scholarly journals The Effects of Cold Arm Width and Metal Deposition on the Performance of a U-Beam Electrothermal MEMS Microgripper for Biomedical Applications

Micromachines ◽  
2019 ◽  
Vol 10 (3) ◽  
pp. 167 ◽  
Author(s):  
Marija Cauchi ◽  
Ivan Grech ◽  
Bertram Mallia ◽  
Pierluigi Mollicone ◽  
Nicholas Sammut

Microelectromechanical systems (MEMS) have established themselves within various fields dominated by high-precision micromanipulation, with the most distinguished sectors being the microassembly, micromanufacturing and biomedical ones. This paper presents a horizontal electrothermally actuated ‘hot and cold arm’ microgripper design to be used for the deformability study of human red blood cells (RBCs). In this study, the width and layer composition of the cold arm are varied to investigate the effects of dimensional and material variation of the cold arm on the resulting temperature distribution, and ultimately on the achieved lateral displacement at the microgripper arm tips. The cold arm widths investigated are 14 μ m, 30 μ m, 55 μ m, 70 μ m and 100 μ m. A gold layer with a thin chromium adhesion promoter layer is deposited on the top surface of each of these cold arms to study its effect on the performance of the microgripper. The resultant ten microgripper design variants are fabricated using a commercially available MEMS fabrication technology known as a silicon-on-insulator multi-user MEMS process (SOIMUMPs)™. This process results in an overhanging 25 μ m thick single crystal silicon microgripper structure having a low aspect ratio (width:thickness) value compared to surface micromachined structures where structural thicknesses are of the order of 2 μ m. Finite element analysis was used to numerically model the microgripper structures and coupled electrothermomechanical simulations were implemented in CoventorWare ® . The numerical simulations took into account the temperature dependency of the coefficient of thermal expansion, the thermal conductivity and the electrical conductivity properties in order to achieve more reliable results. The fabricated microgrippers were actuated under atmospheric pressure and the experimental results achieved through optical microscopy studies conformed with those predicted by the numerical models. The gap opening and the temperature rise at the cell gripping zone were also compared for the different microgripper structures in this work, with the aim of identifying an optimal microgripper design for the deformability characterisation of RBCs.

Actuators ◽  
2018 ◽  
Vol 7 (3) ◽  
pp. 38 ◽  
Author(s):  
Marija Cauchi ◽  
Ivan Grech ◽  
Bertram Mallia ◽  
Pierluigi Mollicone ◽  
Nicholas Sammut

The ongoing development of microelectromechanical systems (MEMS) over the past decades has made possible the achievement of high-precision micromanipulation within the micromanufacturing, microassembly and biomedical fields. This paper presents different design variants of a horizontal electrothermally actuated MEMS microgripper that are developed as microsystems to micromanipulate and study the deformability properties of human red blood cells (RBCs). The presented microgripper design variants are all based on the U-shape `hot and cold arm’ actuator configuration, and are fabricated using the commercially available Multi-User MEMS Processes (MUMPs®) that are produced by MEMSCAP, Inc. (Durham, NC, USA) and that include both surface micromachined (PolyMUMPs™) and silicon-on-insulator (SOIMUMPs™) MEMS fabrication technologies. The studied microgripper design variants have the same in-plane geometry, with their main differences arising from the thickness of the fabricated structures, the consequent air gap separation between the structure and the substrate surface, as well as the intrinsic nature of the silicon material used. These factors are all inherent characteristics of the specific fabrication technologies used. PolyMUMPs™ utilises polycrystalline silicon structures that are composed of two free-standing, independently stackable structural layers, enabling the user to achieve structure thicknesses of 1.5 μm, 2 μm and 3.5 μm, respectively, whereas SOIMUMPs™ utilises a 25 μm thick single crystal silicon structure having only one free-standing structural layer. The microgripper design variants are presented and compared in this work to investigate the effect of their differences on the temperature distribution and the achieved end-effector displacement. These design variants were analytically studied, as well as numerically modelled using finite element analysis where coupled electrothermomechanical simulations were carried out in CoventorWare® (Version 10, Coventor, Inc., Cary, NC, USA). Experimental results for the microgrippers’ actuation under atmospheric pressure were obtained via optical microscopy studies for the PolyMUMPs™ structures, and they were found to be conforming with the predictions of the analytical and numerical models. The focus of this work is to identify which one of the studied design variants best optimises the microgripper’s electrothermomechanical performance in terms of a sufficient lateral tip displacement, minimum out-of-plane displacement at the arm tips and good heat transfer to limit the temperature at the cell gripping zone, as required for the deformability study of RBCs.


2013 ◽  
Vol 135 (9) ◽  
Author(s):  
Timothy S. English ◽  
Leslie M. Phinney ◽  
Patrick E. Hopkins ◽  
Justin R. Serrano

Accurate thermal conductivity values are essential for the successful modeling, design, and thermal management of microelectromechanical systems (MEMS) and devices. However, the experimental technique best suited to measure the thermal conductivity of these systems, as well as the thermal conductivity itself, varies with the device materials, fabrication processes, geometry, and operating conditions. In this study, the thermal conductivities of boron doped single-crystal silicon microbridges fabricated using silicon-on-insulator (SOI) wafers are measured over the temperature range from 80 to 350 K. The microbridges are 4.6 mm long, 125 μm tall, and either 50 or 85 μm wide. Measurements on the 85 μm wide microbridges are made using both steady-state electrical resistance thermometry (SSERT) and optical time-domain thermoreflectance (TDTR). A thermal conductivity of 77 Wm−1 K−1 is measured for both microbridge widths at room temperature, where the results of both experimental techniques agree. However, increasing discrepancies between the thermal conductivities measured by each technique are found with decreasing temperatures below 300 K. The reduction in thermal conductivity measured by TDTR is primarily attributed to a ballistic thermal resistance contributed by phonons with mean free paths larger than the TDTR pump beam diameter. Boltzmann transport equation (BTE) modeling under the relaxation time approximation (RTA) is used to investigate the discrepancies and emphasizes the role of different interaction volumes in explaining the underprediction of TDTR measurements.


Author(s):  
N. Lewis ◽  
E. L. Hall ◽  
A. Mogro-Campero ◽  
R. P. Love

The formation of buried oxide structures in single crystal silicon by high-dose oxygen ion implantation has received considerable attention recently for applications in advanced electronic device fabrication. This process is performed in a vacuum, and under the proper implantation conditions results in a silicon-on-insulator (SOI) structure with a top single crystal silicon layer on an amorphous silicon dioxide layer. The top Si layer has the same orientation as the silicon substrate. The quality of the outermost portion of the Si top layer is important in device fabrication since it either can be used directly to build devices, or epitaxial Si may be grown on this layer. Therefore, careful characterization of the results of the ion implantation process is essential.


Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1118
Author(s):  
Yuan Tian ◽  
Yi Liu ◽  
Yang Wang ◽  
Jia Xu ◽  
Xiaomei Yu

In this paper, a polyimide (PI)/Si/SiO2-based piezoresistive microcantilever biosensor was developed to achieve a trace level detection for aflatoxin B1. To take advantage of both the high piezoresistance coefficient of single-crystal silicon and the small spring constant of PI, the flexible piezoresistive microcantilever was designed using the buried oxide (BOX) layer of a silicon-on-insulator (SOI) wafer as a bottom passivation layer, the topmost single-crystal silicon layer as a piezoresistor layer, and a thin PI film as a top passivation layer. To obtain higher sensitivity and output voltage stability, four identical piezoresistors, two of which were located in the substrate and two integrated in the microcantilevers, were composed of a quarter-bridge configuration wheatstone bridge. The fabricated PI/Si/SiO2 microcantilever showed good mechanical properties with a spring constant of 21.31 nN/μm and a deflection sensitivity of 3.54 × 10−7 nm−1. The microcantilever biosensor also showed a stable voltage output in the Phosphate Buffered Saline (PBS) buffer with a fluctuation less than 1 μV @ 3 V. By functionalizing anti-aflatoxin B1 on the sensing piezoresistive microcantilever with a biotin avidin system (BAS), a linear aflatoxin B1 detection concentration resulting from 1 ng/mL to 100 ng/mL was obtained, and the toxic molecule detection also showed good specificity. The experimental results indicate that the PI/Si/SiO2 flexible piezoresistive microcantilever biosensor has excellent abilities in trace-level and specific detections of aflatoxin B1 and other biomolecules.


Author(s):  
И.Е. Тысченко ◽  
И.В. Попов ◽  
Е.В. Спесивцев

AbstractThe anodic oxidation rate of silicon-on-insulator films fabricated by hydrogen transfer is studied as a function of the temperature of subsequent annealing. It is established that the oxidation rate of transferred silicon-on-insulator films is five times lower compared to the oxidation rate of bulk single-crystal silicon samples. The oxidation rate increases, as the annealing temperature is elevated in the range 700–1100°C and as the depth of gradually removed anode-oxidized layers is increased. The results obtained in the study are attributed to an increase in the efficiencies of the anodic current and oxygen–silicon interatomic interaction due to the annealing of defects and due to release of hydrogen from the bound state, respectively. The formation of hydrogen bubbles in the surface region of silicon due to the diffusion of hydrogen, released in the process of the oxidation reaction, towards micropores in the silicon-on-insulator layer is detected.


1999 ◽  
Author(s):  
Todd F. Miller ◽  
David J. Monk ◽  
Gary O’Brien ◽  
William P. Eaton ◽  
James H. Smith

Abstract Surface micromachining is becoming increasingly popular for microelectromechanical systems (MEMS) and a new application for this process technology is pressure sensors. Uncompensated surface micromachined piezoresistive pressure sensors were fabricated by Sandia National Labs (SNL). Motorola packaged and tested the sensors over pressure, temperature and in a typical circuit application for noise characteristics. A brief overview of surface micromachining related to pressure sensors is described in the report along with the packaging and testing techniques used. The electrical data found is presented in a comparative manner between the surface micromachined SNL piezoresistive polysilicon pressure sensor and a bulk micromachined Motorola piezoresistive single crystal silicon pressure sensor.


2020 ◽  
pp. 100107
Author(s):  
L.G. Michaud ◽  
E. Azrak ◽  
C. Castan ◽  
F. Fournel ◽  
F. Rieutord ◽  
...  

Author(s):  
Timothy S. English ◽  
Leslie M. Phinney ◽  
Patrick E. Hopkins ◽  
Justin R. Serrano

Accurate thermal conductivity values are essential to the modeling, design, and thermal management of microelectromechanical systems (MEMS) and devices. However, the experimental technique best suited to measure thermal conductivity, as well as thermal conductivity itself, varies with the device materials, fabrication conditions, geometry, and operating conditions. In this study, the thermal conductivity of boron doped single-crystal silicon-on-insulator (SOI) microbridges is measured over the temperature range from 77 to 350 K. The microbridges are 4.6 mm long, 125 μm tall, and two widths, 50 or 85 μm. Measurements on the 85 μm wide microbridges are made using both steady-state electrical resistance thermometry and optical time-domain thermoreflectance. A thermal conductivity of ∼ 77 W/mK is measured for both microbridge widths at room temperature, where both experimental techniques agree. However, a discrepancy at lower temperatures is attributed to differences in the interaction volumes and in turn, material properties, probed by each technique. This finding is qualitatively explained through Boltzmann transport equation modeling under the relaxation time approximation.


Author(s):  
Wenjun Liu ◽  
Mehdi Asheghi ◽  
K. E. Goodson

Simulations of the temperature field in Silicon-on-Insulator (SOI) and strained-Si transistors can benefit from experimental data and modeling of the thin silicon layer thermal conductivity at high temperatures. This work presents the first experimental data for 20 and 100 nm thick single crystal silicon layers at high temperatures and develops algebraic expressions to account for the reduction in thermal conductivity due to the phonon-boundary scattering for pure and doped silicon layers. The model applies to temperatures range 300–1000 K for silicon layer thicknesses from 10 nm to 1 μm (and even bulk) and agrees well with the experimental data. In addition, the model has an excellent agreement with the predictions of thin film thermal conductivity based on thermal conductivity integral and Boltzmann transport equation, although it is significantly more robust and convenient for integration into device simulators. The experimental data and predictions are required for accurate thermal simulation of the semiconductor devices, nanostructures and in particular the SOI and strained-Si transistors.


1985 ◽  
Vol 53 ◽  
Author(s):  
C. Slawinski ◽  
B.-Y. Mao ◽  
P.-H. Chang ◽  
H.W. Lam ◽  
J.A. Keenan

ABSTRACTBuried nitride silicon-on-insulator (SOI) structures have been fabricated using the technique of nitrogen ion implantation. The crystallinity of the top silicon film was found to be exceptionally good. The minimum channeling yield, Xmin' was better than 3%. This is comparable to the value observed for single crystal silicon. The buried insulator formed during the anneals has been identified as polycrystalline α-Si3 N4 with numerous silicon inclusions. This nitride, however, has been found to remain amorphous in regions at the center of the implant where the nitrogen concentration exceeds the stoichiometric level of Si3N4. Nitrogen donor formation in the top silicon layer has also been observed.


Sign in / Sign up

Export Citation Format

Share Document