scholarly journals Long-Term Assessment of the In Vitro Corrosion Resistance of Biomimetic ACP Coatings Electrodeposited from an Acetate Bath

2021 ◽  
Vol 12 (1) ◽  
pp. 12
Author(s):  
Patrycja Osak ◽  
Joanna Maszybrocka ◽  
Julian Kubisztal ◽  
Patryk Ratajczak ◽  
Bożena Łosiewicz

Calcium phosphate coatings are able to improve the osseointegration process due to their chemical composition, which is similar to that of bone tissues. In this work, to increase the long-term corrosion resistance and to improve the osseointegration process of commercially pure titanium Grade 4 (CpTi G4), biomimetic amorphous calcium phosphate (ACP) coatings were electrodeposited for the first time from an acetate bath with a pH level of 7.0 and a Ca:P ratio of 1.67. ACP coatings were obtained on CpTi G4 substrate subjected to sandblasting and autoclaving using electrochemically assisted deposition at a potential of −3 V relative to the open circuit potential for 30 min at room temperature. SEM, EDS, 2D roughness profiles, amplitude-sensitive eddy current method, and Kelvin scanning probe were used for the surface characterization of the biomaterial under study. In vitro corrosion resistance tests were conducted for 21 days in artificial saliva using open circuit potential, polarization curves, and electrochemical impedance spectroscopy measurements. The passive-transpassive behavior was revealed for the obtained ACP coatings. The long-term corrosion resistance test showed a deterioration of the protective properties for CpTi G4 uncoated and coated with ACP with immersion time. The mechanism and kinetics of the pitting corrosion on the CpTi G4|TiO2|ACP coating system are discussed in detail.

2008 ◽  
Vol 59 (9) ◽  
Author(s):  
Daniel Mareci ◽  
Igor Cretescu ◽  
Neculai Aelenei ◽  
Julia Claudia Mirza Rosca

The electrochemical behavior of a three Ag-Pd alloys used in dental prosthetics construction for crowns and bridges was studied in artificial saliva using the polarization curves and electrochemical impedance spectroscopy (EIS). The corrosion resistance was evaluated by means of the corrosion currents value and by coulometric analysis. The open circuit potential of Ag-Pd are attributed to dealloying followed by surface enrichment with Ag and the possible formation of an insoluble AgCl surface film on the respective alloy surfaces. Our results have shown that these alloys have a somewhat good corrosion resistance in artificial saliva. When increasing the content of Cu, corrosion resistance decreases. The passivation of all samples occurred spontaneously at the open circuit potential. The electrochemical properties of the spontaneously passivated electrodes at the open circuit potential were studied by EIS. The polarization resistance (Rp) and the electrode capacitance (Cdl) were determined. The polarisation resistance of all the samples increases with the immersion time. The polarization resistances are largest and decrease when increasing the content of Cu. Cu reduces the Ag-Pd alloy corrosion resistance. The present study, thought limited, has shown that electrochemical characteristics can be use to identify such alloys. Knowledge of the in vitro corrosion behaviour of these alloys may lead to better understanding of any biologically adverse effects in vitro.


2021 ◽  
Vol 6 (1) ◽  
pp. 5
Author(s):  
Patrycja Osak ◽  
Maciej Zubko ◽  
Julian Kubisztal ◽  
Joanna Maszybrocka ◽  
Bożena Łosiewicz

Titanium Grade 4 (G4) is the most commonly used material for dental implants due to its excellent biocompatibility and mechanical properties. However, titanium implants require a rough surface that can increase the biomechanical potential of implant–bone contact and affect protein adsorption speed. In this work, the effect of sandblasting of the Ti G4 surface on the long-term corrosion resistance in artificial saliva of pH = 7.4 at 37 °C was studied. The X-ray diffraction (XRD) single-{hkl} sin2ψ method was used to measure the sandblasted Ti residual stress. In vitro corrosion resistance tests were conducted for 21 days using the open circuit potential method, polarization curves, and electrochemical impedance spectroscopy. Using the Kelvin scanning probe, the electron work function was determined. Analysis of the obtained results showed an improvement in the corrosion resistance of the sandblasted Ti G4 compared to Ti with the machine surface. The increase in corrosion resistance was related to the residual compressive stress of 324.7 MPa present in the sandblasted Ti surface. Sandblasting caused plastic deformation of the Ti surface, which resulted in the improvement in mechanical properties, as evidenced by the increase in the hardness of the sandblasted Ti compared to Ti with the machine surface.


Materials ◽  
2021 ◽  
Vol 14 (23) ◽  
pp. 7193
Author(s):  
Bosung Seo ◽  
Hyeon-Tae Im ◽  
Ki-Beom Park ◽  
Kwangsuk Park ◽  
Hyung-Ki Park

Microstructures and corrosion properties of pure titanium were characterized when iron was used as a grain refiner. The added Fe element acted as a strong grain refiner for pure titanium by forming β Ti phase at grain boundaries, and 0.15 wt% Fe was revealed to be a sufficient amount to make the grain size of pure titanium below 20 μm, which was the requirement for the desired titanium cathode. However, corrosion resistance was decreased with the Fe amount added. From the open circuit potential (OCP) results, it was obvious that the TiO2 stability against the reducing acid environment was deteriorated with the Fe amount, which seemed to be the main reason for the decreased corrosion resistance. Electrochemical impedance spectroscopy (EIS) results showed that both the decrease in the compact oxide film’s resistance (Rb) and the appearance of the outer porous film occurred as a result of the dissolution of the TiO2 layer, whose phenomena became more apparent as more Fe was added.


2012 ◽  
Vol 23 (2) ◽  
pp. 141-148 ◽  
Author(s):  
Rodrigo Galo ◽  
Ricardo Faria Ribeiro ◽  
Renata Cristina Silveira Rodrigues ◽  
Luís Augusto Rocha ◽  
Maria da Glória Chiarello de Mattos

The aim of this study was to determine the effect of the oral environment on the corrosion of dental alloys with different compositions, using electrochemical methods. The corrosion rates were obtained from the current-potential curves and electrochemical impedance spectroscopy (EIS). The effect of artificial saliva on the corrosion of dental alloys was dependent on alloy composition. Dissolution of the ions occurred in all tested dental alloys and the results were strongly dependent on the general alloy composition. Regarding the alloys containing nickel, the Ni-Cr and Ni-Cr-Ti alloys released 0.62 mg/L of Ni on average, while the Co-Cr dental alloy released ions between 0.01 and 0.03 mg/L of Co and Cr, respectively.The open-circuit potential stabilized at a higher level with lower deviation (standard deviation: Ni-Cr-6Ti = 32 mV/SCE and Co-Cr = 54 mV/SCE). The potenciodynamic curves of the dental alloys showed that the Ni-based dental alloy with >70 wt% of Ni had a similar curve and the Co-Cr dental alloy showed a low current density and hence a high resistance to corrosion compared with the Ni-based dental alloys. Some changes in microstructure were observed and this fact influenced the corrosion behavior for the alloys. The lower corrosion resistance also led to greater release of nickel ions to the medium. The quantity of Co ions released from the Co-Cr-Mo alloy was relatively small in the solutions. In addition, the quantity of Cr ions released into the artificial saliva from the Co-Cr alloy was lower than Cr release from the Ni-based dental alloys.


2010 ◽  
Vol 95 ◽  
pp. 79-83
Author(s):  
Amir Eliezer

Micro-arc oxidization of AM50 magnesium alloys was studied. The influence of micro-arc oxidization process was investigated; phase structure were analyzed using X-ray diffraction (XRD). Open circuit potential (OCP) and electrochemical impedance spectroscopy (EIS) were used to evaluate the corrosion resistance of ceramic coatings formed on magnesium alloys under stress conditions. XRD analyses indicate that the ceramic coatings fabricated on the surface of magnesium alloys by micro-arc oxidization are composed of spinel phase MgAl2O4 The corrosion resistance of ceramic coatings is improved compared with magnesium alloy substrate.


2015 ◽  
Vol 61 (2) ◽  
pp. 117-120
Author(s):  
Costin Coman ◽  
◽  
Raluca Monica Comăneanu ◽  
Violeta Hâncu ◽  
Horia Mihail Barbu ◽  
...  

Objectives. In this study we evaluated corrosion resistance of three types of metal alloys (two NiCr and one CoCr). Methods. Samples (coded A, B, C) of circular shape, with dimensions 13 x 1.5 mm, sanded and polished, were introduced in Fusayama Meyer artificial saliva at pH 5.2 and 37 ± 0.5°C and tested in terms of corrosion resistance with a potentiostat/galvanostat (model 4000 PARSTAT, Princeton Applied Research). Results. Open circuit potential EOC [mV] ranged between 21.316 and 5.75. Corrosion potential Ecor [mV] was between -73.536 and -395.662, and the corrosion current density icor [A/cm2] was between 1.237 x 10-6 and 905.13 x 10-9. Conclusion. The best corrosion behavior in Fusayama Meyer artificial saliva at pH 5.2 and at a temperature of 37 ± 0.5°C is the alloy A, followed by the alloy C.


Coatings ◽  
2019 ◽  
Vol 9 (11) ◽  
pp. 724 ◽  
Author(s):  
Zhang ◽  
Hong ◽  
Lin ◽  
Zheng

The corrosion behavior of unsealed and sealed high-velocity oxygen-fuel (HVOF)-sprayed nanostructured WC-CoCr cermet coatings under different corrosive environments was investigated using scanning electron microscopy (SEM), open circuit potential (OCP), potentiodynamic polarization and electrochemical impedance spectroscopy (EIS). Ultrasonic excitation sealing with aluminum phosphate was performed in an external ultrasonic bath with the frequency of 40 kHz at atmospheric pressure and room temperature. SEM micrographs revealed that the exposed area of the coating was effectively reduced by the coverage of aluminum phosphate sealant on the majority of pores. Electrochemical measurements demonstrated that the sealant with the help of ultrasonic energy could shift the corrosion potential to a more noble direction, reduce the corrosion current density, increase the resistance of charge transfer, and effectively improve the corrosion resistance of the coating in both 3.5 wt % NaCl and 1 mol·L−1 HCl solutions.


2015 ◽  
Vol 2015 ◽  
pp. 1-18 ◽  
Author(s):  
J. Porcayo-Calderon ◽  
R. A. Rodriguez-Diaz ◽  
E. Porcayo-Palafox ◽  
J. Colin ◽  
A. Molina-Ocampo ◽  
...  

The effect of Cu addition on the electrochemical corrosion behavior of Ni3Al intermetallic alloy was investigated by potentiodynamic polarization, open-circuit potential, linear polarization resistance, and electrochemical impedance spectroscopy in 1.0 M H2SO4solution. Performance of the pure elements (Cu, Ni, and Al) was also evaluated. In general, Cu addition improved the corrosion resistance of Ni3Al. Electrochemical measurements show that corrosion resistance of Ni3Al-1Cu alloy is lower than that of other intermetallic alloys and pure elements (Ni, Cu, and Al) in 1.0 M H2SO4solution at 25°C. Surface analysis showed that the Ni3Al alloys are attacked mainly through the dendritic phases, and Cu addition suppresses the density of dendritic phases.


Author(s):  
Mohandoss S ◽  
◽  
Srinivasan S.P. ◽  

Development of biocompatible dental implants has become significant impact in dental industry. In the present work, we report for the development of biocompatible nano Yttria stabilised Zirconia (YSZ) coatings on 316L stainless steel (316L SS) obtained by EPD process. The optimized sample (nano YSZ coating on 316 obtained at applied potential of 70 V for 5 minutes) were sintered in air at 600, 800 and 900°C. The surface morphology and composition of the coatings were characterized by XRD and FE-SEM with EDAX. The electrochemical performance of the uncoated metal and nano YSZ coated 316L SS samples were evaluated in artificial saliva (AS) medium using electrochemical techniques such as Open Circuit Potential – time measurement (OCP), Electrochemical Impedance Spectroscopy (EIS) and Cyclic Potentiodynamic Polarization (CPP).


2019 ◽  
Vol 8 (6) ◽  
pp. 435-440
Author(s):  
Asmaa Marda ◽  
Khadija Mouflih ◽  
Abdelkebir Bellaouchou ◽  
Abdallah Guenbour ◽  
Asmae Elmansari ◽  
...  

This study aimed to compare the resistance of dental alloys to corrosion in a solution containing oral bacteria named Streptococcus mutans (S.mutans). The electrochemical behavior of Nickel-Titanium (NiTi) was investigated in sterile Fusayama artificial saliva (AS) with the enrichment medium tryptic soy broth (TSB) in solution 1 and (AS) with (TSB) and bacteria in solution 2. The electrochemical procedures selected for this work were open circuit potentials (OCP), Potentiodynamic polarization (PDP), and electrochemical impedance spectroscopy (EIS). The NiTi surface was examined using optical microscopy.      After 24 hours of immersion in artificial saliva, the results have shown that NiTi revealed high corrosion reactivity in the presence of S. mutans and present pitting corrosion on the surface.