visibility score
Recently Published Documents


TOTAL DOCUMENTS

10
(FIVE YEARS 8)

H-INDEX

2
(FIVE YEARS 1)

2021 ◽  
Vol 28 (2) ◽  
pp. 21
Author(s):  
Deb K. Boruah ◽  
Bidyut Bikash Gogoi ◽  
Kuntal Kanti Das ◽  
Kalyan Sarma ◽  
Pranjal Phukan ◽  
...  

Background: Prompt diagnosis and early treatment institution are important in intraventricular neurocysticercosis(IVNCC) as compared to the parenchymal or racemose form because it is associated with a poorer patient prognosis. Intraventricular neurocysticercosis is often missed on CT scan or conventional cranial magnetic resonance imaging because of similar density or signal intensity of cysticercus lesion with cerebrospinal fluid. Thestudy aims to evaluate the added value of 3D-DRIVE and SWI MRI sequences in isolated intraventricular cysticercosis with acute neurological presentation.Methods and Materials: This retrospective study was carried out on diagnosed 10patients with isolated intraventricular neurocysticercosis(IVNCC) presented to a tertiary care hospital with an acute onset of symptoms or acute neurological deficit between June 2019 to May 2021. Relevant neurological examination, CSF analysis, a serological test of neurocysticercosis and MRI scan of the brain were performed.Result: Tenpatients of isolated intraventricular neurocysticercosis (3 males and 7 females) having 3 pediatric and7 adults were included in this study sample.The common neurological complications of the isolated intraventricular neurocysticercosis in this study are observed as obstructive hydrocephalus in 8(80%) patients and ependymitis in 7(70%) patients.IVNCC with distinctly visualized scolex (visibility score 2) identified in 2(20%) patients in T2WI, 8 (80%)patients in 3D-DRIVE and 3(30%) patients in SWI sequences. The cyst wall of IVNCC was distinctly visualized (visibility score 2) in 1(10%) patient in T2WI, 8(80%) patientsin 3D-DRIVE and 6(60%) patients in SWI sequence.Conclusion: Heavily T2-weighted steady-state and SWI sequences should be added to routine MRI sequences that helps to identify IVNCC and should be used in patients with unexplained hydrocephalus, especially in endemic regions of Neurocysticercosis.


2021 ◽  
Vol 11 (1) ◽  
pp. 119
Author(s):  
Toshihiro Nishizawa ◽  
Osamu Toyoshima ◽  
Shuntaro Yoshida ◽  
Chie Uekura ◽  
Ken Kurokawa ◽  
...  

Background and aim: Olympus Corporation released the texture and color enhancement imaging (TXI) technology as a novel image-enhancing endoscopic technique. We investigated the effectiveness of TXI in the imaging of serrated colorectal polyps, including sessile serrated lesions (SSLs). Methods: Serrated colorectal polyps were observed using white light imaging (WLI), TXI, narrow-band imaging (NBI), and chromoendoscopy with and without magnification. Serrated polyps were histologically confirmed. TXI was compared with WLI, NBI, and chromoendoscopy for the visibility of the lesions without magnification and for that of the vessel and surface patterns with magnification. Three expert endoscopists evaluated the visibility scores, which were classified from 1 to 4. Results: Twenty-nine consecutive serrated polyps were evaluated. In the visibility score without magnification, TXI was significantly superior to WLI but inferior to chromoendoscopy in the imaging of serrated polyps and the sub-analysis of SSLs. In the visibility score for vessel patterns with magnification, TXI was significantly superior to WLI and chromoendoscopy in the imaging of serrated polyps and the sub-analysis of SSLs. In the visibility score for surface patterns with magnification, TXI was significantly superior to WLI but inferior to NBI in serrated polyps and in the sub-analysis of SSLs and hyperplastic polyps. Conclusions: TXI provided higher visibility than did WLI for serrated, colorectal polyps, including SSLs.


Cancers ◽  
2021 ◽  
Vol 13 (14) ◽  
pp. 3564
Author(s):  
Jonathan Pham ◽  
Ricky R. Savjani ◽  
Yu Gao ◽  
Minsong Cao ◽  
Peng Hu ◽  
...  

Purpose: To evaluate urethral contours from two optimized urethral MRI sequences with an MR-guided radiotherapy system (MRgRT). Methods: Eleven prostate cancer patients were scanned on a MRgRT system using optimized urethral 3D HASTE and 3D TSE. A resident radiation oncologist contoured the prostatic urethra on the patients’ planning CT, diagnostic 3T T2w MRI, and both urethral MRIs. An attending radiation oncologist reviewed/edited the resident’s contours and additionally contoured the prostatic urethra on the clinical planning MRgRT MRI (bSSFP). For each image, the resident radiation oncologist, attending radiation oncologist, and a senior medical physicist qualitatively scored the prostatic urethra visibility. Using MRgRT 3D HASTE-based contouring workflow as baseline, prostatic urethra contours drawn on CT, diagnostic MRI, clinical bSSFP and 3D TSE were evaluated relative to the contour on 3D HASTE using 95th percentile Hausdorff distance (HD95), mean-distance-to-agreement (MDA), and DICE coefficient. Additionally, prostatic urethra contrast-to-noise-ratios (CNR) were calculated for all images. Results: For two out of three observers, the urethra visibility score for 3D HASTE was significantly higher than CT, and clinical bSSFP, but was not significantly different from diagnostic MRI. The mean HD95/MDA/DICE values were 11.35 ± 3.55 mm/5.77 ± 2.69 mm/0.07 ± 0.08 for CT, 7.62 ± 2.75 mm/3.83 ± 1.47 mm/0.12 ± 0.10 for CT + diagnostic MRI, 5.49 ± 2.32 mm/2.18 ± 1.19 mm/0.35 ± 0.19 for 3D TSE, and 6.34 ± 2.89 mm/2.65 ± 1.31 mm/0.21 ± 0.12 for clinical bSSFP. The CNR for 3D HASTE was significantly higher than CT, diagnostic MRI, and clinical bSSFP, but was not significantly different from 3D TSE. Conclusion: The urethra’s visibility scores showed optimized urethral MRgRT 3D HASTE was superior to the other tested methodologies. The prostatic urethra contours demonstrated significant variability from different imaging and workflows. Urethra contouring uncertainty introduced by cross-modality registration and sub-optimal imaging contrast may lead to significant treatment degradation when urethral sparing is implemented to minimize genitourinary toxicity.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Tsubasa Ishikawa ◽  
Tomoaki Matsumura ◽  
Kenichiro Okimoto ◽  
Ariki Nagashima ◽  
Wataru Shiratori ◽  
...  

AbstractIn 2020, Olympus Medical Systems Corporation introduced the Texture and Color Enhancement Imaging (TXI) as a new image-enhanced endoscopy. This study aimed to evaluate the visibility of neoplasms and mucosal atrophy in the upper gastrointestinal tract through TXI. We evaluated 72 and 60 images of 12 gastric neoplasms and 20 gastric atrophic/nonatrophic mucosa, respectively. The visibility of gastric mucosal atrophy and gastric neoplasm was assessed by six endoscopists using a previously reported visibility scale (1 = poor to 4 = excellent). Color differences between gastric mucosal atrophy and nonatrophic mucosa and between gastric neoplasm and adjacent areas were assessed using the International Commission on Illumination L*a*b* color space system. The visibility of mucosal atrophy and gastric neoplasm was significantly improved in TXI mode 1 compared with that in white-light imaging (WLI) (visibility score: 3.8 ± 0.5 vs. 2.8 ± 0.9, p < 0.01 for mucosal atrophy; visibility score: 2.8 ± 1.0 vs. 2.0 ± 0.9, p < 0.01 for gastric neoplasm). Regarding gastric atrophic and nonatrophic mucosae, TXI mode 1 had a significantly greater color difference than WLI (color differences: 14.2 ± 8.0 vs. 8.7 ± 4.2, respectively, p < 0.01). TXI may be a useful observation modality in the endoscopic screening of the upper gastrointestinal tract.


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Taro Iwatsubo ◽  
Ryu Ishihara ◽  
Yasushi Yamasaki ◽  
Yusuke Tonai ◽  
Kenta Hamada ◽  
...  

Abstract Background The current virtual chromoendoscopy equipment cannot completely detect superficial squamous cell carcinoma (SCC) in the esophagus, despite its development in the recent years. Thus, in this study, we aimed to elucidate the appropriate air volume during endoscopic observation to improve the visibility of esophageal SCC. Methods This retrospective study included a total of 101 flat type esophageal SCCs identified between April 2017 and January 2019 at the Department of Gastrointestinal Oncology, Osaka International Cancer Institute. Video images of narrow band imaging (NBI) under both less-air and standard-air conditions were recorded digitally. Videos were evaluated by five endoscopists. Relative visibility between less-air and standard-air conditions of the brownish area, brownish color change of the epithelium, and dilated intrapapillary capillary loop (IPCL) were graded as 5 (definitely better under less-air condition) to 1 (definitely worse under less-air condition), with 3 indicating average visibility (equivalent to standard-air observation). Results The mean (standard deviation) visibility score of the brownish area, brownish color change of the epithelium, and dilated IPCLs under less-air condition were 3.94 (0.58), 3.73 (0.57), and 4.13 (0.60), respectively, which were significantly better than that under standard-air condition (p < 0.0001). Esophageal SCC evaluated as ≥ 4 in the mean visibility score of the brownish area, brownish color change of the epithelium, and dilated IPCLs accounted for 50% (51/101 lesions), 34% (34/101 lesions), and 67% (68/101 lesions), respectively. Conclusions The present results suggested that NBI with less air might improve the visibility of flat type esophageal SCC compared with NBI with standard air. Less-air NBI observation may facilitate the detection of flat type esophageal SCC. Trial registration The present study is a non-intervention trial.


Author(s):  
AK Koushik ◽  
V Saketh ◽  
P Ganesh ◽  
S Shanmughanathan

Introduction: Dimethicone enhances diagnostic accuracy in Oesophagogastroduodenoscopy (EGD). Various regimens have been tried to ease the procedure for better mucosal visibility. Aim: To evaluate the efficacy of activated dimethicone in improving endoscopic visibility. Materials and Methods: The present prospective study was carried out from February 2017 to February 2018 in a tertiary teaching hospital, Chennai, India. A total of 2917 patients aged 18-70 years were enrolled for this study. The participants were divided into group S (1540 patients) and group C (1377 patients). Group S received activated dimethicone 30 minutes before the procedure and group C underwent procedure without any pre-procedure preparation. The mucosal visibility score was evaluated in both the groups. Statistical analysis was conducted using IBM SPSS statistics (version 23.0). Unpaired student’s t-test and Pearson Chi-Square test are used for statistical analysis of the data and in both, p<0.05 was considered as significant level. Results: The mucosal visibility score in oesophagus, stomach, antrum and duodenum was significantly better in group S patients compared to group C patients. Duration of endoscopy was significantly (p-value 0.0005) shorter (7.95 min) in the group S compared with the group C (8.17 min). The amount of flush used was on an average 3 mL less for group S than group C, which was also significant (p-value 0.0005). Conclusion: Activated dimethicone pre-preparation to EGD significantly increased the mucosal visibility during procedure and decreased the endoscopy duration.


2019 ◽  
Vol 07 (12) ◽  
pp. E1632-E1635 ◽  
Author(s):  
Naohisa Yahagi ◽  
Ai Fujimoto ◽  
Joichiro Horii ◽  
Toshio Uraoka ◽  
Masayuki Shimoda ◽  
...  

Abstract Background Dual red imaging (DRI), a novel image-enhanced endoscopy (IEE) technology, has the potential to improve the visibility of blood vessels in deeper tissue using 600 nm and 630 nm wavelength lights in the red band. Aim To confirm the feasibility of DRI in visualization of vessels in deeper tissue and identify pathologically the features of blood vessels visualized by DRI. Methods Study 1: visibility of blood vessels was assessed by five observers in 137 pairs of DRI and white light imaging (WLI) images. The scores for the visibility of thick blood vessels were measured for randomized images and compared with the scoring template as a reference. The difference in visibility score between DRI and WLI was compared in each pair of images. Study 2: blood vessels detected only by DRI were examined pathologically using two pig stomachs. Results Study 1: The mean visibility scores of DRI and WLI for each observer were 1.69 – 2.26 and 1.31 – 1.67, respectively. The mean difference in visibility score and 95 % confidence interval for the five observers was 0.59 [0.46 – 0.72], 0.54 [0.40 – 0.68], 0.34 [0.18 – 0.49], 0.51 [0.36 – 0.66], and 0.71 [0.54 – 0.88]. The visibility was statistically significantly better in DRI than in WLI for all observers (P < 0.0001). Study 2: three blood vessels were observed only by DRI. All of these blood vessels were located at a depth of 1000 – 1500 µm from the mucosal surface. The diameter of these blood vessels exceeded 80 – 200 µm. Conclusions DRI can feasibly detect thick blood vessels in the deep mucosa or submucosa of the gastrointestinal tract.


2019 ◽  
Vol 8 (4) ◽  
Author(s):  
Minjuan Wang

This study examines the relationship between student visibility and learning outcomes in a graduate-level online course. Visibility in this study refers to students’ cognitive, social, and emotive presence [1, 2] in various communication settings, such as posts on the discussion board, contributions in live chats, email messages, online profiles, and inputs via any other means of communication. A visibility score is determined for each student, and the Spearman r correlational tests are used to detect any significant correlation between visibility and learning outcomes (grades). In addition, two surveys were distributed to the students at the end of the course: (a) Survey on Self-Perception on Learning Experiences provides a context for understanding student performance; and (b) Survey on Useful Aspects of Socializing Online asks students to rank the importance of eight types of online activities, such as sharing information, solving problems, and making friends. Both surveys probe into students’ perceptions and social context, which often have great impact on students’ online presence.


Endoscopy ◽  
2018 ◽  
Vol 51 (05) ◽  
pp. 463-467 ◽  
Author(s):  
Vinh-An Phan ◽  
Raymond Dalfsen ◽  
Hien Le ◽  
Nam Q. Nguyen

Abstract Background Insertion of fiducials to outline the targeted lesion allows image-guided radiotherapy, and is best achieved by endoscopic ultrasound (EUS). This study is a performance comparison of the new EUS-guided preloaded fiducial needle against Visicoil fiducials. Methods Technical success, visibility score, procedural time, costs, and complications for patients who underwent EUS-guided fiducial placement in upper gastrointestinal malignancies were prospectively collected. Results 60 patients with upper gastrointestinal cancers had fiducials (14 Visicoil; 46 preloaded fiducials) inserted for image-guided radiotherapy. Technical success was 100 %, with a shorter mean (standard deviation) insertion time of 0.94 minutes (0.28 minutes) vs. 5.5 minutes (1.9 minutes; P < 0.001) and higher visibility score on fluoroscopy of 2 vs. 1.18 (P < 0.001) in the preloaded group. Neither group had major complications related to fiducial insertion. The cost of consumables per patient was lower in the preloaded group at US$480 (US$124) vs. US$643 (US$123; P < 0.001). Conclusion Fiducial insertion for image-guided radiotherapy using the new preloaded needle is associated with 100 % technical success, shorter insertion time, and higher visibility, and is more cost-effective than the Visicoil system.


2017 ◽  
Vol 05 (06) ◽  
pp. E518-E525 ◽  
Author(s):  
Naohisa Yoshida ◽  
Yuji Naito ◽  
Takaaki Murakami ◽  
Ryohei Hirose ◽  
Kiyoshi Ogiso ◽  
...  

Abstract Background/study aim Linked color imaging (LCI) by a laser endoscope (Fujifilm Co, Tokyo, Japan) is a novel narrow band light observation. In this study, we aimed to investigate whether LCI could improve the visibility of colorectal polyps using endoscopic videos. Patients and methods We prospectively recorded videos of consecutive polyps 2 – 20 mm in size diagnosed as neoplastic polyps. Three videos, white light (WL), blue laser imaging (BLI)-bright, and LCI, were recorded for each polyp by one expert. After excluding inappropriate videos, all videos were evaluated in random order by two experts and two non-experts according to a published polyp visibility score from four (excellent visibility) to one (poor visibility). Additionally, the relationship between polyp visibility scores in LCI and various clinical characteristics including location, size, histology, morphology, and preparation were analyzed compared to WL and BLI-bright. Results We analyzed 101 colorectal polyps (94 neoplastic) in 66 patients (303 videos). The mean polyp size was 9.0 ± 8.1 mm and 54 polyps were non-polypoid. The mean polyp visibility scores for LCI (2.86 ± 1.08) were significantly higher than for WL and BLI-bright (2.53 ± 1.15, P < 0.001; 2.73 ± 1.47, P < 0.041). The ratio of poor visibility (score 1 and 2) was significantly lower in LCI for experts and non-experts (35.6 %, 33.6 %) compared with WL (49.6 %, P = 0.015, 50.5 %, P = 0.046). The polyp visibility scores for LCI were significantly higher than those for WL for all of the factors. With respect to the comparison between BLI-bright and WL, the polyp visibility scores for BLI-bright were not higher than WL for right-sided location, < 10 mm size, sessile serrated adenoma and polyp histology, and poor preparation. For those characteristics, LCI improved the lesions with right-sided location, SSA/P histology, and poor preparation significantly better than BLI. Conclusions LCI improved polyp visibility compared to WL for both expert and non-expert endoscopists. It is useful for improving polyp visibility in any location, any size, any morphology, any histology, and any preparation level.Study registration: UMIN000013770


Sign in / Sign up

Export Citation Format

Share Document