microwave cavity
Recently Published Documents


TOTAL DOCUMENTS

760
(FIVE YEARS 124)

H-INDEX

46
(FIVE YEARS 6)

Author(s):  
Tim Jacobus Adrianus Staps ◽  
Tim Jacobus Maria Donders ◽  
Bart Platier ◽  
J Beckers

Abstract Negative ions are an important constituent of the spatial afterglow of atmospheric pressure plasmas, where the fundamental plasma-substrate interactions take place that are vital for applications such as biomedicine, material synthesis, and ambient air treatment. In this work, we use laser-induced photodetachment to liberate electrons from negative ions in the afterglow region of an atmospheric pressure plasma jet interacting with an argon-oxygen mixture, and microwave cavity resonance spectroscopy (MCRS) to detect the photodetached electrons. This diagnostic technique allows for the determination of the electron density and the effective collision frequency before, during and after the laser pulse was shot through the measurement volume with nanosecond time resolution. From a laser saturation study, it is concluded that O− is the dominant negative ion in the afterglow. Moreover, the decay of the photodetached electron density is found to be dominantly driven by the (re)formation of O− by dissociative attachment of electrons with O2. As a consequence, we identified the species and process responsible for the formation of negative ions in the spatial afterglow in our experiment.


2021 ◽  
Vol 104 (22) ◽  
Author(s):  
Vahid Azimi Mousolou ◽  
Yuefei Liu ◽  
Anders Bergman ◽  
Anna Delin ◽  
Olle Eriksson ◽  
...  
Keyword(s):  

2021 ◽  
Vol 38 (11) ◽  
pp. 110303
Author(s):  
Zhiling Wang ◽  
Zenghui Bao ◽  
Yukai Wu ◽  
Yan Li ◽  
Cheng Ma ◽  
...  

High fidelity single shot qubit state readout is essential for many quantum information processing protocols. In superconducting quantum circuit, the qubit state is usually determined by detecting the dispersive frequency shift of a microwave cavity from either transmission or reflection. We demonstrate the use of constructive interference between the transmitted and reflected signal to optimize the qubit state readout, with which we find a better resolved state discrimination and an improved qubit readout fidelity. As a simple and convenient approach, our scheme can be combined with other qubit readout methods based on the discrimination of cavity photon states to further improve the qubit state readout.


2021 ◽  
Vol 2086 (1) ◽  
pp. 012216
Author(s):  
R K Zakharov ◽  
E K Bashkirov

Abstract We studied the dynamics of two qubits interacting with one-mode thermal quantum electromagnetic field of microwave cavity with Kerr medium. Using the exact solution for considered model we derived the qubit-qubit negativity for separa coherent initial qubits states. We showed that initial qubits coherencee interaction can greatly enhance the degree of qubits entanglement in the presence of the Kerr nonlinearity and dipole-dipole interactionyeven for high thermal field intensities.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
L. C. Contamin ◽  
M. R. Delbecq ◽  
B. Douçot ◽  
A. Cottet ◽  
T. Kontos

AbstractTopological excitations, such as Majorana zero modes, are a promising route for encoding quantum information. Topologically protected gates of Majorana qubits, based on their braiding, will require some form of network. Here, we propose to build such a network by entangling Majorana matter with light in a microwave cavity QED set-up. Our scheme exploits a light-induced interaction which is universal to all the Majorana nanoscale circuit platforms. This effect stems from a parametric drive of the light-matter coupling in a one-dimensional chain of physical Majorana modes. Our set-up enables all the basic operations needed in a Majorana quantum computing platform such as fusing, braiding, the crucial T-gate, the read-out, and importantly, the stabilization or correction of the physical Majorana modes.


Author(s):  
Myles Ruether ◽  
Clinton A Potts ◽  
John P Davis ◽  
Lindsay Jane LeBlanc

Abstract Microwave cavity resonators are crucial components of many quantum technologies and are a promising platform for hybrid quantum systems, as their open architecture enables the integration of multiple subsystems inside the cavity volume. To support these subsystems within the cavity, auxiliary structures are often required, but the effects of these structures on the microwave cavity mode are difficult to predict due to a lack of a priori knowledge of the materials’ response in the microwave regime. Understanding these effects becomes even more important when frequency matching is critical and tuning is limited, for example, when matching microwave modes to atomic resonances. Here, we study the microwave cavity mode in the presence of three commonly-used machinable polymers, paying particular attention to the change in resonance and the dissipation of energy. We demonstrate how to use the derived dielectric coefficient and loss tangent parameters for cavity design in a test case, wherein we match a polymer-filled 3D microwave cavity to a hyperfine transition in rubidium.


Processes ◽  
2021 ◽  
Vol 9 (11) ◽  
pp. 2076
Author(s):  
Elna J. K. Nilsson ◽  
Tomas Hurtig ◽  
Andreas Ehn ◽  
Christer Fureby

Laminar burning velocity of lean methane/air flames exposed to pulsed microwave irradiation is determined experimentally as part of an effort to accurately quantify the enhancement resulting from exposure of the flame to pulsed microwaves. The experimental setup consists of a heat flux burner mounted in a microwave cavity, where the microwave has an average power of up to 250 W at an E-field in the range of 350–380 kV/m. Laminar burning velocities for the investigated methane/air flames increase from 1.8 to 12.7% when exposed to microwaves. The magnitude of the enhancement is dependent on pulse sequence (duration and frequency) and the strength of the electric field. From the investigated pulse sequences, and at a constant E-field and average power, the largest effect on the flame is obtained for the longest pulse, namely 50 μs. The results presented in this work are, to the knowledge of the authors, the first direct determination of laminar burning velocity on a laminar stretch-free flame exposed to pulsed microwaves.


Author(s):  
Tim Jacobus Adrianus Staps ◽  
Tim Jacobus Maria Donders ◽  
Bart Platier ◽  
J Beckers

Abstract A dust grain immersed in a low-pressure gas discharge obtains a permanent negative surface charge due to the high mobility of electrons compared to that of ions. This charge essentially governs all fundamental processes in dusty and complex plasmas involving dust grains, neutrals, (an)ions and electrons and—consequently—virtually all industrial applications of these types of plasmas are affected and steered by it. In this work, we have measured the surface charge by application of laser-induced electron detachment from nanosized dust grains in concert with microwave cavity resonance spectroscopy and laser light extinction. The main result is that the electron release is governed by photodetachment rather than by thermionic emission, and that recharging of the dust grains occurs on timescales that are well in agreement with the orbital-motion-limited (OML) theory. The total surface charge density residing on the dust grains inside the laser volume follows from the saturation of the photodetachment signal, which was used in combination with dust density values derived from extinction measurements to estimate the mean dust charge. The negative dust charge on the 140 nm (average) diameter dust grains in this work is obtained to be in the range of 273 − 2519 elementary charges, of which the lower bound matches well with analytical predictions using the orbital-motion-limited (OML) theory.


2021 ◽  
pp. 102584
Author(s):  
Zhen Li ◽  
Zhaozong Meng ◽  
Changcheng Wu ◽  
Constantinos Soutis ◽  
Zhijun Chen ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (21) ◽  
pp. 7021
Author(s):  
Dalia M. Elsheakh ◽  
Mohamed I. Ahmed ◽  
Gomaa M. Elashry ◽  
Saad M. Moghannem ◽  
Hala A. Elsadek ◽  
...  

This paper presents a rapid diagnostic device for the detection of the pandemic coronavirus (COVID-19) using a micro-immunosensor cavity resonator. Coronavirus has been declared an international public health crisis, so it is important to design quick diagnostic methods for the detection of infected cases, especially in rural areas, to limit the spread of the virus. Herein, a proof-of-concept is presented for a portable laboratory device for the detection of the SARS-CoV-2 virus using electromagnetic biosensors. This device is a microwave cavity resonator (MCR) composed of a sensor operating at industrial, scientific and medical (ISM) 2.45 GHz inserted in 3D housing. The changes of electrical properties of measured serum samples after passing the sensor surface are presented. The three change parameters of the sensor are resonating frequency value, amplitude and phase of the reflection coefficient |S11|. This immune-sensor offers a portable, rapid and accurate diagnostic method for the SARS-CoV-2 virus, which can enable on-site diagnosis of infection. Medical validation for the device is performed through biostatistical analysis using the ROC (Receiver Operating Characteristic) method. The predictive accuracy of the device is 63.3% and 60.6% for reflection and phase, respectively. The device has advantages of low cost, low size and weight and rapid response. It does need a trained technician to operate it since a software program operates automatically. The device can be used at ports’ quarantine units, hospitals, etc.


Sign in / Sign up

Export Citation Format

Share Document