scholarly journals Full wave 3D inverse scattering transmission ultrasound tomography in the presence of high contrast

2020 ◽  
Vol 10 (1) ◽  
Author(s):  
James Wiskin ◽  
Bilal Malik ◽  
David Borup ◽  
Nasser Pirshafiey ◽  
John Klock

AbstractWe present here a quantitative ultrasound tomographic method yielding a sub-mm resolution, quantitative 3D representation of tissue characteristics in the presence of high contrast media. This result is a generalization of previous work where high impedance contrast was not present and may provide a clinically and laboratory relevant, relatively inexpensive, high resolution imaging method for imaging in the presence of bone. This allows tumor, muscle, tendon, ligament or cartilage disease monitoring for therapy and general laboratory or clinical settings. The method has proven useful in breast imaging and is generalized here to high-resolution quantitative imaging in the presence of bone. The laboratory data are acquired in ~ 12 min and the reconstruction in ~ 24 min—approximately 200 times faster than previously reported simulations in the literature. Such fast reconstructions with real data require careful calibration, adequate data redundancy from a 2D array of 2048 elements and a paraxial approximation. The imaging results show that tissue surrounding the high impedance region is artifact free and has correct speed of sound at sub-mm resolution.

Author(s):  
Barbara Filser ◽  
Verena Uslar ◽  
Dirk Weyhe ◽  
Navid Tabriz

Abstract Purpose In primary hyperparathyroidism (PHPT), intraoperative localization of the parathyroid adenoma can be challenging, especially in cases of negative preoperative imaging. Since a focused unilateral parathyroidectomy has benefits compared to a conventional bilateral neck exploration, the question arises whether adenoma size prediction can facilitate a targeted approach. We investigated whether single parathyroid adenoma size can be estimated using preoperative parathyroid hormone (PTH), calcium, and phosphate in patients with PHPT. Preoperative imaging accuracy was evaluated. Methods The data of 156 patients who underwent curative parathyroidectomy for single adenoma PHPT were analyzed retrospectively. Information obtained included laboratory data, imaging results, intraoperative data, and final pathology. Imaging accuracy was analyzed descriptively. The association between preoperative biochemical markers and adenoma dimensions was investigated using Spearman’s correlation coefficient and multivariable regression modeling. Results Cervical ultrasound correctly predicted adenoma laterality in 95.5%, sestamibi scintigraphy in 80.6%, both had lower true-positive rates for quadrant prediction. Patients with negative imaging results showed higher thyroid volumes than those with positive results. Adenoma volume was positively correlated with preoperative PTH (p < 0.001) and calcium (p < 0.001) and negatively correlated with preoperative phosphate (p = 0.001). Using these preoperative biochemical markers and patient age and BMI, adenoma volume can be significantly predicted using the multivariable regression algorithm. Conclusion Cervical ultrasound is superior to scintigraphy for predicting adenoma location and should be the first-choice imaging method, but both methods may be limited by increased thyroid volume. Large adenomas are more likely with higher PTH, higher calcium, and lower phosphate levels. In cases of undetermined adenoma location, an estimation of adenoma volume via our algorithm could corroborate sonographic volume measurements of the suspected adenoma.


Author(s):  
Akira Tonomura

Electron holography is a two-step imaging method. However, the ultimate performance of holographic imaging is mainly determined by the brightness of the electron beam used in the hologram-formation process. In our 350kV holography electron microscope (see Fig. 1), the decrease in the inherently high brightness of field-emitted electrons is minimized by superposing a magnetic lens in the gun, for a resulting value of 2 × 109 A/cm2 sr. This high brightness has lead to the following distinguished features. The minimum spacing (d) of carrier fringes is d = 0.09 Å, thus allowing a reconstructed image with a resolution, at least in principle, as high as 3d=0.3 Å. The precision in phase measurement can be as high as 2π/100, since the position of fringes can be known precisely from a high-contrast hologram formed under highly collimated illumination. Dynamic observation becomes possible because the current density is high.


Author(s):  
Po Fu Chou ◽  
Li Ming Lu

Abstract Dopant profile inspection is one of the focused ion beam (FIB) physical analysis applications. This paper presents a technique for characterizing P-V dopant regions in silicon by using a FIB methodology. This technique builds on published work for backside FIB navigation, in which n-well contrast is observed. The paper demonstrates that the technique can distinguish both n- and p-type dopant regions. The capability for imaging real sample dopant regions on current fabricated devices is also demonstrated. SEM DC and FIB DC are complementary methodologies for the inspection of dopants. The advantage of the SEM DC method is high resolution and the advantage of FIB DC methodology is high contrast, especially evident in a deep N-well region.


BMC Biology ◽  
2021 ◽  
Vol 19 (1) ◽  
Author(s):  
Sergio Gabarre ◽  
Frank Vernaillen ◽  
Pieter Baatsen ◽  
Katlijn Vints ◽  
Christopher Cawthorne ◽  
...  

Abstract Background Array tomography (AT) is a high-resolution imaging method to resolve fine details at the organelle level and has the advantage that it can provide 3D volumes to show the tissue context. AT can be carried out in a correlative way, combing light and electron microscopy (LM, EM) techniques. However, the correlation between modalities can be a challenge and delineating specific regions of interest in consecutive sections can be time-consuming. Integrated light and electron microscopes (iLEMs) offer the possibility to provide well-correlated images and may pose an ideal solution for correlative AT. Here, we report a workflow to automate navigation between regions of interest. Results We use a targeted approach that allows imaging specific tissue features, like organelles, cell processes, and nuclei at different scales to enable fast, directly correlated in situ AT using an integrated light and electron microscope (iLEM-AT). Our workflow is based on the detection of section boundaries on an initial transmitted light acquisition that serves as a reference space to compensate for changes in shape between sections, and we apply a stepwise refinement of localizations as the magnification increases from LM to EM. With minimal user interaction, this enables autonomous and speedy acquisition of regions containing cells and cellular organelles of interest correlated across different magnifications for LM and EM modalities, providing a more efficient way to obtain 3D images. We provide a proof of concept of our approach and the developed software tools using both Golgi neuronal impregnation staining and fluorescently labeled protein condensates in cells. Conclusions Our method facilitates tracing and reconstructing cellular structures over multiple sections, is targeted at high resolution ILEMs, and can be integrated into existing devices, both commercial and custom-built systems.


2021 ◽  
Vol 28 (4) ◽  
pp. 2548-2559
Author(s):  
Andrzej Lorek ◽  
Katarzyna Steinhof-Radwańska ◽  
Anna Barczyk-Gutkowska ◽  
Wojciech Zarębski ◽  
Piotr Paleń ◽  
...  

Contrast-enhanced spectral mammography (CESM) is a promising, digital breast imaging method for planning surgeries. The study aimed at comparing digital mammography (MG) with CESM as predictive factors in visualizing multifocal-multicentric cancers (MFMCC) before determining the surgery extent. We analyzed 999 patients after breast cancer surgery to compare MG and CESM in terms of detecting MFMCC. Moreover, these procedures were assessed for their conformity with postoperative histopathology (HP), calculating their sensitivity and specificity. The question was which histopathological types of breast cancer were more frequently characterized by multifocality–multicentrality in comparable techniques as regards the general number of HP-identified cancers. The analysis involved the frequency of post-CESM changes in the extent of planned surgeries. In the present study, MG revealed 48 (4.80%) while CESM 170 (17.02%) MFMCC lesions, subsequently confirmed in HP. MG had MFMCC detecting sensitivity of 38.51%, specificity 99.01%, PPV (positive predictive value) 85.71%, and NPV (negative predictive value) 84.52%. The respective values for CESM were 87.63%, 94.90%, 80.57% and 96.95%. Moreover, no statistically significant differences were found between lobular and NST cancers (27.78% vs. 21.24%) regarding MFMCC. A treatment change was required by 20.00% of the patients from breast-conserving to mastectomy, upon visualizing MFMCC in CESM. In conclusion, mammography offers insufficient diagnostic sensitivity for detecting additional cancer foci. The high diagnostic sensitivity of CESM effectively assesses breast cancer multifocality/multicentrality and significantly changes the extent of planned surgeries. The multifocality/multicentrality concerned carcinoma, lobular and invasive carcinoma of no special type (NST) cancers with similar incidence rates, which requires further confirmation.


2021 ◽  
Vol 11 (11) ◽  
pp. 5219
Author(s):  
Yosuke Sakurai ◽  
Hirotaka Sato ◽  
Nozomu Adachi ◽  
Satoshi Morooka ◽  
Yoshikazu Todaka ◽  
...  

As a new method for evaluating single crystals and oligocrystals, pulsed neutron Bragg-dip transmission analysis/imaging method is being developed. In this study, a single Bragg-dip profile-fitting analysis method was newly developed, and applied for analyzing detailed inner information in a crystalline grain position-dependently. In the method, the spectrum profile of a single Bragg-dip is analyzed at each position over a grain. As a result, it is expected that changes in crystal orientation, mosaic spread angle and thickness of a perfect crystal can be evaluated from the wavelength, the width and the integrated intensity of the Bragg-dip, respectively. For confirming this effectiveness, the method was applied to experimental data of position-dependent Bragg-dip transmission spectra of a Si-steel plate consisting of oligocrystals. As a result, inner information of multiple crystalline grains could be visualized and evaluated. The small change in crystal orientation in a grain, about 0.4°, could be observed by imaging the Bragg-dip wavelengths. By imaging the Bragg-dip widths, both another grain and mosaic block in a grain were detected. Furthermore, imaging results of the integrated intensities of Bragg-dips were consistent with the results of Bragg-dip width imaging. These small crystallographic changes have not been observed and visualized by previous Bragg-dip analysis methods.


2021 ◽  
Vol 13 (12) ◽  
pp. 2326
Author(s):  
Xiaoyong Li ◽  
Xueru Bai ◽  
Feng Zhou

A deep-learning architecture, dubbed as the 2D-ADMM-Net (2D-ADN), is proposed in this article. It provides effective high-resolution 2D inverse synthetic aperture radar (ISAR) imaging under scenarios of low SNRs and incomplete data, by combining model-based sparse reconstruction and data-driven deep learning. Firstly, mapping from ISAR images to their corresponding echoes in the wavenumber domain is derived. Then, a 2D alternating direction method of multipliers (ADMM) is unrolled and generalized to a deep network, where all adjustable parameters in the reconstruction layers, nonlinear transform layers, and multiplier update layers are learned by an end-to-end training through back-propagation. Since the optimal parameters of each layer are learned separately, 2D-ADN exhibits more representation flexibility and preferable reconstruction performance than model-driven methods. Simultaneously, it is able to better facilitate ISAR imaging with limited training samples than data-driven methods owing to its simple structure and small number of adjustable parameters. Additionally, benefiting from the good performance of 2D-ADN, a random phase error estimation method is proposed, through which well-focused imaging can be acquired. It is demonstrated by experiments that although trained by only a few simulated images, the 2D-ADN shows good adaptability to measured data and favorable imaging results with a clear background can be obtained in a short time.


2021 ◽  
Vol 35 (3) ◽  
pp. 406-414
Author(s):  
Yoko Satoh ◽  
Masami Kawamoto ◽  
Kazunori Kubota ◽  
Koji Murakami ◽  
Makoto Hosono ◽  
...  

AbstractBreast positron emission tomography (PET) has had insurance coverage when performed with conventional whole-body PET in Japan since 2013. Together with whole-body PET, accurate examination of breast cancer and diagnosis of metastatic disease are possible, and are expected to contribute significantly to its treatment planning. To facilitate a safer, smoother, and more appropriate examination, the Japanese Society of Nuclear Medicine published the first edition of practice guidelines for high-resolution breast PET in 2013. Subsequently, new types of breast PET have been developed and their clinical usefulness clarified. Therefore, the guidelines for breast PET were revised in 2019. This article updates readers as to what is new in the second edition. This edition supports two different types of breast PET depending on the placement of the detector: the opposite-type (positron emission mammography; PEM) and the ring-shaped type (dedicated breast PET; dbPET), providing an overview of these scanners and appropriate imaging methods, their clinical applications, and future prospects. The name “dedicated breast PET” from the first edition is widely used to refer to ring-shaped type breast PET. In this edition, “breast PET” has been defined as a term that refers to both opposite- and ring-shaped devices. Up-to-date breast PET practice guidelines would help provide useful information for evidence-based breast imaging.


2012 ◽  
Vol 116 (4) ◽  
pp. 697-702 ◽  
Author(s):  
Neil Roundy ◽  
Johnny B. Delashaw ◽  
Justin S. Cetas

Object Facial nerve paresis can be a devastating complication following resection of large (> 2.5 cm) cerebellopontine angle (CPA) tumors. The authors have developed and used a new high-density diffusion tensor imaging (HD-DT imaging) method, aimed at preoperatively identifying the location and course of the facial nerve in relation to large CPA tumors. Their study objective was to preoperatively identify the facial nerve in patients with large CPA tumors and compare their HD-DT imaging method with a traditional standard DT imaging method and correlate with intraoperative findings. Methods The authors prospectively studied 5 patients with large (> 2.5 cm) CPA tumors. All patients underwent preoperative traditional standard- and HD-DT imaging. Imaging results were correlated with intraoperative findings. Results Utilizing their HD-DT imaging method, the authors positively identified the location and course of the facial nerve in all patients. In contrast, using a standard DT imaging method, the authors were unable to identify the facial nerve in 4 of the 5 patients. Conclusions The HD-DT imaging method that the authors describe and use has proven to be a powerful, accurate, and rapid method for preoperatively identifying the facial nerve in relation to large CPA tumors. Routine integration of HD-DT imaging in preoperative planning for CPA tumor resection could lead to improved facial nerve preservation.


Sign in / Sign up

Export Citation Format

Share Document