scholarly journals A New Submersion Detection Sensor Using Two Resistance Temperature Detectors Operating on the Thermal Equilibrium Principle

Sensors ◽  
2019 ◽  
Vol 19 (19) ◽  
pp. 4310 ◽  
Author(s):  
Youngjun Lee ◽  
Young Sam Lee

In this study, a new submersion detection sensor with improved reliability and stability is proposed. The new sensor uses two Resistance Temperature Detectors (RTDs) and operates on the thermal equilibrium principle. The submersion detection sensor controls two RTDs that maintain a constant temperature difference between them in the surrounding environment. The first RTD is used as a reference sensor to measure ambient temperature and the second RTD is supplied with higher current than the reference sensor for self-heating. When submerged, because the thermal conductivity and convective heat transfer coefficient of water are higher than that of air, the temperature difference between the two RTDs is lower in water than in air based on the thermal equilibrium principle. Under these conditions, a submersion detector with a signal conditioning circuit detects these temperature differences. The static performance of the proposed sensor was evaluated by checking whether malfunctions occurred at varying ambient temperatures, differing humidities, and when there was rainfall. In addition, the dynamic performance was evaluated using the response time at varying ambient air temperatures before submersion and with changing water temperatures after submersion, as a metric. The proposed submersion detection sensor is expected to find useful application in aircrafts, ships, and various other industrial fields.

Author(s):  
Daniel M. Madyira ◽  
Ranwedzi P. Mukhodobwane ◽  
Tien C. Jen

Free cooling involves using a thermal energy storage medium such as a phase change material (PCM) in order to store the ambient “cold” during the night when ambient air temperatures are lower compared to the indoor building temperatures and release this stored “cold” by using a heat transfer fluid (i.e. air) into the building during the day when higher ambient temperatures are experienced especially during the summer months. This paper assesses the free cooling potential in South Africa by using a set of Rubitherm RT25HC PCM plates. The performance of these PCM plates is assessed by benchmarking the ambient air cooled by the PCM plates during the day against the defined thermal comfort temperatures requirements. The influence of varying the air flow rate on the availability of thermal comfort temperatures at the PCM rig outlet is also studied. The results clearly show the potential of using PCM’s as a means of cooling higher ambient air temperature which is experienced in hot summer months to within thermal comfort temperatures for human occupancy in a building.


2018 ◽  
Vol 40 (4) ◽  
pp. 41-49
Author(s):  
V.G. Kramar

The purpose of this work is to determine the duration of the ambient air temperatures of different gradations during heating periods in different regions of Ukraine, based on the climatic data for 2005-2018 and the construction of load duration curves for the respective regions. The load duration curve (Rossander graph) is used to determine the number of maximum thermal load using hours, as well as in cases where the thermal load is provided by several sources - to determine their level of participation in the total annual heat energy production. It is important for a more accurate technical and economic evaluation of implementation results for some thermal energy sources. The climatic data of meteorological stations located in the regional centers of Ukraine and the capital of Autonomous Republic of Crimea, or as close as possible to them, were used for the study. The climatic data of heating periods from the autumn of 2005 to 2018 were considered. As the result of study, the duration of various degrees of ambient air temperature in the heating period was determined for all the regional centers of Ukraine. Taking into account the significant climatic differences in the regions of Ukraine, the results were analyzed separately for two groups of regions, for which, according to averaged data, load duration curves were determined. The examples of using of obtained results for calculations are given. On the basis of obtained data regarding duration of ambient temperatures higher than +8°C during the heating season, the energy saving potential of implementation of weather-dependent regulation of heat energy production for heating purposes in different regions was theoretically estimated, which is, on average, 8.4% for the first temperature zone (north, center) and 13% for the second zone (south).


1983 ◽  
Vol 115 (7) ◽  
pp. 855-858 ◽  
Author(s):  
P. Barbosa ◽  
M. G. Waldvogel ◽  
N. L. Breisch

AbstractSurface and internal temperatures of bags made by Thyridopteryx ephemeraeformis (Haworth) as well as ambient temperatures were recorded in sun and shade. Temperatures of bags in both shaded and exposed areas of the tree were significantly higher than ambient air temperatures. Bag surface temperatures were not significantly different from internal bag temperatures. Differences between internal, surface, and ambient temperatures could not be attributed to host tree species. Finally, there were no significant differences in temperature between bags with and without larvae.


Author(s):  
Ahmed M Abdel-Ghanya ◽  
Ibrahim M Al-Helal

Plastic nets are extensively used for shading purposes in arid regions such as in the Arabian Peninsula. Quantifying the convection exchange with shading net and understanding the mechanisms (free, mixed and forced) of convection are essential for analyzing energy exchange with shading nets. Unlike solar and thermal radiation, the convective energy, convective heat transfer coefficient and the nature of convection have never been theoretically estimated or experimentally measured for plastic nets under arid conditions. In this study, the convected heat exchanges with different plastic nets were quantified based on an energy balance applied to the nets under outdoor natural conditions. Therefore, each net was tacked onto a wooden frame, fixed horizontally at 1.5-m height over the floor. The downward and upward solar and thermal radiation fluxes were measured below and above each net on sunny days; also the wind speed over the net, and the net and air temperatures were measured, simultaneously. Nets with different porosities, colors and texture structures were used for the study. The short and long wave’s radiative properties of the nets were pre-determined in previous studies to be used. Re and Gr numbers were determined and used to characterize the convection mechanism over each net. The results showed that forced and mixed convection are the dominant modes existing over the nets during most of the day and night times. The nature of convection over nets depends mainly on the wind speed, net-air temperature difference and texture shape of the net rather than its color and its porosity.


1975 ◽  
Vol 97 (1) ◽  
pp. 47-53 ◽  
Author(s):  
R. E. Forbes ◽  
J. W. Cooper

Natural convection in horizontal layers of water cooled from above to near freezing was studied analytically. The water was confined laterally and underneath by rigid insulators, and the upper horizontal surface was subjected to: (1) a constant 0C temperature, rigid conducting boundary, and (2) a free, water to air convection boundary condition, in which the convective heat transfer coefficient was held constant at values of 5.68 W/m2 · K and 284 W/m2 · K (1.0 and 50.0 Btu/hr ft2F) and the temperature of the ambient air was maintained at 0C. The ratios of the width to the depth of the rectangular water layers under consideration were W/D = 1, 3, and 6. Initially the water is assumed to be at a uniform temperature of either 4C or 8C, and then the upper surface boundary condition was suddenly applied. It was observed in all cases for which the initial water temperature was 4C, that the water remained stagnant and became thermally stratified. Heat transfer application of either of the surface boundary conditions to water initially at 8C produced large convective eddies extending from the bottom to the top of the layer of water. As the liquid layer cooled further, two distinct horizontal regions appeared, the 4C isothermal line separating the two. This produces a region of hydrodynamic instability in the fluid since the maximum density fluid (4C) is physically located above the less dense fluid in the lower portion of the cavity. The large eddies which appeared initially were confined to the hydrodynamically unstable region bounded by the 4C isotherm and the bottom of the cavity. The action of viscous shearing forces upon the stable water above the 4C isotherm produced a second “layer” of eddies. An alternating direction implicit finite difference method was used to solve the coupled system of partial differential equations. The paper presents transient isotherms and streamlines and a discussion of the effect of maximum density on the flow patterns.


Author(s):  
Jielin Luo ◽  
Qin Wang ◽  
Zhen Zhao ◽  
Kaiyin Yang ◽  
Guangming Chen ◽  
...  

Abstract Considering the issues of environmental pollution and energy efficiency, heat pumps are gradually replacing traditional coal combustion for heating at low ambient temperatures. In this paper, eco-friendly CO2/HCs with large temperature glides are applied in a single-stage recuperative heat pump water heater. Its heating performance is theoretically investigated under the working condition of producing circulating hot water in typical winter of northern China, with medium temperature difference between supply/return water and large temperature difference between air inlet and water inlet. Due to its simple structure, low initial investment and high efficiency, its potential for producing circulating hot water is demonstrated. Exergy analyses are conducted to reveal the significant influence of the exergy losses of heat exchanger on system performance. For specified CO2/HC, optimal COP is obtained through global optimization of cycle pressures and mixture concentration. The heating performances of different CO2/HCs are compared, among which CO2/R600 and CO2/R600a behave better. Meanwhile, a typical vapor-injection cycle is used to demonstrate priorities on the heating performance of this recuperative cycle, in which the COP of recuperative cycle using CO2/R600 is more than 3.4% higher than that of the vapor-injection cycle. The results obtained in this paper provide a simple and efficient solution for producing circulating hot water at low ambient temperatures.


1988 ◽  
Vol 65 (5) ◽  
pp. 1984-1989 ◽  
Author(s):  
J. H. Bittel ◽  
C. Nonotte-Varly ◽  
G. H. Livecchi-Gonnot ◽  
G. L. Savourey ◽  
A. M. Hanniquet

The relationship between the physical fitness level (maximal O2 consumption, VO2max) and thermoregulatory reactions was studied in 17 adult males submitted to an acute cold exposure. Standard cold tests were performed in nude subjects, lying for 2 h in a climatic chamber at three ambient air temperatures (10, 5, and 1 degrees C). The level of physical fitness conditioned the intensity of thermoregulatory reactions to cold. For all subjects, there was a direct relationship between physical fitness and 1) metabolic heat production, 2) level of mean skin temperature (Tsk), 3) level of skin conductance, and 4) level of Tsk at the onset of shivering. The predominance of thermogenic or insulative reactions depended on the intensity of the cold stress: insulative reactions were preferential at 10 degrees C, or even at 5 degrees C, whereas colder ambient temperature (1 degree C) triggered metabolic heat production abilities, which were closely related to the subject's physical fitness level. Fit subjects have more efficient thermoregulatory abilities against cold stress than unfit subjects, certainly because of an improved sensitivity of the thermoregulatory system.


2013 ◽  
Vol 30 (8) ◽  
pp. 1757-1765 ◽  
Author(s):  
Sayed-Hossein Sadeghi ◽  
Troy R. Peters ◽  
Douglas R. Cobos ◽  
Henry W. Loescher ◽  
Colin S. Campbell

Abstract A simple analytical method was developed for directly calculating the thermodynamic wet-bulb temperature from air temperature and the vapor pressure (or relative humidity) at elevations up to 4500 m above MSL was developed. This methodology was based on the fact that the wet-bulb temperature can be closely approximated by a second-order polynomial in both the positive and negative ranges in ambient air temperature. The method in this study builds upon this understanding and provides results for the negative range of air temperatures (−17° to 0°C), so that the maximum observed error in this area is equal to or smaller than −0.17°C. For temperatures ≥0°C, wet-bulb temperature accuracy was ±0.65°C, and larger errors corresponded to very high temperatures (Ta ≥ 39°C) and/or very high or low relative humidities (5% < RH < 10% or RH > 98%). The mean absolute error and the root-mean-square error were 0.15° and 0.2°C, respectively.


1958 ◽  
Vol 38 (2) ◽  
pp. 148-159 ◽  
Author(s):  
M. A. MacDonald ◽  
J. M. Bell

This report presents effects of low temperatures on the feed consumption and efficiency of milk production of six mature, lactating, Holstein-Friesian cows that were confined in stanchions for three fortnightly experimental periods during which ambient temperatures measured in degree-hours per day (d-h/day) ranged from 110 to 1152 and daily minimum ambient air temperature (DMAAT) varied from 0° to 38°F. Applying results obtained, it was calculated that as temperatures decreased, i.e., d-h/day increased from 100 to 1200 and DMAAT decreased from 40° to 0°F, average daily intakes of total dry matter, hay, and gross and digestible Calories increased approximately 6.4 lb., 5.3 lb., 13 Therms and 9 Therms, respectively. Each of these increases was statistically significant at the 1 per cent level. Reductions in temperature also decreased gross and net caloric efficiencies of milk production approximately 10 and 8.5 per cent, respectively. These decreases were significant at the 2 per cent level. No correlation was evident between crude protein utilization and temperature.Results indicated that thermal stress was not overcome adequately by supplementary hay intake alone and that appetite stimulation by low temperatures had a carry-over effect continuing at least 24 hours. For continued efficient milk production during winters where low ambient temperatures are prevalent these results suggest it is necessary to provide some form of building insulation, ambient heat and/or provide a high energy supplement to otherwise adequate production rations.


Energies ◽  
2019 ◽  
Vol 12 (6) ◽  
pp. 1079 ◽  
Author(s):  
Martin Belusko ◽  
Raymond Liddle ◽  
Alemu Alemu ◽  
Edward Halawa ◽  
Frank Bruno

Dew point cooling (DPC) is a novel indirect evaporative cooling concept capable of delivering air temperatures approaching the dew point. Coupling this technology with CO2 refrigeration is well suited to minimising transcritical operation when the coefficient of performance (COP) is dramatically reduced in hot climates. A substantial experimental program was conducted to characterise this combination by testing a 20 kW CO2 refrigeration system subject to ambient temperatures above 40 °C. It was demonstrated that DPC operation not only avoided transcritical operation during such weather conditions, but also increased the COP by up to 140% compared to the conventional system. The combination of these technologies was successfully mathematically modelled, from which the optimum condenser inlet air temperature was identified for each condenser temperature. Using this optimum condition, it was possible to maximise the COP for a range of conditions applicable to the psychometric chart. An annual case study for Adelaide, Australia was conducted which demonstrated that optimally coupling DPC with CO2 refrigeration can reduce the annual energy consumption and peak demand by 16% and 47%, respectively, compared to a conventional CO2 booster system. Furthermore, the number of hours of transcritical operation was reduced from 3278 to 27.


Sign in / Sign up

Export Citation Format

Share Document