EXPERIMENTAL STUDIES OF THE HEATING TEMPERATURE OF THE GREENHOUSE RADIATOR INSTALLATIONS

2020 ◽  
Vol 15 (1) ◽  
pp. 76-80
Author(s):  
Nadezhda Kondrat'eva ◽  
Dmitriy Filatov ◽  
Pavel Terent'ev ◽  
Bulat Ziganshin

The thermal regime of plants determines the temperature of the environment, the evaporation of moisture by plants, and the heating of plants by radiation from irradiation plants. Today, induction and LED greenhouse irradiators are promising for replacing irradiators with sodium lamps in terms of energy efficiency. Experimental studies were performed to assess the possibility of proximity of irradiators with induction lamps and LED irradiators to plants to increase their level of irradiation, in comparison with sodium radiation sources. When setting up the experiment, a complex was used, including a Fluke ti32 thermal imager, PHO-250-2-M linear autotransformer, 220V power supply, and a greenhouse irradiator. Processing of the measurement results was carried out in the Fluke SmartView 3.1 program. The heating temperature was determined when reaching the nominal mode, with the nominal mode of operation of the irradiators, with a change in the supply voltage level. Sodium and induction irradiators heat up to a maximum temperature 10 times faster than LED ones. The heating temperature of optical radiation sources with sodium lamps is 5 times higher than LED and 2.5 times higher than induction. A change in the supply voltage level affects the heating temperature of the sodium irradiator with electromagnetic ballasts, the heating temperature of sodium and induction irradiators with electronic ballasts, as well as LED irradiators, remains unchanged and equal to the nominal value at a supply voltage level of ± 10% of Unom.. Low heating temperatures of induction and LED irradiators can reduce the height of their suspension and bring them closer to plants, which will increase the irradiation of plants by increasing the level of illumination or reduce the power of irradiators, that is, increase the energy efficiency of irradiation systems

2020 ◽  
pp. 85-88 ◽  
Author(s):  
Nadezhda P. Kondratieva

The article describes the results of the study concerning the effect of the voltage level on current harmonic composition in greenhouses irradiators. It is found that its change affects the level of current harmonics of all types of the studied greenhouse irradiators. With decrease of nominal supply voltage by 10 %, the total harmonic distortion THDi decreases by 9 % for emitters equipped with high pressure sodium lamps (HPSL), by 10 % for emitters with electrode-less lamps and by 3 % for LED based emitters. With increase of nominal supply voltage by 10 %, THDi increases by 23 % for lighting devices equipped with HPSL, by 10 % for irradiators with electrode-less lamps and by 3 % for LED based emitters. Therefore, changes of supply voltage cause the least effect on the level of current harmonics of LED based emitters and then the emitters with electrode-less lamps. Change of the level of supply voltage causes the greatest effect on the level of current harmonics of HPSL based irradiators. Mathematical models of dependence of THDi on the level of supply voltage for greenhouse emitters equipped with LED, electrode-less lamps and HPSL lamps were formulated. These mathematical models may be used for calculations of total current when selecting transformers and supply cable lines for greenhouse lighting devices, for design of new or reconstruction of existing irradiation systems of greenhouse facilities, and for calculation of power losses in power supply networks of greenhouse facilities during feasibility studies for energy saving and energy efficiency increasing projects.


Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 713
Author(s):  
Yanyan Peng ◽  
Qunchao Lin ◽  
Manchao He ◽  
Chun Zhu ◽  
Haijiang Zhang ◽  
...  

In rock engineering, it is of great significance to study the failure mechanical behavior of rocks with holes. Using a combination of experiment and infrared detection, the strength, deformation, and infrared temperature evolution behavior of marble with elliptical holes under uniaxial compression were studied. The test results showed that as the vertical axis b of the ellipse increased, the peak intensity first decreased and then increased, and the minimum value appeared when the horizontal axis was equal to the vertical axis. The detection results of the infrared thermal imager showed that the maximum temperature, minimum temperature, and average temperature of the observation area in the loading stage showed a downward trend, and the range of change was between 0.02 °C and 1 °C. It was mainly due to the accumulation of energy in the loading process of the rock sample that caused the surface temperature of the specimen to decrease. In the brittle failure stage, macroscopic cracks appeared on the surface of the rock sample, which caused the energy accumulated inside to dissipate, thereby increasing the maximum temperature and average temperature of the rock sample. The average temperature increase was about 0.05 °C to about 0.19 °C. The evolution of infrared temperature was consistent with the mechanical characteristics of rock sample failure, indicating that infrared thermal imaging technology can provide effective monitoring for the study of rock mechanics. The research in this paper provides new ideas for further research on the basic characteristics of rock failure under uniaxial compression.


Energies ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2703
Author(s):  
Robert Sekret ◽  
Przemysław Starzec

The paper presents the investigation of a prototype cold accumulator using water–ice latent heat for the cold storage process. The concept of the cold accumulator was based on a 200-L-capacity cylindrical storage tank in which spherical capsules filled with water were placed. Beds of polypropylene capsules with diameters of 80 mm, 70 mm, and 60 mm were used in the tests. The cold accumulator operated with a water–air heat pump. Based on the test results, the following parameters were calculated: the cooling capacity, cooling power, energy efficiency of the cold storage, and energy efficiency ratio (EER) of the accumulator. The obtained measurement results were described with mathematical relationships (allowing for measurement error) using criterial numbers and the developed “Research Stand Factor Number” (RSFN) index. It has been found that, for the prototype cold accumulator under investigation, the maximum values of the cooling capacity (17 kWh or 85.3 kWh per cubic meter of the accumulator), energy efficiency (0.99), and EER (4.8) occur for an RSFN of 144·10−4. The optimal conditions for the operation of the prototype cold accumulator were the closest to laboratory tests conducted for a bed with capsules with a diameter of 70 mm and a mass flow of the water–glycol mixture flowing between the accumulator and the heat pump of 0.084 kg/s. During the tests, no significant problems with the operation of the prototype cold accumulator were found.


2021 ◽  
Vol 11 (8) ◽  
pp. 3444
Author(s):  
Sergey A. Lavrenko ◽  
Dmitriy I. Shishlyannikov

The authors focus on the process of potash ore production by a mechanized method. They show that currently there are no approved procedures for assessing the performance of heading-and-winning machines operating in the conditions of potash mines. This causes difficulties in determining the field of application of heading-and-winning machines, complicates the search for implicit technical solutions for the modernisation of existing models of mining units, prohibits real-time monitoring of the stability of stope-based technological processes and makes it difficult to assess the performance of the services concerning mining enterprises. The work represents an aggregate assessment of the performance of heading-and-winning machines for potash mines by determining complex indicators describing the technological and technical levels of organising the work in stopes. Such indicators are the coefficients of productivity and energy efficiency, respectively. Experimental studies have been carried out in the conditions of the potash mine of the Verkhnekamskoye potassium-magnesium salt deposit to assess the performance of the latest and most productive Ural-20R heading-and-winning machines manufactured in Russia. Using the above methodological approaches, this paper shows that the unsatisfactory technological performance of the studied machine is due to the low productivity of the mine district transport. The average productivity coefficient was 0.29. At the same time, high values of the energy efficiency coefficient show that the productivity of the machine is on par with design conditions.


2020 ◽  
Vol 23 (2) ◽  
pp. 48-51
Author(s):  
V. KONDRATENKO ◽  
◽  
V. KALYNYCHENKO ◽  

Mine drainage systems, which are used at the main drainage of mining enterprises, have a drive capacity of up to 1600kW. To reduce non-productive energy losses, as well as for the continuous operation of the mining company, mine pumps must be energy efficient and reliable. Analysis of downtime of drainage systems shows that the weak point is the unloading device. This fact can lead not only to the failure of the pumping unit, but also to possible prolonged downtime of the mine. The main disadvantage of the existing disk unloading devices of mine pumps is their low reliability and low service life, due to the rapid wear of the components of the unloading unit. The most vulnerable elements of the unloading device are the unloading rings. The need for frequent replacement and adjustment of the elements of the discharge unit is associated with disassembly and assembly of the pump directly in the pump chamber. Such actions require significant costs of unproductive manual labor of service personnel, and rapid wear of parts of the unloading device necessitates their constant replenishment. Malfunctions in the unloading device can cause significant pump failures. To increase the reliability and energy efficiency of mine drainage systems, the method of control of the unloading device was used. During the experimental studies it was found that cavitation phenomena during the operation of pumping units are absent and, accordingly, can not be the cause of wear of the elements of the unloading unit. When the pumps are operating in steady state, the displacement of the rotors was monitored for 3-4 hours on each pump unit. After data processing, it was obtained that the wear of the surface of the unloading rings occurs at a rate of 0.05-0.15mm in one hour. To determine the wear of the rings of unloading during start-up - stop of the pump, at first the indicators of measuring devices at the established mode of operation of the pump unit were fixed. Then the pump was turned off and on again. After starting the pump unit, we made sure that the operating mode of the unloading device did not change and compared the readings of the shaft position indicator before stopping and after starting the pump. From the measurements made it followed that stopping and starting the pump does not lead to noticeable wear of the unloading device. Therefore, it can be assumed that mainly the wear of the discharge rings occurs during the steady operation of the pump unit.


2014 ◽  
Vol 23 (01) ◽  
pp. 1450004 ◽  
Author(s):  
XIAOBO XUE ◽  
XIAOLEI ZHU ◽  
QIFENG SHI ◽  
LENIAN HE

In this paper, a 12-bit current-steering digital-to-analog converter (DAC) employing a deglitching technique is proposed. The deglitching technique is realized by lowering the voltage swing of the control signal as well as by using a method of glitch counteraction (GC). A new switch–driver structure is designed to enable the effectiveness of the GC and provide sufficient driving capability under a low supply voltage. Moreover, the control signal's rise/fall asymmetry which increases the glitch error can be suppressed by using the proposed switch–driver structure. The 12-bit DAC is implemented in 180 nm CMOS technology. The measurement results show that the spurious free dynamic range (SFDR) at low signal frequency is 78.8 dB, and it is higher than 70 dB up to 60 MHz signal frequency at 400 MS/s. The measured INL and DNL are both less than ±0.6 LSB.


2019 ◽  
Vol 104 ◽  
pp. 01006
Author(s):  
Maxim Filimonov ◽  
Nicolay Karnaukhov ◽  
Eugeny Lukyanov ◽  
Dmitry Smyatsky ◽  
Roman Mironenko

this article the energy efficient frequency way of starting of production mechanisms electrical drive with low power asynchronous motors (from 90 Wt to 5 kWt) is proposed. To provide this With the goal of electrical losses decreasing during asynchronous motor starting the Pontryagin Maximum Principle have been applied by the authors when analysing of two-mass model of production mechanism frequency controlled electrical drive. In result of calculations for frequency controlled electrical drive of production mechanism with 90 Wt power asynchronous motor of the model 4AA50A2 Dependencies of amplitude and frequency of supply voltage by the time are obtained. These dependencies confirm possibility of decreasing the electrical power losses with different values of motor shaft load torques. In compare with the other ways of asynchronous motor starting (for example U/f=const) they allow to decrease the electrical losses more then two times in nominal mode.


2021 ◽  
pp. 187-190
Author(s):  
D.А. Hakimov ◽  
I.V. Zhuk ◽  
M.K. Kievets

Experimental studies have been carried out to determine the sensitivity of a mobile scintillation gamma-spectrometer to radon-222 in mineral water samples for the selected measurement geometry and the minimum measurable activity of radon-222 in such samples. The measurement results of radon content in mineral water samples obtained using such gamma-spectrometer are presented too.


Metrologiya ◽  
2020 ◽  
pp. 48-62
Author(s):  
Vladimir A. Larionov

Existing methods of metrological self-monitoring of measuring sensors for temperature and pressure of technological industries are considered. The analysis of methods of metrological self-checking of strain gauge pressure sensors is carried out. Method is proposed based on measuring the supply voltage and voltage on the measuring diagonal of the bridge. The temperature of the strain gauge bridge is determined using a semiconductor thermistor installed near the bridge. This allows you to adjust the measured value of the total resistance of the bridge from the temperature of the bridge. With aging and exposure to external conditions, a change in the overall resistance of the bridge can be used to judge the error of the sensor. An experimental sample of the sensor was made. The failure of the strain gage bridge is simulated by parallel connection of an additional resistor to one of the shoulders of the bridge. Experimental studies have shown that modern technical means make it possible to assess the effect of changes in the total bridge resistance on the sensor error.


Author(s):  
V.Yu. Lavrinenko ◽  
Yu.A. Lavrinenko ◽  
R.S. Fayruzov ◽  
A.S. Ayrapetyan ◽  
A.S. Kirsanov

The results of experimental studies of flow curves of 32CrB4, 20G2R and 1.4034 (analogue of 40Kh13 steel) steels at different heating temperature of workpieces are presented. Rational intervals of preliminary lowtemperature heating of workpieces made of studied steels are obtained. It allows to decrease forces during cold forging, loads on the working tool and to increase of tool life time up to 2 times.


Sign in / Sign up

Export Citation Format

Share Document