scholarly journals Assessment of pulmonary arterial compliance evaluated using harmonic oscillator kinematics

2017 ◽  
Vol 7 (3) ◽  
pp. 666-673
Author(s):  
Yasunobu Hayabuchi ◽  
Akemi Ono ◽  
Yukako Homma ◽  
Shoji Kagami

We hypothesized that KPA, a harmonic oscillator kinematics-derived spring constant parameter of the pulmonary artery pressure (PAP) profile, reflects PA compliance in pediatric patients. In this prospective study of 33 children (age range = 0.5–20 years) with various cardiac diseases, we assessed the novel parameter designated as KPA calculated using the pressure phase plane and the equation KPA = (dP/dt_max)2/([Pmax – Pmin])/2)2, where dP/dt_max is the peak derivative of PAP, and Pmax – Pmin is the difference between the minimum and maximum PAP. PA compliance was also calculated using two conventional methods: systolic PA compliance (sPAC) was expressed as the stroke volume/Pmax – Pmin; and diastolic PA compliance (dPAC) was determined according to a two-element Windkessel model of PA diastolic pressure decay. In addition, data were recorded during abdominal compression to determine the influence of preload on KPA. A significant correlation was observed between KPA and sPAC (r = 0.52, P = 0.0018), but not dPAC. Significant correlations were also seen with the time constant (τ) of diastolic PAP (r = −0.51, P = 0.0026) and the pulmonary vascular resistance index (r = −0.39, P = 0.0242). No significant difference in KPA was seen between before and after abdominal compression. KPA had a higher intraclass correlation coefficient than other compliance and resistance parameters for both intra-observer and inter-observer variability (0.998 and 0.997, respectively). These results suggest that KPA can provide insight into the underlying mechanisms and facilitate the quantification of PA compliance.

2018 ◽  
Vol 1 (3) ◽  
Author(s):  
Shuo Qi ◽  
Jianmin Cao ◽  
Xin Pang ◽  
Yongbin Duan

Objective With the increase of social pressure and the unreasonable diet structure, the proportion of the overweight and obese people is increasing. Obesity is an important factor causing many chronic diseases, such as type II diabetes, atherosclerosis, hypertension, hyperlipidemia and so on. Epidemiological studies show that the proportion of obese people in China is still high. It has seriously hindered the further development of the Chinese health. The combination of diet and exercise is effective for reducing the weight. However, this method isn’t effective for overweight and obese people. Therefore, the way to reduce weight has become a central issue for many researchers. Studies have shown that the exposure of hypoxia condition can decrease weight and exercise can promote energy consumption. Exercises in a hypoxic environment provide a new way of thinking for the prevention and treatment of obesity and national fitness, and which are also a research hotspot for weight loss. Methods The study enrolled 40 young women with overweight/obese subjects, aged 18-47 years, with no abnormal physical examination. The criterion for overweight is BMI ≥ 24 and the criterion for obesity is BMI ≥ 28. All subjects were paired according to their body weight, divided into hypoxia group and normoxia group and they exercised for 6 weeks, 3 times a week, every other day. The content of the exercise intervention includes 30 minutes strength training and 30minutes endurance training. Strength training is in front and endurance training is in the back. There are 5 minutes of warm-up and finishing activities before and after training. Strength training uses dumbbells, chooses 12RM weight, exercise with 8 actions, which are dead lift, upright row, squat, shoulder press, calf Jump, advance junge, biceps curl and triceps extension, each action 2 Group, rest between groups for 30s. Endurance training uses a treadmill with a slope of 0°, and the speed is adjusted according to the target heart rate interval. The calculation method of the target heart rate interval is (220-age)×60%~(220-age)×70%. Meanwhile, the hypoxia group wears inhaled atmospheric hypoxia equipment and they exercised in a low-oxygen condition. The oxygen content of the inhaled mixed gas is 16%; the normoxia group exercises under the normal oxygen condition. Nutritional education was given to all subjects prior to the start of exercise intervention and the personal diet was controlled as much as possible, but diet was not restricted during the intervention. Body weight was measured before and after intervention. Fasting venous blood was taken. Blood glucose (GLU), insulin (INS) and glycated hemoglobin (GHb) were measured. Insulin resistance index (HOMA-IR) was calculated. All test results were expressed as mean ± standard deviation, non-parametric Mann-Whitney U test was used for comparison between groups, and non-parametric Wilcoxon matching was used for symbol level test. The significance level was P<0.05, the level of very significant was P<0.01. Results  After intervention, the fasting blood glucose level of the hypoxia group and normoxia group decreased and the hypoxia group decreased more, but there was no significant difference compared with before intervention (P>0.05). There was no significant difference between the rate and the normoxia group (P>0.05). After intervention, the GHb levels in the hypoxia group and the normoxia group decreased, but there was a significant difference between the hypoxia group and the hypoxia group (P<0.05). The difference between the normoxia group was not significant (P>0.05). There was no significant difference in the rate of GHb change between the oxygen exercise group and the normoxia group (P>0.05). After intervention, the fasting INS levels in the hypoxia group and the normoxia group decreased, but there was a significant difference between the hypoxia group and the hypoxia group (P<0.05), and the difference between the normoxia group was not significant (P>0.05). There was no significant difference in the rate of fasting INS between the hypoxia group and the normoxia group (P>0.05). The HOMA-IR of the hypoxia group and the normoxia group decreased after intervention, but there was significant difference between the hypoxia group and the hypoxia group (P<0.05) and the difference between the normoxia group was not significant (P>0.05). The HOMA-IR rate of hypoxia exercise was not significantly different from that of normoxia group (P>0.05). Conclusions Compared with the normoxia group, the hypoxia group has a more improved glycosylated hemoglobin and insulin resistance index. It suggests that the exercise intervention of the hypoxia condition may be more effective in treating obesity and preventing chronic diseases.


2013 ◽  
Vol 24 (5) ◽  
pp. 482-486 ◽  
Author(s):  
Marili Doro Andrade Deonizio ◽  
Gilson Blitzkow Sydney ◽  
Antonio Batista ◽  
Roberto Pontarolo ◽  
Paulo Ricardo Bittencourt Guimarães ◽  
...  

This study evaluated the influence of apical patency, root filling removal technique and cleaning of the apical foramen, concerning the amount of debris extruded during root canal retreatment. Forty mandibular incisors were randomly assigned to 4 groups - GIM (n=10), GIIM (n=10), GIPT (n=10) and GIIPT (n=10), which were named according to leaving (I) or not (II) apical patency during canal preparation and filling removal technique (manual - M or ProTaper system - PT). After filling material removal, each specimen of each group had the apical foramen cleaned by sizes 15, 20 and 25 instruments, generating 12 subgroups: GIM15, GIM20, GIM25, GIIM15, GIIM20, GIIM25, GIPT15, GIPT20, GIPT25, GIIPT15, GIIPT20 and GIIPT25. Extruded filling debris was collected by a Milipore filtration system, an HV-durapore, 0.45 µm pore filter with a 25 mm diameter. The filters were weighed before and after the collection on an analytical scale (10–5 g), and the difference was calculated. The mean weight of extruded filling debris was analyzed statistically by Kruskal-Wallis and Friedman ANOVA tests (α=0.05). The mean values found in the groups (in mg) were: GIM (0.95±0.94), GIIM (0.47±0.62), GIPT (0.30±0.31) and GIIPT (0.32±0.44). There was no statistically significant difference among any of the groups or subgroups (p>0.05). ProTaper provided the smallest amount of extruded filling material, regardless of presence or absence of apical patency, followed by manual technique, without and with apical patency. Additional amounts of debris were collected during cleaning of the apical foramen, regardless of the instrument, presence/absence of patency or root filling removal technique.


1999 ◽  
Vol 276 (2) ◽  
pp. H424-H428 ◽  
Author(s):  
N. Stergiopulos ◽  
P. Segers ◽  
N. Westerhof

We determined total arterial compliance from pressure and flow in the ascending aorta of seven anesthetized dogs using the pulse pressure method (PPM) and the decay time method (DTM). Compliance was determined under control and during occlusion of the aorta at four different locations (iliac, renal, diaphragm, and proximal descending thoracic aorta). Compliance of PPM gave consistently lower values (0.893 ± 0.015) compared with the compliance of DTM (means ± SE; r = 0.989). The lower compliance estimates by the PPM can be attributed to the difference in mean pressures at which compliance is determined (mean pressure, 81.0 ± 3.6 mmHg; mean diastolic pressure, over which the DTM applies, 67.0 ± 3.6 mmHg). Total arterial compliance under control conditions was 0.169 ± 0.007 ml/mmHg. Compliance of the proximal aorta, obtained during occlusion of the proximal descending aorta, was 0.100 ± 0.007 ml/mmHg. Mean aortic pressure was 80.4 ± 3.6 mmHg during control and 102 ± 7.7 mmHg during proximal descending aortic occlusion. From these results and assuming that upper limbs and the head contribute as little as the lower limbs, we conclude that 60% of total arterial compliance resides in the proximal aorta. When we take into account the inverse relationship between pressure and compliance, the contribution of the proximal aorta to the total arterial compliance is even more significant.


2012 ◽  
Vol 2 (2) ◽  
pp. 77-80
Author(s):  
Md Abu Taher ◽  
Nuzhat Tasmin ◽  
AS Mohiuddin ◽  
Md Mohit Ul Alam ◽  
Md Mofazzal Sharif ◽  
...  

This observational type of descriptive study was carried out in the Department of Radiology and Imaging, BIRDEM selecting 70 Bangladeshi pregnant babies with the aim to find out the normogram of foetal middle cerebral artery Doppler flow velocity indices and correlation between Doppler flow velocity indices [Resistance Index (RI), Pulsatility Index (PI), Systolic/Diastolic ratio (S/D) & Peak Systolic Velocity (PSV)] of foetal middle cerebral artery and gestational age in normal pregnancies of 20 to 40 weeks. It was observed that RI, PI and S/D were decreased with the advance of gestational age but PSV was increases with the advance of gestational age. Statistical analyses showed there were significant difference between mean PSV, RI and PI before and after 25 weeks of gestation. No significant difference was found between mean S/D before and after 25 weeks of gestation. It was observed from Correlation analysis between Doppler indices with independent gestational age that all the Doppler indices of foetal middle cerebra artery was positively correlated with the whole gestation period. The statistical analysis showed only PSV and RI were significantly correlated with the gestational age. Simple regression analysis between dependent Doppler index with independent gestational age before and after 25 weeks revealed that all the Doppler indices had positive relationship with the corresponding gestational age but relationship between PSV and PI (before 25 weeks) with their corresponding gestational ages were only statistically significant.DOI: http://dx.doi.org/10.3329/birdem.v2i2.12306 Birdem Med J 2012; 2(2) 77-80


2008 ◽  
Vol 20 (3) ◽  
Author(s):  
Samuel Setiawan ◽  
Edeh Rolleta Haroen ◽  
Dede Hadidjah

In administering fluoride through drinking water there is the risk of overdose, higher cost and inadequate availability of drinking water containing fluoride in developing countries like Indonesia. A safe fluoride source is contained in toothpaste. The purpose of this research was to obtain data concerning difference in saliva pH before and after brushing with toothpaste containing fluoride and without toothpaste. The research method used was the quasi-experimental method. Samples were collected by the way of purposive sampling, conducted on 43 male and female research subjects. The data were analyzed by statistical analysis using the t test at 95% confidence level. In this research a control group consisting of 43 people was used. Research results indicated that the average saliva pH before brushing was 7.174; after brushing with fluoride containing toothpaste salivary pH was 7.593. Result research of brushing without toothpaste showed an average saliva of 7.163 before brushing and 7.379 after brushing without toothpaste. The average changes in saliva pH before and after brushing using fluoride containing toothpaste was 0.216. The conclusion of this research was that there was significant difference in saliva pH before and after brushing with toothpaste containing fluoride; there was significant difference in saliva pH before and after brushing without toothpaste, and there was significant difference in saliva pH before and after brushing with toothpaste containing fluoride and without toothpaste.


2021 ◽  
Author(s):  
Asep Arifin Senjaya ◽  
Ni Made Sirat ◽  
I Nyoman Wirata ◽  
Ni Ketut Ratmini

Dental healthcare is very important since dental and oral hygiene should be maintained. Statistics showed that more than 80% of children in developed and developing countries suffer from dental disease. This study aimed to see the safety of OHIS (Oral Hygiene Index Simplified) in primary school students who got and did not get little dentist cadre training in Bangli Regency in 2019. The study was done in an experimental design: pre and post-test with control design, which was conducted in August-September 2019. The sample in this study is 366 students. The difference in OHIS scores before and after treatment in the control group and treatment group was carried out by the bivariate Mann Whitney U Test. The results of the study showed that before dental health training was conducted, there were 54.3% of primary school students in the treatment group with good OHIS score criteria, and after the training was carried out as many as 98.4% of the students in the treatment group had a good OHIS. Additionally, prior to the training, 57.5% of the control group had fair OHIS criteria score. Then, after the training was carried out, 73.7% of the control group had good OHIS score. Hence, the study concluded that there was a significant difference in the OHIS of primary school students who got little doctor training prior to and after the training. Also, there was a significant difference in the OHIS of the students who did not get such treatment before and after the training.


2020 ◽  
Vol 1 (2) ◽  
pp. 22-29
Author(s):  
Yulni Yulni ◽  
Veni Hadju ◽  
Burhanuddin Bahar ◽  
Citrakesumasari Citrakesumasari ◽  
Rahayu Indriasari ◽  
...  

The aim of this study was to determine the effect of Moringa oleifera leaf extract supplements, Moringa oleifera leaf extract plus royal jelly and placebo on hemoglobin levels in anemic pregnant women. This research is a randomized controlled double blind design study which was conducted in Polombangkeng Utara District, Takalar Regency for 2 months. The subjects of this study were pregnant women with anemia, the majority of which were 20-35 years old, primigravida parity, income less than UMR, unemployment, higher education, pregnancy distance of more than 2 years with p value> 0.05. Then divided into three groups, namely Moringa capsules plus royal jelly (KRJ) (n = 24), Moringa capsules (KTR) (n = 24) and placeco (PLC) (n = 21). Before and after the intervention, measurements of hemoglobin levels were carried out using the Hemocue tool and interviewing the characteristics of the respondents. The results showed that the average Hb level increased from each group (mean SD): KRJ 10.06 ± 0.75 to 11.42 ± 1.23, P = 0.001, KTR 10.40 ± 0.46 to 11.15 ± 0 , 90 P = 0.001 and PLC 10.43 ± 0.42 becomes 11.14 ± 0.88 P = 0.002. but there was no significant difference from the difference in the average increase in Hb levels in the three groups, but there was a tendency that KRJ was superior to the KTR and PLC groups with an increase of 1.36 gr / dl, KTR 0.75 gr / dl and PLC 0.71 gr / dl. So it can be concluded that KRJ is better than KTR and PLC in increasing Hb levels in anemic pregnant women in Takalar Regency.


2020 ◽  
Vol 21 (6) ◽  
Author(s):  
Alimohammad Bananzadeh ◽  
Seyed Vahid Hosseini ◽  
Hajar Khazraei ◽  
Mohammad Mehdi Lashkarizadeh ◽  
Leila Ghahramani ◽  
...  

Background: Bariatric surgery has resulted in body weight loss, which claimed by surgery removal specific parts of the stomach with enzyme or sleeve gastrectomy. Objectives: The aim of this study is to determine weight loss and endocrine changes by 12-week fundus resection and sleeve gastrectomy in rabbits. Methods: Twenty-one rabbits, weighing 2.5 - 3.5 kg, were divided into three groups (n = 7): sleeve gastrectomy, experimental fundus resection, and sham group. The weight of rabbits and total ghrelin and leptin levels in the plasma before and after surgery were measured in 12 weeks. Statistical analyses were performed using the Kruskal-Walis test for comparison of the means between the groups, and the difference after months in one group was assayed by Friedman test. Results: The results showed sleeve gastrectomy had a significant weight loss after one month when compared to fundus resection and sham-operated controls (P = 0.008). There was no significant difference in the ghrelin levels after these surgeries, but leptin levels decreased significantly after the fundectomy (P = 0.025). Conclusions: Sleeve gastrectomy is more efficient than the fundus resection in weight loss. It could be suggested as a new option in metabolic disorders due to the high level of leptin.


2001 ◽  
Vol 90 (4) ◽  
pp. 1481-1488 ◽  
Author(s):  
Douglas R. Hamilton ◽  
Gwyneth Devries ◽  
John V. Tyberg

Previously, we developed a balloon transducer to measure the constraint of the pericardium (i.e., pericardial pressure) on the surface of the heart. It was validated physiologically in that it was shown to measure a pressure equal to the difference between the left ventricular end-diastolic pressure measured before and after pericardiectomy at the same left ventricular volume. To define its static operating characteristics, we loaded the balloon nonuniformly with weights that covered fractions of the balloon surface and found that the balloon accurately recorded the average stress if the stress was applied over at least 23% of its surface. To test its performance when curved, we placed it in large and small cylinders (minimum diameter 31 mm) and found that the balloon accurately recorded the stress. To define its dynamic operating characteristics, we applied sinusoidal stresses and found that its frequency response was limited only by that of the connecting catheter. When better dynamic response is required, we introduce a micromanometer-tipped catheter to obtain a unity-gain frequency response that is flat to 200 Hz.


Sensors ◽  
2020 ◽  
Vol 20 (3) ◽  
pp. 577 ◽  
Author(s):  
Shunrou Fujiwara ◽  
Shinpei Sato ◽  
Atsushi Sugawara ◽  
Yasumasa Nishikawa ◽  
Takahiro Koji ◽  
...  

The aim of this study was to investigate whether variation in gait-related parameters among healthy participants could help detect gait abnormalities. In total, 36 participants (21 men, 15 women; mean age, 35.7 ± 9.9 years) performed a 10-m walk six times while wearing a tri-axial accelerometer fixed at the L3 level. A second walk was performed ≥1 month after the first (mean interval, 49.6 ± 7.6 days). From each 10-m data set, the following nine gait-related parameters were automatically calculated: assessment time, number of steps, stride time, cadence, ground force reaction, step time, coefficient of variation (CV) of step time, velocity, and step length. Six repeated measurement values were averaged for each gait parameter. In addition, for each gait parameter, the difference between the first and second assessments was statistically examined, and the intraclass correlation coefficient (ICC) was calculated with the level of significance set at p < 0.05. Only the CV of step time showed a significant difference between the first and second assessments (p = 0.0188). The CV of step time also showed the lowest ICC, at <0.50 (0.425), among all parameters. Test–retest results of gait assessment using a tri-axial accelerometer showed sufficient reproducibility in terms of the clinical evaluation of all parameters except the CV of step time.


Sign in / Sign up

Export Citation Format

Share Document