scholarly journals Measurement of the retinal venous pressure with a new instrument in healthy subjects

Author(s):  
Richard Stodtmeister ◽  
Emilie Wetzk ◽  
Robert Herber ◽  
Karin R. Pillunat ◽  
Lutz E. Pillunat

Abstract Background The retinal venous pressure (RVP) is a determining factor for the blood supply of the retina as well as the optic nerve head and until recently has been measured by contact lens dynamometry (CLD). A new method has been developed, potentially offering better acceptance. The applicability and the results of both methods were compared. Methods The type of this study is cross sectional. The subjects were 36 healthy volunteers, age 26 ± 5 years (mean ± s). Tonometry: rebound tonometer (RT) (iCare). The measurements were performed during an increase in airway pressure of 20 mmHg (Valsalva manoeuvre). Principle of RVP measurement: the central retinal vein (CRV) is observed during an increase of intraocular pressure (IOP) and at the start of pulsation, which corresponds with the RVP. Two different instruments for the IOP enhancement where used: contact lens dynamometry and the new instrument, IOPstim. Principle: a deflated balloon of 8 mm diameter—placed on the sclera laterally of the cornea—is filled with air. As soon as a venous pulsation occurs, filling is stopped and the IOP is measured, equalling the RVP. Examination procedure: randomization of the sequence: CLD or IOPstim, IOP, mydriasis, IOP three single measurements (SM) of the IOP with RT or of the pressure increase with CLD at an airway pressure of 20 mmHg, 5 min break, IOP, and three SM using the second method at equal pressure (20 mmHg). Results Spontaneous pulsation of the CRV was present in all 36 subjects. Pressures are given in mmHg. IOP in mydriasis 15.6 ± 3.3 (m ± s). Median RVP (MRVP)) of the three SM: CLD/IOPstim, 37.7 ± 5.2/24.7 ± 4.8 (t test: p < 0.001). Range of SM: 3.2 ± 1.8/2.9 ± 1.3 (t test: p = 0.36). Intraclass correlation coefficient (ICC) of SM: 0.88/0.83. ANOVA in SM: p = 0.48/0.08. MRVP CLD minus MRVP IOPstim: 13.0 ± 5.6. Ratio MRVP CLD/MRVP IOPstim: 1.56 ± 3.1. Cooperation and agreeability were slightly better with the IOPstim. Conclusion This first study with the IOPstim in humans was deliberately performed in healthy volunteers using Valsalva conditions. As demonstrated by ICC and ANOVA, reproducible SM can be obtained by both methods and the range of the SM does not differ greatly. The higher MRVP in CLD could be explained by the different directions of the force vectors.

2017 ◽  
Vol 96 (1) ◽  
pp. e68-e73 ◽  
Author(s):  
Richard Stodtmeister ◽  
Maria Heyde ◽  
Sylvana Georgii ◽  
Egbert Matthè ◽  
Eberhard Spoerl ◽  
...  

2021 ◽  
Author(s):  
Anna Marchetti ◽  
Marzia Lommi ◽  
Claudio Barbaranelli ◽  
Michela Piredda ◽  
Maria Grazia De Marinis ◽  
...  

Abstract Background and Objectives Ageism toward older adults, prevalent in contemporary societies, seems to be internalized during childhood and consolidated during adolescence. Although several instruments have been developed to measure adolescents’ ageism, they present a number of limitations. The study aimed at developing a new instrument, the Adolescents’ Ageism Toward Older Adults Scale, and testing its psychometric properties. Research Design and Methods A 3-phase process was followed: the instrument’s items were developed empirically from focus groups of adolescents; its content validity was evaluated; and finally, its psychometric properties were tested through a multicenter cross-sectional study involving 575 adolescents. Results Exploratory factor analysis of the new scale retained 33 items grouped into six factors: Moodiness, Traditionalism, Physical deterioration, Anti-technologism, Sageness and Sociability. Confirmatory factor analysis evidenced a second-order factor structure. Omega coefficients measuring internal consistency were above the cut-off of 0.60 for the six factors except for Anti-technologism. Intraclass correlation coefficients for the entire scale and for the six factors were greater than 0.70, again excepting Anti-technologism. Discussion and implications The Adolescents’ Ageism Toward Older Adults Scale is a promising measure of adolescents’ negative and positive attitudes toward older adults. Its validation highlighted some criticalities that can be resolved by a few modifications. Further testing of the scale should be conducted after these modifications.


Author(s):  
Richard Stodtmeister ◽  
Wiebke Koch ◽  
Sylvana Georgii ◽  
Karin R. Pillunat ◽  
Eberhard Spörl ◽  
...  

Abstract Introduction Until now, venous pressure within the eye has widely been equated with intraocular pressure (IOP). Measurements with dynamometers calibrated in instrument units or in force showed that the retinal venous pressure (RVP) may be higher than the IOP in glaucoma patients. In this study, the RVP was measured with a contact lens dynamometer calibrated in mmHg. Methods Study type: cross-sectional. Subjects: Fifty consecutive patients with primary open-angle glaucoma (POAG) who underwent diurnal curve measurement under medication. Age: 69 ± 8 years. Measurement of RVP: contact lens dynamometry. IOP measurement: dynamic contour tonometry. Results Pressures are given in mmHg. In all 50 patients, the IOP was 15.9 (13.6; 17.1) [median (Q1; Q3)], and the RVP was 17.4 (14.8; 27.2). The distribution of the IOP was normal and that of the RVP was right skewed. In the subgroup of 34 patients with spontaneous pulsation of the central retinal vein (SVP), the IOP and therefore, by definition, the RVP was 16.5 (13.7; 17.4). In the subgroup of 16 patients without SVP, the IOP was 14.8 (13.3; 16.4), and the RVP was 31.3 (26.2; 38.8) (p ≤ 0.001). In systemic treatment, the prescribed drugs were (the number of patients is given in parentheses): ACE inhibitors (20), β-blockers (17), angiotensin II-receptor blockers (13), calcium channel blockers (12), diuretics (7). No difference in RVP was observed between patients receiving these drugs and not receiving them, except in the β-blocker group. Here, the 17 patients with systemic β-blockers had a median RVP of 15.6 mmHg and without 20.2 mmHg (p = 0.003). In the 16 patients with a higher RVP than IOP, only one patient received a systemic β-blocker. The median IOP was 15.7 mmHg with systemic β-blockers and 16.1 mmHg without (p = 0.85). Conclusion In a subgroup of 16 of the 50 patients studied, the RVP was greater than the IOP by a highly statistically and clinically significant degree. According to the widely accepted thinking on the pathophysiology of retinal and optic nerve head circulation, the blood flow in these tissues may be much more compromised in this group of patients than has been assumed. They may be identified by a missing SVP. Topical and systemic medications showed no statistically significant influence on the RVP, except for the systemic β-blockers, in which the RVP was lower by 4.6 mmHg than for the patients who did not receive these drugs (p = 0.003).


2020 ◽  
Vol 258 (11) ◽  
pp. 2419-2424 ◽  
Author(s):  
Sofie Heimann ◽  
Richard Stodtmeister ◽  
Lutz E. Pillunat ◽  
Naim Terai

2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Gonzalo Carracedo ◽  
Carlos Carpena-Torres ◽  
Cristina Pastrana ◽  
Ana Privado-Aroco ◽  
María Serramito ◽  
...  

Purpose. To compare the intersession repeatability of the Eye Refract, a new instrument to perform aberrometry-based automated subjective refraction, on healthy and keratoconus subjects. Materials and Methods. A cross-sectional and randomized study was performed. A total of 64 participants were evaluated in the study, selecting one eye per participant randomly. The sample was divided into two different groups: 33 healthy subjects (38.85 ± 13.21 years) and 31 with keratoconus (37.29 ± 11.37 years). Three refractions per participant with the Eye Refract were performed on three different days, without cycloplegia. The repeatability analysis of refractive variables (M, J0, and J45), binocular corrected distance visual acuity (BCDVA), and spent time in refraction was performed in terms of repeatability (Sr), its 95% confidence interval (r), and intraclass correlation coefficient (ICC). Results. There were no statistically significant differences ( P ≥ 0.05 ) between sessions in both groups for all refractive variables (M, J0, and J45) and BCDVA. Spent time in refraction was reduced as the sessions went by ( P < 0.05 ). The Eye Refract was more repeatable for refractive errors assessment in healthy subjects (M : Sr = 0.27 D; J0 : Sr = 0.09 D; J45 : Sr = 0.06 D) compared to those with keratoconus (M : Sr = 0.65 D; J0 : Sr = 0.29 D; J45 : Sr = 0.24 D), while it was similar for BCDVA. Conclusions. The Eye Refract offered better repeatability to assess refractive errors in healthy subjects compared to those with keratoconus. Despite measurements being also consistent in keratoconus subjects, they should be treated with caution in clinical practice.


2018 ◽  
Vol 314 (3) ◽  
pp. R377-R385 ◽  
Author(s):  
P. Holmlund ◽  
A. Eklund ◽  
L.-O. D. Koskinen ◽  
E. Johansson ◽  
N. Sundström ◽  
...  

Recent interest in intracranial pressure (ICP) in the upright posture has revealed that the mechanisms regulating postural changes in ICP are not fully understood. We have suggested an explanatory model where the postural changes in ICP depend on well-established hydrostatic effects in the venous system and where these effects are interrupted by collapse of the internal jugular veins (IJVs) in more upright positions. The aim of this study was to investigate this relationship by simultaneous invasive measurements of ICP, venous pressure, and IJV collapse in healthy volunteers. ICP (monitored via the lumbar route), central venous pressure (peripherally inserted central catheter line), and IJV cross-sectional area (ultrasound) were measured in 11 healthy volunteers (47 ± 10 yr, mean ± SD) in 7 positions, from supine to sitting (0–69°). Venous pressure and anatomical distances were used to predict ICP in accordance with the explanatory model, and IJV area was used to assess IJV collapse. The hypothesis was tested by comparing measured ICP with predicted ICP. Our model accurately described the general behavior of the observed postural ICP changes (mean difference, −0.03 ± 2.7 mmHg). No difference was found between predicted and measured ICP for any tilt angle ( P values, 0.65–0.94). The results support the hypothesis that postural ICP changes are governed by hydrostatic effects in the venous system and IJV collapse. This improved understanding of postural ICP regulation may have important implications for the development of better treatments for neurological and neurosurgical conditions affecting ICP.


Author(s):  
Fatih Öner Kaya ◽  
Yeşim Ceylaner ◽  
Belkız Öngen İpek ◽  
Zeynep Güneş Özünal ◽  
Gülbüz Sezgin ◽  
...  

Aims: The etiopathogenesis of Rheumatoid Arthritis (RA) is not clearly understood. However, the role of the cytokines takes an important part in this mechanism. We aimed to bring a new approach to the concept of 'remission' in patients with RA. Background: RA is a chronic, autoimmune, inflammatory disease that involves small joints in the form of symmetrical polyarthritis and progresses with exacerbations and remissions. Pain, swelling, tenderness and morning stiffness are typical of the joints involved. Although it is approached as a primary joint disease, a wide variety of extra-articular involvements may also occur. It is an interesting pathophysiological process, the exact cause of which is still unknown, with many environmental, genetic and potentially undiscovered possible factors in a chaotic manner. Objective: In this cross-sectional study, sedimentation rate (ESR), C- Reactive protein (CRP), Tumor necrosis factor (TNF)-α, soluble-TNF-α receptor (TNF-R), Interleukin (IL)-1B and IL-10 were measured in three groups which were healthy volunteers, patients with RA in the active period, and patients with RA in remission. Disease activity score-28 (DAS-28) was calculated in active RA and RA in remission. Methods: This study included 20 healthy volunteers, 20 remission patients with RA and 20 active RA patients. Venous blood samples were collected from patients in both healthy and RA groups. Results: RA group consisted 43 (71.6%) female and 17 (28.4%) male. Control group consisted 11 (55%) female and 9 (45%) male. TNF-R was significantly high only in the active group according to the healthy group (p=0.002). IL-10 was significantly high in active RA according to RA in remission (p=0.03). DAS-28 was significantly high in active RA according to RA in remission (p=0.001). In the active RA group, ESR and TNF-R had a positive correlation (r:0.442; p=0.048). In the active RA group, there was also a positive correlation between TNF-R and CRP (r:0.621; p=0,003). Both healthy and active RA group had significant positive correlation between ESR and CRP (r: 0.481; p=0.032 and r: 0,697; p=0,001 respectively). Conclusion: TNF-R can be the main pathophysiological factor and a marker showing activation. TNF-R can be very important in revealing the effect of TNF on the disease and the value of this effect in the treatment and ensuring the follow-up of the disease with CRP instead of ESR in activation.


Author(s):  
Alex Bató ◽  
Valentin Brodszky ◽  
L. Hunor Gergely ◽  
Krisztián Gáspár ◽  
Norbert Wikonkál ◽  
...  

Abstract Purpose Hidradenitis suppurativa (HS) is a chronic inflammatory skin disease that affects up to 1% of the population in Europe. The EQ-5D is the most commonly used generic instrument for measuring health-related quality of life among HS patients. This study aims to compare the measurement properties of the two adult versions of EQ-5D (EQ-5D-3L and EQ-5D-5L) in patients with HS. Methods We recruited 200 consecutive patients with HS (mean age 37 years, 38% severe or very severe HS) to participate in a multicentre cross-sectional survey. Patients completed the EQ-5D-3L, EQ-5D-5L, Dermatology Life Quality Index (DLQI) and Skindex-16 questionnaires. Results More than twice as many different health state profiles occurred in the EQ-5D-5L compared to the EQ-5D-3L (101 vs. 43). A significant reduction in ceiling effect was found for the mobility, self-care and usual activities dimensions. A good agreement was established between the EQ-5D-3L and EQ-5D-5L with an intraclass correlation coefficient of 0.872 (95% CI 0.830–0.903; p < 0.001) that was confirmed by a Bland-Altman plot. EQ-5D-5L improved both the absolute and relative informativity in all dimensions except for anxiety/depression. EQ-5D-3L and EQ-5D-5L demonstrated similar convergent validity with DLQI and Skindex-16. EQ-5D-5L was able to better discriminate between known groups of patients based on the number of comorbidities and disease severity (HS-Physician's Global Assessment). Conclusion In patients with HS, the EQ-5D-5L outperformed the EQ-5D-3L in feasibility, ceiling effects, informativity and known-groups validity for many important clinical characteristics. We recommend using the EQ-5D-5L in HS patients across various settings, including clinical care, research and economic evaluations.


2020 ◽  
Vol 11 (05) ◽  
pp. 769-784
Author(s):  
Ipek Ensari ◽  
Adrienne Pichon ◽  
Sharon Lipsky-Gorman ◽  
Suzanne Bakken ◽  
Noémie Elhadad

Abstract Background Self-tracking through mobile health technology can augment the electronic health record (EHR) as an additional data source by providing direct patient input. This can be particularly useful in the context of enigmatic diseases and further promote patient engagement. Objectives This study aimed to investigate the additional information that can be gained through direct patient input on poorly understood diseases, beyond what is already documented in the EHR. Methods This was an observational study including two samples with a clinically confirmed endometriosis diagnosis. We analyzed data from 6,925 women with endometriosis using a research app for tracking endometriosis to assess prevalence of self-reported pain problems, between- and within-person variability in pain over time, endometriosis-affected tasks of daily function, and self-management strategies. We analyzed data from 4,389 patients identified through a large metropolitan hospital EHR to compare pain problems with the self-tracking app and to identify unique data elements that can be contributed via patient self-tracking. Results Pelvic pain was the most prevalent problem in the self-tracking sample (57.3%), followed by gastrointestinal-related (55.9%) and lower back (49.2%) pain. Unique problems that were captured by self-tracking included pain in ovaries (43.7%) and uterus (37.2%). Pain experience was highly variable both across and within participants over time. Within-person variation accounted for 58% of the total variance in pain scores, and was large in magnitude, based on the ratio of within- to between-person variability (0.92) and the intraclass correlation (0.42). Work was the most affected daily function task (49%), and there was significant within- and between-person variability in self-management effectiveness. Prevalence rates in the EHR were significantly lower, with abdominal pain being the most prevalent (36.5%). Conclusion For enigmatic diseases, patient self-tracking as an additional data source complementary to EHR can enable learning from the patient to more accurately and comprehensively evaluate patient health history and status.


Sign in / Sign up

Export Citation Format

Share Document