scholarly journals Pharmacokinetics and Tissue Distribution of Anwuligan in Rats after Intravenous and Intragastric Administration by Liquid Chromatography-Mass Spectrometry

Molecules ◽  
2019 ◽  
Vol 25 (1) ◽  
pp. 39
Author(s):  
Yang Song ◽  
Yuan Zhang ◽  
Xiao-Yi Duan ◽  
Dong-Wei Cui ◽  
Xin Qiu ◽  
...  

Anwuligan, a natural 2,3-dibenzylbutane lignan from the nutmeg mace of Myristica fragans, has been proved to possess a broad range of pharmacological effects. A rapid, simple, and sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been established and successfully applied to the study of pharmacokinetics and tissue distribution of anwuligan after intravenous or intragastric administration. Sample preparation was carried out through a liquid-liquid extraction method with ethyl acetate as the extraction reagent. Arctigenin was used as the internal standard (IS). A gradient program was employed with a mobile phase consisting of 0.1% formic acid aqueous solution and acetonitrile. The mass spectrometer was operated in a positive ionization mode with multiple reaction monitoring. The transitions for quantification were m/z 329.0→205.0 for anwuligan and m/z 373.0→137.0 for IS, respectively. Calibration curves were linear over the ranges of 0.5–2000 ng/mL for both plasma samples and tissue samples (r > 0.996). The absolute bioavailability is 16.2%, which represented the existing of the obvious first-pass effect. An enterohepatic circulation was found after the intragastric administration. Anwuligan could be distributed rapidly and widely in different tissues and maintained a high concentration in the liver. The developed and validated LC-MS/MS method and the pharmacokinetic study of anwuligan would provide reference for the future investigation of the preclinical safety of anwuligan as a candidate drug.

2019 ◽  
Vol 2019 ◽  
pp. 1-10
Author(s):  
Wei Chen ◽  
Yafei Shi ◽  
Shuya Qi ◽  
Haiyan Zhou ◽  
Chunyu Li ◽  
...  

In the present study, we developed and validated a rapid and simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of lorlatinib in mouse serum and tissue samples, and such a method was successfully applied to investigate the pharmacokinetic study and tissue distribution of lorlatinib after oral administration. Samples were processed with methanol to precipitate protein and extract drugs, and Afatinib-d6 was used as the internal standard (IS). For LC-MS/MS analysis, compounds were separated on a C18 column by gradient elution (0.1% of formic acid and methanol) at 0.5 mL/min in the positive-ion mode with m/z 407.28 [M + H]+ for lorlatinib and m/z 492.10 [M + H]+ for IS. Good linearity was observed within the calibration ranges. Selectivity, accuracy (−6.42% to 8.84%), precision (1.69% to 10.98%), recoveries (91.4% to 115.0%), and matrix effect (84.2% to 110.6%) were all within the acceptable ranges. After oral administration, serum concentration of lorlatinib quickly achieved the maximal concentration (2,705.683 ± 539.779 μg/L) at 0.625 ± 0.231 h. The highest concentration was detected in the liver (3,153.93 ng/100 mg), followed by the stomach (2,159.92 ng/100 mg) and the kidney (548.83 ng/100 mg). In conclusion, a simple and rapid detection method was established and validated for determination of lorlatinib in blood and tissue samples of mouse. The pharmacokinetic study and tissue distribution of lorlatinib were successfully investigated using this method.


2014 ◽  
Vol 60 (2) ◽  
pp. 353-360 ◽  
Author(s):  
Lynn Carr ◽  
Anne-Laure Gagez ◽  
Marie Essig ◽  
François-Ludovic Sauvage ◽  
Pierre Marquet ◽  
...  

Abstract BACKGROUND Blood concentrations of the calcineurin inhibitors (CNIs) cyclosporine and tacrolimus are currently measured to monitor immunosuppression in transplant patients. The measurement of calcineurin (CN) phosphatase activity has been proposed as a complementary pharmacodynamic approach. However, determining CN activity with current methods is not practical. We developed a new method amenable to routine use. METHODS Using liquid chromatography–multiple reaction monitoring mass spectrometry (LC-MRM-MS), we quantified CN activity by measuring the dephosphorylation of a synthetic phosphopeptide substrate. A stable isotope analog of the product peptide served as internal standard, and a novel inhibitor cocktail minimized dephosphorylation by other major serine/threonine phosphatases. The assay was used to determine CN activity in peripheral blood mononuclear cells (PBMCs) isolated from 20 CNI-treated kidney transplant patients and 9 healthy volunteers. RESULTS Linearity was observed from 0.16 to 2.5 μmol/L of product peptide, with accuracy in the 15% tolerance range. Intraassay and interassay recoveries were 100.6 (9.6) and 100 (7.5), respectively. Michaelis–Menten kinetics for purified CN were Km = 10.7 (1.6) μmol/L, Vmax = 2.8 (0.3) μmol/min · mg, and for Jurkat lysate, Km = 182.2 (118.0) μmol/L, Vmax = 0.013 (0.006) μmol/min · mg. PBMC CN activity was successfully measured in a single tube with an inhibitor cocktail. CONCLUSIONS Because LC-MRM-MS is commonly used in routine clinical dosage of drugs, this CN activity assay could be applied, with parallel blood drug concentration monitoring, to a large panel of patients to reevaluate the validity of PBMC CN activity monitoring.


Author(s):  
Narottam Pal ◽  
Avanapu Srinivasa Rao ◽  
Pigilli Ravikumar

<p><strong>Objective</strong>:<strong> </strong>To develop a new method and validate the same for the determination of Febuxostat (FBS) in human plasma by liquid chromatography–mass spectrometry (LCMS).</p><p><strong>Methods</strong>:<strong> </strong>The present method utilized reversed-phase high-performance liquid chromatography with tandem mass spectroscopy. Febuxostat D9 (FBS D9) was used as internal standard (IS). The analyte and internal standard were separated from human plasma by using solid phase extraction method. Zorbax Eclipse XDB, C<sub>8</sub>, 100 mm x 4.6 mm, 3.5 µm column was used and HPLC grade acetonitrile, 5 millimolar (mM) ammonium format (80: 20, v/v) as mobile phase, detected by mass spectrometry operating in positive ion and multiple reaction monitoring modes.</p><p><strong>Results</strong>:<strong> </strong>The parent and production transitions for FBS and internal standard were at m/z 317.1→261.0 and 326.1→262.0 respectively. The method was validated for system suitability, specificity, carryover effect, linearity, precision, accuracy, matrix effect, sensitivity and stability. The linearity range was from 20.131 ng/ml to10015. 534 ng/ml with a correlation coefficient of 0.999. Precision results (%CV) across six quality control samples were within the limit. The percentage recovery of FBS and internal standard from matrix samples was found to be 76.57% and 75.03% respectively.</p><p><strong>Conclusion</strong>:<strong> </strong>Present study describes new LC-MS method for the quantification of FBS in a pharmaceutical formulation. According to validation results, it was found to be a simple, sensitive, accurate and precise method and also free from any kind of interference. Therefore the proposed analytical method can be used for routine analysis for the estimation of FBS in its formulation.</p>


Molecules ◽  
2020 ◽  
Vol 25 (7) ◽  
pp. 1600 ◽  
Author(s):  
Essam Ezzeldin ◽  
Muzaffar Iqbal ◽  
Yousif A. Asiri ◽  
Azza A Ali ◽  
Prawez Alam ◽  
...  

Baricitinib, is a selective and reversible Janus kinase inhibitor, is commonly used to treat adult patients with moderately to severely active rheumatoid arthritis (RA). A fast, reproducible and sensitive method of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the quantification of baricitinib in rat plasma has been developed. Irbersartan was used as the internal standard (IS). Baracitinib and IS were extracted from plasma by liquid–liquid extraction using a mixture of n-hexane and dichloromethane (1:1) as extracting agent. Chromatographic separation was performed using Acquity UPLC HILIC BEH 1.7 µm 2.1 × 50 mm column with the mobile phase consisting of 0.1% formic acid in acetonitrile and 20 mM ammonium acetate (pH 3) (97:3). The electrospray ionization in the positive-mode was used for sample ionization in the multiple reaction monitoring mode. Baricitinib and the IS were quantified using precursor-to-production transitions of m/z 372.15 > 251.24 and 429.69 > 207.35 for baricitinib and IS, respectively. The method was validated according to the recent FDA and EMA guidelines for bioanalytical method validation. The lower limit of quantification was 0.2 ng/mL, whereas the intra-day and inter-day accuracies of quality control (QCs) samples were ranged between 85.31% to 89.97% and 87.50% to 88.33%, respectively. Linearity, recovery, precision, and stability parameters were found to be within the acceptable range. The method was applied successfully applied in pilot pharmacokinetic studies.


2009 ◽  
Vol 55 (6) ◽  
pp. 1196-1202 ◽  
Author(s):  
Thomas M Annesley ◽  
Larry T Clayton

Abstract Background: Iohexol is an iodinated contrast dye that has been shown to be useful in the estimation of glomerular filtration rate (GFR) in patients with suspected renal insufficiency. We developed and validated an ultraperformance liquid chromatography (UPLC)–triple quadrupole mass spectrometry (MS/MS) assay for quantifying iohexol in human serum. Methods: Sample preparation involved dilution of 50 μL serum with 400 μL water, followed by protein precipitation with zinc sulfate and methanol containing the structural analog ioversol as the internal standard. After 1:20 dilution of the supernatant with water, 5 μL was injected into the UPLC-MS/MS system. Chromatography was performed using a Waters Oasis HLB 5-μm particle size, 2.1 × 20 mm column maintained at 50 °C. We used a 1-step acetonitrile/0.1% formic acid gradient to elute the compounds of interest at a common retention time of 0.96 min. The multiple reaction monitoring transitions used for integration and quantification were m/z 821.7→803.7 for iohexol and m/z 807.9→589.0 for ioversol in the electrospray positive ionization mode. Results: The assay was linear from 2.5 mg/L (lower limit of quantification) to 1500 mg/L iohexol, with a mean extraction efficiency of &gt;99%. Recovery of nominal target concentrations was 99%–102%. Interassay imprecision ranged from 7.9% at a concentration of 2.5 mg/L to 4.1% at 1000 mg/L. Ion suppression studies showed no matrix effects on the ionization of the 2 compounds. Conclusions: This rapid UPLC-MS/MS method can be successfully used for quantifying iohexol in human serum. .


2017 ◽  
Vol 2 ◽  
pp. 43 ◽  
Author(s):  
Martin Ongas ◽  
Joseph Standing ◽  
Bernhards Ogutu ◽  
Joseph Waichungo ◽  
James A. Berkley ◽  
...  

We have developed and validated a novel, sensitive, selective and reproducible reversed-phase high-performance liquid chromatography method coupled with electrospray ionization mass spectrometry (HPLC–ESI-MS/MS) for the simultaneous quantitation of ceftriaxone (CEF), metronidazole (MET) and hydroxymetronidazole (MET-OH) from only 50 µL of human plasma, and unbound CEF from 25 µL plasma ultra-filtrate to evaluate the effect of protein binding. Cefuroxime axetil (CEFU) was used as an internal standard (IS). The analytes were extracted by a protein precipitation procedure with acetonitrile and separated on a reversed-phase Polaris 5 C18-Analytical column using a mobile phase composed of acetonitrile containing 0.1% (v/v) formic acid and 10 mM aqueous ammonium formate pH 2.5, delivered at a flow-rate of 300 µL/min. Multiple reaction monitoring was performed in the positive ion mode using the transitions m/z555.1→m/z396.0 (CEF), m/z172.2→m/z 128.2 (MET), m/z188.0→m/z125.9 (MET-OH) and m/z528.1→m/z 364.0 (CEFU) to quantify the drugs. Calibration curves in spiked plasma and ultra-filtrate were linear (r2 ≥ 0.9948) from 0.4–300 µg/mL for CEF, 0.05–50 µg/mL for MET and 0.02 – 30 µg/mL for MET-OH. The intra- and inter- assay precisions were less than 9% and the mean extraction recoveries were 94.0% (CEF), 98.2% (MET), 99.6% (MET-OH) and 104.6% (CEF in ultra-filtrate); the recoveries for the IS were 93.8% (in plasma) and 97.6% (in ultra-filtrate). The validated method was successfully applied to a pharmacokinetic study of CEF, MET and MET-OH in hospitalized children with complicated severe acute malnutrition following an oral administration of MET and intravenous administration of CEF over the course of 72 hours.


2020 ◽  
Vol 32 (1) ◽  
pp. 49-52
Author(s):  
Xi Bao ◽  
Bingge Huang ◽  
Yiting Mao ◽  
Zhiguang Zhang ◽  
Yunfang Zhou ◽  
...  

Byakangelicol is one of coumarins from Baizhi and has been shown to inhibit the release of PGE2 from human lung epithelial A549 cells in a dose-dependent manner. A sensitive ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method was developed and full validated for the quantification of byakangelicol in rat plasma. The pharmacokinetics of byakangelicol after both intravenous (5 mg/kg) and oral (15 mg/kg) administrations were studied. Chromatographic separation was performed on an ultra-performance liquid chromatography ethylene bridged hybrid (UPLC BEH) C18 column with acetonitrile and 0.1% formic acid as the mobile phase at a flow rate of 0.4 mL/min; fargesin was used as the internal standard (IS). The following quantitative analysis of byakangelicol was utilized in the multiple reaction monitoring mode. The samples were extracted from rat plasma via protein precipitation using acetonitrile. In the concentration range of 1–2000 ng/mL, the method correlated linearity (r > 0.995) with a lower limit of quantitation (LLOQ) of 1 ng/mL. Intra-day precision was less than 11%, and inter-day precision was less than 12%. The accuracy was between 92.0% and 108.7%, the recovery was better than 89.6%, and the matrix effect was between 85.9% and 98.6%. The method was successfully applied to a pharmacokinetic study of byakangelicol after intravenous and oral administration, and the absolute bioavailability was 3.6%.


Pharmaceutics ◽  
2018 ◽  
Vol 10 (3) ◽  
pp. 123 ◽  
Author(s):  
Lingzhi Wang ◽  
Do-Dang Phan ◽  
Nicholas Syn ◽  
Xiaoqiang Xiang ◽  
Hongyan Song ◽  
...  

A sensitive and robust liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed and validated for the determination of nimbolide in mouse serum. Exemestane was used as the internal standard (IS). Here, we employed acetonitrile-based protein precipitation (PPT) for serum sample preparation, and performed chromatographic separation using an ODS Hypersil C18 column (100 mm × 2.1 mm, 5 µm) with gradient elution (0.1% formic acid in water vs 100% acetonitrile). The run time was 6 min. Instrumental analysis was performed by electrospray ionization tandem mass spectrometry (ESI-MS/MS) in the multiple-reaction monitoring (MRM) under positive mode. A good linear calibration was achieved in the 5–1000 ng/mL range. The intra- and inter-day precisions for nimbolide were ≤12.6% and ≤13.9% respectively. Intra-day accuracy ranged from 96.9–109.3%, while inter-day accuracy ranged from 94.3–110.2%. The matrix effect of nimbolide, detected but consistent at low and high concentrations, do not affect linearity of standard curve. In conclusion, we have developed and validated a sensitive analytical method for determination of a novel natural compound nimbolide in mouse serum, and it has been successfully applied to our preclinical study in investigating the pharmacokinetic properties of nimbolide, which could greatly facilitate the preclinical development of the promising lead compound for anticancer therapy.


Open Biology ◽  
2020 ◽  
Vol 10 (9) ◽  
pp. 200187
Author(s):  
Erika L. Varner ◽  
Sophie Trefely ◽  
David Bartee ◽  
Eliana von Krusenstiern ◽  
Luke Izzo ◽  
...  

Lysine lactoylation is a recently described protein post-translational modification (PTM). However, the biochemical pathways responsible for this acylation remain unclear. Two metabolite-dependent mechanisms have been proposed: enzymatic histone lysine lactoylation derived from lactoyl-coenzyme A (lactoyl-CoA, also termed lactyl-CoA), and non-enzymatic lysine lactoylation resulting from acyl-transfer via lactoyl-glutathione. While the former has precedent in the form of enzyme-catalysed lysine acylation, the lactoyl-CoA metabolite has not been previously quantified in mammalian systems. Here, we use liquid chromatography–high-resolution mass spectrometry (LC-HRMS) together with a synthetic standard to detect and validate the presence of lactoyl-CoA in cell and tissue samples. Conducting a retrospective analysis of data from previously analysed samples revealed the presence of lactoyl-CoA in diverse cell and tissue contexts. In addition, we describe a biosynthetic route to generate 13 C 3 15 N 1 -isotopically labelled lactoyl-CoA, providing a co-eluting internal standard for analysis of this metabolite. We estimate lactoyl-CoA concentrations of 1.14 × 10 −8 pmol per cell in cell culture and 0.0172 pmol mg −1 tissue wet weight in mouse heart. These levels are similar to crotonyl-CoA, but between 20 and 350 times lower than predominant acyl-CoAs such as acetyl-, propionyl- and succinyl-CoA. Overall our studies provide the first quantitative measurements of lactoyl-CoA in metazoans, and provide a methodological foundation for the interrogation of this novel metabolite in biology and disease.


2020 ◽  
Vol 10 (1) ◽  
pp. 108
Author(s):  
Hohyun Kim ◽  
Yunkyoung Choi ◽  
Yongwun An ◽  
Young-Rim Jung ◽  
Jin-Yong Lee ◽  
...  

It has been recognized that p-Coumaric acid (p-CA) has protective effects as an antioxidant, anti-inflammatory agent. A sensitive and efficient Liquid Chromatography-Mass Spectrometry (LC-MS) method for maximum determination of p-CA in human plasma has been established using Ultra-performance liquid Chromatography-tandem mass Spectrometry (UPLC-MS/MS). This study provides the developed analysis of p-CA extracted from Bambusae Caulis in Taeniam (BC) to examine the improvement of the treatment p-CA, IGF-1 and Osteocalcin level in human children which are important factors on the growth of children’s height through Pharmacokinetics/Pharmacodynamics (PK/PD) model. p-CA and internal standard in a plasma sample were detected by the Multiple Reaction Monitoring (MRM) scan mode with positive ion detection. The sample participating in the study was made of 34 subjects (placebo = 18, treatment = 16). The subjects were enrolled to be randomized to the control group and BC group. Randomized subjects took tested treatment twice a day, three capsules with oral administration (258 mg/capsule) each time after a meal. Standard calibration curves (reproducibility) were constructed and the lower limit of quantitation (LLOQ) for p-CA was found to be 0.2 ng/mL on injection of the sample into the UPLC-MS/MS system. Accuracy and precision were evaluated and the intra-accuracy was 99.2–103.8% with precision of 1.0–5.6% and inter-accuracy was 99.6–108.4% and precision of 1.3–6.4% for p-CA. The method has been successfully applied to PK/PD studies of p-CA in human plasma. The p-CA, BC in Taeniam extract increased the level of IGF-1 and Osteocalcin, and changed the height from baseline, which suggested that the p-CA could play an important role in longitudinal bone growth. Therefore, the p-CA extracted from BC in Taeniam might be a good alternative medicine to growth hormone (GH) therapy.


Sign in / Sign up

Export Citation Format

Share Document