Microstructure and In Vitro Biodegradable Properties of Fe-Zn Alloys Prepared by Electroforming

2014 ◽  
Vol 1033-1034 ◽  
pp. 1200-1206 ◽  
Author(s):  
Wei Qiang Wang ◽  
Juan Wang ◽  
Min Qi

New biodegradable Fe-Zn alloys with different concentration of zinc were prepared by electroforming in this paper. The composition, phase and microstructure of the Fe-Zn alloys were investigated by EDX, XRD and SEM, respectively. The potentiodynamic polarization and static immersion test were used to evaluate the in vitro biodegradation properties of these alloys. The results revealed that the alloys consist of single-phase Fe-Zn solid solution and have a better degradation property than pure iron, which make it a potential material used for bioabsorbable endovascular stent.

Coatings ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 667
Author(s):  
Zexin Wang ◽  
Fei Ye ◽  
Liangyu Chen ◽  
Weigang Lv ◽  
Zhengyi Zhang ◽  
...  

In this work, ZK60 magnesium alloy was employed as a substrate material to produce ceramic coatings, containing Ca and P, by micro-arc oxidation (MAO). Atmospheric plasma spraying (APS) was used to prepare the hydroxyapatite layer (HA) on the MAO coating to obtain a composite coating for better biological activity. The coatings were examined by various means including an X-ray diffractometer, a scanning electron microscope and an energy spectrometer. Meanwhile, an electrochemical examination, immersion test and tensile test were used to evaluate the in vitro performance of the composite coatings. The results showed that the composite coating has a better corrosion resistance. In addition, this work proposed a degradation model of the composite coating in the simulated body fluid immersion test. This model explains the degradation process of the MAO/APS coating in SBF.


Author(s):  
Vinay Kumar Soni ◽  
S Sanyal ◽  
K Raja Rao ◽  
Sudip K Sinha

The formation of single phase solid solution in High Entropy Alloys (HEAs) is essential for the properties of the alloys therefore, numerous approach were proposed by many researchers to predict the stability of single phase solid solution in High Entropy Alloy. The present review examines some of the recent developments while using computational intelligence techniques such as parametric approach, CALPHAD, Machine Learning etc. for prediction of various phase formation in multicomponent high entropy alloys. A detail study of this data-driven approaches pertaining to the understanding of structural and phase formation behaviour of a new class of compositionally complex alloys is done in the present investigation. The advantages and drawbacks of the various computational are also discussed. Finally, this review aims at understanding several computational modeling tools complying the thermodynamic criteria for phase formation of novel HEAs which could possibly deliver superior mechanical properties keeping an aim at advanced engineering applications.


2018 ◽  
Vol 941 ◽  
pp. 1137-1142
Author(s):  
Elena Colombini ◽  
Andrea Garzoni ◽  
Roberto Giovanardi ◽  
Paolo Veronesi ◽  
Angelo Casagrande

The equimolar Cr, Mn, Fe, Co and Ni alloy, first produced in 2004, was unexpectedly found to be single-phase. Consequently, a new concept of materials was developed: high entropy alloys (HEA) forming a single solid-solution with a near equiatomic composition of the constituting elements. In this study, an equimolar CoCrFeMnNi HEA was modified by the addition of 5 at% of either Al, Cu or Zr. The cold-rolled alloys were annealed for 30 minutes at high temperature to investigate the recrystallization kinetics. The evolution of the grain boundary and the grain size were investigated, from the as-cast to the recrystallized state. Results show that the recrystallized single phase FCC structures exhibits different twin grains density, grain size and recrystallization temperatures as a function of the at.% of modifier alloying elements added. In comparison to the equimolar CoCrFeMnNi, the addition of modifier elements increases significantly the recrystallization temperature after cold deformation. The sluggish diffusion (typical of HEA alloys), the presence of a solute in solid solution as well as the low twin boundary energy are responsible for the lower driving force for recrystallization.


2006 ◽  
Vol 15-17 ◽  
pp. 113-118 ◽  
Author(s):  
Hendra Hermawan ◽  
Maryam Moravej ◽  
Dominique Dubé ◽  
Michel Fiset ◽  
D. Mantovani

The short-term need of scaffolding function of stent and the prevention of potential longterm complication of permanently implanted stent have directed to the original idea of biodegradable stent. Selecting and developing materials showing appropriate mechanical and degradation properties are key steps for the development of this new class of medical devices. Therefore, the study of their in vitro degradation behaviour is mandatory for the selection of potential candidate materials suited in vivo. In this work, the degradation behaviour of current studied biodegradable metals including three magnesium alloys (Mg, AM60B and AZ91D), pure iron and Fe-35Mn was investigated. The tests were performed in a simulated blood plasma solution at 37±0.1 oC, using three different methods; potentiodynamic polarization, static immersion, and dynamic test in a test-bench which mimics the flow condition in human coronary artery. Degradation rate was determined as ion release rate measured by using atomic adsorption spectroscopy (AAS) and also estimated from weight loss and corrosion current. Surface morphology and chemical composition of corroded specimens were analyzed by using SEM/EDS. The three degradation methods provide consistent results in corrosion tendency, where Mg showed the highest corrosion rate followed by AZ91D, AM60B, Fe-35Mn and iron. Potentiodynamic polarization gives a rapid estimation of corrosion behaviour and rate. Static immersion test shows the effect of time on the degradation rate and behaviour. Dynamic test provides the closest approach to the environment after stent implantation and its results show the effect of the flow on the materials degradation. In conclusion, the three investigated methods can be applied for screening, selecting and validating materials for degradable stent application before going further to in vivo assessments.


Materials ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 566
Author(s):  
Pham Hong Quan ◽  
Iulian Antoniac ◽  
Florin Miculescu ◽  
Aurora Antoniac ◽  
Veronica Manescu (Păltânea) ◽  
...  

Fluoride conversion coatings on Mg present many advantages, among which one can find the reduction of the corrosion rate under “in vivo” or “in vitro” conditions and the promotion of the calcium phosphate deposition. Moreover, the fluoride ions released from MgF2 do not present cytotoxic effects and inhibit the biofilm formation, and thus these treated alloys are very suitable for cardiovascular stents and biodegradable orthopedic implants. In this paper, the biodegradation behavior of four new magnesium biodegradable alloys that have been developed in the laboratory conditions, before and after surface modifications by fluoride conversion (and sandblasting) coatings, are analyzed. We performed structural and surface analysis (XRD, SEM, contact angle) before and after applying different surface treatments. Furthermore, we studied the electrochemical behavior and biodegradation of all experimental samples after immersion test performed in NaCl solution. For a better evaluation, we also used LM and SEM for evaluation of the corroded samples after immersion test. The results showed an improved corrosion resistance for HF treated alloy in the NaCl solution. The chemical composition, uniformity, thickness and stability of the layers generated on the surface of the alloys significantly influence their corrosion behavior. Our study reveals that HF treatment is a beneficial way to improve the biofunctional properties required for the studied magnesium alloys to be used as biomaterials for manufacturing the orthopedic implants.


Sign in / Sign up

Export Citation Format

Share Document