On teaching trihedral angle and solid angle

1958 ◽  
Vol 51 (5) ◽  
pp. 358-361
Author(s):  
Howard Fehr

This is the third in a series of articles dealing with angle measures and definitions of angles.

1960 ◽  
Vol 10 ◽  
pp. 716-717 ◽  
Author(s):  
V. I. Krassovsky

The instruments with which we have obtained our results are displayed at the Industrial Exhibition (in Moscow), and therefore I shall not describe them here. I shall state briefly the results of those investigations in the upper atmosphere which are related to the interplanetary medium and are therefore of interest to astronomers.We made an attempt to measure corpuscular fluxes by means of the third sputnik. For this purpose we used as indicators two fluorescent screens made of ZnS (Ag) (2 x i o - 3 g cm-2), covered with aluminium foil of different thicknesses (8 x i o - 4 g cm-2 and 4 x io~4 g cm-2). There were three aluminium diaphragms 5 mm thick in front of screens 5 cm in diameter. Each diaphragm had a window for capturing all corpuscles with a solid angle of 1/4 steradian. The emission of the fluorescent screens was detected by photo-multipliers. The electrical signals so produced were transmitted to a storage device and then to the Earth by a radio-telemetering system.


1978 ◽  
Vol 79 ◽  
pp. 274-275
Author(s):  
M. A. Arakelian

The distribution of Markarian galaxies in annular zones at different angular distances θ (degrees) from the centre of the Coma cluster is shown in the Table. the coordinates of the centre for the equinox 1950 are assumed to be α = 12h57m.5, δ = 28°15′. the third, fourth and fifth columns of the Table contain the number of Markarian galaxies in each zone, the solid angle in square degrees and their mean surface densities respectively. It can be seen that an excess surface density of Markarian galaxies exists not only in the very central zone I but in the annular zone II as well. Indeed, the ratio n/ω in zone II is more than twice the value corresponding to the whole area surveyed (and to zones III and IV).


1967 ◽  
Vol 31 ◽  
pp. 177-179
Author(s):  
W. W. Shane

In the course of several 21-cm observing programmes being carried out by the Leiden Observatory with the 25-meter telescope at Dwingeloo, a fairly complete, though inhomogeneous, survey of the regionl11= 0° to 66° at low galactic latitudes is becoming available. The essential data on this survey are presented in Table 1. Oort (1967) has given a preliminary report on the first and third investigations. The third is discussed briefly by Kerr in his introductory lecture on the galactic centre region (Paper 42). Burton (1966) has published provisional results of the fifth investigation, and I have discussed the sixth in Paper 19. All of the observations listed in the table have been completed, but we plan to extend investigation 3 to a much finer grid of positions.


1966 ◽  
Vol 25 ◽  
pp. 227-229 ◽  
Author(s):  
D. Brouwer

The paper presents a summary of the results obtained by C. J. Cohen and E. C. Hubbard, who established by numerical integration that a resonance relation exists between the orbits of Neptune and Pluto. The problem may be explored further by approximating the motion of Pluto by that of a particle with negligible mass in the three-dimensional (circular) restricted problem. The mass of Pluto and the eccentricity of Neptune's orbit are ignored in this approximation. Significant features of the problem appear to be the presence of two critical arguments and the possibility that the orbit may be related to a periodic orbit of the third kind.


1988 ◽  
Vol 102 ◽  
pp. 79-81
Author(s):  
A. Goldberg ◽  
S.D. Bloom

AbstractClosed expressions for the first, second, and (in some cases) the third moment of atomic transition arrays now exist. Recently a method has been developed for getting to very high moments (up to the 12th and beyond) in cases where a “collective” state-vector (i.e. a state-vector containing the entire electric dipole strength) can be created from each eigenstate in the parent configuration. Both of these approaches give exact results. Herein we describe astatistical(or Monte Carlo) approach which requires onlyonerepresentative state-vector |RV> for the entire parent manifold to get estimates of transition moments of high order. The representation is achieved through the random amplitudes associated with each basis vector making up |RV>. This also gives rise to the dispersion characterizing the method, which has been applied to a system (in the M shell) with≈250,000 lines where we have calculated up to the 5th moment. It turns out that the dispersion in the moments decreases with the size of the manifold, making its application to very big systems statistically advantageous. A discussion of the method and these dispersion characteristics will be presented.


Author(s):  
N. J. Zaluzec

The ultimate sensitivity of microchemical analysis using x-ray emission rests in selecting those experimental conditions which will maximize the measured peak-to-background (P/B) ratio. This paper presents the results of calculations aimed at determining the influence of incident beam energy, detector/specimen geometry and specimen composition on the P/B ratio for ideally thin samples (i.e., the effects of scattering and absorption are considered negligible). As such it is assumed that the complications resulting from system peaks, bremsstrahlung fluorescence, electron tails and specimen contamination have been eliminated and that one needs only to consider the physics of the generation/emission process.The number of characteristic x-ray photons (Ip) emitted from a thin foil of thickness dt into the solid angle dΩ is given by the well-known equation


Author(s):  
S. Kimoto ◽  
H. Hashimoto ◽  
S. Takashima ◽  
R. M. Stern ◽  
T. Ichinokawa

The most well known application of the scanning microscope to the crystals is known as Coates pattern. The contrast of this image depends on the variation of the incident angle of the beam to the crystal surface. The defect in the crystal surface causes to make contrast in normal scanning image with constant incident angle. The intensity variation of the backscattered electrons in the scanning microscopy was calculated for the defect in the crystals by Clarke and Howie. Clarke also observed the defect using a scanning microscope.This paper reports the observation of lattice defects appears in thin crystals through backscattered, secondary and transmitted electron image. As a backscattered electron detector, a p-n junction detector of 0.9 π solid angle has been prepared for JSM-50A. The gain of the detector itself is 1.2 x 104 at 50 kV and the gain of additional AC amplifier using band width 100 Hz ∼ 10 kHz is 106.


Author(s):  
J. R. Michael

X-ray microanalysis in the analytical electron microscope (AEM) refers to a technique by which chemical composition can be determined on spatial scales of less than 10 nm. There are many factors that influence the quality of x-ray microanalysis. The minimum probe size with sufficient current for microanalysis that can be generated determines the ultimate spatial resolution of each individual microanalysis. However, it is also necessary to collect efficiently the x-rays generated. Modern high brightness field emission gun equipped AEMs can now generate probes that are less than 1 nm in diameter with high probe currents. Improving the x-ray collection solid angle of the solid state energy dispersive spectrometer (EDS) results in more efficient collection of x-ray generated by the interaction of the electron probe with the specimen, thus reducing the minimum detectability limit. The combination of decreased interaction volume due to smaller electron probe size and the increased collection efficiency due to larger solid angle of x-ray collection should enhance our ability to study interfacial segregation.


Author(s):  
Huang Min ◽  
P.S. Flora ◽  
C.J. Harland ◽  
J.A. Venables

A cylindrical mirror analyser (CMA) has been built with a parallel recording detection system. It is being used for angular resolved electron spectroscopy (ARES) within a SEM. The CMA has been optimised for imaging applications; the inner cylinder contains a magnetically focused and scanned, 30kV, SEM electron-optical column. The CMA has a large inner radius (50.8mm) and a large collection solid angle (Ω > 1sterad). An energy resolution (ΔE/E) of 1-2% has been achieved. The design and performance of the combination SEM/CMA instrument has been described previously and the CMA and detector system has been used for low voltage electron spectroscopy. Here we discuss the use of the CMA for ARES and present some preliminary results.The CMA has been designed for an axis-to-ring focus and uses an annular type detector. This detector consists of a channel-plate/YAG/mirror assembly which is optically coupled to either a photomultiplier for spectroscopy or a TV camera for parallel detection.


Author(s):  
Zhifeng Shao

A small electron probe has many applications in many fields and in the case of the STEM, the probe size essentially determines the ultimate resolution. However, there are many difficulties in obtaining a very small probe.Spherical aberration is one of them and all existing probe forming systems have non-zero spherical aberration. The ultimate probe radius is given byδ = 0.43Csl/4ƛ3/4where ƛ is the electron wave length and it is apparent that δ decreases only slowly with decreasing Cs. Scherzer pointed out that the third order aberration coefficient always has the same sign regardless of the field distribution, provided only that the fields have cylindrical symmetry, are independent of time and no space charge is present. To overcome this problem, he proposed a corrector consisting of octupoles and quadrupoles.


Sign in / Sign up

Export Citation Format

Share Document