Volume 3: Coal, Biomass and Alternative Fuels; Cycle Innovations; Electric Power; Industrial and Cogeneration
Latest Publications


TOTAL DOCUMENTS

69
(FIVE YEARS 0)

H-INDEX

4
(FIVE YEARS 0)

Published By American Society Of Mechanical Engineers

9780791856673

Author(s):  
Valentina Zaccaria ◽  
Alberto Traverso ◽  
David Tucker

The theoretical efficiencies of gas turbine fuel cell hybrid systems make them an ideal technology for the future. Hybrid systems focus on maximizing the utilization of existing energy technologies by combining them. However, one pervasive limitation that prevents the commercialization of such systems is the relatively short lifetime of fuel cells, which is due in part to several degradation mechanisms. In order to improve the lifetime of hybrid systems and to examine long-term stability, a study was conducted to analyze the effects of electrochemical degradation in a solid oxide fuel cell (SOFC) model. The SOFC model was developed for hardware-in-the-loop simulation with the constraint of real-time operation for coupling with turbomachinery and other system components. To minimize the computational burden, algebraic functions were fit to empirical relationships between degradation and key process variables: current density, fuel utilization, and temperature. Previous simulations showed that the coupling of gas turbines and SOFCs could reduce the impact of degradation as a result of lower fuel utilization and more flexible current demands. To improve the analytical capability of the model, degradation was incorporated on a distributed basis to identify localized effects and more accurately assess potential failure mechanisms. For syngas fueled systems, the results showed that current density shifted to underutilized sections of the fuel cell as degradation progressed. Over-all, the time to failure was increased, but the temperature difference along cell was increased to unacceptable levels, which could not be determined from the previous approach.


Author(s):  
Mohammad Mansouri Majoumerd ◽  
Mohsen Assadi ◽  
Peter Breuhaus ◽  
Øystein Arild

The overall goal of the European co-financed H2-IGCC project was to provide and demonstrate technical solutions for highly efficient and reliable gas turbine technology in the next generation of integrated gasification combined cycle (IGCC) power plants with CO2 capture suitable for combusting undiluted H2-rich syngas. This paper aims at providing an overview of the main activities performed in the system analysis working group of the H2-IGCC project. These activities included the modeling and integration of different plant components to establish a baseline IGCC configuration, adjustments and modifications of the baseline configuration to reach the selected IGCC configuration, performance analysis of the selected plant, performing techno-economic assessments and finally benchmarking with competing fossil-based power technologies. In this regard, an extensive literature survey was performed, validated models (components and sub-systems) were used, and inputs from industrial partners were incorporated into the models. Accordingly, different plant components have been integrated considering the practical operation of the plant. Moreover, realistic assumptions have been made to reach realistic techno-economic evaluations. The presented results show that the efficiency of the IGCC plant with CO2 capture is 35.7% (lower heating value basis). The results also confirm that the efficiency is reduced by 11.3 percentage points due to the deployment of CO2 capture in the IGCC plant. The specific capital costs for the IGCC plant with capture are estimated to be 2,901 €/(kW net) and the cost of electricity for such a plant is 90 €/MWh. It is also shown that the natural gas combined cycle without CO2 capture requires the lowest capital investment, while the lowest cost of electricity is related to IGCC plant without CO2 capture.


Author(s):  
Ryohei Yokoyama ◽  
Masashi Ohkura ◽  
Tetsuya Wakui

In designing energy supply systems, designers should consider that energy demands and costs as parameters have some uncertainties, evaluate the robustness in system performances against the uncertainties, and design the systems rationally to heighten the robustness. A robust optimal design method of energy supply systems under only uncertain energy demands was revised so that it can be applied to systems with complex configurations and large numbers of periods for variations in energy demands. In addition, a method of comparing performances of two energy supply systems under only uncertain energy demands was proposed by utilizing a part of the revised robust optimal design method. In this paper, the revised robust optimal design method as well as the proposed performance comparison method are extended so that they can be applied to the robust optimal design and the performance comparison of energy supply systems under not only uncertain energy demands but also uncertain energy costs. Through a case study on a gas turbine cogeneration system for district energy supply, the validity and effectiveness of the extended optimal design method and features of the robust optimal design are clarified. In addition, the gas turbine cogeneration system is compared with a conventional energy supply system using the extended performance comparison method.


Author(s):  
Christian Felsmann ◽  
Uwe Gampe ◽  
Manfred Freimark

Solar hybrid gas turbine technology has the potential to increase the efficiency of future solar thermal power plants by utilizing solar heat at a much higher temperature level than state of the art plants based on steam turbine cycles. In a previous paper the authors pointed out, that further development steps are required for example in the field of component development and in the investigation of the system dynamics to realize a mature technology for commercial application [1]. In this paper new findings on system dynamics are presented based on the simulation model of a solar hybrid gas turbine with parallel arrangement of the combustion chamber and solar receivers. The operational behavior of the system is described by means of two different scenarios. The System operation in a stand-alone electrical supply network is investigated in the first scenario. Here it is shown that fast load changes in the network lead to a higher shaft speed deviation of the electric generator compared to pure fossil fired systems. In the second scenario a generator load rejection, as a worst case, is analyzed. The results make clear that additional relief concepts like blow-off valves are necessary as the standard gas turbine protection does not meet the specific requirements of the solar hybrid operation. In general the results show, that the solar hybrid operational modes are much more challenging for the gas turbines control and safety system compared to pure fossil fired plants due to the increased volumetric storage capacity of the system.


Author(s):  
Wolfgang Kappis ◽  
Stefan Florjancic ◽  
Uwe Ruedel

Market requirements for the heavy duty gas turbine power generation business have significantly changed over the last few years. With high gas prices in former times, all users have been mainly focusing on efficiency in addition to overall life cycle costs. Today individual countries see different requirements, which is easily explainable picking three typical trends. In the United States, with the exploitation of shale gas, gas prices are at a very low level. Hence, many gas turbines are used as base load engines, i.e. nearly constant loads for extended times. For these engines reliability is of main importance and efficiency somewhat less. In Japan gas prices are extremely high, and therefore the need for efficiency is significantly higher. Due to the challenge to partly replace nuclear plants, these engines as well are mainly intended for base load operation. In Europe, with the mid and long term carbon reduction strategy, heavy duty gas turbines is mainly used to compensate for intermittent renewable power generation. As a consequence, very high cyclic operation including fast and reliable start-up, very high loading gradients, including frequency response, and extended minimum and maximum operating ranges are required. Additionally, there are other features that are frequently requested. Fuel flexibility is a major demand, reaching from fuels of lower purity, i.e. with higher carbon (C2+), content up to possible combustion of gases generated by electrolysis (H2). Lifecycle optimization, as another important request, relies on new technologies for reconditioning, lifetime monitoring, and improved lifetime prediction methods. Out of Alstom’s recent research and development activities the following items are specifically addressed in this paper. Thermodynamic engine modelling and associated tasks are discussed, as well as the improvement and introduction of new operating concepts. Furthermore extended applications of design methodologies are shown. An additional focus is set ono improve emission behaviour understanding and increased fuel flexibility. Finally, some applications of the new technologies in Alstom products are given, indicating the focus on market requirements and customer care.


Author(s):  
Fredrik Ahlgren ◽  
Maria E. Mondejar ◽  
Magnus Genrup ◽  
Marcus Thern

Maritime transportation is a significant contributor to SOx, NOx and particle matter emissions, even though it has a quite low CO2 impact. New regulations are being enforced in special areas that limit the amount of emissions from the ships. This fact, together with the high fuel prices, is driving the marine industry towards the improvement of the energy efficiency of current ship engines and the reduction of their energy demand. Although more sophisticated and complex engine designs can improve significantly the efficiency of the energy systems in ships, waste heat recovery arises as the most influent technique for the reduction of the energy consumption. In this sense, it is estimated that around 50% of the total energy from the fuel consumed in a ship is wasted and rejected in fluid and exhaust gas streams. The primary heat sources for waste heat recovery are the engine exhaust and the engine coolant. In this work, we present a study on the integration of an organic Rankine cycle (ORC) in an existing ship, for the recovery of the main and auxiliary engines exhaust heat. Experimental data from the operating conditions of the engines on the M/S Birka Stockholm cruise ship were logged during a port-to-port cruise from Stockholm to Mariehamn over a period of time close to one month. The ship has four main engines Wärtsilä 5850 kW for propulsion, and four auxiliary engines 2760 kW used for electrical consumers. A number of six load conditions were identified depending on the vessel speed. The speed range from 12–14 knots was considered as the design condition, as it was present during more than 34% of the time. In this study, the average values of the engines exhaust temperatures and mass flow rates, for each load case, were used as inputs for a model of an ORC. The main parameters of the ORC, including working fluid and turbine configuration, were optimized based on the criteria of maximum net power output and compactness of the installation components. Results from the study showed that an ORC with internal regeneration using benzene would yield the greatest average net power output over the operating time. For this situation, the power production of the ORC would represent about 22% of the total electricity consumption on board. These data confirmed the ORC as a feasible and promising technology for the reduction of fuel consumption and CO2 emissions of existing ships.


Author(s):  
Nicolas Demougeot ◽  
Jeffrey A. Benoit

The search for power plant sustainability options continues as regulating agencies exert more stringent industrial gas turbine emission requirements on operators. Purchasing power for resale, de-commissioning current capabilities altogether and repowering by replacing or converting existing equipment to comply with emissions standards are economic-driven options contemplated by many mature gas turbine operators. NRG’s Gilbert power plant based in Milford, NJ began commercial operation in 1974 and is fitted with four (4) natural gas fired GE’s 7B gas turbine generators with two each exhausting to HRSG’s feeding one (1) steam turbine generator. The gas turbine units, originally configured with diffusion flame combustion systems with water injection, were each emitting 35 ppm NOx with the New Jersey High Energy Demand Day (HEED) regulatory mandate to reduce NOx emissions to sub 10 ppm by May 1st, 2015. Studies were conducted by the operator to evaluate the economic viability & installation of environmental controls to reduce NOx emissions. It was determined that installation of post-combustion environmental controls at the facility was both cost prohibitive and technically challenging, and would require a fundamental reconfiguration of the facility. Based on this economic analysis, the ultra-low emission combustion system conversion package was selected as the best cost-benefit solution. This technical paper will focus on the ultra low emissions technology and key features employed to achieve these low emissions, a description of the design challenges and solution to those, a summary of the customer considerations in down selecting options and an overview of the conversion scope. Finally, a technical discussion of the low emissions operational flexibility will be provided including performance results of the converted units.


Author(s):  
Christopher A. Perullo ◽  
Josh Barron ◽  
Dale Grace ◽  
Leonard Angello ◽  
Tim Lieuwen

Gas turbines ingest large quantities of air during operation. As a result, large quantities of foreign particles ranging in size from smoke (0.01 to 1.0 micron) to pollen (10 micron) enter the unit and can contribute to both fouling and erosion depending on particle size. Fouling and erosion both lead to reductions in unit output and efficiency resulting in increased operational cost. Operators have historically combatted fouling through a combination of online water washes, more effective off-line water washes, and air filtration. As is the case with almost all engineering problems, the trade-off between the cost and effectiveness of these methods must be evaluated. Online washing is somewhat effective but has led to first stage blade erosion and unit trips in some cases. Off-line washing is more effective at cleaning the unit, but requires the unit to be shut down for extended periods of time. Air filtration can help prevent foreign particles from entering the unit, but higher efficiency filters are generally associated with a larger inlet pressure drop, leading to decreased unit output; this is balanced against reduced fouling rates. These tradeoffs between the costs associated with higher efficiency filters and the frequency of compressor washing need to be evaluated on a plant-by-plant basis to determine the best combination of air filtration and compressor washing programs. This paper presents a field study carried out to determine the effectiveness of high efficiency filters in preventing compressor fouling. Fourteen units at four sites were monitored over a 9 month to 3 year time period to determine the changes in unit performance and the impact of water washes on unit performance for both pre and final filters of lower and higher efficiency ratings. Results to date indicate that higher efficiency filters are effective at reducing the need for off-line water washes and potentially reduce life-cycle cost. Reduced output from the higher pressure drop, high efficiency filters is offset by the better performance retention offered from reduced fouling rates.


Author(s):  
Fabrice Giuliani ◽  
Vanessa Moosbrugger ◽  
Markus Stuetz ◽  
Thomas Leitgeb-Simandl

The purpose of this work is to develop a new combustion technology to reduce the operation costs of thermal systems that burn low heat value gases. Landfill methane emission is a greenhouse gas source which can be defined and reduced. Landfill managing companies in Austria have adapted the latest regulations on methane emissions primarily by collecting and flaring off landfill gas, sometimes with energy recovery. Their concern is related to long-term landfills where the methane concentration by volume falls well below 20%. The costs to flare-off these gases are mostly driven by the use of support fuel to ensure combustion. A technical solution using the programme MethaNull (to approach zero methane emissions) is proposed to extend the combustion domain of gases with low heat value so that the amount of support fuel can be significantly reduced. This solution should fit a large range of LHV gases, for combustion at ambient conditions as well as under pressure at elevated inlet temperature conditions. The process has similarities with pulse combustion, where the combustion process benefits from a higher energy density and better heat transfer rates. As the forced pulsation is generated by a separate module, the methodology can be easily adapted or retrofitted for existing facilities. This paper covers the MethaNull programme, the burner design, the flow pulsation technology and its operation. A systematic comparison between steady state and oscillating combustion is presented.


Author(s):  
Panagiotis Stathopoulos ◽  
Christian Oliver Paschereit

The simultaneous expansion of variable renewables and combined heat and power (CHP) plants in Europe has given rise to a discussion about their compatibility. Due to the concurrence of high wind power generation and high heating loads, it has been argued that only the flexible, electricity oriented operation of CHP plants could go along with the extended penetration of renewables in the European energy system. The current work focuses on the wet cycle simulation of a Turbec T-100. Three operational strategies are applied on the heat and electricity demand data of a public building, to assess the economic and environmental performance of the wet cycle. The operation of the mGT is modeled in ASPEN Plus and the model is validated with data found in literature. The economic aspects of the operational strategies are assessed with a financial model, which takes into account the current CHP policy incentives and price levels. Furthermore, the advantages and drawbacks of wet operation are highlighted by its comparison to the typical heat-driven operation of dry-cycle mGTs, with a reference to the same case study. It is shown that the wet cycle turbines have a higher number of full load equivalent operating hours and can achieve higher investment payback, with minor drawbacks to their overall environmental performance.


Sign in / Sign up

Export Citation Format

Share Document