Historic Buildings: Long Term Stability Evaluation Using Wireless Sensor Networks

2010 ◽  
Vol 133-134 ◽  
pp. 235-240 ◽  
Author(s):  
Hua Yong Wu ◽  
Daniele Zonta ◽  
Matteo Pozzi ◽  
Paolo Zanon ◽  
Michele Corrà

An automatic diagnostic monitoring system can guarantee the safety and integrity of a historic building. In this paper, we describe the long term application of a wireless sensor network (WSN) for permanent health monitoring in the Torre Aquila, a historic tower in Trento, Italy. The system consists of accelerometers, thermometers and fiber optic sensors (FOS) with customized wireless modules and dedicated software designed for wireless communication. The whole system was completed and started operation in September 2008, and data from the various sensor nodes are collected continuously, save during periods of system maintenance and update. Based on the first 1.5 years of operation in assessing the stability of the tower, the WSN is seen to be an effective tool. Modal analysis indicates that the tower has two independent structural parts. A comparison between the acquired long term deformation measurements and simulated numerical results shows good agreement. Monitoring of ambient vibration suggests that such vibration is not now a source of concern for the stability of the tower.

1979 ◽  
Vol 42 (04) ◽  
pp. 1135-1140 ◽  
Author(s):  
G I C Ingram

SummaryThe International Reference Preparation of human brain thromboplastin coded 67/40 has been thought to show evidence of instability. The evidence is discussed and is not thought to be strong; but it is suggested that it would be wise to replace 67/40 with a new preparation of human brain, both for this reason and because 67/40 is in a form (like Thrombotest) in which few workers seem to use human brain. A �plain� preparation would be more appropriate; and a freeze-dried sample of BCT is recommended as the successor preparation. The opportunity should be taken also to replace the corresponding ox and rabbit preparations. In the collaborative study which would be required it would then be desirable to test in parallel the three old and the three new preparations. The relative sensitivities of the old preparations could be compared with those found in earlier studies to obtain further evidence on the stability of 67/40; if stability were confirmed, the new preparations should be calibrated against it, but if not, the new human material should receive a calibration constant of 1.0 and the new ox and rabbit materials calibrated against that.The types of evidence available for monitoring the long-term stability of a thromboplastin are discussed.


2014 ◽  
Vol 7 (11) ◽  
pp. 3783-3799 ◽  
Author(s):  
A. T. J. de Laat ◽  
I. Aben ◽  
M. Deeter ◽  
P. Nédélec ◽  
H. Eskes ◽  
...  

Abstract. Validation results from a comparison between Measurement Of Pollution In The Troposphere (MOPITT) V5 Near InfraRed (NIR) carbon monoxide (CO) total column measurements and Measurement of Ozone and Water Vapour on Airbus in-service Aircraft (MOZAIC)/In-Service Aircraft for a Global Observing System (IAGOS) aircraft measurements are presented. A good agreement is found between MOPITT and MOZAIC/IAGOS measurements, consistent with results from earlier studies using different validation data and despite large variability in MOPITT CO total columns along the spatial footprint of the MOZAIC/IAGOS measurements. Validation results improve when taking the large spatial footprint of the MOZAIC/IAGOS data into account. No statistically significant drift was detected in the validation results over the period 2002–2010 at global, continental and local (airport) scales. Furthermore, for those situations where MOZAIC/IAGOS measurements differed from the MOPITT a priori, the MOPITT measurements clearly outperformed the MOPITT a priori data, indicating that MOPITT NIR retrievals add value to the MOPITT a priori. Results from a high spatial resolution simulation of the chemistry-transport model MOCAGE (MOdèle de Chimie Atmosphérique à Grande Echelle) showed that the most likely explanation for the large MOPITT variability along the MOZAIC-IAGOS profile flight path is related to spatio-temporal CO variability, which should be kept in mind when using MOZAIC/IAGOS profile measurements for validating satellite nadir observations.


2021 ◽  
Vol 15 (1) ◽  
pp. 2
Author(s):  
Cristina Martín-Sabroso ◽  
Mario Alonso-González ◽  
Ana Fernández-Carballido ◽  
Juan Aparicio-Blanco ◽  
Damián Córdoba-Díaz ◽  
...  

Accumulation of cystine crystals in the cornea of patients suffering from cystinosis is considered pathognomonic and can lead to severe ocular complications. Cysteamine eye drop compounded formulations, commonly prepared by hospital pharmacy services, are meant to diminish the build-up of corneal cystine crystals. The objective of this work was to analyze whether the shelf life proposed for six formulations prepared following different protocols used in hospital pharmacies is adequate to guarantee the quality and efficacy of cysteamine eye drops. The long-term and in-use stabilities of these preparations were studied using different parameters: content of cysteamine and its main degradation product cystamine; appearance, color and odor; pH and viscosity; and microbiological analysis. The results obtained show that degradation of cysteamine was between 20% and 50% after one month of storage in the long-term stability study and between 35% and 60% in the in-use study. These data confirm that cysteamine is a very unstable molecule in aqueous solution, the presence of oxygen being the main degradation factor. Saturation with nitrogen gas of the solutions offers a means of reducing cysteamine degradation. Overall, all the formulae studied presented high instability at the end of their shelf life, suggesting that their clinical efficacy might be dramatically compromised.


2019 ◽  
Vol 65 (1) ◽  
pp. 23-31
Author(s):  
Alexandr Mikyška ◽  
Marie Jurková

This article presents the results of the harvest forecast of the alpha- and beta-bitter acids of the Czech hop varieties in the 2018 harvest, the results are discussed in relation to the long-term averages, the composition of the bitter acid analogs and the stability of the varietal characteristics. 180 hop samples were analyzed using EBC 7.7 (HPLC) method. The alpha-acid content of the most important Saaz variety (2.9% in dry matter) was identical to the 2017 harvest and 18% rel. lower than the 26-year average. The alpha-acid content of Sladek (5.0%), Premiant (4.8%), and Saaz Late (1.6%) varieties was significantly lower than the long-term average. The harvest of the hops of the Kazbek and Agnus varieties was close to the long-term average. The ratio of alpha- and beta-acids, the relative content of cohumulone and the relative content of colupulone were consistent with long-term averages for the tested varieties. It was confirmed, that the harvest forecast gives timely information on the alpha-acids content of the harvest, the results were in good agreement with the values of the final evaluation of all harvested hops samples.


2013 ◽  
Vol 23 (11) ◽  
pp. 2129-2154 ◽  
Author(s):  
HÉLÈNE BARUCQ ◽  
JULIEN DIAZ ◽  
VÉRONIQUE DUPRAT

This work deals with the stability analysis of a one-parameter family of Absorbing Boundary Conditions (ABC) that have been derived for the acoustic wave equation. We tackle the problem of long-term stability of the wave field both at the continuous and the numerical levels. We first define a function of energy and show that it is decreasing in time. Its discrete form is also decreasing under a Courant–Friedrichs–Lewy (CFL) condition that does not depend on the ABC. Moreover, the decay rate of the continuous energy can be determined: it is exponential if the computational domain is star-shaped and this property can be illustrated numerically.


2021 ◽  
pp. 1-27
Author(s):  
Yichen Bao ◽  
Kai Liu ◽  
Quan Zheng ◽  
Lulu Yao ◽  
Yufu Xu

Abstract Pickering emulsion is a new type of stable emulsion made by ultra-fine solid particles instead of traditional surfactants as stabilizers, which has received widespread attention in recent years. The preparation methods of stator-rotor homogenization, high-pressure homogenization, and ultrasonic emulsification were compared with others in this work. The main factors affecting the stability of Pickering emulsion are the surface humidity of the solid particles, the polarity of the oil phase, and the oil-water ratio. These factors could affect the nature of the solid particles, the preparation process of Pickering emulsion and the external environment. Consequently, the long-term stability of Pickering emulsion is still a challenge. The tribological investigations of Pickering emulsion were summarized, and the multifunctional Pickering emulsion shows superior prospects for tribological applications. Moreover, the latest development of Pickering emulsion offers a new strategy for smart lubrication in the near future.


2012 ◽  
Vol 2012 (CICMT) ◽  
pp. 000371-000376 ◽  
Author(s):  
Marina Santo Zarnik ◽  
Darko Belavic

This paper discusses the stability of a piezoresistive, LTCC-based, pressure sensor that was designed for measurements in a low-pressure range below 100 mbar. The intrinsic stability of the sensor's offset was evaluated at a constant ambient temperature and different conditions regarding the atmospheric humidity. The sensors were also subjected to functional fatigue tests, which included a full-scale and an overload pressure cycling. The results of the fatigue testing revealed the vulnerability of the sensor's structure from the point of view of the long-term stability and the life-cycle. Nevertheless, the stability of the key characteristics of the prototype sensors was found to be satisfactory for accurate measurements in the low-pressure ranges.


1995 ◽  
Vol 377 ◽  
Author(s):  
Mohan K. Bhan

ABSTRACTWe have systematically investigated the effects of addition of sub-ppm levels of boron on the stability of a-Si:H films and p-i-n devices, deposited by PE-CVD technique. The films thus produced with appropriate amounts of boron, show a significant improvement in stability, when soaked under both AM 1.5 (short-term) as well as 10×sun (long-term) illumination conditions. The opto-electronic properties of the films are quite respectable It is concluded that boron compensates the native impurities by forming donor-acceptor pairs, which reduces the “fast” defects and hence the initial degradation of the films. It is also speculated that boron may also be improving the short-term stability, by reducing the recombination of light generated electrons and holes, by converting D° into D+ states. The long-term stability appears to get affected by hydrogen dilution which seems to reduce the amount of “slow” defects. As a result of B doping of i-layer, the initial conversion efficiency of the devices decreases. It is presumed that our devices may contain an enhanced level of boron impurity, than expected, making them as worse material and to degrade less.


2016 ◽  
Vol 21 (1) ◽  
pp. 67-74 ◽  
Author(s):  
Caroline Andrade Rocha ◽  
Renato Rodrigues de Almeida ◽  
José Fernando Castanha Henriques ◽  
Carlos Flores-Mir ◽  
Marcio Rodrigues de Almeida

Objective: To evaluate the stability of mesiodistal inclination of maxillary molars produced by a pendulum appliance, five years after completion of orthodontic treatment. Angulation changes were compared to an untreated sample. Methods: The sample consisted of 20 patients (14 females and 6 males) with Class II, Division 1 malocclusion that was treated through molar distalization with a pendulum appliance followed by cervical headgear and full fixed appliances. Maxillary molar inclination was evaluated through panoramic radiograph. The mean age at pretreatment was 14.3 ± 1.6 years, whereas at immediate post-treatment it was 18.6 ± 1.8 years, and at long-term post-treatment it was 23.8 ± 2.0 years. A control group of 16 untreated individuals with untreated normocclusion ranging in age from 12 to 17 years old were used as comparison group. Data were statistically analyzed with independent t-tests and ANOVA test followed by Tukey post-hoc tests. Results: Statistically significant differences were found between T1 (94.50) and T2 (98.80) as well as between T2 and T3 (94.70) for maxillary first molars. Maxillary second molars did not show any statistically significant positional changes during the evaluated time periods T1 (107.50), T2 (109.30) and T3 (106.90). Conclusion: Although maxillary first molars underwent distal crown inclination immediately after treatment, approximately five years thereafter their roots tended to upright close to the pretreatment positions.


2018 ◽  
Vol 3 (3) ◽  
pp. 143-151
Author(s):  
Sophie Huvelle ◽  
Marie Godet ◽  
Laurence Galanti ◽  
Mélanie Closset ◽  
Benoît Bihin ◽  
...  

AbstractBackgroundPiperacillin-Tazobactam is frequently infused in hospitals. The use of a generic version was considered after the out of stock of the brand name Tazocin®. The stability of 4 g of Tazocin®in 120 mL of dextrose 5 % (D5) was demonstrated during 35 days at 5 °C ± 3 °C after freezing (−20 °C) and microwave thawing (FMT). The aim of the study was to investigate and compare the long-term stability of Tazocin®and a generic product in the same conditions.MethodsFive polyolefin bags of 4 g of Piperacillin/Tazobactam®Sandoz and 5 bags of 4 g of Tazocin®were prepared under aseptic conditions in 120 mL of D5 and stored 3 months at 20 °C then thawed and stored 58 days at 5 ± 3 °C.Spectrophotometric absorbance at different wavelengths, pH measurement, visual and microscopic observations were also performed.The concentrations were measured by HPLC, at 211 nm for tazobactam and 230 nm for piperacilline.ResultsNo significant change in pH values or optic densities, no crystals were detected. The lower confidence limit at 95 % of the concentration for the solutions remains superior to 90 % of the initial concentration until 58 days of storage at 5 ± 3 °C.ConclusionUnder these conditions, 4 g/120 mL of Piperacillin/Tazobactam®Sandoz or Tazocin®in D5 infusion in polyolefin bags remains stable at least for 58 days at 5 ± 3 °C after FMT


Sign in / Sign up

Export Citation Format

Share Document