Ionic Polymeric Conductor Nano Composites (IPCNCs) as Distributed Nanosensors and Nanoactuators

2008 ◽  
Vol 54 ◽  
pp. 70-81 ◽  
Author(s):  
Mohsen Shahinpoor

This article covers advances made in connection with Ionic Polymeric-Conductor Nano Composites (IPCNCs) as distributed biomimetic nanosensors, nanoactuators, nanorobots and artificial muscles. A review of the fundamental properties and characteristics of IPCNCs will first be presented. This summary will include descriptions of the basic materials' molecular structure and subsequent procedure to manufacture the basic material for chemical plating and electroactivation. Further described are chemical molecular plating technologies to make IPCNCs, nanotechnologies of manufacturing and trapping of nanoparticles, SEM, TEM, SPM and AFM characterization of IPMNCs, biomimetic sensing and actuation characterization techniques, electrical characterization and equivalent circuit modeling of IPCNCs as electronic materials. A phenomenological model of the underlying sensing and actuation mechanisms is also presented based on linear irreversible thermodynamics with two driving forces, an electric field and a solvent pressure gradient and two fluxes, electric current density and the ionic+solvent flux. The presentation concludes with a number of videos and some live demos.

2012 ◽  
Vol 42 (4) ◽  
pp. 223-227
Author(s):  
Jae-Hong Roh ◽  
Yil-Hwan You ◽  
Jae-Pyeong Ahn ◽  
Jinha Hwang

Author(s):  
S.F. Corcoran

Over the past decade secondary ion mass spectrometry (SIMS) has played an increasingly important role in the characterization of electronic materials and devices. The ability of SIMS to provide part per million detection sensitivity for most elements while maintaining excellent depth resolution has made this technique indispensable in the semiconductor industry. Today SIMS is used extensively in the characterization of dopant profiles, thin film analysis, and trace analysis in bulk materials. The SIMS technique also lends itself to 2-D and 3-D imaging via either the use of stigmatic ion optics or small diameter primary beams.By far the most common application of SIMS is the determination of the depth distribution of dopants (B, As, P) intentionally introduced into semiconductor materials via ion implantation or epitaxial growth. Such measurements are critical since the dopant concentration and depth distribution can seriously affect the performance of a semiconductor device. In a typical depth profile analysis, keV ion sputtering is used to remove successive layers the sample.


1981 ◽  
Vol 4 ◽  
Author(s):  
T. J. Stultz ◽  
J. F. Gibbons

ABSTRACTStructural and electrical characterization of laser recrystallized LPCVD silicon films on amorphous substrates using a shaped cw laser beam have been performed. In comparing the results to data obtained using a circular beam, it was found that a significant increase in grain size can be achieved and that the surface morphology of the shaped beam recrystallized material was much smoother. It was also found that whereas circular beam recrystallized material has a random grain structure, shaped beam material is highly oriented with a <100> texture. Finally the electrical characteristics of the recrystallized film were very good when measured in directions parallel to the grain boundaries.


2011 ◽  
Vol E94-C (2) ◽  
pp. 157-163 ◽  
Author(s):  
Masakazu MUROYAMA ◽  
Ayako TAJIRI ◽  
Kyoko ICHIDA ◽  
Seiji YOKOKURA ◽  
Kuniaki TANAKA ◽  
...  

Author(s):  
E. Hendarto ◽  
S.L. Toh ◽  
J. Sudijono ◽  
P.K. Tan ◽  
H. Tan ◽  
...  

Abstract The scanning electron microscope (SEM) based nanoprobing technique has established itself as an indispensable failure analysis (FA) technique as technology nodes continue to shrink according to Moore's Law. Although it has its share of disadvantages, SEM-based nanoprobing is often preferred because of its advantages over other FA techniques such as focused ion beam in fault isolation. This paper presents the effectiveness of the nanoprobing technique in isolating nanoscale defects in three different cases in sub-100 nm devices: soft-fail defect caused by asymmetrical nickel silicide (NiSi) formation, hard-fail defect caused by abnormal NiSi formation leading to contact-poly short, and isolation of resistive contact in a large electrical test structure. Results suggest that the SEM based nanoprobing technique is particularly useful in identifying causes of soft-fails and plays a very important role in investigating the cause of hard-fails and improving device yield.


Author(s):  
Randal Mulder ◽  
Sam Subramanian ◽  
Tony Chrastecky

Abstract The use of atomic force probe (AFP) analysis in the analysis of semiconductor devices is expanding from its initial purpose of solely characterizing CMOS transistors at the contact level with a parametric analyzer. Other uses found for the AFP include the full electrical characterization of failing SRAM bit cells, current contrast imaging of SOI transistors, measuring surface roughness, the probing of metallization layers to measure leakages, and use with other tools, such as light emission, to quickly localize and identify defects in logic circuits. This paper presents several case studies in regards to these activities and their results. These case studies demonstrate the versatility of the AFP. The needs and demands of the failure analysis environment have quickly expanded its use. These expanded capabilities make the AFP more valuable for the failure analysis community.


Author(s):  
Yuk L. Tsang ◽  
Alex VanVianen ◽  
Xiang D. Wang ◽  
N. David Theodore

Abstract In this paper, we report a device model that has successfully described the characteristics of an anomalous CMOS NFET and led to the identification of a non-visual defect. The model was based on detailed electrical characterization of a transistor exhibiting a threshold voltage (Vt) of about 120mv lower than normal and also exhibiting source to drain leakage. Using a simple graphical simulation, we predicted that the anomalous device was a transistor in parallel with a resistor. It was proposed that the resistor was due to a counter doping defect. This was confirmed using Scanning Capacitance Microscopy (SCM). The dopant defect was shown by TEM imaging to be caused by a crystalline silicon dislocation.