels of oxidizing molecules throughout the patient rooms of an ICU demonstrated 3 outcomes: reduced overall surface microbial burden, lowered the incidence of MRSA, and significantly decreased the monthly average HAI rate. Please note, the ICU ran other infection prevention interventions at this time, including standard cleaning, as well as and their standard disinfecting techniques.Funding: This study was supported by the CASPR Group.Disclosures: None


Author(s):  
Surinder Kaur M. S. Pada ◽  
Poh Lishi ◽  
Kim Sim Ng ◽  
Sarathamani Rethenam ◽  
Lilibeth Silagan Alenton ◽  
...  

Abstract Background Computerisation of various processes in hospitals and reliance on electronic devices raises the concern of contamination of these devices from the patient environment. We undertook this study to determine if an attached hand hygiene device that unlocks the screen of a computer on wheels (COW) on usage can be effective in decreasing the microbiological burden on computer keyboards. Methods An electronic hand sanitizer was integrated onto the COW. A prospective cohort study with a crossover design involving 2 control and 2 intervention wards was used. The study end point was the number of colony forming units found on the keyboards. Bacteria were classified into 4 main groups; pathogenic, skin flora, from the environment or those thought to be commensals in healthy individuals. We then used a mixed effects model for the statistical analysis to determine if there were any differences before and after the intervention. Results Thirty-nine keyboards were swabbed at baseline, day 7 and 14, with 234 keyboards cultured, colony forming units (CFUs) counted and organisms isolated. By mixed model analysis, the difference of mean bacteria count between intervention and control for week 1 was 32.74 (− 32.74, CI − 94.29 to 28.75, p = 0.29), for week 2 by 155.86 (− 155.86, CI − 227.45 to − 83.53, p < 0.0001), and after the 2-week period by 157.04 (− 157.04, CI − 231.53 to − 82.67, p < 0.0001). In the sub-analysis, there were significant differences of pathogenic bacteria counts for the Intervention as compared to the Control in contrast with commensal counts. Conclusion A hand hygiene device attached to a COW may be effective in decreasing the microbiological burden on computer keyboards.


2018 ◽  
Vol 29 (5) ◽  
pp. 459-464 ◽  
Author(s):  
Larissa Tais Soligo ◽  
Ediléia Lodi ◽  
Ana Paula Farina ◽  
Matheus Albino Souza ◽  
Cristina de Mattos Pimenta Vidal ◽  
...  

Abstract The aim of this study was to compare the efficacy of grape seed extract (GSE), calcium hypochlorite [Ca(ClO)2], and sodium hypochlorite (NaOCl) irrigant solutions with rotary or reciprocating instrumentation for disinfection of root canals inoculated with Enterococcus faecalis. The mesiobuccal root canals of mandibular molars were prepared and inoculated with Enterococcus faecalis for 21 days. The roots were then randomly divided into the following eight experimental groups (n=11) according to the instrumentation technique and disinfection protocol: ProTaper Next or Reciproc R25 with sodium chloride (control group), 6% NaOCl, 6% Ca(ClO)2, or 50% GSE used for irrigation during instrumentation. The antimicrobial activity was determined on the basis of a reduction in colony-forming units (CFUs) counted on bacterial samples collected before and after root canal instrumentation and expressed as a percentage of reduction. Data were evaluated by two-way ANOVA followed by Tukey HSD post-hoc tests (p<0.05). No significant differences were observed in bacterial reduction between the ProTaper Next and Reciproc R25 systems (p>0.05), regardless of the irrigant solution used. Furthermore, all active solutions (6% NaOCl, 50% GSE, and 6% Ca(ClO)2) showed similar potential to reduce bacterial counts (p>0.05) and were significantly more effective than sodium chloride (control) (p<0.05). The results suggest that the GSE and Ca(ClO)2 have potential clinical application as irrigant solutions in endodontic therapy since they present bactericidal efficacy against Enterococcus faecalis.


2015 ◽  
Vol 24 (4) ◽  
pp. 1061-1070 ◽  
Author(s):  
Marcelo Alessandro Rigotti ◽  
Adriano Menis Ferreira ◽  
Mara Corrêa Lelles Nogueira ◽  
Margarete Teresa Gottardo de Almeida ◽  
Odanir Garcia Guerra ◽  
...  

ABSTRACT The objective of this study was to assess the effectiveness of three surface friction techniques for the removal of organic material. A quantitative, descriptive and exploratory study was developed to evaluate the presence or not of organic material before and after the cleaning and disinfection process of surfaces of bedside tables of patients hospitalized at an Intensive Care Unit. Three friction techniques were executed in the one-way, two-way and centrifugal sense, individually, three times on each table, during alternate weeks. For each patient unit and friction technique, a single table and three sides of cloth were used, moistened with 70% (w/v) alcohol. The organic matter was detected through the presence of adenosine triphosphate by bioluminescence, using 3M(tm) Clean-Trace(tm) ATP Systems. For each technique, 13 samples were collected before and 13 after the cleaning/disinfection process, totaling 78 samples of adenosine triphosphate by bioluminescence. No statistically significant difference was found among the removal techniques of organic matter. This study demonstrated that none of the three surface friction methods was better than the other to remove organic matter. Nevertheless, further research is needed in which other cleaning/disinfection indicators and surfaces are considered.