scholarly journals Use of PVDF Wire Sensors for Leakage Localization in a Fluid-Filled Pipe

Sensors ◽  
2020 ◽  
Vol 20 (3) ◽  
pp. 692 ◽  
Author(s):  
Pingling Sun ◽  
Yan Gao ◽  
Boao Jin ◽  
Michael J. Brennan

The detection and location of pipeline leakage can be deduced from the time difference between the arrival leak signals measured by sensors placed at the pipe access points on either side of a suspected leak. Progress has been made in this area to offer a potential improvement over the conventional cross-correlation method for time delay estimation. This paper is concerned with identifying suitable sensors that can be easily deployed to monitor the pipe vibration due to the propagation of leak noise along the pipeline. In response to this, based on the low-frequency propagation characteristics of leak noise in our previous study, polyvinylidene fluoride (PVDF) wire sensors are proposed as a potential solution to detect the pipeline leak signals. Experimental investigations were carried out at a leak detection pipe rig built in the Chinese Academy of Sciences. Their performances for leak detection were shown in comparison with hydrophones. It is suggested that with special considerations given to aspects pertaining to non-intrusive deployment and low cost, the PVDF wire sensors are of particular interest and may lead to a promising replacement for commercial leak noise transducers.

Sensors ◽  
2020 ◽  
Vol 20 (18) ◽  
pp. 5042
Author(s):  
Salvatore A. Pullano ◽  
Maria Giovanna Bianco ◽  
Davide C. Critello ◽  
Michele Menniti ◽  
Antonio La Gatta ◽  
...  

Low frequency ultrasounds in air are widely used for real-time applications in short-range communication systems and environmental monitoring, in both structured and unstructured environments. One of the parameters widely evaluated in pulse-echo ultrasonic measurements is the time of flight (TOF), which can be evaluated with an increased accuracy and complexity by using different techniques. Hereafter, a nonstandard cross-correlation method is investigated for TOF estimations. The procedure, based on the use of template signals, was implemented to improve the accuracy of recursive TOF evaluations. Tests have been carried out through a couple of 60 kHz custom-designed polyvinylidene fluoride (PVDF) hemicylindrical ultrasonic transducers. The experimental results were then compared with the standard threshold and cross-correlation techniques for method validation and characterization. An average improvement of 30% and 19%, in terms of standard error (SE), was observed. Moreover, the experimental results evidenced an enhancement in repeatability of about 10% in the use of a recursive positioning system.


Author(s):  
Nor Afifah Borhan ◽  
Noor Asniza Murad

<p>Monopole antenna is widely used in many communication systems especially in broadcasting where omnidirectional pattern allow the 360-degree coverage. However, at low frequency the conventional design may require miniaturization to fit in versatile spaces. Thus, this paper discusses a low cost, compact CPW-fed curved meander line monopole antenna (MLMA) designed to operate at 0.9 GHz GSM band. The overall dimension is 25mm x 80mm. The antenna is well matched at required GSM band with the bandwidth from 0.88 GHz to 0.93 GHz. Comparison between the conventional MLMA and curved (MLMA) is made in term of return loss and gain. It was found that the curved MLMA has a better gain compared to the conventional MLMA which is 1.472 dB.</p>


2020 ◽  
Vol 324 (2) ◽  
pp. 262-272
Author(s):  
I.V. Doronin ◽  
T.N. Dujsebayeva ◽  
K.M. Akhmedenov ◽  
A.G. Bakiev ◽  
K.N. Plakhov

The article specifies the type locality of the Steppe Ribbon Racer. The holotype Coluber (Taphrometopon) lineolatus Brandt, 1838 is stored in the reptile collection of the Zoological Institute of the Russian Academy of Sciences (ZISP No 2042). Literature sources provide different information about the type locality. A mistake has been made in the title of the work with the original species description: the western coast of the sea was indicated instead of the eastern one. The place of capture was indicated as “M. Caspium” (Caspian Sea) on the label and in the reptile inventory book of the Zoological Museum of the Academy of Sciences. The specimen was sent to the museum by G.S. Karelin. The “1842” indicated on the labels and in the inventory book cannot be the year of capture of the type specimen, just as the “1837” indicated by A.M. Nikolsky. In 1837, Karelin was in Saint Petersburg and in 1842 in Siberia. Most likely, 1837 is the year when the collection arrived at the Museum, and 1842 is the year when the information about the specimen was recorded in the inventory book (catalog) of the Zoological Museum of the Academy of Sciences. In our opinion, the holotype was caught in 1932. From Karelin’s travel notes of the expedition to the Caspian Sea in 1832, follows that the snake was recorded in two regions adjacent to the eastern coast of the Caspian Sea – Ungoza Mountain (“Mangyshlak Mountains”) and site of the Western Chink of Ustyurt between Zhamanairakty and Kyzyltas Mountains (inclusive) on the northeast coast of Kaydak Sor (“Misty Mountains”). In our article, Karelin’s route to the northeastern coast of the Caspian Sea in 1832 and photographs of these localities are given. The type locality of Psammophis lineolatus (Brandt, 1838) should be restricted to the Mangystau Region of the Kazakhstan: Ungoza Mountain south of Sarytash Gulf, Mangystau (Mangyshlak) Penninsula (44°26´ N, 51°12´ E).


2021 ◽  
Author(s):  
Xiaojing Zhang ◽  
xinyi Ge ◽  
Zhigang Shen ◽  
Han Ma ◽  
Jingshi Wang ◽  
...  

Compared with environmentally harmful binder polyvinylidene fluoride (PVDF) in Li-ion batteries (LIBs), water-based binders have many advantages, such as low cost, rich sources and environmental friendliness. In this study, various...


Nanomaterials ◽  
2020 ◽  
Vol 11 (1) ◽  
pp. 28
Author(s):  
Anastasios I. Tsiotsias ◽  
Nikolaos D. Charisiou ◽  
Ioannis V. Yentekakis ◽  
Maria A. Goula

CO2 methanation has recently emerged as a process that targets the reduction in anthropogenic CO2 emissions, via the conversion of CO2 captured from point and mobile sources, as well as H2 produced from renewables into CH4. Ni, among the early transition metals, as well as Ru and Rh, among the noble metals, have been known to be among the most active methanation catalysts, with Ni being favoured due to its low cost and high natural abundance. However, insufficient low-temperature activity, low dispersion and reducibility, as well as nanoparticle sintering are some of the main drawbacks when using Ni-based catalysts. Such problems can be partly overcome via the introduction of a second transition metal (e.g., Fe, Co) or a noble metal (e.g., Ru, Rh, Pt, Pd and Re) in Ni-based catalysts. Through Ni-M alloy formation, or the intricate synergy between two adjacent metallic phases, new high-performing and low-cost methanation catalysts can be obtained. This review summarizes and critically discusses recent progress made in the field of bimetallic Ni-M (M = Fe, Co, Cu, Ru, Rh, Pt, Pd, Re)-based catalyst development for the CO2 methanation reaction.


2020 ◽  
Vol 1 (1) ◽  
Author(s):  
Stelbin Peter Figerez ◽  
Sudeshna Patra ◽  
G Rajalakshmi ◽  
Tharangattu N Narayanan

Abstract Respiratory masks having similar standards of ‘N95’, defined by the US National Institute for Occupational Safety and Health, will be highly sought after, post the current COVID-19 pandemic. Here, such a low-cost (∼$1/mask) mask design having electrostatic rechargeability and filtration efficiency of &gt;95% with a quality factor of ∼20 kPa−1 is demonstrated. This filtration efficacy is for particles of size 300 nm. The tri-layer mask, named PPDFGO tri, contains nylon, modified polypropylene (PPY), and cotton nonwoven fabrics as three layers. The melt-spun PPY, available in a conventional N95 mask, modified with graphene oxide and polyvinylidene fluoride mixture containing paste using a simple solution casting method acts as active filtration layer. The efficacy of this tri-layer system toward triboelectric rechargeability using small mechanical agitations is demonstrated here. These triboelectric nanogenerator (TENG)-assisted membranes have high electrostatic charge retention capacity (∼1 nC/cm2 after 5 days in ambient condition) and high rechargeability even in very humid conditions (&gt;80% RH). A simple but robust permeability measurement set up is also constructed to test these TENG-based membranes, where a flow rate of 30–35 L/min is maintained during the testing. Such a simple modification to the existing mask designs enabling their rechargeability via external mechanical disturbances, with enhanced usability for single use as well as for reuse with decontantamination, will be highly beneficial in the realm of indispensable personal protective equipment.


2014 ◽  
Vol 657 ◽  
pp. 306-310
Author(s):  
Lăcrămioara Apetrei ◽  
Vasile Rață ◽  
Ruxandra Rață ◽  
Elena Raluca Bulai

Research evolution timely tendencies, in the nonconventional technologies field, are: manufacture conditions optimization and complex equipments design. The increasing of ultrasonic machining use, in various technologies is due to the expanding need of a wide range materials and high quality manufacture standards in many activity fields. This paper present a experimental study made in order to analyze the welded zone material structure and welding quality. The effects of aluminium ultrasonic welding parameters such as relative energy, machining time, amplitude and working force were compared through traction tests values and microstructural analysis. Microhardness tests were, also, made in five different points, two in the base material and three in the welded zone, on each welded aluminium sample. The aluminum welding experiments were made at the National Research and Development Institute for Welding and Material Testing (ISIM) Timişoara. The ultrasonic welding temperature is lower than the aluminium melting temperature, that's so our experiments reveal that the aluminium ultrasonic welding process doesn't determine the appearance of moulding structure. In the joint we have only crystalline grains deformation, phase transformation and aluminium diffusion.


2021 ◽  
Vol 13 (1) ◽  
Author(s):  
Persona Paolo ◽  
Valeri Ilaria ◽  
Zarantonello Francesco ◽  
Forin Edoardo ◽  
Sella Nicolò ◽  
...  

Abstract Background During COVID-19 pandemic, optimization of the diagnostic resources is essential. Lung Ultrasound (LUS) is a rapid, easy-to-perform, low cost tool which allows bedside investigation of patients with COVID-19 pneumonia. We aimed to investigate the typical ultrasound patterns of COVID-19 pneumonia and their evolution at different stages of the disease. Methods We performed LUS in twenty-eight consecutive COVID-19 patients at both admission to and discharge from one of the Padua University Hospital Intensive Care Units (ICU). LUS was performed using a low frequency probe on six different areas per each hemithorax. A specific pattern for each area was assigned, depending on the prevalence of A-lines (A), non-coalescent B-lines (B1), coalescent B-lines (B2), consolidations (C). A LUS score (LUSS) was calculated after assigning to each area a defined pattern. Results Out of 28 patients, 18 survived, were stabilized and then referred to other units. The prevalence of C pattern was 58.9% on admission and 61.3% at discharge. Type B2 (19.3%) and B1 (6.5%) patterns were found in 25.8% of the videos recorded on admission and 27.1% (17.3% B2; 9.8% B1) on discharge. The A pattern was prevalent in the anterosuperior regions and was present in 15.2% of videos on admission and 11.6% at discharge. The median LUSS on admission was 27.5 [21–32.25], while on discharge was 31 [17.5–32.75] and 30.5 [27–32.75] in respectively survived and non-survived patients. On admission the median LUSS was equally distributed on the right hemithorax (13; 10.75–16) and the left hemithorax (15; 10.75–17). Conclusions LUS collected in COVID-19 patients with acute respiratory failure at ICU admission and discharge appears to be characterized by predominantly lateral and posterior non-translobar C pattern and B2 pattern. The calculated LUSS remained elevated at discharge without significant difference from admission in both groups of survived and non-survived patients.


Sign in / Sign up

Export Citation Format

Share Document