Modeling of Axial Compressor With Large Tip Clearances

Author(s):  
Simon Evans ◽  
Junsok Yi ◽  
Sean Nolan ◽  
Liselle Joseph ◽  
Michael Ni ◽  
...  

Abstract In the drive for lower fuel consumption through increased bypass ratio and increased overall pressure ratio (OPR), engine designs for the next generation of single-aisle aircraft will require core sizes below 3 lb/s and OPRs above 50. Traditionally, these core sizes are the domain of centrifugal compressors, but materials limit pressure ratio in these machines to well below 50. An all-axial high pressure compressor (HPC) at this core size, however, comes with limitations associated with the small blade spans at the back of the HPC, as clearances, fillets and leading edges do not scale with the core size. The result is a substantial efficiency penalty, driven primarily by the tip leakage flow produced by the larger clearance-to-span ratio, which negates the cycle efficiency benefits of the high OPR. In order to enable small-core, high-OPR, all-axial compressors mitigating technologies need to be developed and implemented to reduce the large clearance-to-span efficiency penalty. However, for this technology development to be successful, it is imperative that predictive design tools accurately model the overall flow physics and trends of the technologies developed. In this paper we describe an effort to determine whether different modeling standards are required for a large clearance-to-span ratio, and if so, identify criteria for an appropriate solver and/or mesh. Multiple models are run and results compared with data collected in the NASA Glenn Research Center’s Low-Speed Axial Compressor. These comparisons show that steady Reynolds-Averaged Navier-Stokes (RANS) solvers can predict the pressure-rise characteristic to an acceptable level of accuracy, if careful attention is paid to mesh topology in the tip region. However, unsteady tools are necessary to accurately capture radial profiles of blockage and total pressure. The Delayed-Detached Eddy Simulation model was also used to run this geometry, but did not resolve any additional features not captured by the unsteady RANS simulation near stall.

2021 ◽  
pp. 1-27
Author(s):  
Simon Evans ◽  
Junsok Yi ◽  
Sean Nolan ◽  
Liselle Joseph ◽  
Michael Ni ◽  
...  

Abstract In the drive for lower fuel consumption, engine designs for the next generation of single-aisle aircraft will require core sizes below 3 lb/s and OPRs above 50. Traditionally, these core sizes are the domain of centrifugal compressors, but materials limit OPR in these machines. An all-axial HPC at this core size, however, comes with limitations associated with the small blade spans at the back of the HPC, as clearances, fillets and leading edges do not scale with the core size. The result is a substantial efficiency penalty, driven primarily by the tip leakage flow produced by the larger clearance-to-span ratio. To enable small-core, high-OPR, all-axial compressors, mitigating technologies need to be developed and implemented to reduce this penalty. For this technology development to be successful, it is imperative that predictive design tools accurately model the overall flow physics and trends of the technologies developed. In this paper we describe an effort to determine whether different modeling standards are required for large clearance-to-span ratios, and if so, identify criteria for an appropriate solver and/or mesh. Multiple models are run and results compared with data collected in the NASA-GRC Low-Speed Axial Compressor. These comparisons show that steady RANS solvers can predict the pressure-rise characteristic to an acceptable level of accuracy, if careful attention is paid to mesh topology in the tip region. However, unsteady tools are necessary to accurately capture radial profiles of blockage and total pressure.


Author(s):  
Jens Ortmanns

In order to increase the efficiency of a compressor module, several loss sources such as aerofoil profile loss, secondary loss and clearance flow phenomena must be taken into account and balanced in the most efficient way. This current document presents the results of a numerical investigation based on a conventionally loaded high pressure compressor stage with different inlet and exit swirls. The effects of changing the degree of reaction on the compressor stage flow pattern is analysed in detail. In general, the correlation between the overall stage efficiency at constant pressure ratio and the degree of stage reaction is low. Nevertheless, the results show a direct impact on the rotor tip leakage flow and the secondary flow phenomena in the stator end-wall region when the degree of reaction is modified which is driven by the change in static pressure rise between the rotor and the stator passages. The balance of these two loss sources might have an impact on the efficiency and the stall behaviour of a multi-stage compressor.


Author(s):  
Reid A. Berdanier ◽  
Nicole L. Key

Large rotor tip clearances and the associated tip leakage flows are known to have a significant effect on overall compressor performance. However, detailed experimental data reflecting these effects for a multistage compressor are limited in the open literature. As design trends lead to increased overall compressor pressure ratio for thermal efficiency benefits and increased bypass ratios for propulsive benefits, the rear stages of the high-pressure compressor will become physically small. Because rotor tip clearances cannot scale exactly with blade size due to the margin needed for thermal growth considerations, relatively large tip clearances will be a reality for these rear stages. Experimental data have been collected from a three-stage axial compressor to assess performance with three-tip clearance heights representative of current and future small core machines. Trends of overall pressure rise, stall margin, and efficiency are evaluated using clearance derivatives, and the summarized data presented here begin to narrow the margin of tip clearance sensitivities outlined by previous studies in an effort to inform future compressor designs. Furthermore, interstage measurements show stage matching changes and highlight specific differences in the performance of rotor 1 and stator 2 compared to other blade rows in the machine.


2004 ◽  
Vol 126 (3) ◽  
pp. 333-338 ◽  
Author(s):  
Axel Fischer ◽  
Walter Riess ◽  
Joerg R. Seume

The FVV sponsored project “Bow Blading” (cf. acknowledgments) at the Turbomachinery Laboratory of the University of Hannover addresses the effect of strongly bowed stator vanes on the flow field in a four-stage high-speed axial compressor with controlled diffusion airfoil (CDA) blading. The compressor is equipped with more strongly bowed vanes than have previously been reported in the literature. The performance map of the present compressor is being investigated experimentally and numerically. The results show that the pressure ratio and the efficiency at the design point and at the choke limit are reduced by the increase in friction losses on the surface of the bowed vanes, whose surface area is greater than that of the reference (CDA) vanes. The mass flow at the choke limit decreases for the same reason. Because of the change in the radial distribution of axial velocity, pressure rise shifts from stage 3 to stage 4 between the choke limit and maximum pressure ratio. Beyond the point of maximum pressure ratio, this effect is not distinguishable from the reduction of separation by the bow of the vanes. Experimental results show that in cases of high aerodynamic loading, i.e., between maximum pressure ratio and the stall limit, separation is reduced in the bowed stator vanes so that the stagnation pressure ratio and efficiency are increased by the change to bowed stators. It is shown that the reduction of separation with bowed vanes leads to a increase of static pressure rise towards lower mass flow so that the present bow bladed compressor achieves higher static pressure ratios at the stall limit.


2019 ◽  
Vol 141 (12) ◽  
Author(s):  
Yangwei Liu ◽  
Luyang Zhong ◽  
Lipeng Lu

Tip leakage vortex (TLV) has a large impact on compressor performance and should be accurately predicted by computational fluid dynamics (CFD) methods. New approaches of turbulence modeling, such as delayed detached eddy simulation (DDES), have been proposed, the computational resources of which can be reduced much more than for large eddy simulation (LES). In this paper, the numerical simulations of the rotor in a low-speed large-scale axial compressor based on DDES and unsteady Reynolds-averaged Navier–Stokes (URANS) are performed, thus improving our understanding of the TLV dynamic mechanisms and discrepancy of these two methods. We compared the influence of different time steps in the URANS simulation. The widely used large time-step makes the unsteadiness extremely weak. The small time-step shows a better result close to DDES. The time-step scale is related to the URANS unsteadiness and should be carefully selected. In the time-averaged flow, the TLV in DDES dissipates faster, which has a more similar structure to the experiment. Then, the time-averaged and instantaneous results are compared to divide the TLV into three parts. URANS cannot give the loss of stability and evolution details of TLV. The fluctuation velocity spectra show that the amplitude of high frequencies becomes obvious downstream from the TLV, where it becomes unstable. Last, the anisotropy of the Reynolds stress of these two methods is analyzed through the Lumley triangle to see the distinction between the methods and obtain the Reynolds stress. The results indicate that the TLV latter part in DDES is anisotropic, while in URANS it is isotropic.


Author(s):  
Chengwu Yang ◽  
Ge Han ◽  
Shengfeng Zhao ◽  
Xingen Lu ◽  
Yanfeng Zhang ◽  
...  

Abstract The blades of rear stages in small size core compressors are reduced to shorter than 20 mm or even less due to overall high pressure ratio. The growing of tip clearance-to-blade height ratio of the rear stages enhance the leakage flow and increase the possibility of a strong clearance sensitivity, thus limiting the compressor efficiency and stability. A new concept of compressor, namely diffuser passage compressor (DP), for small size core compressors was introduced. The design aims at making the compressors robust to tip clearance leakage flow by reducing pressure difference between pressure and suction surfaces. To validate the concept, the second stage of a two-stage highly loaded axial compressor was designed with DP rotor according to a diffuser map. The diffuser passage stage has the same inlet condition and loading as the conventional compressor (CNV) stage, of which the work coefficient is around 0.37. The predicted performance and flow field of the DP were compared with the conventional axial compressor in detail. The rig testing was supplemented with the numerical predictions. Results reveal that the throttle characteristic of DP indicates higher pressure rise and the loss reduction in tip clearance is mainly responsible for the performance improvement. For the compressor with DP, the pressure and flow angle are more uniform on exit plane. What’s more, the rotor with diffused passage reveals more robust than the conventional rotor at double clearance gap. Furthermore, the experimental data indicate that DP presents higher pressure rise at design and part speeds. At design speed, the stall margin was extended by 7.25%. Moreover, peak adiabatic efficiency of DP is also higher than that of CNV by about 0.7%.


Author(s):  
Zhibo Zhang ◽  
Xianjun Yu ◽  
Baojie Liu

The detailed evolutionary processes of the tip leakage flow/vortex inside the rotor passage are still not very clear for the difficulties of investigating of them by both experimental and numerical methods. In this paper, the flow fields near the rotor tip region inside the blade passage with two tip gaps, 0.5% and 1.5% blade height respectively, were measured by using stereoscopic particle image velocimetry (SPIV) in a large-scale low speed axial compressor test facility. The measurements are conducted at four different operating conditions, including the design, middle, maximum static pressure rise and near stall conditions. In order to analyze the variations of the characteristics of the tip leakage vortex (TLV), the trajectory, concentration, size, streamwise velocity, and the blockage parameters are extracted from the ensemble-averaged results and compared at different compressor operating conditions and tip gaps. The results show that the formation of the TLV is delayed with large tip clearance, however, its trajectory moves much faster in an approximately linear way from the blade suction side to pressure side. In the tested compressor, the size of the tip gap has little effects on the scale of the TLV in the spanwise direction, on the contrary, its effects on the pitch-wise direction is very prominent. Breakdown of the TLV were both found at the near-stall condition with different tip gaps. The location of the initiation of the TLV breakdown moves downstream from the 60% chord to 70% chord as the tip gap increases. After the TLV breakdown occurs, the flow blockage near the rotor tip region increases abruptly. The peak value of the blockage effects caused by the TLV breakdown is doubled with the tip gap size increasing from 0.5% to 1.5% blade span.


Author(s):  
C. H. Muller ◽  
A. Sabatiuk

The axial supersonic compressors of the “shock-in-rotor” type are under development for application to small gas turbines. A passage flow approach and passage criteria were used to design and develop the airfoils for the highly loaded rotor and stator blading of these 4 lb/sec machines. The overall stage performance values demonstrated to date are 2.06:1 pressure ratio at 78 percent adiabatic efficiency and 2.56:1 at 74.4 percent efficiency. The loss data and static pressure rise measured for the rotors and exit stators provide ample evidence that the higher design performance goals can be met.


2021 ◽  
Vol 15 (3) ◽  
pp. 8440-8449
Author(s):  
Sarallah Abbasi ◽  
Maryam Alizadeh

This study investigated a three-dimensional flow analysis on a two-stage contra-rotating axial compressor using the Navier–Stokes, continuity, and energy equations with Ansys CFX commercial software. In order to validate the obtained results, the absolute and relative flow angles curves for each rotor in radial direction were extracted and compared with the other investigation results, indicating good agreement. The compressor efficiency curve also was extracted by varying the compressor pressure ratio and compressor efficiency against mass flow rate. The flow results revealed that further distortion of the flow structure in the second rotor imposed a greater increase in the amount of entropy, especially at near-stall conditions. The increase of entropy in the second rotor is due to the interference of the tip leakage flow with the main flow which consequently caused more drops in the second rotor, suggesting that more efficacy of flow control methods occurred in the second rotor than in the first rotor.


2021 ◽  
Author(s):  
Chunill Hah

Abstract The flow physics in a large rotor tip gap in a 1.5-stage axial compressor is investigated in the current study. The flow structure in the rotor tip region is complex with several dominant vortical structures of opposite rotation, resulting in inhomogeneous and highly anisotropic turbulence. Earlier measurements show that eddy viscosity is negative over large parts of the tip region and eddy viscosity varies among stress/strain components. The present study aims to understand how the complex nature of rotor tip leakage flow affects compressor performance when the tip gap size is greater than 4–5% of the rotor span, which is typical of advanced small core engines. Unsteady Reynolds-averaged Navier-Stokes (URANS) and Large Eddy Simulation (LES) techniques are applied to study flow physics in a large rotor tip gap (5.5% of rotor span) in a 1.5-stage axial compressor. Calculated flow fields from the two different approaches are compared with available measurements and examined in detail. LES calculates the pressure rise in the present compressor fairly well, while URANS with a standard two-equation turbulence closure underpredicts the pressure rise by 15–20% of the measured values. The current study shows that URANS with the current turbulence closure produces much higher all-positive eddy viscosity in the tip-gap region compared to measurements and LES. The distribution of eddy viscosity in the URANS simulation is also wrong. Consequently, the flow in the tip region is highly damped with significantly larger blockage generation, which results in the tip leakage vortex (TLV) staying closer to the blade suction side compared to the measurement. When the TLV stays closer to the blade, both flow turning and the pressure rise across the compressor are reduced compared to the measurements. It appears that this effect is amplified by a large rotor tip gap.


Sign in / Sign up

Export Citation Format

Share Document