Features of the Flow of a Model Liquid Into a Medium with a Variable Degree of Rarefaction

Author(s):  
Alexandr Zarvin ◽  
Alexandr Yaskin ◽  
Valeriy Kalyada ◽  
Kirill Dubrovin

Abstract Experimental results of observing ethanol micro-jets expiring into a highly rarefied medium (vacuum) through a nozzle are presented. The study of the process was carried out both at the horizontal and vertical liquid stream from the source compared to the direction of gravity The residual background gas pressure in the vacuum chamber was maintained at a level much lower than the saturated vapor pressure of the working fluid at a given outlet temperature. The possibility of modeling complex processes of micro-fluids expiring into a medium with a given rarefied atmosphere on a compact vacuum gas-dynamic stand is shown. It is established that the long-term flow from a thin capillary or a small-diameter hole into a vacuum or a highly rarefied gas medium differs significantly from the well-studied flow modes into a dense gas medium, as well as from the pulsed flow modes into a vacuum. The paper describes the main features of the flow and the conditions for the occurrence of instability. It is shown that the long-term flow of a liquid micro-jet in a vacuum has a high degree of surface instability, with a large number of sudden changes in the direction, structure, and observed density. An explanation of the reasons for the destruction of the micro-jet is proposed. The formation of surface gas caverns causing explosive destruction of the micro-jet with the release of vapor-liquid droplets is established.

2020 ◽  
Vol 64 (1-4) ◽  
pp. 951-958
Author(s):  
Tianhao Liu ◽  
Yu Jin ◽  
Cuixiang Pei ◽  
Jie Han ◽  
Zhenmao Chen

Small-diameter tubes that are widely used in petroleum industries and power plants experience corrosion during long-term services. In this paper, a compact inserted guided-wave EMAT with a pulsed electromagnet is proposed for small-diameter tube inspection. The proposed transducer is noncontact, compact with high signal-to-noise ratio and unattractive to ferromagnetic tubes. The proposed EMAT is designed with coils-only configuration, which consists of a pulsed electromagnet and a meander pulser/receiver coil. Both the numerical simulation and experimental results validate its feasibility on generating and receiving L(0,2) mode guided wave. The parameters for driving the proposed EMAT are optimized by performance testing. Finally, feasibility on quantification evaluation for corrosion defects was verified by experiments.


Author(s):  
Hyungki Shin ◽  
Junhyun Cho ◽  
Young-Jin Baik ◽  
Jongjae Cho ◽  
Chulwoo Roh ◽  
...  

Power generation cycle — typically Brayton cycle — to use CO2 at supercritical state as working fluid have been researched many years because this cycle increase thermal efficiency of cycle and decrease turbomachinery size. But small turbomachinery make it difficult to develop proto type Supercritical Carbon dioxide (S-CO2) cycle equipment of lab scale size. KIER (Korea Institute of Energy Research) have been researched S-CO2 cycle since 2013. This paper is about 60kWe scale and sub-kWe class turbo generator development for applying to this S-CO2 cycle at the lab scale. A design concept of this turbo-generator is to use commercially available components so as to reduce development time and increase reliability. Major problem of SCO2 turbine is small volume flow rate and huge axial force. High density S-CO2 was referred as advantage of S-CO2 cycle because it make small turbomachinery possible. But this advantage was not valid in lab-scale cycles under 100kW because small amount volume flow rate means high rotating speed and too small diameter of turbine to manufacture it. Also, high inlet and outlet pressure make huge axial force. To solve these problem, KIER have attempt various turbines. In this paper, these attempts and results are presented and discussed.


2019 ◽  
Vol 141 (8) ◽  
Author(s):  
Anh Dinh Le ◽  
Junosuke Okajima ◽  
Yuka Iga

In industrial applications, cryogenic liquids are sometimes used as the working fluid of fluid machineries. In those fluids, the thermodynamic suppression effect of cavitation, which is normally ignored in water at room temperature, becomes obvious. When evaporation occurs in the cavitation region, the heat is supplied from the surrounding liquid. Hence, the liquid temperature is decreased, and cavitation is suppressed due to the decrease in saturated vapor pressure. Therefore, the performance of the fluid machinery can be improved. Computational fluid dynamics, which involves the use of a homogeneous model coupled with a thermal transport equation, is a powerful tool for the prediction of cavitation under thermodynamic effects. In this study, a thermodynamic model for a homogeneous model is introduced. In this model, the source term related to the latent heat of phase change appears explicitly, and the degree of heat transfer rate for evaporation and condensation can be adjusted separately to suit the homogeneous model. Our simplified thermodynamic model coupled with the Merkle cavitation model was validated for cryogenic cavitation on a two-dimensional (2D) quarter hydrofoil. The results obtained during the validation showed good agreement (in both pressure and temperature profiles) with the experimental data and were better than existing numerical results obtained by other researchers.


Author(s):  
Huayi Feng ◽  
Yanping Zhang ◽  
Chongzhe Zou

In this paper, a 3-D numerical model is proposed to investigate the capability of generating high operating temperature for a modified solar cavity receiver in large-scale dish Stirling system. The proposed model aims to evaluate the influence of radiation intensity on the cavity receiver performance. The properties of the heat transfer fluid in the pipe and heat transfer losses of the receiver are investigated by varying the direct normal irradiance from 400W/m2 to 1000W/m2. The temperature of heat transfer fluid, as well as the effect of radiation intensity on the heat transfer losses have been critically presented and discussed. The simulation results reveal that the heat transfer fluid temperature and thermal efficiency of the receiver are significantly influenced by different radiation flux. With the increase of radiation intensity, the efficiency of the receiver will firstly increase, then drops after reaching the highest point. The outlet working fluid temperature of the pipe will be increased consistently. The results of the simulations show that the designed cylindrical receiver used in dish Stirling system is capable to achieve the targeted outlet temperature and heat transfer efficiency, with an acceptable pressure drop.


Entropy ◽  
2021 ◽  
Vol 23 (11) ◽  
pp. 1476
Author(s):  
Pavel Tkachenko ◽  
Nikita Shlegel ◽  
Pavel Strizhak

The paper presents the experimental research findings for the integral characteristics of processes developing when two-phase liquid droplets collide in a heated gas medium. The experiments were conducted in a closed heat exchange chamber space filled with air. The gas medium was heated to 400–500 °C by an induction system. In the experiments, the size of initial droplets, their velocities and impact angles were varied in the ranges typical of industrial applications. The main varied parameter was the percentage of vapor (volume of bubbles) in the droplet (up to 90% of the liquid volume). The droplet collision regimes (coalescence, bounce, breakup, disruption), size and number of secondary fragments, as well as the relative volume fraction of vapor bubbles in them were recorded. Differences in the collision regimes and in the distribution of secondary fragments by size were identified. The areas of liquid surface before and after the initial droplet breakup were determined. Conditions were outlined in which vapor bubbles had a significant and, on the contrary, fairly weak effect on the interaction regimes of two-phase droplets.


2019 ◽  
Author(s):  
Hugo Krynauw ◽  
Jannik Buescher ◽  
Josepha Koehne ◽  
Loes Verrijt ◽  
Georges Limbert ◽  
...  

AbstractPurposeThe lack of long-term patency of synthetic vascular grafts currently available on the market has directed research towards improving the performance of small diameter grafts. Improved radial compliance matching and tissue ingrowth into the graft scaffold are amongst the main goals for an ideal vascular graft.MethodsBiostable polyurethane scaffolds were manufactured by electrospinning and implanted in subcutaneous and circulatory positions in the rat for 7, 14 and 28 days. Scaffold morphology, tissue ingrowth, and mechanical properties of the scaffolds were assessed before implantation and after retrieval.ResultsTissue ingrowth after 24 days was 96.5 ± 2.3% in the subcutaneous implants and 77.8 ± 5.4% in the circulatory implants. Over the 24 days implantation, the elastic modulus at 12% strain decreased by 59% in direction of the fibre alignment whereas it increased by 1379% transverse to the fibre alignment of the highly aligned scaffold of the subcutaneous implants. The lesser aligned scaffold of the circulatory graft implants exhibited an increase of the elastic modulus at 12% strain by 77% in circumferential direction.ConclusionBased on the observations, it is proposed that the mechanism underlying the softening of the highly aligned scaffold in the predominant fibre direction is associated with scaffold compaction and local displacement of fibres by the newly formed tissue. The stiffening of the scaffold, observed transverse to highly aligned fibres and for more a random fibre distribution, represents the actual mechanical contribution of the tissue that developed in the scaffold.


Author(s):  
Ms. K. P. Bhangle

Abstract: The capillary tube is commonly employed in refrigerant flow control systems. As a result, the capillary tube's performance is optimal for good refrigerant flow. Many scholars concluded performance utilising experimental, theoretical, and analysis-based methods. This paper examines the flow analysis of a refrigerant within a capillary tube under adiabatic flow circumstances. For a given mass flow rate, the suggested model can predict flow characteristics in adiabatic capillary tubes. In the current work, R-134a refrigerant has been replaced by R600a refrigerant as a working fluid inside the capillary tube, and the capillary tube design has been modified by altering length and diameter, which were obtained from reputable literature. The analysis is carried out using the ANSYS CFX 16.2 software. The results show thatutilising a small diameter and a long length (R600a refrigerant flow) is superior to the present helical capillary tube. The most appropriate helical coiled design with a diameter of 0.8 mm and a length of 3 m is proposed. Keywords: Capillary Tube, Condenser, Refrigeration effect, CFD.


2013 ◽  
Vol 724-725 ◽  
pp. 909-915
Author(s):  
Ping Fang Hu ◽  
Zhong Yi Yu ◽  
Fei Lei ◽  
Na Zhu ◽  
Qi Ming Sun ◽  
...  

A vertical U-tube ground heat exchanger can be utilized to exchange heat with the soil in ground source heat pump systems. The outlet temperature of the working fluid through the U-tube not only accounts for heat transfer capacity of a ground heat exchanger, but also greatly affects the operational efficiency of heat pump units, which is an important characteristic parameter of heat transfer process. It is quantified by defining a thermal effectiveness coefficient. The performance evaluation is performed with a three dimensional numerical model using a finite volume technique. A dynamic simulation was conducted to analyze the thermal effectiveness as a function of soil thermal properties, backfill material properties, separation distance between the two tube legs, borehole depth and flow velocity of the working fluid. The influence of important characteristic parameters on the heat transfer performance of vertical U-tube ground heat exchangers is investigated, which may provide the references for the design of ground source heat pump systems in practice.


2011 ◽  
Vol 383-390 ◽  
pp. 6071-6078
Author(s):  
E. H. Wang ◽  
H. G. Zhang ◽  
B. Y. Fan ◽  
H. Liang ◽  
M. G. Ouyang

Energy saving and environment protection are two important issues that today’s automobile industry must emphasize. Lots of heat energy waste with the exhaust gas when the engine is running. If this part of waste heat can be recovered, the energy efficiency will be improved. Thus plenty of energy can be saved and the global warming also can be reduced. In this paper, the organic Rankine cycle whose working fluid was R245fa was studied. It was adopted to recover the gasoline engine waste heat. The mathematical model of the organic Rankine cycle was built up in Matlab to search the optimized working condition. The pinch analysis method was used to analyze the outlet temperature of the exhaust gas. The results indicate that organic Rankine cycle is a good way to recover the gasoline engine waste heat, especially in the high load conditions. The temperature of the exhaust gas can be apparently decreased.


Sign in / Sign up

Export Citation Format

Share Document