scholarly journals A Novel Low-Energy Ventilative Cooling System for Sustainable Built Environment

A numerical investigation into determining the thermal and ventilation capability of wind towers integrated with the heat pipe technology was carried out in this work. The water-charged copper heat pipes were systematically arranged in a horizontal orientation and integrated inside a modern roof-mounted wind tower. Water was used as the working fluid instead of synthetic refrigerants in order to make the system carbon-neutral alongside maintaining the indoor air quality of the built environment. The three-dimensional Reynolds-Averaged Navier-Stokes (RANS) equations along with the momentum, continuity and energy equations were solved using the commercial Computational Fluid Dynamics (CFD) ANSYS code for velocity and pressure field simulations. Using the inlet wind speeds ranging from 1m/s to 5m/s, the results of the study showed that the proposed cooling system was capable of meeting the regulatory fresh air intake requirements per occupant of 10L/s. In addition, the findings determined that a passive cooling capacity of up to 11K was achievable when the system was subjected to inlet temperatures of 310K or 37°C. The work characterised the sustainable operation of wind tower in delivering energy-free ventilative cooling in regions encompassing hot and dry climatic conditions. The technology presented in this work is currently under an Intellectual Property (IP) protection (GB1321709.6).

2000 ◽  
Author(s):  
M. Singh ◽  
P. K. Panigrahi ◽  
G. Biswas

Abstract A numerical study of rib augmented cooling of turbine blades is reported in this paper. The time-dependent velocity field around a pair of symmetrically placed ribs on the walls of a three-dimensional rectangular channel was studied by use of a modified version of Marker-And-Cell algorithm to solve the unsteady incompressible Navier-Stokes and energy equations. The flow structures are presented with the help of instantaneous velocity vector and vorticity fields, FFT and time averaged and rms values of components of velocity. The spanwise averaged Nusselt number is found to increase at the locations of reattachment. The numerical results are compared with available numerical and experimental results. The presence of ribs leads to complex flow fields with regions of flow separation before and after the ribs. Each interruption in the flow field due to the surface mounted rib enables the velocity distribution to be more homogeneous and a new boundary layer starts developing downstream of the rib. The heat transfer is primarily enhanced due to the decrease in the thermal resistance owing to the thinner boundary layers on the interrupted surfaces. Another reason for heat transfer enhancement can be attributed to the mixing induced by large-scale structures present downstream of the separation point.


Author(s):  
Patrick Moriarty ◽  
Tetsuya Kogaki

Recent measurements from operating wind farms demonstrate that the layout of the farm and interactions between turbine wakes strongly affects the overall efficiency of the wind farm. In some wind farms arranged in rectangular layouts, winds coming from the direction of the rectangular corner create a potential acceleration around the wind farm. This acceleration inherently leads to stronger local wind speeds at wind turbines downstream of the corner turbine, thereby increasing the power output of the downstream turbines. In this study, computational models are developed to predict this complex behavior seen in wind farms. The model used to examine these effects is a fully three-dimensional unsteady incompressible Navier-Stokes code, with the turbulence model turned off. Preliminary results show an optimum spacing configuration is possible. However, the results have yet to be verified at higher Reynolds number, which will be the effort of future work. Ultimately, these tools may lead to more optimal wind farm layouts.


2018 ◽  
Vol 70 ◽  
pp. 03012 ◽  
Author(s):  
Roman Radchenko ◽  
Andrii Radchenko ◽  
Serhiy Serbin ◽  
Serhiy Kantor ◽  
Bohdan Portnoi

Two-stage Gas turbine unite (GTU) inlet air cooling by absorption lithium-bromide chiller (ACh) to the temperature 15 °C and by refrigerant ejector chiller (ECh) to 10 °C through utilizing the turbine exhaust gas heat for changeable ambient air temperatures and corresponding heat loads on the air coolers for the south Ukraine climatic conditions is analysed. An excessive refrigeration capacity of combined absorption-ejector chiller (AECh) exceeding the current heat loads and generated at decreased heat loads on the air coolers at the inlet of GTU can be used for covering increased heat loads to reduce the refrigeration capacity of AECh. The GTU inlet air cooling system with an ambient air precooling booster stage and a base two-stage cooling air to the temperature 10 °C by AECh is proposed. The AECh excessive cooling capacity generated during decreased heat loads on the GTU inlet air coolers is conserved in the thermal accumulator and used for GTU inlet air precooling in a booster stage of air cooler during increased heat loads. There is AECh cooling capacity reduction by 50% due to the use of a booster stage for precooling GTU inlet ambient air at the expense of an excessive cooling capacity accumulated in the thermal storage.


2020 ◽  
Vol 307 ◽  
pp. 01051
Author(s):  
Soumaïla TIGAMPO ◽  
Vincent SAMBOU ◽  
Younouss DIEYE ◽  
Pape Moussa TOURE ◽  
Séckou BODIAN

Sun drying is the oldest way to preserve but also to valorize and store surplus agricultural production. Nowadays, several types of dryers have been developed, but the solar greenhouse dryer is an ideal solution in our tropical countries because of its implicit and higher load capacity. The greenhouse climate depends on several factors, namely the outdoor climatic conditions (air temperature, wind speed, radiation, etc.) but also on the type of materials used to cover the greenhouse. The study was carried out on a parabolic greenhouse covered by a polyethylene film with a concrete base (absorber) which in turn is placed on the ground and will be tested under the climatic conditions of Dakar, Senegal. It is in this context of sustainable development that this work is carried out. The goal is to determine the distribution of temperatures and wind speeds in the greenhouse. The simulation was carried out using the three-dimensional computer fluid dynamics software (CFD). The turbulence method (k-ε) was used and to solve the radiation transfer equation (RTE) we introduce the discrete ordered method DO. We also add the “Solar Load Model” which gives the position of the sun and its radiations in relation to the layout of the greenhouse according to the date and time of the simulation. The simulation is carried out in a closed greenhouse and the results found can be used to improve the design and control of the greenhouse climate. Air temperatures and velocities simulation give an average of 325.95 K and 0.114 m/s respectively.


Energies ◽  
2020 ◽  
Vol 13 (22) ◽  
pp. 5931
Author(s):  
M.T. Nitsas ◽  
E.G. Papoutsis ◽  
I.P. Koronaki

Heat-driven coolers provide a reliable and environmentally benign alternative to traditional electrically powered chillers. Their main advantage is that they can be driven using low enthalpy heat sources. A solar system is installed at the school of Mechanical Engineering of National Technical University of Athens in order to examine the potential of thermal storage and solar cooling under Athens climatic conditions. The cooling effect is produced using a dual bed, single stage, zeolite/water adsorption chiller with cooling capacity of 10 kW at its nominal conditions of operation. Both vacuum tube collectors and hybrid photovoltaic thermal collectors are installed in order to supply the system with heat. The system is evaluated in terms of solar collectors’ useful energy production, heat stored in the intermediate buffer and cooling system’s performance. It is observed that the cooling system operates satisfactorily under Athens climatic conditions achieving a maximum cooling capacity of 3.7 kW and an average COP around 0.5.


1999 ◽  
Vol 121 (1) ◽  
pp. 50-56 ◽  
Author(s):  
I. Sezai ◽  
A. A. Mohamad

The flow and heat transfer characteristics of impinging laminar jets issuing from rectangular slots of different aspect ratios have been investigated numerically through the solution of three-dimensional Navier-Stokes and energy equations in steady state. The three-dimensional simulation reveals the existence of pronounced streamwise velocity off-center peaks near the impingement plate. Furthermore, the effect of these off-center velocity peaks on the Nusselt number distribution is also investigated. Interesting three-dimensional flow structures are detected which cannot be predicted by two-dimensional simulations.


Author(s):  
S Lee ◽  
C Bai ◽  
J Shim

R410A is one of the HFC refrigerants, which are preferred globally to promote the most environmentally friendly option on the basis of an objective reference system taking into account the alternative selection of HCFC refrigerants for the air-conditioning system by the Kyoto protocol. This article presents a three-dimensional (3D) rotary compressor that is within the family of rotary compressors. First, the geometry of the compressor is explained and equations relating the volume of the compression and suction chambers to the rotational angle of the shaft are derived. These equations are used within a model that predicts the mass flow rate, power consumption, and cooling capacity of the compressor. The model includes energy and mass balances within the compression chambers, as well as the estimation of leakage, frictional, and electrical losses. The primary sources of energy and flow losses are identified for this type of compressor. The results presented were generated using refrigerant R410A as the working fluid based on the properties of the ‘Ref-prop 7.0’ program provided by NIST. Due to the two compression chambers vertically separated in one cylinder, this 3D rotary compressor has the best vibration characteristic and the smallest torque variation among the conventional-type compressors.


2021 ◽  
Vol 15 (3) ◽  
pp. 8440-8449
Author(s):  
Sarallah Abbasi ◽  
Maryam Alizadeh

This study investigated a three-dimensional flow analysis on a two-stage contra-rotating axial compressor using the Navier–Stokes, continuity, and energy equations with Ansys CFX commercial software. In order to validate the obtained results, the absolute and relative flow angles curves for each rotor in radial direction were extracted and compared with the other investigation results, indicating good agreement. The compressor efficiency curve also was extracted by varying the compressor pressure ratio and compressor efficiency against mass flow rate. The flow results revealed that further distortion of the flow structure in the second rotor imposed a greater increase in the amount of entropy, especially at near-stall conditions. The increase of entropy in the second rotor is due to the interference of the tip leakage flow with the main flow which consequently caused more drops in the second rotor, suggesting that more efficacy of flow control methods occurred in the second rotor than in the first rotor.


Author(s):  
R. S. Amano

The objective of the present study is to investigate the steam flow behavior through the high-pressure turbine bypass valve. Efforts have mainly been directed at investigating the process of steam flow and property variations aforementioned bypass valve as well as to obtain correlations between the flow rate and the valve opening ratio. Modeling of the high-pressure turbulent steam flow was performed on a three-dimensional non-staggered (co-located) grid system by employing the finite volume method and by solving the three-dimensional, turbulent, compressible Navier-Stokes, and energy equations. Through this research, numerous data have been acquired and analyzed. These efforts enable us to obtain a correlation data set for the flow rate coefficient as a function of valve opening. One of the significant accomplishments is to use the model presented here for further improve a design of a turbine bypass flow valve.


Energies ◽  
2020 ◽  
Vol 13 (23) ◽  
pp. 6201
Author(s):  
Andrii Radchenko ◽  
Eugeniy Trushliakov ◽  
Krzysztof Kosowski ◽  
Dariusz Mikielewicz ◽  
Mykola Radchenko

The efficiency of cooling ambient air at the inlet of gas turbines in temperate climatic conditions was analyzed and reserves for its enhancing through deep cooling were revealed. A method of logical analysis of the actual operation efficiency of turbine intake air cooling systems in real varying environment, supplemented by the simplest numerical simulation was used to synthesize new solutions. As a result, a novel trend in engine intake air cooling to 7 or 10 °C in temperate climatic conditions by two-stage cooling in chillers of combined type, providing an annual fuel saving of practically 50%, surpasses its value gained due to traditional air cooling to about 15 °C in absorption lithium-bromide chiller of a simple cycle, and is proposed. On analyzing the actual efficiency of turbine intake air cooling system, the current changes in thermal loads on the system in response to varying ambient air parameters were taken into account and annual fuel reduction was considered to be a primary criterion, as an example. The improved methodology of the engine intake air cooling system designing based on the annual effect due to cooling was developed. It involves determining the optimal value of cooling capacity, providing the minimum system sizes at maximum rate of annual effect increment, and its rational value, providing a close to maximum annual effect without system oversizing at the second maximum rate of annual effect increment within the range beyond the first maximum rate. The rational value of design cooling capacity provides practically the maximum annual fuel saving but with the sizes of cooling systems reduced by 15 to 20% due to the correspondingly reduced design cooling capacity of the systems as compared with their values defined by traditional designing focused to cover current peaked short-term thermal loads. The optimal value of cooling capacity providing the minimum sizes of cooling system is very reasonable for applying the energy saving technologies, for instance, based on the thermal storage with accumulating excessive (not consumed) cooling capacities at lowered current thermal loads to cover the peak loads. The application of developed methodology enables revealing the thermal potential for enhancing the efficiency of any combustion engine (gas turbines and engines, internal combustion engines, etc.).