scholarly journals Evaluation of Novel Ornamental Cladding Resistance, Comprised of GFRP Waste and Polyester Binder, within an Acid Environment

Polymers ◽  
2021 ◽  
Vol 13 (3) ◽  
pp. 448
Author(s):  
Emilia Sabău ◽  
Paul Bere ◽  
Mărioara Moldovan ◽  
Ioan Petean ◽  
Cristina Miron-Borzan

The paper presents the manufacturing technology for a material obtained from glass fiber waste, quartz sand, and polyester binder, used for ornamental building plates. The composite has a cover surface that ensures protection of the material from environment attacks and a structural material that can be subjected to chemical degradation. The mechanical properties of the obtained material were experimentally investigated through compressive mechanical tests. To observe the material’s behavior in contact with external agents (rain or acid rain, due to environmental pollution), analyses were performed in laboratory conditions. An investigation on the effects of chemical attack substances was conducted. SEM and macroscopic analyses were performed, and the surface roughness was determined for each sample area. The obtained results were statistically analyzed and showed that there is no significant difference between the surface roughness for treated and untreated samples. Furthermore, the surfaces were analyzed by X-ray diffraction and mineralogical optical microscopy in polarized light with crossed nicols. It was observed that rainwater does not affect the plate structure even if the plates are used in high-pollution environments. The material is suitable for exterior building walls from the point of view of chemical attack and resistance.

Polymers ◽  
2021 ◽  
Vol 13 (19) ◽  
pp. 3394
Author(s):  
Roman Růžek ◽  
Josef Křena ◽  
Radek Doubrava ◽  
Josef Tkadlec ◽  
Martin Kadlec ◽  
...  

The present paper documents and discusses research work associated with a newly designed passenger door structure demonstrator. The composite structure was manufactured from carbon-fiber-reinforced thermoplastic resin. A composite frame with a variable cross-section was designed, optimized, and fabricated using thermoforming technology. Both numerical simulations and experiments supported structural verification according to the damage tolerance philosophy; i.e., impact damage is presented. The Tsai-Wu and maximal stress criteria were used for damage analysis of the composite parts. Topological optimization of the metal hinges from the point of view of weight reduction was used. All expected parameters and proposed requirements of the mechanical properties were proved and completed. The door panel showed an expected numerically evaluated residual strength (ultimate structure load) as well as meeting airworthiness requirements. No impact damage propagation in the composite parts was observed during mechanical tests, even though visible impact damage was introduced into the structure. No significant difference between the numerical simulations and the experimentally measured total deformation was observed. Repeated deformation measurements during fatigue showed a nonlinear structure behavior. This can be attributed to the relaxation of thermoplastics.


1969 ◽  
Vol 62 (4_Suppla) ◽  
pp. S23-S35
Author(s):  
B.-A. Lamberg ◽  
O. P. Heinonen ◽  
K. Liewendahl ◽  
G. Kvist ◽  
M. Viherkoski ◽  
...  

ABSTRACT The distributions of 13 variables based on 10 laboratory tests measuring thyroid function were studied in euthyroid controls and in patients with toxic diffuse or toxic multinodular goitre. Density functions were fitted to the empirical data and the goodness of fit was evaluated by the use of the χ2-test. In a few instances there was a significant difference but the material available was in some respects too small to allow a very accurate estimation. The normal limits for each variable was defined by the 2.5 and 97.5 percentiles. It appears that in some instances these limits are too rigorous from the practical point of view. It is emphasized that the crossing point of the functions for euthyroid controls and hyperthyroid patients may be a better limit to use. In a preliminary analysis of the diagnostic efficiency the variables of total or free hormone concentration in the blood proved clearily superior to all other variables.


Nutrients ◽  
2021 ◽  
Vol 13 (6) ◽  
pp. 1806
Author(s):  
Virginia Chan ◽  
Alyse Davies ◽  
Lyndal Wellard-Cole ◽  
Silvia Lu ◽  
Hoi Ng ◽  
...  

Technology-enhanced methods of dietary assessment may still face common limitations of self-report. This study aimed to assess foods and beverages omitted when both a 24 h recall and a smartphone app were used to assess dietary intake compared with camera images. For three consecutive days, young adults (18–30 years) wore an Autographer camera that took point-of-view images every 30 seconds. Over the same period, participants reported their diet in the app and completed daily 24 h recalls. Camera images were reviewed for food and beverages, then matched to the items reported in the 24 h recall and app. ANOVA (with post hoc analysis using Tukey Honest Significant Difference) and paired t-test were conducted. Discretionary snacks were frequently omitted by both methods (p < 0.001). Water was omitted more frequently in the app than in the camera images (p < 0.001) and 24 h recall (p < 0.001). Dairy and alternatives (p = 0.001), sugar-based products (p = 0.007), savoury sauces and condiments (p < 0.001), fats and oils (p < 0.001) and alcohol (p = 0.002) were more frequently omitted in the app than in the 24 h recall. The use of traditional self-report methods of assessing diet remains problematic even with the addition of technology and finding new objective methods that are not intrusive and are of low burden to participants remains a challenge.


Polymers ◽  
2021 ◽  
Vol 13 (4) ◽  
pp. 543 ◽  
Author(s):  
Tzu-Yu Peng ◽  
Saiji Shimoe ◽  
Lih-Jyh Fuh ◽  
Chung-Kwei Lin ◽  
Dan-Jae Lin ◽  
...  

Poly(aryl–ether–ketone) materials (PAEKs) are gaining interest in everyday dental practices because of their natural properties. This study aims to analyze the bonding performance of PAEKs to a denture acrylic. Testing materials were pretreated by grinding, sandblasting, and priming prior to polymerization with the denture acrylic. The surface morphologies were observed using a scanning electron microscope and the surface roughness was measured using atomic force microscopy. The shear bond strength (SBS) values were determined after 0 and 2500 thermal cycles. The obtained data were analyzed using a paired samples t-test and Tukey’s honestly significant difference (HSD) test (α = 0.05). The surface characteristics of testing materials after different surface pretreatments showed obvious differences. PAEKs showed lower surface roughness values (0.02–0.03 MPa) than Co-Cr (0.16 MPa) and zirconia (0.22 MPa) after priming and sandblasting treatments (p < 0.05). The SBS values of PAEKs (7.60–8.38 MPa) met the clinical requirements suggested by ISO 10477 (5 MPa). Moreover, PAEKs showed significantly lower SBS reductions (p < 0.05) after thermal cycling fatigue testing compared to Co-Cr and zirconia. Bonding performance is essential for denture materials, and our results demonstrated that PAEKs possess good resistance to thermal cycling fatigue, which is an advantage in clinical applications. The results imply that PAEKs are potential alternative materials for the removable of prosthetic frameworks.


2021 ◽  
pp. 096739112110055
Author(s):  
Gunce Ozan ◽  
Meltem Mert Eren ◽  
Cansu Vatansever ◽  
Ugur Erdemir

Surface sealants are reported to ensure surface smoothness and improve the surface quality of composite restorations. These sealants should also reduce the bacterial adhesion on composite surfaces however, there is not much information regarding their performance on bulk-fill composite materials. The aim of this study was to evaluate the effect of surface sealant application on surface roughness and bacterial adhesion of various restorative materials. Disc-shaped samples were prepared from a compomer, a conventional composite and three bulk-fill composites. Specimens of each group were divided into two groups (n = 9): with/without surface sealant (Biscover LV, [BLV]). Surface roughness values were examined by profilometry and two samples of each group were examined for bacterial adhesion on a confocal laser scanning microscope (CLSM). Bacterial counts were calculated by both broth cultivation and microscopic images. Results were analyzed with one-way ANOVA and Bonferroni/Dunn tests. Following the BLV application, there was a decrease in the surface roughness values of all groups however, only Tetric N-Ceram Bulk and Beautifil-Bulk groups showed significantly smoother surfaces (p < 0.001). There were no significant differences among material groups without BLV application. Evaluating bacterial adhesion after BLV application, conventional composite had the lowest values among all followed by the compomer group. Beautifil-Bulk had significantly the highest bacterial adhesion (p < 0.05), followed by Tetric N-Ceram Bulk group. Without BLV application, there was no significant difference among bacterial adhesion values of groups (p > 0.05). CLSM images showed cell viability in groups. Bulk-fill composites showed higher bacterial adhesion than conventional composite and compomer materials. The surface sealant was found to be highly effective in lowering bacterial adhesion, but not so superior in smoothing the surfaces of restorative materials. So, surface sealants could be used on the restorations of patients with high caries risk.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Hiroki Hihara ◽  
Ryo Tagaino ◽  
Jumpei Washio ◽  
Kittipong Laosuwan ◽  
Dimas Prasetianto Wicaksono ◽  
...  

Abstract Background Removal of oral biofilm from the oral mucosa is essential for preventing risk of respiratory and gastrointestinal infection in elderly people. Currently, no device is available which can remove oral biofilm from oral mucosa effectively and safely. Therefore, the effectiveness and safety of the Micro Scale Mist UNIT (MSM-UNIT), a newly developed dental plaque removal device utilizing high speed sprays of fine water droplets, were evaluated for biofilm removal, including the rate and surface roughness for simulated tooth surface and mucous membrane. Methods Simulated tooth and oral mucosa coated with an artificial biofilm of Streptococcus mutans were used for evaluation of effectiveness, with uncoated substrates as the controls. The MSM-UNIT and a conventional air ablation device were operated under recommended instructions. The effectiveness was evaluated from the rate of removal of the biofilm, and the safety was evaluated from the damage observed by scanning electron microscope and surface roughness. Results The biofilm removal rate of the MSM-UNIT was significantly higher than that of AIRFLOW. Little damage was observed in the area treated by the MSM-UNIT. The surface roughness of the MSM-UNIT treated area on simulated tooth surface and oral mucosa showed no significant difference to the control area. In contrast, cracks and powder were observed in the area treated by AIRFLOW. In particular, the surface roughness of the AIRFLOW treated area for Toughsilon was significantly larger than that of the control. Conclusions The MSM-UNIT could be used safely and effectively for removing biofilm not only on simulated tooth surfaces but also simulated mucous membrane. The MSM-UNIT has no harmful effect on teeth or oral mucosa, and may be used for comprehensive oral care for patients during nursing care and the perioperative period.


Materials ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1550
Author(s):  
Soo-Yeon Yoo ◽  
Seong-Kyun Kim ◽  
Seong-Joo Heo ◽  
Jai-Young Koak ◽  
Joung-Gyu Kim

Previous studies on accuracy of three-dimensional (3D) printed model focused on full arch measurements at few points. The aim of this study was to examine the dimensional accuracy of 3D-printed models which were teeth-prepped for three-unit fixed prostheses, especially at margin and proximal contact areas. The prepped dental model was scanned with a desktop scanner. Using this reference file, test models were fabricated by digital light processing (DLP), Multi-Jet printing (MJP), and stereo-lithography apparatus (SLA) techniques. We calculated the accuracy (trueness and precision) of 3D-printed models on 3D planes, and deviations of each measured points at buccolingual and mesiodistal planes. We also analyzed the surface roughness of resin printed models. For overall 3D analysis, MJP showed significantly higher accuracy (trueness) than DLP and SLA techniques; however, there was not any statistically significant difference on precision. For deviations on margins of molar tooth and distance to proximal contact, MJP showed significantly accurate results; however, for a premolar tooth, there was no significant difference between the groups. 3D color maps of printed models showed contraction buccolingually, and surface roughness of the models fabricated by MJP technique was observed as the lowest. The accuracy of the 3D-printed resin models by DLP, MJP, and SLA techniques showed a clinically acceptable range to use as a working model for manufacturing dental prostheses


2000 ◽  
Vol 09 (06) ◽  
pp. 669-686 ◽  
Author(s):  
MARÍA E. ANGULO ◽  
GUILLERMO A. MENA MARUGÁN

Linearly polarized cylindrical waves in four-dimensional vacuum gravity are mathematically equivalent to rotationally symmetric gravity coupled to a Maxwell (or Klein–Gordon) field in three dimensions. The quantization of this latter system was performed by Ashtekar and Pierri in a recent work. Employing that quantization, we obtain here a complete quantum theory which describes the four-dimensional geometry of the Einstein–Rosen waves. In particular, we construct regularized operators to represent the metric. It is shown that the results achieved by Ashtekar about the existence of important quantum gravity effects in the Einstein–Maxwell system at large distances from the symmetry axis continue to be valid from a four-dimensional point of view. The only significant difference is that, in order to admit an approximate classical description in the asymptotic region, states that are coherent in the Maxwell field need not contain a large number of photons anymore. We also analyze the metric fluctuations on the symmetry axis and argue that they are generally relevant for all of the coherent states.


Author(s):  
Saeed Noorollahian ◽  
Farinaz Shirban ◽  
Vahid Mojiri

Introduction: The daily use of orthodontic removable plates can interfere with the self-cleansing function of the mouth. Although various techniques have been proposed for cleaning removable orthodontic appliances, there is no consensus on the use of a safe method that preserves the physical properties of the appliance. This study aimed to investigate the effect of using hydrochloric acid (10%, for removal of mineral deposits) and sodium hypochlorite (5.25%, to remove organic matter and discolorations) on surface hardness and roughness of self-cure orthodontic acrylic resins. Materials & Methods: This cross-sectional laboratory study was conducted in the fall of 2017 at Isfahan University of Medical science and Isfahan University of Technology. In this study two orthodontic acrylic resins (Orthocryl® and Acropars®) were used. Eighty samples (12×10×3 mm) from each one were fabricated and divided into four groups (n = 20). Group 1: 15 minutes immersion in household cleaner liquid (Hydrochloric acid, 10%) followed by15 minutes immersion in household bleach liquid (Sodium Hypochlorite, 5.25%). In group 2, immersions were repeated just like group two times and in group 3, were done three times. Group 4 was as control and had no immersion. The surface hardness and roughness of samples were measured. Data were analyzed with Two Way ANOVA and the significance level was set at 0.05. Results: The number of immersion procedures did not significantly affect the surface hardness (p value = 0.958) and surface roughness (p value = 0.657) in the different study groups. There was no significant difference in the surface hardness between the two acrylic resin brands (p value = 0.077); however, Acropars acrylic resin samples exhibited significantly higher surface roughness compared to the Orthocryl acrylic resin samples(p value < 0.001). Conclusion: 15 minutes of immersion in 10% HCl, followed by 15 minutes of immersion in 5.25% NaOCl and repetition of the procedure three times did not significantly affect the surface hardness and roughness of self-cured acrylic resins.


Sign in / Sign up

Export Citation Format

Share Document