Trends in the development of fire alarm system controllers for fire alarm systems

2021 ◽  
Vol 30 (5) ◽  
pp. 76-83
Author(s):  
A. N. Chlenov ◽  
T. A. Butcinskaya

Introduction. Fire alarm system controllers are the main technical aids that serve as the backbone of a fire alarm system (a unit) at a facility. They consolidate fire alarm messages, coming from fire detectors, analyze, process, and deliver them to the user and display them in the pre-set format. The technical capacity of fire alarm system controllers is constantly improving in line with the technical progress and tightening fire safety requirements.Aims and purposes. The purpose of the article is to analyze the state of and trends in the development of fire alarm system controllers, that improve the fire safety of protected facilities. The task encompasses the retrospective review of principal tactical and technical characteristics of fire alarm devices for the period starting from the early 1950s to the present time in Russia, as well as the statistical analysis of the pace of their supply on the market of automatic fire fighting systems.Methods. Methods of system analysis and mathematical statistics were used.Results and discussion. The main stages of development of instruments for fire alarm systems that are reflective of the technical progress, primarily in the field of radio electronics, as well as the socio-economic transformations in Russia are specified. The article presents the results of statistical studies, carried out by the co-authors at different times and characterizing a change in the Russian market based on the comparative data on domestic and foreign alarm systems. The main trends in the development of the product mix and technical specifications of devices during the analyzed period are identified. The co-authors focus on the generalized layout of a blockmodular apparatus of a fire alarm system controller and determine the requirements for communication between functional modules to ensure the reliable operation of a fire alarm system.Conclusions. The main trends in the development of fire alarm system controllers, designated for fire alarm systems, focus on the application of new communication technologies and microelectronic devices that solve comprehensive safety problems with regard for the top-priority requirements of fire safety. The pace of improvement of tactical technological characteristics of devices is reflective of the state of and trends in the development of automatic fire fighting systems in Russia.

2012 ◽  
Vol 241-244 ◽  
pp. 2606-2610
Author(s):  
Zhong Jiang ◽  
Jin Jiang

At present, the automatic fire alarm systems on sale were produced by different factories, which resulted in the information not being shared mutually. Furthermore, it was difficult to connect the different fire auto-alarm systems to the same network. They couldn't communicate automatically with the city fire-fight commanding center in time. We designed interface module of automatic fire alarm controller network and interface module of data center network. By using the existing net of PSTN and internet, it could transmit the breakdown information and a fire information of the automatic fire alarm systems to the fire-fight commanding center, the long-range diagnose, the real-time monitor of a fire and the long-range control in the city fire auto-alarm system was realized.


2020 ◽  
Vol 69 (3) ◽  
pp. 77-87
Author(s):  
Krzysztof Jakubowski

A fire alarm system (FAS) is one of the most important safety facilities used in any building, and include CCTV and intrusion and panic alarms. Pursuant to the Polish Regulation of the Minister of the Interior and Administration of 07/06/2010, FASs are required in specific civil structures. FASs are directly responsible for the protection of the life and health of humans and animals, and indi-rectly for property at the protected sites. In considering the fire hazards and scenarios, a FAS should be characterized with sufficient reliability. Every FAS is subject to specific requirements in terms of reliability and continuity of performance at the stages of monitoring, FAS failure, and fire. This work is an analysis of the reliability requirements for FAS. Keywords: fire alarm system, reliability requirements, structures.


2020 ◽  
pp. 6-13
Author(s):  
Терлецький Т. В. ◽  
Кайдик О. Л. ◽  
Євсюк М. М. ◽  
Ткачук А. А. ◽  
Сомов Д. О.

The fire alarm system shall detect the initial signs of fire at an early stage of its occurrence and shall not give false positives. It also depends on balancing the fire alarm loop with the fire receiving control device. The use of devices from different manufacturers in the construction of a fire alarm may result in the malfunctioning of such a system and giving false signals.The article presents the results of the analysis of the state of non-address fire control receivers of different manufacturers, depending on the mode of the fire alarm loop, in which he may be. The received generalized nomogram of states of non-address control devices depending on the resistance of the fire plume is presented. A method for determining the resistance of loop elements against different fire detectors is proposed and an appropriate algorithm is developed.


2021 ◽  
Vol 91 ◽  
pp. 107-120
Author(s):  
A. N. Chlenov ◽  
◽  
A. V. Kochegarov ◽  
T. A. Butcinskaya ◽  
A. M. Aleshkov ◽  
...  

Introduction. The fire safety of the protected object is determined by the possibility of reliable fire detection. Insufficiently effective operation of the fire alarm system can lead to the death of people, unacceptable material and other damage. The video surveillance system, being one of the main links of the engineering security system, monitors emergency situations in real time and, in particular, a breakout of fire at the protected object. Goals and objectives. The purpose of the article is to analyze the state and trends in the development of video surveillance equipment aimed at improving the fire safety of protected objects. Tasks include regulatory justification of the use of video surveillance in fire alarm systems, review of methods of fire detection by video surveillance and improving their effectiveness under the influence of interfering factors, as well as evaluation of the effectiveness of video surveillance in fire protection systems. Methods. The methods of the system analysis and probability theory are used. Results and discussion. The requirements of regulatory documents for detectors with a video detection channel for their effective operation in fire alarm systems are considered. The main directions of development of means and methods of application of video surveillance in fire protection systems are defined. It is shown that reducing the risk of non-detection of fire to an acceptable level can be achieved by increasing the probability of effective operation of the fire alarm system, as well as by increasing the positive impact of the video surveillance system, which is a part of the complex security system of the object. Conclusions. Video surveillance significantly increases the efficiency of fire detection. It allows you to get a visual picture of the state of the protected object, which has such a high information content that no other security means can provide. The use of video surveillance equipment in fire alarm systems, as well as their integration with industrial and fire automation systems is one of the main reserves for increasing the fire safety of facilities. Keywords: video surveillance, fire detector with video detection channel, fire alarm, video analytics, fire protection


Author(s):  
Jacek Paś ◽  
Tomasz Klimczak ◽  
Adam Rosiński ◽  
Marek Stawowy

AbstractA fire alarm system (FAS) is a system comprising signalling-alarm devices, which automatically detect and transmit information about fire, but also receivers of fire alarms and receivers for damage signals. Fire alarm systems function in different environmental conditions. During operation they should be in state of fitness. This is determined by the reliability of the assembled units and rational management of the operation process. Therefore a reliability and operational analysis of fire alarm systems as a whole is essential. This article presents an authorial model and an operational and reliability analysis of FAS, which is exploited in a transport building. It also demonstrates relationships occurring in the analysed system, where to an addressable fire alarm central unit with detection loops and control-monitoring loops alarm device lines (with monitored relay outputs for actuation of alarm-signalling devices) were connected. Research and analysis of results for representative FAS, which were exploited in similar environmental conditions, were conducted in order to determine operational and reliability parameters of the investigated system. FAS computer simulation was run during the time t = 1 year of safety system operation. This led to the calculation of the probability value of the analysed FAS staying in the examined operational states.


Author(s):  
Dr. Aziz Makandar

Abstract: The design of a fire alarm with Arduino-based system by means of GSM Module. The work purposely for house safety where the main point is to avoid the fire accidents occurred to the residents and the properties inside the house. In order to prevent losses accrued from fire accidents, various alarm systems have been developed such as smoke detectors, temperature sensor based systems etc. The design and implementation of a cost effective and reliable GSM based SMS Alert fire alarm system. The device will be able to monitor the temperature of the environment, the smoke level, send SMS alert to an inbuilt GSM number. When the system detects the temperature of 100C or more, it will immediately display an alert notification on LCD display and simultaneously sending an SMS alert to the users upon the high raise temperature in the house. This fire detection system consists of a smoke sensor, buzzer, LCD display and GSM module is interfaced with Arduino board. Keywords: Smoke sensor, GSM Module, Arduino, LED display, Buzzer


2020 ◽  
Vol 29 (3) ◽  
pp. 95-102
Author(s):  
A. N. Chlenov ◽  
T. A. Butcinskaya

Introduction. Rationale of the topic of this article is the need to improve the effectiveness of fire detection. One of the modern solutions to this problem is the use of video technology. The article is aimed at developing a method to assess the effectiveness of video surveillance in the fire protection system on the basis of the formed mathematical model.Methods of research. The fire risks theory is used for formation of mathematical model. The potential fire detection risk is introduced as a quantitative measure of the possibility of undetected fire occurrence at the protected facility, development and implementation of its consequences for people and material valuables. It is calculated as the product of the maximum probability of fire by the probability of its non-detection by the technical means and alarm systems used. The efficiency of video surveillance use in the fire protection system is determined on the basis of compliance of the complex risk index of fire non-detection with the permissible value.Research results. The possibilities of increasing the efficiency of fire detection through the use of video technology are considered. Reducing the fire detection risk can be achieved by using video channel fire detectors that reduce the time it takes to reliably detect a fire. The probability of reliable detection is an important parameter of the detector during its operation in the fire alarm system and characterizes the degree of performance of its main function. The main ways to improve the efficiency of fire detection are the improvement of fire detectors with video channel, the joint use of fire video detectors and other detection devices, such as automatic multi-criteria detectors, thermal imaging сamera, as well as the use of photo and video in centralized surveillance systems.Conclusions. The offered method of estimation of efficiency of application of video surveillance in fire protection systems can be used for a substantiation of parameters of technical means (systems) of the fire alarm system and passive fire-fighting measures established on the facility.


2013 ◽  
Vol 694-697 ◽  
pp. 1286-1290
Author(s):  
Xiao Lei Chen

This paper describes the structure and the modules of the automatic fire alarm system. On this basis, it gave an effective and reasonable way to divide the fire and fire-fighting equipment for automatic fire alarm system controller linkage control module. Still it designed the linkage relationship, the linkage input and database storage linkage output to realize this linkage control module.


2012 ◽  
Vol 433-440 ◽  
pp. 6917-6920 ◽  
Author(s):  
Quan Min Li ◽  
Chang Ying Xu ◽  
Hong Li Lv ◽  
Jun He

According the radial flutter extension structure problems in commonly used fire alarm system, a novel topology structure of fire alarm systems based-on holographic crystal forms was proposed. It was composed of multiple devices, including intelligent fire detectors, which can communicate with each other, record fire information and judge, alarms, security, evacuation lights etc. Each device can record all of the information so as to form the hologram. These devices on each floor level in buildings and decorated with vertical layout in the staircase, so that fire alarm system topology based-on holographic crystal forms was set up. The systems can ensure the normal operation of other devices in case that central control equipment failed in extreme cases. And then the automatic fire safety equipment continued to automatically control fire rescue and guide the staff in the correct escape route. Moreover, when a device or a line goes wrong, only failure equipment or system was cut off line, and others were still able to keep communications. Compared with other methods, this new system does not affect the normal equipment of the work.


Author(s):  
A.A. Poroshin ◽  
◽  
A.A. Kondashov ◽  
V.I. Sibirko ◽  
◽  
...  

The issues of ensuring fire safety of industrial enterprises using automatic fire alarm systems is discussed in the article. The foreign and Russian experience of conducting assessment of the efficiency of automatic fire alarm systems is analyzed. Despite the improvement of the regulatory framework for automatic fire alarm systems, the creation of new devices and technologies for detecting fire hazards, the problem of improving the reliability of automatic fire alarm systems actuation remains relevant. Using the statistical data of the federal state information system «Federal data bank «Fires», the calculations were made of the efficiency of automatic fire alarm system actuation at the industrial facilities from 2016 to 2020. Various types of industrial objects are considered: industrial buildings; warehouse buildings (structures); buildings, industrial installations. Calculations of the efficiency of automatic fire alarm systems are based on determining the number of cases of implementation of various modes of its operation. The social and material consequences of fires are investigated considering actuation of the automatic fire alarm systems. When calculating the efficiency of automatic fire alarm systems, the belonging of production facilities to a certain type of property, risk category and branch of industry is considered. Studies showed that the highest efficiency is characteristic of production facilities that are in the federal ownership (90.9 %) and grows up with an increase in the risk category of the object of protection. Thus, for industrial facilities assigned to the category of high risk, the efficiency of automatic fire alarm system actuation for the period from 2016 to 2020 is 92.3 %. By the type of industry, the lowest efficiency of automatic fire alarm system actuation is observed at the fuel industry (62 %), as well as at the construction and shipbuilding enterprises (75 %).