scholarly journals Arc extinction with nitrogen at 1-40 bar in a puffer-like contact configuration

2021 ◽  
Vol 8 (1) ◽  
pp. 14-18
Author(s):  
Nina Støa-Aanensen ◽  
Camilla Espedal ◽  
Oddgeir Rokseth ◽  
Erik Jonsson ◽  
Magne Runde

To develop cost-efficient subsea switchgear for large sea depths, the extinction of arcs under high filling pressures must be understood. In this work, arc-extinction experiments have been performed with a puffer-like contact configuration using nitrogen at different filling pressures as the current interruption medium. The main finding is that, for the given contact configuration, the currentinterruption capability was lower at 20 and 40 barabs than at 1 and 10 barabs. While higher pressures result in higher cooling flow rates and longer flow times given the same puffer volume, compression spring and nozzle geometry; it does not necessarily improve the arc-extinction capability. This is probably because higher filling pressures increase the arc voltage and total energy dissipated in the arcing zone. Because the filling pressure greatly influences the flow characteristics, the puffer design should be optimized for each pressure level.

Author(s):  
Yo Han Jung ◽  
Young Uk Min ◽  
Jin Young Kim

This paper presents a numerical investigation of the effect of tip clearance on the suction performance and flow characteristics at different flow rates in a vertical mixed-flow pump. Numerical analyses were carried out by solving three-dimensional Reynolds-averaged Navier-Stokes equations. Steady computations were performed for three different tip clearances under noncavitating and cavitating conditions at design and off-design conditions. The pump performance test was performed for the mixed-flow pump and numerical results were validated by comparing the experimental data for a system characterized by the original tip clearance. It was shown that for large tip clearance, the head breakdown occurred earlier at the design and high flow rates. However, the head breakdown was quite delayed at low flow rate. This resulted from the cavitation structure caused by the tip leakage flow at different flow rates.


Vestnik MGSU ◽  
2019 ◽  
pp. 621-633 ◽  
Author(s):  
Tatyana A. Rafalskaya ◽  
Valery Ya. Rudyak

Introduction. Being used in various industries, heat exchangers most often work under conditions of variable coolant flows and temperatures. At the same time, the existing theories of calculating the heat exchanger operation modes are based on the use of constant unitless parameters at any operation mode. Taking into account the effect of coolant rates on the heat transfer coefficient of the heat exchangers, the given relations are bound to specific types of heat exchangers and can only be used at constant coolant temperatures. The purpose of this study is to obtain expressions for determining the effect of coolant flow rates on the variable heat exchanger parameter. Materials and methods. The main variable operation modes for water-to-water heat exchangers used in heat supply systems are determined. Using simulation in the PTC Mathcad software, dependencies describing the change in the heat exchanger parameter for all the considered variable operation modes are defined. This made it possible to obtain a general formula for the change in the heat exchanger parameter for varying coolant flow rates. Coefficients in this formula take into consideration the effect of coolant temperatures, which cannot be known when calculating variable conditions, especially when the interconnected heat exchangers are operating. Results. To test applicability of the existing relations describing the change in the heat exchanger parameter and of obtained formula, a large number of heat exchangers is calculated at variable operation modes. Comparison with the simulation results shows that the correlations of heat exchanger theories work well at the mode with constant coolant temperatures only, while their use at other operation modes can lead to large calculation errors. Conclusions. The obtained formula allows finding the effect of coolant flow rates on the variable heat exchanger parameter. The formula can be used to predict the operation modes of large systems including a large number of various-type heat exchangers.


1990 ◽  
Vol 112 (2) ◽  
pp. 308-310 ◽  
Author(s):  
J. Nordquist ◽  
S. Abrahamson ◽  
J. Wechkin ◽  
J. Eaton

An experimental study was performed in a simplified turbine disk cavity consisting of a single disk rotating near a stationary flat plate, bounded radially by an axial seal fixed to the plate. The disk Reynolds number was 6.2 × 105. Cooling flow was supplied axially at a dimensionless radius of 0.33. Flow visualization showed boundary layers on both the rotating and stationary disks with the core between the layers rotating in solid body motion. At intermediate cooling flow rates, large vortical structures aligned with the disk spin axis and spanning the core were observed.


Author(s):  
Can Kang ◽  
Ning Mao ◽  
Chen Pan ◽  
Yang Zhu ◽  
Bing Li

A low-specific-speed centrifugal pump equipped with long and short blades is studied. Emphasis is placed on the pump performance and inner flow characteristics at low flow rates. Each short blade is intentionally shifted towards the back surface of the neighboring long blade, and the outlet parts of the short blades are uniformly shortened. Unsteady numerical simulation is conducted to disclose inner flow patterns associated with the modified design. Thereby, a comparison is enabled between the two schemes featured by different short blades. Both practical operation data and numerical results support that the deviation and cutting of the short blades can eliminate the positive slope of pump head curve at low flow rates. Therefore, the modification of short blades improves the pump operation stability. Due to the shortening of the outlet parts of the short blades, velocity distributions between impeller outlet and radial diffuser inlet exhibit explicitly altered circumferential flow periodicity. Pressure fluctuations in the radial diffuser are complex in terms of diversified periodicity and amplitudes. Flow rate influences pressure fluctuations in the radial diffuser considerably. As flow rate decreases, the regularity of the orbit of hydraulic loads exerted upon the impeller collapses while hydraulic loads exerted upon the short blades remain circumferentially periodic.


2013 ◽  
Vol 446-447 ◽  
pp. 1546-1551
Author(s):  
Harshit Saxena ◽  
Arpit Santoki ◽  
Nimish Awalgaonkar ◽  
Arpan Jivani ◽  
Ganni Gowtham ◽  
...  

Solar Parabolic Trough collectors are commonly used to harness the solar power for power generating applications involving high temperatures. In the given paper study we have made use of the SolTrace software which uses the Monte Carlo algorithm for finding out the radiation received on the absorber tube of the collector. The computational study was performed taking into account the solar radiation received at Vellore city in India (12.92oN, 79.13oE) as on 16th February 2013. Further a 3D model of the absorber tube used in the parabolic trough collector was created and meshed with the help of the Ansys Gambit software. The absorber tube which we considered for our study is made up of Stainless Steel AISI 302 material. The meshed model so created was then exported to the Ansys Fluent 6.3 software and simulations were performed for different mass flow rates of the fluid. The fluid which we used in the computational analysis study is Therminol 55. The temperature differences for different mass flow rates of the liquid passing through the absorber tube were found out and based on the temperature rise contours plots so obtained, we have plotted the surface heat transfer coefficient for the absorber tube. We also found out the static temperature contour plot for the fluid flowing through the given absorber tube taking into account the heat flux acting on the absorber tube due to the hourly and daily average solar radiation.


Author(s):  
Brian Dincau ◽  
Arian Aghilinejad ◽  
Jong-Hoon Kim ◽  
Xiaolin Chen

Deterministic lateral displacement (DLD) is a common name given to a class of continuous microfluidic separation devices that use a repeating array of pillars to selectively displace particles having a mean diameter greater than the critical diameter (Dc). This Dc is an emergent property influenced by pillar shape, size, and spacing, in addition to the suspending fluid and target particle properties. The majority of previous research in DLD applications has focused on the utilization of laminar flow in low Reynolds number (Re) regimes. While laminar flow exhibits uniform streamlines and predictable separation characteristics, this low-Re regime is dependent on relatively low fluid velocities, and may not hold true at higher processing speeds. Through numerical modeling and experimentation, we investigated high-Re flow characteristics and potential separation enhancements resulting from vortex generation within a DLD array. We used an analytical model and computational software to simulate DLD performance spanning a Re range of 1–100 at flow rates of 2–170 μL/s (0.15–10 mL/min). Each simulated DLD array configuration was composed of 60 μm cylindrical pillars with a 45 μm gap size. The experimental DLD device was fabricated using conventional soft lithography, and injected with 20 μm particles at varying flow rates to observe particle trajectories. The simulated results predict a shift in Dc at Re > 50, while the experimental results indicate a breakdown of typical DLD operation at Re > 70.


Author(s):  
Muthuram A ◽  
Thanigaiarasu S ◽  
Rakesh Divvela ◽  
Rathakrishnan Ethirajan

AbstractEffect of nozzle geometries on the propagation of twin jet issuing from nozzles with circle-circle, circle-ellipse, circle-triangle, circle-square, circle-hexagon and circle-star geometrical combinations was investigated for Mach numbers 0.2, 0.4, 0.6 and 0.8. In all the cases, both jets in the twin jet had the same Mach number. All the twin jets of this study are free jets, discharged into stagnant ambient atmosphere. The result of the twin jets issuing from circle-circle nozzle is kept as the reference in this study. For all the twin jet nozzles, the inter nozzle spacing; the distance between the nozzle axes (S) was 20 mm and all the nozzles had an equivalent area of 78.5 mm2. Thus for all the cases of the present study, S/D ratio is 2. The results show that the mixing of the combined jet, after the merging point is strongly influenced by the combined effect of the nozzle geometry and jet Mach number. Among the six different twin jet nozzle configuration studied, circle-square combination is found to be the most superior mixing promoter.


2019 ◽  
Vol 141 (6) ◽  
Author(s):  
Xinhai Li ◽  
Yong Cheng ◽  
Xiaoyan Ma ◽  
Xue Yang

The inner-flow of gasoline direct injection (GDI) injector nozzles plays an important role in the process of spray, and affects the mixture process in gasoline engine cylinder. The nozzle structure also affects the inner-flow of GDI injector. In order to obtain uniform performance of GDI injector, the size consistency of injector nozzle should be ensured. This paper researches the effect of nozzle length and diameter on the inner flow and analyzes the sensitivity of inner flow characteristics to these structural parameters. First, this paper reveals the process of inception, development, and saturated condition of cavitation phenomenon in injector nozzle. Second, the inner-nozzle flow characteristics are more sensitive to small diameter than large diameter under the short nozzle length, while the sensitivity of the inner-nozzle flow characteristics to large nozzle diameter becomes strong as the increase of the nozzle length. Finally, the influence of nozzle angle on the injection mass flow is studied, and the single nozzle fuel mass will increase as the decrease of nozzle angle α. And the sensitivity of inner-flow characteristic to nozzle angle becomes strong as the decrease of α.


Author(s):  
Shashank R Chaurasia ◽  
RM Sarviya

An experimental analysis has been carried out to investigate the thermal and friction factor characteristics of fluid flow in a tube with double strip helical screw tape (DS-HST) inserts with different values of twist ratio and compared with single strip helical screw tape inserts and plain tube. Water is used as a working fluid at different flow rates with constant heat flux conditions. CFD analysis is also carried out to visualize thermal and fluid flow characteristics of fluid flow in tube with inserts. Experimental results have showed that Nusselt number and friction factor have attained excellent enhancement with double strip helical screw tape inserts in the range of flow rates than single strip helical screw tape inserts at the value of twist ratio 1.5. Correlation is also developed for Nusselt number with a range of Reynolds number, twist ratio and number of strips. Moreover, the performance ratio has attained maximum value at twist ratio of 2.5 with high values of flow rate. It is concluded that DS-HST is able to attain enhancement in the efficiency of heat exchanger, causing a reduction in size for thermal applications.


Sign in / Sign up