scholarly journals Eye lens radiation exposure in paediatric interventional treatment of retinoblastoma

2019 ◽  
Vol 9 (1) ◽  
Author(s):  
A. Obesso ◽  
L. Alejo ◽  
C. Huerga ◽  
F. Sánchez-Muñoz ◽  
E. Corredoira ◽  
...  

AbstractRetinoblastoma represents 3% of cancers in children under fifteen years of age. The standard paediatric treatment for saving the affected eye is supraselective intra-arterial chemotherapy performed in interventional rooms. In order to address the radiation toxicity due to the angiography, the aim of this study was to determine the typical dose value corresponding to the procedure, estimate the paediatric patients’ eye lens dose and study the relationship between dose indicators and dose to the lens. An automatic dose management software was installed in two interventional rooms to obtain the distribution of the dose indicators kerma-area product and reference-point air kerma, getting a typical value 16 Gy·cm2 and 130 mGy, respectively (n = 35). The eye lens dose estimates were obtained with photoluminescent dosimeters placed on the patient’s eyelids. In the left eye, the entrance surface air kerma was 44.23 ± 2.66 mGy, and 12.72 ± 0.89 mGy in the right eye (n = 10). There was a positive correlation between dose to the lens per procedure and dose indicators, with R2 > 0.65 for both eyes. Based on this information, the threshold for the onset of radiation-induce cataracts (500 mGy) will be exceeded if the treatment is performed for more than 8 sessions.

2021 ◽  
Author(s):  
Ibrahim Idris Suliman

Abstract An online method is proposed to determine the entrance surface air kerma (ESAK) in digital radiology from console-displayed kerma area product (PKA) data. ESAK values were calculated from X-ray tube outputs and patient exposure factors across five X-ray examinations. The corresponding PKAvalues were taken from the Digital Imaging and Communications in Medicine (DICOM) header. Using linear regression between ESAK and values, the slope and intercept coefficients for each type of X-ray equipment and procedure were determined. The coefficient to determine ESAK from ranged from 59% for a posteroanterior chest to 88% for anteroposterior lumbar spine view X-ray procedures. The results demonstrated the possibility of online estimates of ESAK from a console that displayed using readily available digital information in radiology. The results may have important implications in interventional radiology, where ESAK values are crucial for preventing skin injuries due to prolonged fluoroscopy times.


Diagnostics ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 150
Author(s):  
Kosuke Matsubara ◽  
Sayu Yoshida ◽  
Ayaka Hirosawa ◽  
Thunyarat Chusin ◽  
Yasushi Furukawa

This study aimed to evaluate the property of small dosimeters used for measuring eye lens doses for medical staff during fluoroscopic examination. Dose linearity, energy dependence, and directional dependence of scattered X-rays were evaluated for small radiophotoluminescence glass dosimeters (RPLDs), those with a tin filter (Sn-RPLDs), and small optically stimulated luminescence dosimeters (OSLDs). These dosimeters were pasted on radioprotective glasses, and accumulated air kerma was obtained after irradiating the X-rays to a patient phantom. Strong correlations existed between fluoroscopic time and accumulated air kerma in all types of dosimeters. The energy dependence of Sn-RPLD and OSLD was smaller than that of RPLD. The relative dose value of the OSLD gradually decreased as the angle of the OSLD against the scattered X-rays was larger or lower than the right angle in the horizontal direction. The ranges of relative dose values of RPLD and Sn-RPLD were larger than that of OSLD in the vertical direction. The OSLDs showed lower doses than the RPLDs and Sn-RPLDs, especially on the right side of the radioprotective glasses. These results showed that RPLDs, Sn-RPLDs, and OSLDs had different dosimeter properties, and influence measured eye lens doses for the physician, especially on the opposite side of the patient.


2019 ◽  
Vol 186 (2-3) ◽  
pp. 391-396 ◽  
Author(s):  
Kateřina Chytrá ◽  
Leoš Novák ◽  
Pavel Rejtar ◽  
Martin Homola ◽  
Kateřina Daníčková ◽  
...  

Abstract The pilot dose survey on paediatric general radiography, fluoroscopy and CT procedures was performed in four university hospitals. The analysis of data was focused on the radiography and CT imaging of head, chest, abdomen, pelvis and spine and fluoroscopic procedures of gastrointestinal and urinary tracts. The survey was conducted by the National Radiation Protection Institute. Two hospitals exported data from the patient dose management system, while the others collected the data manually. The methodology of diagnostic reference levels assessment was proposed and tested. Local diagnostic reference levels were calculated in terms of air kerma-area product $P_{KA}$, CT air kerma-length product $P_{KL,CT}$ and volumetric CT air kerma index $C_{VOL}$. The lack of procedure standardisation, e.g. in tube voltage setting irrespective of patient’s weight, was revealed at one hospital. Dose and exposure parameters distributions with respect to patient’s anatomical constitution are presented in this article. In future, this pilot study will be a base for national survey of paediatric diagnostic reference levels.


2014 ◽  
Vol 29 (3) ◽  
pp. 220-225 ◽  
Author(s):  
Aleksandra Milatovic ◽  
Vesna Spasic-Jokic ◽  
Slobodan Jovanovic

Investigations presented in this paper represent the first estimation of patient doses in chest radiography in Montenegro. In the initial stage of our study, we measured the entrance surface air kerma and kerma area product for chest radiography in five major health institutions in the country. A total of 214 patients were observed. We reported the mean value, minimum and third quartile values, as well as maximum values of surface air kerma and kerma area product of patient doses. In the second stage, the possibilities for dose reduction were investigated. Mean kerma area product values were 0.8 ? 0.5 Gycm2 for the posterior-anterior projection and 1.6 ? 0.9 Gycm2 for the lateral projection. The max/min ratio for the entrance surface air kerma was found to be 53 for the posterior-anterior projection and 88 for the lateral projection. Comparing the results obtained in Montenegro with results from other countries, we concluded that patient doses in our medical centres are significantly higher. Changes in exposure parameters and increased filtration contributed to a dose reduction of up to 36% for posterior-anterior chest examinations. The variability of the estimated dose values points to a significant space for dose reduction throughout the process of radiological practice optimisation.


2015 ◽  
Vol 8 (7) ◽  
pp. 736-740 ◽  
Author(s):  
Marta Sans Merce ◽  
Amine M Korchi ◽  
Lisa Kobzeva ◽  
Jérôme Damet ◽  
Gorislav Erceg ◽  
...  

BackgroundProtection of the head and eyes of the neurointerventional radiologist is a growing concern, especially after recent reports on the incidence of brain cancer among these personnel, and the revision of dose limits to the eye lens. The goal of this study was to determine typical occupational dose levels and to evaluate the efficiency of non-routine radiation protective gear (protective eyewear and cap). Experimental correlations between the dosimetric records of each measurement point and kerma area product (KAP), and between whole body doses and eye lens doses were investigated.MethodsMeasurements were taken using thermoluminescent dosimeters placed in plastic bags and worn by the staff at different places. To evaluate the effective dose, whole body dosimeters (over and under the lead apron) were used.ResultsThe mean annual effective dose was estimated at 0.4 mSv. Annual eye lens exposure was estimated at 17 mSv when using a ceiling shield but without protective glasses. The protective glasses reduced the eye lens dose by a factor of 2.73. The mean annual dose to the brain was 12 mSv; no major reduction was observed when using the cap. The higher correlation coefficients with KAP were found for the dosimeters positioned between the eyes (R2=0.84) and above the apron, and between the eye lens (R2=0.85) and the whole body.ConclusionsUnder the specific conditions of this study, the limits currently applicable were respected. If a new eye lens dose limit is introduced, our results indicate it could be difficult to comply with, without introducing additional protective eyewear.


2018 ◽  
Vol 6 (3) ◽  
Author(s):  
Wilson Otto Gomes Batista ◽  
Alexandre Gomes De Carvalho

Contrast-detail (C-D) curves are useful in evaluating the radiographic image quality in a global way. The objective of the present study was to obtain the C-D curves and the inverse image quality figure. Both of these parameters were used as an evaluation tool for abdominal and chest imaging protocols. The C-D curves were obtained with the phantom CDRAD 2.0 in computerized radiography and the direct radiography systems (including portable devices). The protocols were 90 and 102 kV in the range of 2 to 20 mAs for the chest and 80 kV in the range of 10 to 80 mAs for the abdomen. The incident air kerma values were evaluated with a solid state sensor. The analysis of these C-D curves help to identify which technique would allow a lower value of the entrance surface air kerma, Ke, while maintaining the image quality from the point of view of C-D detectability. The results showed that the inverse image quality figure, IQFinv, varied little throughout the range of mAs, while the value of Ke varied linearly directly with the mAs values. Also, the complete analysis of the curves indicated that there was an increase in the definition of the details with increasing mAs. It can be concluded that, in the transition phase for the use of the new receptors, it is necessary to evaluate and adjust the practised protocols to ensure, at a minimum, the same levels of the image quality, taking into account the aspects of the radiation protection of the patient.


2020 ◽  
Vol 2 (1) ◽  
Author(s):  
Gagah Yaumiyya Riyoprakoso ◽  
AM Hasan Ali ◽  
Fitriyani Zein

This study is based on the legal responsibility of the assessment of public appraisal reports they make in land procurement activities for development in the public interest. Public assessment is obliged to always be accountable for their assessment. The type of research found in this thesis is a type of normative legal research with the right-hand of the statue approach and case approach. Normative legal research is a study that provides systematic explanation of rules governing a certain legal category, analyzing the relationship between regulations explaining areas of difficulty and possibly predicting future development. . After conducting research, researchers found that one of the causes that made the dispute was a lack of communication conducted between the Government and the landlord. In deliberation which should be the place where the parties find the meeting point between the parties on the magnitude of the damages that will be given, in the field is often used only for the delivery of the assessment of the compensation that has been done.


2020 ◽  
Vol 10 (1) ◽  
pp. 63-71
Author(s):  
Nurhaeda Abbas ◽  
Anggraini Sukmawati ◽  
Muhammad Syamsun

Today the performance measurement of Muhammadiyah Luwuk uUniversity’s performance has not formulated yet based on University’s vision and mission. It will affect the strategic steps needed and performance improvement efforts in the future.  Human resource scorecard is the right system to be applied in Muhammadiyah Luwuk University. The purpose of this study is to designed a performance measurement system at Muhammadiyah Luwuk University using the Human Resource Scorecard with four perspectives: stakeholder, academic management and kemuhammadiyaan, operational and innovation, as well as and learning. Data was analyzed by analytical hierarchy process method. This research was conducted by distributing questionnaires, focus group discussions and in-depth interview with stakeholders at Muhammadiyah Luwuk University. The results showed that there were 14 strategic objectives and 33 key performance indicators to be achieved by the priority objectives, which are: empowerment and development of faculty, increased administrative process quality, improved sound budget performance and, improvement of the relationship with stakeholders.


2020 ◽  
Author(s):  
Kristin Natal Riang Gea

AbstrakKeselamatan pasien merupakan dasar dari pelayanan kesehatan yang baik. Pengetahuan tenaga kesehatan dalam sasaran keselamatan pasien terdiri dari ketepatan identifikasi pasien, peningkatan komunikasi yang efektif, peningkatan keamanan obat yang perlu diwaspadai, kepastian tepat lokasi, prosedur, dan tepat pasien operasi, pengurangan risiko infeksi, pengurangan risiko pasien jatuh. Tujuan penelitian untuk mengetahui hubungan antara pengetahuan dengan penerapan keselamatan pasien pada petugas kesehatan di Puskesmas Kedaung Wetan Kota Tangerang. Metode Penelitian menggunakan deskriptif korelasi menggunakan pendekatan cross sectional. Populasi sebanyak 50 responden. Teknik pengambilan sampel menggunakan total sampling. Instrumen yang digunakan berupa lembar kuesioner. Teknik analisa diatas menggunakan analisa Univariat dan Bivariat. Hasil Penelitian ada Hubungan Pengetahuan dengan Penerapan Keselamatan Pasien pada Petugas Kesehatan, dengan hasil, p value sebesar 0,013 < 0,05 maka dapat disimpulkan bahwa ada Hubungan Pengetahuan dengan Penerapa Keselamatan Pasien pada Petugas Kesehatan. Kesimpulan penelitian ada Hubungan Pengetahuan dengan Penerapan Keselamatan Pasien.. AbstrackPatient safety is the basis of good health services. Knowledge of health personnel in patient safety targets consists of accurate patient identification, increased effective communication, increased safety of the drug that needs to be watched, certainty in the right location, procedure, and precise patient surgery, reduction in risk of infection, reduction in risk of falling patients. The purpose of this study was to determine the relationship between knowledge and the application of patient safety to health workers in the Kedaung Wetan Health Center, Tangerang City. The research method uses descriptive correlation using cross sectional approach. The population is 50 respondents. The sampling technique uses total sampling. The instrument used was a questionnaire sheet. The analysis technique above uses Univariate and Bivariate analysis. The results of the study there is a Relationship of Knowledge with the Implementation of Patient Safety in Health Officers, with the result, p value of 0.013 <0.05, it can be concluded that there is a Relationship between Knowledge and Patient Safety Implementation in Health Officers. The conclusion of the study is the Relationship between Knowledge and the Implementation of Patient Safety.Keywords Knowledge, Patient safety, Health workers