Energy performance of the economizer cycle under three climatic conditions in Saudi Arabia

2001 ◽  
Vol 22 (2) ◽  
pp. 83-94 ◽  
Author(s):  
I. M. Budaiwi
2020 ◽  
pp. 50-64
Author(s):  
Kuladeep Kumar Sadevi ◽  
Avlokita Agrawal

With the rise in awareness of energy efficient buildings and adoption of mandatory energy conservation codes across the globe, significant change is being observed in the way the buildings are designed. With the launch of Energy Conservation Building Code (ECBC) in India, climate responsive designs and passive cooling techniques are being explored increasingly in building designs. Of all the building envelope components, roof surface has been identified as the most significant with respect to the heat gain due to the incident solar radiation on buildings, especially in tropical climatic conditions. Since ECBC specifies stringent U-Values for roof assembly, use of insulating materials is becoming popular. Along with insulation, the shading of the roof is also observed to be an important strategy for improving thermal performance of the building, especially in Warm and humid climatic conditions. This study intends to assess the impact of roof shading on building’s energy performance in comparison to that of exposed roof with insulation. A typical office building with specific geometry and schedules has been identified as base case model for this study. This building is simulated using energy modelling software ‘Design Builder’ with base case parameters as prescribed in ECBC. Further, the same building has been simulated parametrically adjusting the amount of roof insulation and roof shading simultaneously. The overall energy consumption and the envelope performance of the top floor are extracted for analysis. The results indicate that the roof shading is an effective passive cooling strategy for both naturally ventilated and air conditioned buildings in Warm and humid climates of India. It is also observed that a fully shaded roof outperforms the insulated roof as per ECBC prescription. Provision of shading over roof reduces the annual energy consumption of building in case of both insulated and uninsulated roofs. However, the impact is higher for uninsulated roofs (U-Value of 3.933 W/m2K), being 4.18% as compared to 0.59% for insulated roofs (U-Value of 0.33 W/m2K).While the general assumption is that roof insulation helps in reducing the energy consumption in tropical buildings, it is observed to be the other way when insulation is provided with roof shading. It is due to restricted heat loss during night.


Energies ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 1080
Author(s):  
Mamdooh Alwetaishi ◽  
Omrane Benjeddou

The concern regarding local responsive building design has gained more attention globally as of late. This is due to the issue of the rapid increase in energy consumption in buildings for the purpose of heating and cooling. This has become a crucial issue in educational buildings and especially in schools. The major issue in school buildings in Saudi Arabia is that they are a form of prototype school building design (PSBD). As a result, if there is any concern in the design stage and in relation to the selection of building materials, this will spread throughout the region. In addition to that, the design is repeated regardless of the climate variation within the kingdom of Saudi Arabia. This research will focus on the influence of the window to wall ratio on the energy load in various orientations and different climatic regions. The research will use the energy computer tool TAS Environmental Design Solution Limited (EDSL) to calculate the energy load as well as solar gain. During the visit to the sample schools, a globe thermometer will be used to monitor the globe temperature in the classrooms. This research introduces a framework to assist architects and engineers in selecting the proper window to wall ratio (WWR) in each direction within the same building based on adequate natural light with a minimum reliance on energy load. For ultimate WWR for energy performance and daylight, the WWR should range from 20% to 30%, depending on orientation, in order to provide the optimal daylight factor combined with building energy efficiency. This ratio can be slightly greater in higher altitude locations.


2021 ◽  
pp. 174425912110560
Author(s):  
Yassine Chbani Idrissi ◽  
Rafik Belarbi ◽  
Mohammed Yacine Ferroukhi ◽  
M’barek Feddaoui ◽  
Driss Agliz

Hygrothermal properties of building materials, climatic conditions and energy performance are interrelated and have to be considered simultaneously as part of an optimised building design. In this paper, a new approach to evaluate the energy consumption of residential buildings in Morocco is presented. This approach is based on the effect of coupled heat and moisture transfer in typical residential buildings and on their responses to the varied climatic conditions encountered in the country. This approach allows us to evaluate with better accuracy the response of building energy performance and the indoor comfort of building occupants. Annual energy consumption, cooling and heating energy requirements were estimated considering the six climatic zones of Morocco. Based on the results, terms related to coupled heat and moisture transfer can effectively correct the existing energy consumption calculations of the six zones of Morocco, which currently do not consider energy consumption due to coupled heat and moisture transfer.


2018 ◽  
Vol 10 (7) ◽  
pp. 2548 ◽  
Author(s):  
Mariangela De Vita ◽  
Paolo Beccarelli ◽  
Eleonora Laurini ◽  
Pierluigi De Berardinis

The aim of this research, carried out in collaboration with Maco Technology Inc., was to analyse the energy performance of temporary textile structures that are often used to host itinerant events. This paper illustrates the dynamic simulations carried on the Ducati Pavilion, designed by Maco Technology, which hosted Ducati staff during the different stages of the Superbike World Championship. Specific aspects relating to the structural/constructive system of the project were also analysed. The theme of energy saving and carbon reduction is of great importance in temporary and itinerant structures and environmental sustainability in relation to the materials used, storage, re-use, mode of transport and ability to respond efficiently to the climatic conditions of the installation sites is an important aspect. The Ducati Pavilion was modelled and analysed from an energy point of view using Design Builder software. Ways of improving performance were analysed under summer conditions. The paper focuses on the importance of optimizing the performance of textile envelopes: the methodology proposed allows visible savings in terms of energy consumption and achieves good levels of environmental comfort in temporary buildings with low thermal mass structure.


Author(s):  
Salma AlHajri ◽  
Donat Agosti

The State of Qatar is a small peninsula located in the northeastern part of the Arabian Peninsula. It is classified as a subtropical desert with an extreme harsh climatic conditions in summer and mild winter. Information on Formicidae of Qatar as well as its insect fauna is poorly documented. So far only six species of Formicidae (ants) belonging to five genera have been recorded from Qatar. At least 300 ant species have been recorded from the Arabian Peninsula (Collingwood et al., 2011). For instance, Collingwood and Agosti (1996) reported a list of 265 ant species in Saudi Arabia. Moreover, Collingwood et al. (2011) published a list of 126 ant species in UAE and Sharaf et al. (2018a) recorded 123 ant species from Oman. This indicates a significant gap regarding our knowledge of the ant fauna and their diversity in Qatar. This study provides the first taxonomic survey of the ant fauna of Qatar. Ant specimens were collected by using aspirator, direct hand collection, litter sifting and pitfall traps during the period of April 2015 to March 2019 from 43 sites around the country. In the present study, 45 species are newly recorded for the ant fauna of the state of Qatar increasing the total number of ant species from Qatar to 51 species, including one additional subfamily, and 16 additional genera.


2016 ◽  
Vol 5 (1-2) ◽  
pp. 162-170
Author(s):  
Henrik Zsiborács ◽  
Béla Pályi ◽  
Gábor Pintér ◽  
Nóra Hegedűsné Baranyai ◽  
Péter Szabó ◽  
...  

In this paper the economic aspects of the water spraying cooling technology of polycrystalline solar modules with respect to the effect of temperature on performance was examined. The main purpose of this work was to explore the economic relations of the spraying cooling technology of solar modules. In the study 5 kW PV system for residential customers, 5 kW and 50 kW PV system for business customer were studied. In Hungarian climatic conditions, considering the inflation values used, the interest rate, the annual utilization of the cooling system, the expected profit and the maintenance costs show us that neither of the cooling solutions is capable of better payback time than the reference uncooled solar PV system. The further research goal is to determine the usability of the cooling system in such countries which have on the one hand more ideal climatic conditions, on the other hand more predictable green energy feed regulations.


2019 ◽  
Vol 43 (5) ◽  
pp. 398-427 ◽  
Author(s):  
Hamed H Saber ◽  
Wahid Maref ◽  
Ali E Hajiah

Many parts of the building envelopes contain enclosed airspaces. Also, the insulating glass units in fenestration systems, such as curtain walls, windows, and skylight devices, contain enclosed spaces that are normally filled with air or heavy gas such as argon, xenon, or krypton. The thermal resistance (R-value) of an enclosed space depends mainly on the type of the filling gas, emissivity of all surfaces that bound the space, the size and orientation of the space, the direction of heat flow through the space, and the respective temperatures of all surfaces that define the space. Assessing the energy performance of building envelopes and fenestration systems, subjected to different climatic conditions, requires accurate determination of the R-values of the enclosed spaces. In this study, a comprehensive review is conducted on the thermal performance of enclosed airspaces for different building applications. This review includes the computational and experimental methods for determining the effective R-value of enclosed reflective airspaces. Also, the different parameters that affect the thermal performance of enclosed airspaces are discussed. These parameters include the following: (a) dimensions, (b) inclination angles, (c) directions of heat flow, (d) emissivity of all surfaces that bound the space, and (e) operating conditions. Moreover, numerical simulations are conducted using a previously developed and validated model to investigate the effect of the inclination angle, direction of heat transfer, and the coating emissivity on the R-values of enclosed spaces when they are filled with different types of gases.


2019 ◽  
Vol 116 ◽  
pp. 00039 ◽  
Author(s):  
Piotr Kowalski ◽  
Paweł Szałański

The article discusses the problem of determining for air heat pumps the seasonal efficiency of energy production necessary to determine the energy performance of a building. On the example of selected Polish cities (Suwalki, Bialystok, Warsaw, Wroclaw, Zielona Gora, Resko, Szczecinek, Koszalin) the influence of climatic conditions on the SCOP of an exemplary air-to-air heat pump and on the result of building energy performance calculations was analysed. SCOPs for each location were determined according to the method of EN 14825. The difference between SCOP for average (A) and colder (C) climates according to EN 14825 was 35.6%. It has been shown that the climate of Polish cities may be similar to both the average climate (A) and the colder climate (C), or they significantly differ from both climates. The most significant difference in SCOP between the analysed cities was obtained for Suwalki and Szczecinek. It was 31.9% and 31.4% for the assumed heating season length as for climate (A) and (C) respectively. For the exemplary building in Suwalki, taking SCOP for the average climate (A) and not based on climatic data of Suwalki gives an error of 39.3% in the calculation of primary energy for heating. For the same locations, the differences in SCOP and EP resulting from the assumption of the heating season length as for the average climate (A) or as for the colder climate (C) were respectively from 2.4% to 3.3% and from -3.4% to -2.2%. In diversified Polish climate, assuming the same SCOP values of air heat pumps regardless of location does not allow for their full comparison with devices whose efficiency does not depend on climatic conditions. The authors suggest that when calculating the energy performance of the building, the SCOP should be always determined on the basis of the local climate and the length of the heating season.


2018 ◽  
Vol 10 (12) ◽  
pp. 4373 ◽  
Author(s):  
Omar Asfour

This study investigates the use of building-integrated photovoltaics (BIPVs) as shading devices in hot climates, with reference to the conditions of Saudi Arabia. It used parametric numerical modelling to critically appraise the potential of eight design configurations in this regard, including vertical and horizontal shading devices with different inclination angles. The study assumed that the examined shading devices could be entirely horizontal or vertical on the three exposed facades, which is common practice in architecture. The study found that the examined configurations offered different solar and shading potentials. However, the case of horizontal BIPV shading devices with a 45° tilt angle received the highest amount of annual total insolation (104 kWh/m2) and offered effective window shading of 96% of the total window area on average in summer. The study concluded that, unlike the common recommendation of avoiding horizontal shading devices on eastern and western facades, it is possible in countries characterised with high solar altitudes such as Saudi Arabia to use them effectively to generate electricity and provide the required window shading.


Sign in / Sign up

Export Citation Format

Share Document