Design and Analysis of the Axial Bypass Compressor Blade of the Supercritical CO2 Gas Turbine

Author(s):  
Takao Ishizuka ◽  
Yasushi Muto ◽  
Masanori Aritomi ◽  
Nobuyoshi Tsuzuki ◽  
Hiroshige Kikura

A supercritical carbon dioxide (S-CO2) gas turbine can generate power at a high cycle thermal efficiency, even at a modest temperature level of 500–550°C. Its high thermal efficiency is attributed to markedly reduced compressor work at the vicinity of the critical point. Furthermore, the reaction between Na and CO2 is milder than that between H2O and Na. Consequently, a more reliable and economically advantageous power generation system is achieved by coupling with a Na cooled fast reactor. In a typical design, the reactor thermal power, a turbine inlet pressure and an inlet temperature are, respectively, 600 MW, 20 MPa and 527°C. In the S-CO2 gas turbine system, a partial cooling cycle is used to compensate a difference in heat capacity for the high-temperature – low-pressure side and the low-temperature – high-pressure side of the recuperators to achieve high cycle thermal efficiency. The flow is divided into two streams before the precooler. One stream goes to recuperator 2 via a main compressor (MC); the other goes to recuperator 1 via a bypass compressor (BC). The performance and integrity of these two compressors are crucial. As described herein, an aerodynamic design of BC is given. The inlet temperature, inlet pressure, exit pressure and mass flow rate are, respectively, 77°C, 8 MPa, 20 MPa and 1392 kg/s. The salient features of this compressor are its compact size and a large bending stress caused by the large mass flow rate. The number of stages is numerous associated with the large enthalpy rise compared with MC. To achieve as high efficiency as possible, not a centrifugal type but an axial type is examined first. The aerodynamic design was conducted using one-dimensional design method, where the loss model of Cohen et al. is used. Its aerodynamic design enables the use of several stages and provides total adiabatic efficiency of 21 and 87%, respectively. Then, CFD analysis was conducted using “FLUENT”. Blade shapes were prepared based on flow angles and chord length obtained in the aerodynamic design. The CO2 properties in a fluid computer dataset “PROPATH” were used. The features of gas velocity distribution and pressure distribution were confirmed to the fundamental knowledge. The value of the calculated flow rate coincided very well with that of the design.

Author(s):  
Ryo Kubo ◽  
Fumio Otomo ◽  
Yoshitaka Fukuyama ◽  
Yuhji Nakata

A CFD investigation was conducted on the total pressure loss variation for a linear nozzle guide vane cascade of a gas turbine, due to the individual film injections from the leading edge shower head, the suction surface, the pressure surface and the trailing edge slot. The results were compared with those of low speed wind tunnel experiments. A 2-D Navier-Stokes procedure for a 2-D slot injection, which approximated a row of discrete film holes, was performed to clarify the applicable limitation in the pressure loss prediction during an aerodynamic design stage, instead of a costly 3-D procedure for the row of discrete holes. In mass flow rate ratios of injection to main flow from 0% to 1%, the losses computed by the 2-D procedure agreed well with the experimental losses except for the pressure side injection cases. However, as the mass flow rate ratio was increased to 2.5%, the agreement became insufficient. The same tendency was observed in additional 3-D computations more closely modeling the injection hole shapes. The summations of both experimental and computed loss increases due to individual row injections were compared with both experimental and computed loss increases due to all-row injection with the mass flow rate ratio ranging from 0% to 7%. Each summation agreed well with each all-row injection result. Agreement between experimental and calculated results was acceptable. Therefore, the loss due to all-row injections in the design stage can be obtained by the correlations of 2-D calculated losses from individual row injections. To improve more precisely the summation prediction for the losses due to the present all-row injections, extensive research on the prediction for the losses due to the pressure side injection should be carried out.


Author(s):  
Mohsen Ghazikhani ◽  
Nima Manshoori ◽  
Davood Tafazoli

An industrial gas turbine has the characteristic that turbine output decreases on hot summer days when electricity demand peaks. For GE-F5 gas turbines of Mashad Power Plant when ambient temperature increases 1° C, compressor outlet temperature increases 1.13° C and turbine exhaust temperature increases 2.5° C. Also air mass flow rate decreases about 0.6 kg/sec when ambient temperature increases 1° C, so it is revealed that variations are more due to decreasing in the efficiency of compressor and less due to reduction in mass flow rate of air as ambient temperature increases in constant power output. The cycle efficiency of these GE-F5 gas turbines reduces 3 percent with increasing 50° C of ambient temperature, also the fuel consumption increases as ambient temperature increases for constant turbine work. These are also because of reducing in the compressor efficiency in high temperature ambient. Steam injection in gas turbines is a way to prevent a loss in performance of gas turbines caused by high ambient temperature and has been used for many years. VODOLEY system is a steam injection system, which is known as a self-sufficient one in steam production. The amount of water vapor in combustion products will become regenerated in a contact condenser and after passing through a heat recovery boiler is injected in the transition piece after combustion chamber. In this paper the influence of steam injection in Mashad Power Plant GE-F5 gas turbine parameters, applying VODOLEY system, is being observed. Results show that in this turbine, the turbine inlet temperature (T3) decreases in a range of 5 percent to 11 percent depending on ambient temperature, so the operating parameters in a gas turbine cycle equipped with VODOLEY system in 40° C of ambient temperature is the same as simple gas turbine cycle in 10° C of ambient temperature. Results show that the thermal efficiency increases up to 10 percent, but Back-Work ratio increases in a range of 15 percent to 30 percent. Also results show that although VODOLEY system has water treatment cost but by using this system the running cost will reduce up to 27 percent.


Author(s):  
Matthew Miguel Virgen ◽  
Fletcher Miller

Two significant goals in solar plant operation are lower cost and higher efficiencies. This is both for general competitiveness of solar technology in the energy industry, and also to meet the US DOE Sunshot Initiative Concentrating Solar Power (CSP) cost goals [1]. We present here an investigation on the effects of adding a bottoming steam power cycle to a solar-fossil hybrid CSP plant based on a Small Particle Heat Exchange Receiver (SPHER) driving a gas turbine as the primary cycle. Due to the high operating temperature of the SPHER being considered (over 1000 Celsius), the exhaust air from the primary Brayton cycle still contains a tremendous amount of exergy. This exergy of the gas flow can be captured in a heat recovery steam generator (HRSG), to generate superheated steam and run a bottoming Rankine cycle, in a combined cycle gas turbine (CCGT) system. A wide range of cases were run to explore options for maximizing both power and efficiency from the proposed CSP CCGT plant. Due to the generalized nature of the bottoming cycle modeling, and the varying nature of solar power, special consideration had to be given to the behavior of the heat exchanger and Rankine cycle in off-design scenarios. Variable guide vanes (VGVs), which can control the mass flow rate through the gas turbine system, have been found to be an effective tool in providing operational flexibility to address the variable nature of solar input. The effect VGVs and the operating range associated with them are presented. Strategies for meeting a minimum solar share are also explored. Trends with respect to the change in variable guide vane angle are discussed, as well as the response of the HRSG and bottoming Rankine cycle in response to changes in the gas mass flow rate and temperature. System efficiencies in the range of 50% were found to result from this plant configuration. However, a combustor inlet temperature (CIT) limit lower than a turbine inlet temperature (TIT) limit leads two distinct Modes of operation, with a sharp drop in both plant efficiency and power occurring when the air flow through the receiver exceeded the (CIT) limit, and as a result would have to bypass the combustor entirely and enter the turbine at a significantly lower temperature than nominal. Until that limit is completely eliminated through material or design improvements, this drawback can be addressed through strategic use of the variable guide vanes. Optimal operational strategy is ultimately decided by economics, plant objectives, or other market incentives.


2014 ◽  
Vol 917 ◽  
pp. 232-243 ◽  
Author(s):  
Sirshendu Guha ◽  
Sudip Kumar Das

A pipe segment system has been used to estimate its inherent resilience properties for the variation of mass flow rate, inlet temperature and inlet pressure. Superheated steam is taken as the process fluid. The magnitude of the resilience decreases from 927.8 kJ/m3s to 43 kJ/m3s and 31.5 kJ/m3s for variation of mass flow rate, inlet pressure and inlet temperature respectively. In this work, a novel methodology has been described for quantification of inherent system resilience and resilience magnitude has been found to be highest (927.8 kJ/m3s) in case of variation of mass flow rate through the pipe segment system. A useful correlation T = Ta(1-e-nL)+Tse-nL has been formulated for estimation of process fluid temperature, T at any pipe length, L.


Energies ◽  
2021 ◽  
Vol 14 (10) ◽  
pp. 2950
Author(s):  
Vinod Kumar ◽  
Liqiang Duan

Coal consumption and CO2 emissions are the major concerns of the 21st century. Solar aided (coal-fired) power generation (SAPG) is paid more and more attention globally, due to the lesser coal rate and initial cost than the original coal-fired power plant and CSP technology respectively. In this paper, the off-design dynamic performance simulation model of a solar aided coal-fired power plant is established. A 330 MW subcritical coal-fired power plant is taken as a case study. On a typical day, three various collector area solar fields are integrated into the coal-fired power plant. By introducing the solar heat, the variations of system performances are analyzed at design load, 75% load, and 50% load. Analyzed parameters with the change of DNI include the thermal oil mass flow rate, the mass flow rate of feed water heated by the solar energy, steam extraction mass flow rate, coal consumption, and the plant thermal efficiency. The research results show that, as DNI increases over a day, the coal saving rate will also increase, the maximum coal saving rate reaches up to 5%, and plant thermal efficiency reaches 40%. It is analyzed that the SAPG system gives the best performance at a lower load and a large aperture area.


Author(s):  
M. Fatouh

This paper reports the results of an experimental investigation on a pilot compression chiller (4 kW cooling capacity) working with R401a and R134a as R12 alternatives. Experiments are conducted on a single-stage vapor compression refrigeration system using water as a secondary working fluid through both evaporator and condenser. Influences of cooling water mass flow rate (170–1900 kg/h), cooling water inlet temperature (27–43°C) and chilled water mass flow rate (240–1150 kg/h) on performance characteristics of chillers are evaluated for R401a, R134a and R12. Increasing cooling water mass flow rate or decreasing its inlet temperature causes the operating pressures and electric input power to reduce while the cooling capacity and coefficient of performance (COP) to increase. Pressure ratio is inversely proportional while actual loads and COP are directly proportional to chilled water mass flow rate. The effect of cooling water inlet temperature, on the system performance, is more significant than the effects of cooling and chilled water mass flow rates. Comparison between R12, R134a and R401a under identical operating conditions revealed that R401a can be used as a drop-in refrigerant to replace R12 in water-cooled chillers.


2021 ◽  
Vol 39 (4) ◽  
pp. 1225-1235
Author(s):  
Ajay K. Gupta ◽  
Manoj Kumar ◽  
Ranjit K. Sahoo ◽  
Sunil K. Sarangi

Plate-fin heat exchangers provide a broad range of applications in many cryogenic industries for liquefaction and separation of gasses because of their excellent technical advantages such as high effectiveness, compact size, etc. Correlations are available for the design of a plate-fin heat exchanger, but experimental investigations are few at cryogenic temperature. In the present study, a cryogenic heat exchanger test setup has been designed and fabricated to investigate the performance of plate-fin heat exchanger at cryogenic temperature. Major parameters (Colburn factor, Friction factor, etc.) that affect the performance of plate-fin heat exchangers are provided concisely. The effect of mass flow rate and inlet temperature on the effectiveness and pressure drop of the heat exchanger are investigated. It is observed that with an increase in mass flow rate effectiveness and pressure drop increases. The present setup emphasis the systematic procedure to perform the experiment based on cryogenic operating conditions and represent its uncertainties level.


2018 ◽  
Vol 22 (1 Part B) ◽  
pp. 487-494 ◽  
Author(s):  
Aminreza Noghrehabadi ◽  
Ebrahim Hajidavaloo ◽  
Mojtaba Moravej ◽  
Ali Esmailinasab

Solar collectors are the key part of solar water heating systems. The most widely produced solar collectors are flat plate solar collectors. In the present study, two types of flat plate collectors, namely square and rhombic collectors are experi?mentally tested and compared and the thermal performance of both collectors is investigated. The results show both collectors have the same performance around noon (?61%), but the rhombic collector has better performance in the morning and afternoon. The values for rhombic and square collectors are approximately 56.2% and 53.5% in the morning and 56.1% and 54% in the afternoon, respectively. The effect of flow rate is also studied. The thermal efficiency of rhombic and square flat plate collectors increases in proportion to the flow rate. The results indicated the rhombic collector had better performance in comparison with the square collector with respect to the mass-flow rate.


Author(s):  
Min Zhang ◽  
Dara W. Childs

Abstract With the increasing demand of the oil & gas industry, many pump companies are developing multiphase pumps, which can handle liquid-gas flow directly without separating the liquid from a mixed flow. The see-through labyrinth seal is one of the popular types of non-contact annular seals that act as a balancing piston seal to reduce the axial thrust of a high-performance centrifugal pump. The see-through labyrinth seal also generates reaction forces that can significantly impact the rotordynamic performance of the pump. Multiphase pumps are expected to operate from pure-liquid to pure-gas conditions. Zhang et al. (2019) conducted a comprehensive experimental study on the performance (leakage and rotordynamic coefficients) of a see-through labyrinth seal under mainly-gas conditions. This paper continues Zhang et al.’s (2019) research and studies the performance of the see-through TOS (tooth-on-stator) labyrinth seal under mainly-liquid conditions. The test seal’s inner diameter, length, and radial clearance are 89.256 mm, 66.68 mm, and 0.178 mm, respectively. The test fluid is a mixture of air and silicone oil (PSF-5cSt), and the inlet GVF (gas volume fraction) varies from zero to 12%. Tests are conducted at an exit pressure of 6.9 bars, an inlet temperature of 39.1 °C, three pressure drops PDs (27.6 bars, 34.5 bars, and 48.3 bars), and three rotating speeds ω (5 krpm, 10 krpm, and 15 krpm). The seal is always concentric with the rotor, and there is no intentional fluid pre-rotation at the seal inlet. The air presence in the oil flow significantly impacts the leakage as well as the dynamic forces of the test seal. The first air increment (increasing inlet GVF from 0% to 3%) slightly increases the leakage mass flow rate, while further air increments steadily decrease the leakage mass flow rate. For all test conditions, the leakage mass flow rate does not change as ω increases from 5 krpm to 10 krpm but decreases as ω is further increased to 15 krpm. The reduction in the leakage mass flow rate indicates that there is an increase in the friction factor, and there could be a highly possible flow regime change as ω increases from 10 krpm to 15 krpm. For ω ≤ 10 krpm, effective stiffness Keff increases as inlet GVF increases. Keff represents the test seal’s total centering force on the pump rotor. The increase of Keff increases the seal’s centering force and would increase the pump rotor’s critical speeds. Ceff indicates the test seal’s total damping force on the pump rotor. For ω ≤ 10 krpm, Ceff first decreases as inlet GVF increases from zero to 3%, and then remains unchanged as inlet GVF is further increased to 12%. For ω = 15 krpm, Keff first increases as inlet GVF increases from zero to 3% and then decreases as inlet GVF is further increased. As inlet GVF increases, Ceff steadily decreases for ω = 15 krpm.


Energies ◽  
2020 ◽  
Vol 13 (5) ◽  
pp. 1105 ◽  
Author(s):  
Carlo Carcasci ◽  
Lapo Cheli ◽  
Pietro Lubello ◽  
Lorenzo Winchler

This paper presents an off-design analysis of a gas turbine Organic Rankine Cycle (ORC) combined cycle. Combustion turbine performances are significantly affected by fluctuations in ambient conditions, leading to relevant variations in the exhaust gases’ mass flow rate and temperature. The effects of the variation of ambient air temperature have been considered in the simulation of the topper cycle and of the condenser in the bottomer one. Analyses have been performed for different working fluids (toluene, benzene and cyclopentane) and control systems have been introduced on critical parameters, such as oil temperature and air mass flow rate at the condenser fan. Results have highlighted similar power outputs for cycles based on benzene and toluene, while differences as high as 34% have been found for cyclopentane. The power output trend with ambient temperature has been found to be influenced by slope discontinuities in gas turbine exhaust mass flow rate and temperature and by the upper limit imposed on the air mass flow rate at the condenser as well, suggesting the importance of a correct sizing of the component in the design phase. Overall, benzene-based cycle power output has been found to vary between 4518 kW and 3346 kW in the ambient air temperature range considered.