scholarly journals An advanced method to design graded cylindrical scaffolds with versatile effective cross-sectional mechanical properties

Author(s):  
K. Cheikho ◽  
C. Laurent ◽  
J.F. Ganghoffer
Materials ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2367
Author(s):  
Junhyuk Son ◽  
Dong-Yurl Yu ◽  
Yun-Chan Kim ◽  
Shin-Il Kim ◽  
Min-Su Kim ◽  
...  

In this study, the interfacial reactions and mechanical properties of solder joints after multiple reflows were observed to evaluate the applicability of the developed materials for high-temperature soldering for automotive electronic components. The microstructural changes and mechanical properties of Sn-Cu solders regarding Al(Si) addition and the number of reflows were investigated to determine their reliability under high heat and strong vibrations. Using differential scanning calorimetry, the melting points were measured to be approximately 227, 230, and 231 °C for the SC07 solder, SC-0.01Al(Si), and SC-0.03Al(Si), respectively. The cross-sectional analysis results showed that the total intermetallic compounds (IMCs) of the SC-0.03Al(Si) solder grew the least after the as-reflow, as well as after 10 reflows. Electron probe microanalysis and transmission electron microscopy revealed that the Al-Cu and Cu-Al-Sn IMCs were present inside the solders, and their amounts increased with increasing Al(Si) content. In addition, the Cu6Sn5 IMCs inside the solder became more finely distributed with increasing Al(Si) content. The Sn-0.5Cu-0.03Al(Si) solder exhibited the highest shear strength at the beginning and after 10 reflows, and ductile fracturing was observed in all three solders. This study will facilitate the future application of lead-free solders, such as an Sn-Cu-Al(Si) solder, in automotive electrical components.


2005 ◽  
Vol 475-479 ◽  
pp. 1533-1536
Author(s):  
Liu Ding Tang ◽  
Xue Bin Zhang ◽  
Bing Zhe Li

Based on equivalent transformation by means of mathematically rigorous analytics, the stress analysis of heavy cross-sectional, non-homogeneous Functionally Graded Composites (FGCs) has been performed by the layering calculation model in axis-symmetrical mechanics problems. The partially calculated results of the non-homogeneous layered thick-walled metal tube are similar to the design and practice of machine forging moulds manufactured with special welding electrodes developed by the German Capilla Company. The analysis is used complementary to the investigation of the quantitative analysis of thermo-mechanical properties, or the so-called anti-design and the optimization of the graded structure for FGCs.


2008 ◽  
Vol 130 (2) ◽  
Author(s):  
K. L. Goh ◽  
D. F. Holmes ◽  
H.-Y. Lu ◽  
S. Richardson ◽  
K. E. Kadler ◽  
...  

Connective tissues are biological composites comprising of collagen fibrils embedded in (and reinforcing) the hydrated proteoglycan-rich (PG) gel within the extracellular matrices (ECMs). Age-related changes to the mechanical properties of tissues are often associated with changes to the structure of the ECM, namely, fibril diameter. However, quantitative attempts to correlate fibril diameter to mechanical properties have yielded inconclusive evidence. Here, we described a novel approach that was based on the rule of mixtures for fiber composites to evaluate the dependence of age-related changes in tendon tensile strength (σ) and stiffness (E) on the collagen fibril cross-sectional area fraction (ρ), which is related to the fibril volume fraction. Tail tendons from C57BL6 mice from age groups 1.6–35.3months old were stretched to failure to determine σ and E. Parallel measurements of ρ as a function of age were made using transmission electron microscopy. Mathematical models (rule of mixtures) of fibrils reinforcing a PG gel in tendons were used to investigate the influence of ρ on ageing changes in σ and E. The magnitudes of σ, E, and ρ increased rapidly from 1.6monthsto4.0months (P-values <0.05) before reaching a constant (age independent) from 4.0monthsto29.0months (P-values >0.05); this trend continued for E and ρ (P-values >0.05) from 29.0monthsto35.3months, but not for σ, which decreased gradually (P-values <0.05). Linear regression analysis revealed that age-related changes in σ and E correlated positively to ρ (P-values <0.05). Collagen fibril cross-sectional area fraction ρ is a significant predictor of ageing changes in σ and E in the tail tendons of C57BL6 mice.


2010 ◽  
Vol 638-642 ◽  
pp. 675-680 ◽  
Author(s):  
Martina Thomann ◽  
Nina von der Höh ◽  
Dirk Bormann ◽  
Dina Rittershaus ◽  
C. Krause ◽  
...  

Current research focuses on magnesium based alloys in the course of searching a resorbable osteosynthetic material which provides sufficient mechanical properties besides a good biocompatibility. Previous studies reported on a favorable biocompatibility of the alloys LAE442 and MgCa0.8. The present study compared the degradation process of cylindrical LAE442 and MgCa0.8 implants after 12 months implantation duration. Therefore, 10 extruded implants (2.5 x 25 mm, cross sectional area 4.9 mm²) of both alloys were implanted into the medullary cavity of both tibiae of rabbits for 12 months. After euthanization, the right bone-implant-compound was scanned in a µ-computed tomograph (µCT80, ScancoMedical) and nine uniformly distributed cross-sections of each implant were used to determine the residual implants´ cross sectional area (Software AxioVisionRelease 4.5, Zeiss). Left implants were taken out of the bone carefully. After weighing, a three-point bending test was carried out. LAE442 implants degraded obviously slower and more homogeneously than MgCa0.8. The mean residual cross sectional area of LAE442 implants was 4.7 ± 0.07 mm². MgCa0.8 showed an area of only 2.18 ± 1.03 mm². In contrast, the loss in volume of LAE442 pins was more obvious. They lost 64 % of their initial weight. The volume of MgCa0.8 reduced clearly to 54.4 % which corresponds to the cross sectional area results. Three point bending tests revealed that LAE442 showed a loss in strength of 71.2 % while MgCa0.8 lost 85.6 % of its initial strength. All results indicated that LAE442 implants degraded slowly, probably due to the formation of a very obvious degradation layer. Degradation of MgCa0.8 implants was far advanced.


2018 ◽  
Vol 2018 ◽  
pp. 1-12 ◽  
Author(s):  
Hui Chen ◽  
Jinjin Zhang ◽  
Jin Yang ◽  
Feilong Ye

The tensile behaviors of corroded steel bars are important in the capacity evaluation of corroded reinforced concrete structures. The present paper studies the mechanical behavior of the corroded high strength reinforcing steel bars under static and dynamic loading. High strength reinforcing steel bars were corroded by using accelerated corrosion methods and the tensile tests were carried out under different strain rates. The results showed that the mechanical properties of corroded high strength steel bars were strain rate dependent, and the strain rate effect decreased with the increase of corrosion degree. The decreased nominal yield and ultimate strengths were mainly caused by the reduction of cross-sectional areas, and the decreased ultimate deformation and the shortened yield plateau resulted from the intensified stress concentration at the nonuniform reduction. Based on the test results, reduction factors were proposed to relate the tensile behaviors with the corrosion degree and strain rate for corroded bars. A modified Johnson-Cook strength model of corroded high strength steel bars under dynamic loading was proposed by taking into account the influence of corrosion degree. Comparison between the model and test results showed that proposed model properly describes the dynamic response of the corroded high strength rebars.


2008 ◽  
Vol 105 (3) ◽  
pp. 805-810 ◽  
Author(s):  
C. Couppé ◽  
M. Kongsgaard ◽  
P. Aagaard ◽  
P. Hansen ◽  
J. Bojsen-Moller ◽  
...  

The purpose of this study was to examine patellar tendon (PT) size and mechanical properties in subjects with a side-to-side strength difference of ≥15% due to sport-induced loading. Seven elite fencers and badminton players were included. Cross-sectional area (CSA) of the PT obtained from MRI and ultrasonography-based measurement of tibial and patellar movement together with PT force during isometric contractions were used to estimate mechanical properties of the PT bilaterally. We found that distal tendon and PT, but not mid-tendon, CSA were greater on the lead extremity compared with the nonlead extremity (distal: 139 ± 11 vs. 116 ± 7 mm2; mid-tendon: 85 ± 5 vs. 77 ± 3 mm2; proximal: 106 ± 7 vs. 83 ± 4 mm2; P < 0.05). Distal tendon CSA was greater than proximal and mid-tendon CSA on both the lead and nonlead extremity ( P < 0.05). For a given common force, stress was lower on the lead extremity (52.9 ± 4.8 MPa) compared with the nonlead extremity (66.0 ± 8.0 MPa; P < 0.05). PT stiffness was also higher in the lead extremity (4,766 ± 716 N/mm) compared with the nonlead extremity (3,494 ± 446 N/mm) ( P < 0.05), whereas the modulus did not differ (lead 2.27 ± 0.27 GPa vs. nonlead 2.16 ± 0.28 GPa) at a common force. These data show that a habitual loading is associated with a significant increase in PT size and mechanical properties.


2007 ◽  
Vol 330-332 ◽  
pp. 907-910
Author(s):  
Fa Ming Zhang ◽  
Jiang Chang ◽  
Jian Xi Lu ◽  
Kai Li Lin

Attempt to increase the mechanical properties of porous bioceramics, a dense/porous structured β-TCP bioceramics that mimic the characteristics of nature bone were fabricated. Experimental results show that the dense/porous structured β-TCP bioceramics demonstrated excellent mechanical properties with compressive strength up to 74 MPa and elastic modulus up to 960 MPa, which could be tailored by the dense/porous cross-sectional area ratio obeying the rule of exponential growth. The interface between the dense and porous bioceramics is connected compactly and tightly with some micropores distributed in the matrix of both porous and dense counterparts. The dense/porous structure of β-TCP bioceramics may provide an effective way to increase the mechanical properties of porous bioceramics for bone regeneration at weight bearing sites.


2021 ◽  
Vol 30 ◽  
pp. 263498332110061
Author(s):  
Gunyong Hwang ◽  
Dong Hyun Kim ◽  
Myungsoo Kim

This research aims to optimize the mechanical properties of woven fabric composites, especially the elastic modulus. A micromechanics model of woven fabric composites was used to obtain the mechanical properties of the fiber composite, and a genetic algorithm (GA) was employed for the optimization tool. The structure of the fabric fiber was expressed using the width, thickness, and wave pattern of the fiber strands in the woven fabric composites. In the GA, the chromosome string consisted of the thickness and width of the fill and warp strands, and the objective function was determined to maximize the elastic modulus of the composite. Numerical analysis showed that the longitudinal mechanical properties of the strands contributed significantly to the overall elastic modulus of the composites because the longitudinal property was notably larger than the transverse property. Therefore, to improve the in-plane elastic modulus, the resulting geometry of the composites possessed large volumes of related strands with large cross-sectional areas and small strand waviness. However, the numerical results of the out-of-plane elastic modulus generated large strand waviness, which contributed to the fiber alignment in the out-of-plane direction. The findings of this research are expected to be an excellent resource for the structural design of woven fabric composites.


2009 ◽  
Vol 22 (03) ◽  
pp. 210-215 ◽  
Author(s):  
C.A. Phillips ◽  
S.A. Fernandez ◽  
Y. Li ◽  
S.S. Huja

Summary Objectives: The purpose of this study was to quantify the tissue level mechanical properties of cortical bone of skeletally immature (~five-month-old) Beagle dogs and compare them to data from mature dogs measured in a previous study. Methods: Eight femoral cross sectional specimens (two bone sections / dog) were obtained from four skeletally immature dogs. A pair of calcein bone labels were administered intravenously to the dogs to mark sites of active mineralization prior to euthanasia. Prepared bone specimens were placed in a nanoindenter specimen holder and the previously identified calcein labelled osteons were located. Labelled (n = 128) and neighbouring unlabelled (n = 127) osteons in skeletally immature femurs were examined by instrumented indentation testing. Indents were made to a depth of 500 nm at a loading rate of 10 nm/s. Indentation modulus (IM) and hardness (H) were obtained. Results: The overall IM of the cortical bone in the skeletally mature groups was significantly greater than in the immature group (p = 0.0011), however overall H was not significantly different. The differences between the groups in IM were significant for the unlabelled osteons (p = 0.001), but not for the labelled osteons (p = 0.56). Conclusion: There are differences in the IM of unlabelled osteons in skeletally immature and mature groups of Beagle dogs. In contrast to whole bone mechanical tests, where there are obvious differences between growing and mature bones, there are only small differences in the micro-mechanical properties.


Sign in / Sign up

Export Citation Format

Share Document