scholarly journals A COMBINED USE OF FDM AND DOE METHOD TO DERIVE A NEW TRANSIENT SIMPLIFIED SEMI-ANALYTICAL MODEL: A CASE STUDY OF ANHYDRITE RADIANT SLAB

2020 ◽  
Vol 330 ◽  
pp. 01002
Author(s):  
Abdelatif Merabtine ◽  
Abdelhamid Kheiri ◽  
Salim Mokraoui

Radiant floor heating systems (FHS) are considered as reliable heating systems since they ensure maintaining inside air temperature and reduce its fluctuations more efficiently than conventional heating systems. The presented study investigates the dynamic thermal response of an experimental FHS equipped with an anhydrite radiant slab. A new simplified model based on an analytical correlation is proposed to evaluate the heating radiant slab surface temperature and examine its thermal behavior under dynamic conditions. In order the validate the developed analytical model, an experimental scenario, under transient conditions, was performed in a monitored full-scale test cell. 2D and 3D numerical models were also developed to evaluate the accuracy of the analytical model. The method of Design of Experiments (DoE) was used to both derive meta-models, to analytically estimate the surface temperature, and perform a sensitivity study.

Author(s):  
Muge Pirtini Cetingul ◽  
Cila Herman

The increased availability of thermal imaging cameras has led to a growing interest in the application of infrared imaging techniques to the detection and identification of subsurface structures. These imaging techniques are based on the following principle: when a surface is heated or cooled, variations in the thermal properties of a structure located underneath the surface result in identifiable temperature contours on it. These contours are characteristic of the structure’s shape, depth, and its thermal properties. We study the use of the transient thermal response of skin layers to determine to which extent the surface temperature distribution reflects the properties of subsurface structures, such as lesions. A numerical model using the finite element method is described to obtain this response and key results are reported in the paper. A sensitivity study is conducted first to better understand the thermal response of the system and the role of various system and model parameters. We explore the extent to which we are able to draw conclusions regarding the size, depth and nature of subsurface structures and accuracy of these conclusions based on the surface temperature response alone. This work validates the idea of examining the transient thermal response and using thermal imaging as a solution for lesion identification. A sensitivity study of surface temperature distribution to variations of thermophysical properties, blood perfusion rate, and thicknesses of skin layers is performed. It is observed that variations in these parameters have little impact on the surface temperature distribution. The work reported in the paper is a portion of a comprehensive research effort involving experiments on a phantom model as well as measurements on patients. Future work will focus on comparing the results of our 2D numerical modeling efforts with the experimental results using a skin tissue-mimicking phantom. Knowledge gained from the modeling and experimental efforts will be utilized in characterizing lesions in patient studies. The focus of this paper is the computational sensitivity analysis.


Author(s):  
C. C. Ngo ◽  
B. A. Alhabeeb ◽  
M. Balestrieri

Radiant floor heating systems have become popular due to their advantages over conventional heating systems in residential, commercial and industrial spaces. They are also used for snow and ice melting and turf conditioning applications. This paper presents a general study focuses on the design of radiant floor heating systems and investigates the effect of design parameters such as pipe spacing (ranging from 4 in. to 12 in.), pipe depth (ranging from 2.5 in. to 6.5 in.) and pipe temperature (45 °C, 65 °C and 85 °C) on the performance of radiant floor heating system embedded in different mediums (air, gravel and sand). The experimental results showed that a radiant heating system with pipes embedded at a shallow burial depth and placed closer together resulted with a more desired floor temperature distribution. The average floor temperature was also higher when the piping system was embedded in an air-filled space instead of a porous medium such as gravel or sand.


Energies ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1321
Author(s):  
Yu-Jin Hwang ◽  
Jae-Weon Jeong

The objective of this research is to establish an appropriate operating strategy for a radiant floor heating system that additionally has an air source heat pump for providing convective air heating separately, leading to heating energy saving and thermal comfort in residential buildings. To determine the appropriate optimal operating ratio of each system taking charge of combined heating systems, the energy consumption of the entire system was drawn, and the adaptive floor surface temperature was reviewed based on international standards and literature on thermal comfort. For processing heating loads with radiant floor heating and air source heating systems, the heating capacity of radiant floor heating by 1 °C variation in floor temperature was calculated, and the remaining heating load was handled by the heating capacity of the convective air heating heat pump. Consequently, when the floor temperature was 25 °C, all heating loads were removed by radiant floor heating only. When handling all heating loads with the heat pump, 59.2% less energy was used compared with radiant floor heating only. Considering the local discomfort of the soles of the feet, the floor temperature is expected to be suitable at 22–23 °C, and 31.5–37.6% energy saving compared with those of radiant floor heating alone were confirmed.


Energies ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 1195
Author(s):  
Ali Saberi Derakhtenjani ◽  
Andreas K. Athienitis

This paper presents control strategies to activate energy flexibility for zones with radiant heating systems in response to changes in electricity prices. The focus is on zones with radiant floor heating systems for which the hydronic pipes are located deep in the concrete and, therefore, there is a significant thermal lag. A perimeter zone test-room equipped with a hydronic radiant floor system in an environmental chamber is used as a case study. A low order thermal network model for the perimeter zone, validated with experimental measurements, is utilized to study various control strategies in response to changes in the electrical grid price signal, including short term (nearly reactive) changes of the order of 10–15 min notice. An index is utilized to quantify the building energy flexibility with the focus on peak demand reduction for specific periods of time when the electricity prices are higher than usual. It is shown that the developed control strategies can aid greatly in enhancing the zone energy flexibility and minimizing the cost of electricity and up to 100% reduction in peak power demand and energy consumption is attained during the high-price and peak-demand periods, while maintaining acceptable comfort conditions.


2016 ◽  
Vol 16 (3) ◽  
pp. 1773-1788 ◽  
Author(s):  
A.-M. Blechschmidt ◽  
A. Richter ◽  
J. P. Burrows ◽  
L. Kaleschke ◽  
K. Strong ◽  
...  

Abstract. Intense, cyclone-like shaped plumes of tropospheric bromine monoxide (BrO) are regularly observed by GOME-2 on board the MetOp-A satellite over Arctic sea ice in polar spring. These plumes are often transported by high-latitude cyclones, sometimes over several days despite the short atmospheric lifetime of BrO. However, only few studies have focused on the role of polar weather systems in the development, duration and transport of tropospheric BrO plumes during bromine explosion events. The latter are caused by an autocatalytic chemical chain reaction associated with tropospheric ozone depletion and initiated by the release of bromine from cold brine-covered ice or snow to the atmosphere. In this manuscript, a case study investigating a comma-shaped BrO plume which developed over the Beaufort Sea and was observed by GOME-2 for several days is presented. By making combined use of satellite data and numerical models, it is shown that the occurrence of the plume was closely linked to frontal lifting in a polar cyclone and that it most likely resided in the lowest 3 km of the troposphere. In contrast to previous case studies, we demonstrate that the dry conveyor belt, a potentially bromine-rich stratospheric air stream which can complicate interpretation of satellite retrieved tropospheric BrO, is spatially separated from the observed BrO plume. It is concluded that weather conditions associated with the polar cyclone favoured the bromine activation cycle and blowing snow production, which may have acted as a bromine source during the bromine explosion event.


Author(s):  
Leon M. Headings ◽  
Gregory N. Washington

The goal of this research is to develop a framework for replacing conventional heating and cooling systems with distributed, continuously and electrically controlled, building-integrated thermoelectric (BITE) heat pumps. The coefficient of performance of thermoelectric heat pumps increases as the temperature difference across them decreases and as the amplitude of temperature oscillations decreases. As a result, this research examines how thermal insulation and mass elements can be integrated with thermoelectrics as part of active multi-layer structures in order to minimize net energy consumption. In order to develop BITE systems, an explicit finite volume model was developed to model the dynamic thermal response of active multi-layer wall structures subjected to arbitrary boundary conditions (interior and exterior temperatures and interior heat loads) and control algorithms. Using this numerical model, the effects of wall construction on net system performance were examined. These simulation results provide direction for the ongoing development of BITE systems.


2018 ◽  
Vol 615 ◽  
pp. A20 ◽  
Author(s):  
Wasim Iqbal ◽  
Valentine Wakelam

Context. Species abundances in the interstellar medium (ISM) strongly depend on the chemistry occurring at the surfaces of the dust grains. To describe the complexity of the chemistry, various numerical models have been constructed. In most of these models, the grains are described by a single size of 0.1 μm. Aims. We study the impact on the abundances of many species observed in the cold cores by considering several grain sizes in the Nautilus multi-grain model. Methods. We used grain sizes with radii in the range of 0.005 μm to 0.25 μm. We sampled this range in many bins. We used the previously published, MRN and WD grain size distributions to calculate the number density of grains in each bin. Other parameters such as the grain surface temperature or the cosmic-ray-induced desorption rates also vary with grain sizes. Results. We present the abundances of various molecules in the gas phase and also on the dust surface at different time intervals during the simulation. We present a comparative study of results obtained using the single grain and the multi-grain models. We also compare our results with the observed abundances in TMC-1 and L134N clouds. Conclusions. We show that the grain size, the grain size dependent surface temperature and the peak surface temperature induced by cosmic ray collisions, play key roles in determining the ice and the gas phase abundances of various molecules. We also show that the differences between the MRN and the WD models are crucial for better fitting the observed abundances in different regions in the ISM. We show that the small grains play a very important role in the enrichment of the gas phase with the species which are mainly formed on the grain surface, as non-thermal desorption induced by collisions of cosmic ray particles is very efficient on the small grains.


Author(s):  
Vivek Vishwakarma ◽  
Ankur Jain

A number of past papers have described experimental techniques for measurement of thermal conductivity of substrates and thin films of technological interest. Nearly all substrates measured in the past are rigid. There is a lack of papers that report measurements on a flexible substrate such as thin plastic. The paper presents an experimental methodology to deposit a thin film microheater device on a plastic substrate. This device, comprising a microheater line and a temperature sensor line is used to measure the thermal conductivity of the plastic substrate using the transient thermal response of the plastic substrate to a heating current. An analytical model describing this thermal response is presented. Thermal conductivity of the plastic substrate is determined by comparison of experimental data with the analytical model. Results described in this paper may aid in development of an understanding of thermal transport in flexible substrates.


Sign in / Sign up

Export Citation Format

Share Document