scholarly journals Facile preparation of 3D GO with caffeic acid for efficient adsorption of norfloxacin and ketoprofen

2020 ◽  
Vol 81 (7) ◽  
pp. 1461-1470
Author(s):  
Ying Lu ◽  
Youlin Li ◽  
Yi Gao ◽  
BoXuan Ai ◽  
Wei Gao ◽  
...  

Abstract In this paper, a simple and green method was developed to fabricate a three-dimensional (3D) graphene-based material with the assistance of caffeic acid (CA). The prepared 3D graphene displayed fast and high sorption for norfloxacin (NOR) and ketoprofen (KP). Their adsorption equilibrium was achieved within 12 h for NOR and KP, which was attributed to their fast diffusion in the porous structure of the 3D graphene. The maximum adsorbed amount of this adsorbent was 220.99 mg/g for NOR and 125.37 mg/g for KP according to the Langmuir model at pH 6.6, 298 K. In the competitive adsorption of six pharmaceuticals, the organic compounds in the form of cations are preferentially adsorbed on the adsorbent. The co-existing organic compounds in the actual wastewater do not seriously inhibit the adsorption of NOR and KP. This study provides the theoretical basis for the facile and low-cost preparation of high-performance 3D graphene adsorbents. The results of this study demonstrate the potential utility of 3D graphene as a very effective adsorbent for pharmaceuticals removal from contaminated water.

Author(s):  
Marcel Simsek ◽  
Nongnoot Wongkaew

AbstractNon-enzymatic electrochemical sensors possess superior stability and affordability in comparison to natural enzyme-based counterparts. A large variety of nanomaterials have been introduced as enzyme mimicking with appreciable sensitivity and detection limit for various analytes of which glucose and H2O2 have been mostly investigated. The nanomaterials made from noble metal, non-noble metal, and metal composites, as well as carbon and their derivatives in various architectures, have been extensively proposed over the past years. Three-dimensional (3D) transducers especially realized from the hybrids of carbon nanomaterials either with metal-based nanocatalysts or heteroatom dopants are favorable owing to low cost, good electrical conductivity, and stability. In this critical review, we evaluate the current strategies to create such nanomaterials to serve as non-enzymatic transducers. Laser writing has emerged as a powerful tool for the next generation of devices owing to their low cost and resultant remarkable performance that are highly attractive to non-enzymatic transducers. So far, only few works have been reported, but in the coming years, more and more research on this topic is foreseeable. Graphical abstract


2017 ◽  
Vol 5 (6) ◽  
pp. 2710-2716 ◽  
Author(s):  
Yanshan Huang ◽  
Ke Li ◽  
Jingjing Liu ◽  
Xing Zhong ◽  
Xiangfeng Duan ◽  
...  

A 3D graphene/polyimide composite is fabricated by a one-step solvothermal strategy as a high-performance cathode for both rechargeable lithium and sodium batteries.


2022 ◽  
Vol 6 (1) ◽  
Author(s):  
Taikyu Kim ◽  
Cheol Hee Choi ◽  
Pilgyu Byeon ◽  
Miso Lee ◽  
Aeran Song ◽  
...  

AbstractAchieving high-performance p-type semiconductors has been considered one of the most challenging tasks for three-dimensional vertically integrated nanoelectronics. Although many candidates have been presented to date, the facile and scalable realization of high-mobility p-channel field-effect transistors (FETs) is still elusive. Here, we report a high-performance p-channel tellurium (Te) FET fabricated through physical vapor deposition at room temperature. A growth route involving Te deposition by sputtering, oxidation and subsequent reduction to an elemental Te film through alumina encapsulation allows the resulting p-channel FET to exhibit a high field-effect mobility of 30.9 cm2 V−1 s−1 and an ION/OFF ratio of 5.8 × 105 with 4-inch wafer-scale integrity on a SiO2/Si substrate. Complementary metal-oxide semiconductor (CMOS) inverters using In-Ga-Zn-O and 4-nm-thick Te channels show a remarkably high gain of ~75.2 and great noise margins at small supply voltage of 3 V. We believe that this low-cost and high-performance Te layer can pave the way for future CMOS technology enabling monolithic three-dimensional integration.


Author(s):  
Jifeng Wang ◽  
Qubo Li ◽  
Norbert Mu¨ller

A mechanical and optimal analyses procedure is developed to assess the stresses and deformations of Novel Wound Composite Axial-Impeller under loading conditions particular to centrifuge. This procedure is based on an analytical method and Finite Element Analysis (FEA, commercial software ANSYS) results. A low-cost, light-weight, high-performance, composite turbomachinery impeller from differently designed patterns will be evaluated. Such impellers can economically enable refrigeration plants using water as a refrigerant (R718). To create different complex patterns of impellers, MATLAB is used for creating the geometry of impellers, and CAD software UG is used to build three-dimensional impeller models. Available loading conditions are: radial body force due to high speed rotation about the cylindrical axis and fluid forces on each blade. Two-dimensional plane stress and three-dimensional stress finite element analysis are carried out using ANSYS to validate these analytical mechanical equations. The von Mises stress is investigated, and maximum stress and Tsai-Wu failure criteria are applied for composite material failure, and they generally show good agreement.


Author(s):  
Jiawei Wu ◽  
Jing Chen ◽  
Xiaodong Wang ◽  
An'an Zhou ◽  
Zhenglong Yang

For the higher safety and energy density, solid-state electrolyte with better mechanical strength, thermal and electrochemical stability is a perfect choice. To improve the performance of PEO, usage of low-cost...


NANO ◽  
2020 ◽  
Vol 15 (05) ◽  
pp. 2050062
Author(s):  
Zhaolei Meng ◽  
Xiaojian He ◽  
Song Han ◽  
Zijian Hu

Carbon materials are generally employed as supercapacitor electrodes due to their low- cost, high-chemical stability and environmental friendliness. However, the design of carbon structures with large surface area and controllable porous structure remains a daunt challenge. In this work, a three-dimensional (3D) hybrid aerogel with different contents of MoS2 nanosheets in 3D graphene aerogel (MoS2-GA) was synthesized through a facial hydrothermal process. The influences of MoS2 content on microstructure and subsequently on electrochemical properties of MoS2-GA are systematically investigated and an optimized mass ratio with MoS2: GA of 1:2 is chosen to achieve high mechanical robustness and outstanding electrochemical performance in the hybrid structure. Due to the large specific surface area, porous structure and continuous charge transfer network, such MoS2-GA electrodes exhibit high specific capacitance, good rate capability and excellent cyclic stability, showing great potential in large-scale and low-cost fabrication of high-performance supercapacitors.


2020 ◽  
Vol 7 (3) ◽  
pp. 191949 ◽  
Author(s):  
Amy Courtney ◽  
Luke M. Alvey ◽  
George O. T. Merces ◽  
Niamh Burke ◽  
Mark Pickering

With technologies rapidly evolving, many research institutions are now opting to invest in costly, high-quality, specialized microscopes which are shared by many researchers. As a consequence, the user may not have the ability to adapt a microscope to their specific needs and limitations in experimental design are introduced. A flexible work-horse microscopy system is a valuable tool in any laboratory to meet the diverse needs of a research team and promote innovation in experimental design. We have developed the Flexiscope; a multi-functional, adaptable, efficient and high-performance microscopy/electrophysiology system for everyday applications in a neurobiology laboratory. The core optical components are relatively constant in the three configurations described here: an upright configuration, an inverted configuration and an upright/electrophysiology configuration. We have provided a comprehensive description of the Flexiscope. We show that this method is capable of oblique infrared illumination imaging, multi-channel fluorescent imaging and automated three-dimensional scanning of larger specimens. Image quality is conserved across the three configurations of the microscope, and conversion between configurations is possible quickly and easily, while the motion control system can be repurposed to allow sub-micrometre computer-controlled micromanipulation. The Flexiscope provides similar performance and usability to commercially available systems. However, as it can be easily reconfigured for multiple roles, it can remove the need to purchase multiple microscopes, giving significant cost savings. The modular reconfigurable nature allows the user to customize the system to their specific needs and adapt/upgrade the system as challenges arise, without requiring specialized technical skills.


RSC Advances ◽  
2016 ◽  
Vol 6 (109) ◽  
pp. 107768-107775 ◽  
Author(s):  
Yew Von Lim ◽  
Zhi Xiang Huang ◽  
Ye Wang ◽  
Fei Hu Du ◽  
Jun Zhang ◽  
...  

Tungsten disulfide nanoflakes grown on plasma activated three dimensional graphene networks. The work features a simple growth of TMDs-based LIBs anode materials that has excellent rate capability, high specific capacity and long cycling stability.


2012 ◽  
Vol 2 (1) ◽  
Author(s):  
Jifeng Wang ◽  
Jorge Olortegui-Yume ◽  
Norbert Müller

AbstractA low cost, light weight, high performance composite material turbomachinery impeller with a uniquely designed blade patterns is analyzed. Such impellers can economically enable refrigeration plants to use water as a refrigerant (R718). A strength and dynamic characteristics analyses procedure is developed to assess the maximum stresses and natural frequencies of these wound composite axial impellers under operating loading conditions. Numerical simulation using FEM for two-dimensional and three-dimensional impellers was investigated. A commercially available software ANSYS is used for the finite element calculations. Analysis is done for different blade geometries and then suggestions are made for optimum design parameters. In order to avoid operating at resonance, which can make impellers suffer a significant reduction in the design life, the designer must calculate the natural frequency and modal shape of the impeller to analyze the dynamic characteristics. The results show that using composite Kevlar fiber/epoxy matrix enables the impeller to run at high tip speed and withstand the stresses, no critical speed will be matched during start-up and shut-down, and that mass imbalances of the impeller shall not pose a critical problem.


Sign in / Sign up

Export Citation Format

Share Document