scholarly journals RAINWATER HARVESTING QUALITY ASSESSMENT AND EVALUATION: IIUM CASE STUDY

2020 ◽  
Vol 21 (1) ◽  
pp. 12-22
Author(s):  
Nassereldeen Ahmed Kabashi Abuelfutouh ◽  
Mohamed Jamie ◽  
Abdurahman Nour ◽  
Noor Illi Fuad

This study focuses on rainwater harvesting quality at the Faculty of Engineering, International Islamic University Malaysia (IIUM). As development is progressing over the years in Malaysia, there is also an increasing number of environmental issues and those issues are getting worse day by day. At present, Malaysia is blessed with plentiful annual rainfall that represents approximately 314 mm of monthly rainfall but there is no evidence that this rainwater is redirected for daily usage. To pursue a more sustainable development, rainwater harvesting has been recognized as one innovative solution. The IIUM Gombak campus is located in a hillside area that is a suitable study area to perform rainwater harvesting, which can be used as an alternative water supply in the future and reduce utility bills for water used on the campus. Firstly, a suitable study area for rain water harvesting around KOE, IIUM was determined before collection of data to determine the storage capacity needed. This study includes the estimation of rainwater quantity that can be harvested in one year. The quality of rainwater in terms of biochemical oxygen demand (BOD), chemical oxygen demand (COD), pH, total suspended solid (TSS), turbidity, and microbial count were studied. Data analysis showed that the values of BOD, COD, pH, TSS, turbidity, and microbial count were in the range of 2 - 3.2 mg/l, 22.5 – 42.5 mg/l, 5.9 - 6.5, 20 mg/l, 9 -11 NTU, and between 200 -260 cfu/ml, respectively. This indicates that the harvested rainwater is acceptably clean but not suitable to be used as drinking water. ABSTRAK: Fokus kajian ini adalah pada kualiti air hujan yang ditadah di Fakulti Kejuruteraan, Universiti Islam Antarabangsa Malaysia (UIAM). Sejajar dengan pembangunan pesat di Malaysia, isu alam sekitar juga semakin bertambah dan menjadi semakin teruk hari ke hari. Pada masa sama, ketika ini Malaysia dirahmati dengan hujan yang mencurah setiap tahun, dengan kuantiti bulanan sebanyak 314 mm air hujan dan tidak ada bukti penggunaan air hujan ini bagi kegunaan harian dsb. Bagi memenuhi keperluan kelangsungan pembangunan, penadahan air hujan dikenal pasti sebagai satu penyelesaian inovatif. Kampus UIAM Gombak terletak di kawasan pinggiran bukit yang sesuai bagi menjalankan kajian tadahan air hujan. Ianya boleh digunakan sebagai bekalan air alternatif pada masa depan dan mengurangkan bil utiliti bekalan air dalam kampus. Terlebih dahulu, kawasan kajian yang sesuai dikenal pasti berdekatan Fakulti Kejuruteraan, UIAM bagi mengumpul air hujan sebelum data dikumpulkan bagi mengenal pasti kapasiti pengumpulan yang diperlukan. Kajian ini juga menganggar kuantiti air hujan yang boleh ditadah dalam satu tahun. Kualiti air hujan dikaji dari segi keperluan oksigen biokimia (BOD), keperluan oksigen kimia (COD), pH, jumlah pepejal terampai (TSS), kekeruhan dan bilangan mikrob. Analisis data mendapati nilai BOD, COD, pH, TSS, kekeruhan dan bilangan mikrob berada dalam julat 2 - 3.2 mg/l, 22.5 – 42.5 mg/l, 5.9 - 6.5, 20 mg/l, 9 -11 NTU dan antara 200 -260 cfu/ml, masing-masing. Ini menunjukkan air hujan yang ditadah adalah boleh diterima sebagai bersih tetapi tidak sesuai dijadikan sebagai air minuman

2017 ◽  
Vol 14 (3) ◽  
pp. 253
Author(s):  
Siswanta Kaban ◽  
Husnah Husnah ◽  
Siti Nurul Aida

Penelitian ini dilakukan untuk mengetahui kualitas air Sungai Musi tahun 2007 sampai dengan 2008 di bagian tengah dan hilir berdasarkan pada sumber polutan. Empat belas stasiun pengambilan contoh ditetapkan sebagai sumber polutan seperti industri maupun pemukiman penduduk, dan referensi yang jauh dari industri maupun pemukiman yang digunakan sebagai pembanding. Pada setiap stasiun, pengambilan contoh dilakukan 3 kali waktu pengambilan, yaitu bulan April, Juni, dan Januari yang dapat mewakili 3 musim yang berbeda pada tahun tersebut. Beberapa parameter diukur in situ sementara beberapa lain dianalisis di laboratorium dengan standar methods (AWWAWEF, 2005). Dari hasil penelitian didapatkan bahwa industri yang bergerak di bidang pengolahan kelapa sawit dan karet cenderung menurunkan kualitas perairan di Sungai Musi. Kandungan logam berat dalam sedimen di Sungai Musi relatif rendah dengan kandungan Cr+6 dan Pb yang tertinggi masing-masing 13,481 dan 1,747 μg per g. Curah hujan cenderung menurunkan beberapa parameter fisika dan kimia kualitas perairan. Potensi pencemaran cenderung ditemukan di bagian hilir Sungai Musi, karena sebaran industri dan intensitas pemanfaatan perairan cukup tinggi di bagian sungai tersebut. Study in order to know distribution of pollution source and its effect on water quality of the middle and down stream of Musi River was conducted in April and June 2007 and January 2008. Fourteen sampling sites were selected based on the pollution source and the minimal degradation site (reference sites). Parameters observed were pollution source distribution and water and sediment parameters such as physical and chemical parameters. Water sample was collected at 0.5 m from water surface by using Kemmerer water sampler while sediment samples were taken by using Ekman grab. Some of the parameters were analyzed in situ while the rest were analyzed in laboratory. Results indicated that oil palm and rubber industries were mostly the pollution source in Musi River. Potential pollution source was mostly found in the middle and down stream of Musi River since most of pollution source and high water utilization found in this area. Water quality parameters except total suspended solid and biochemical oxygen demand, were still in the range that can be tolerated by the aquatic organisms. Rain fall tends to decrease water quality of the river. Concentration of heavy metal such as Chrom (Cr+6) and plumbum in the sediment were in still in low concentration with the highest concentration reaching 13.481 and 1.747 μg per g respectively.


2021 ◽  
Vol 2 (1) ◽  
pp. 62-67
Author(s):  
Martino Elvis Presley Sukiman ◽  
Maxi Tendean ◽  
Sri Sulastriningsih

The problem in this study is the existence of community activities that dispose of household waste and toilet waste directly into the Poopoh River. This study aims to analyze and obtain river water quality data. This type of research is a quantitative research using a fixed sample water sampling method. The parameters measured were pH, DO (Dissolved Oxygen), BOD (Biological Oxygen Demand), and TSS (Total Suspended Solid). The results showed that there had been a decrease in the quality of river water in the downstream part of the river as seen from the results of laboratory tests which stated that the pH level in the upstream part of the river reached 6.94 and downstream increased to 7.98. The level of BOD in the upper reaches of the river is 1.8 and in the lower reaches of the river rises to 26.95. The DO level in the upstream part of the river is 7.5 and at the downstream level, it drops to 1.62. The TSS level in the upper reaches of the river is 5 and in the lower reaches of the river, it has increased to 20. It can be seen that there has been a decrease in the quality of river water from upstream to downstream, especially in the parameters of BOD and DO.


2016 ◽  
Vol 15 (4) ◽  
pp. 49-53
Author(s):  
Sumona S Das ◽  
D Sayantan

Pure water is essential for human survival. The availability of good quality water is an indispensable feature for preventing diseases and improving the quality of life. So, it is necessary to know about the different physicochemical parameters of water such as, temperature, electrical conductivity (EC), total suspended solid (TSS), total dissolved substance (TDS),turbidity, pH, alkalinity, hardness, chloride, sulphate, nitrate, fluoride, dissolved oxygen (DO), chemical oxygen demand (COD), biochemical oxygen demand (BOD), nitrate and phosphate. Also Biological parameters such as planktons were examined. Results of the study indicated that the pond water of Bihar is slightly contaminated.


2021 ◽  
Vol 4 (4) ◽  
pp. 116-125
Author(s):  
MUDASSIR HASSAN ◽  
A. Hussaini ◽  
A. Musa ◽  
M. Muhammad

Water is one of the most important natural resources which play an essential role in human life. Most of the Nigerian institutions stored water in either plastic or overhead tanks for different purposes. However, there has been a growing concern over the safety of the stored water for human consumption following reported cases of microbial occurrence in water stored in tanks. This study aimed at investigating the water quality stored in plastic tanks in Umaru Musa Yar’adua University Katsina. Water samples were collected from plastic tanks and analyzed for some physico-chemical and heavy metals parameters. The result of physico-chemical parameters obtained shows that only dissolved oxygen, biological oxygen demand and chemical oxygen demand were observed above the maximum permissible limit for drinking recommended by WHO and NSDWQ with the mean value of 55.18 mg/l, 38.86 mg/l and 38.08 mg/l respectively. While the remaining parameters such as pH, electrical conductivity, total dissolved solids, turbidity, total suspended solid, alkalinity, sulphate, nitrate, phosphate, chloride and total hardness were found within the acceptable limit. However, analyzed result of heavy metals parameters revealed that all parameters were observed within desirable limit by WHO and NSDWQ for drinking water and suggested that the quality of water stored in plastic tanks was very good. It is concluded that, the quality of water stored in plastic tanks is suitable for human consumption. It is therefore recommended that, continuous monitoring of the water should be maintain so as to ascertain the safety of the water


2020 ◽  
Vol 15 (3) ◽  
pp. 70-77
Author(s):  
J.D Bala ◽  
F. A Kuta ◽  
N.U Adabara ◽  
O.P Abioye ◽  
H.S Auta ◽  
...  

Water used for washing carcasses of slaughtered animals and slaughter house is referred to as abattoir wastewater. This study was designed to investigate the microorganisms associated with abattoir wastewater and to establish the biodegradation potential of abattoir wastewater microbiota. Isolation of the microbes was carried out using pour plate technique. The total viable count for the microbes’ ranges from 2.5×104 - 4.6×105 cfu/mL. Results revealed that all the physicochemical parameters exceeded the permissible limits (total dissolved solid (TDS) 1748mg/L, total suspended solid (TSS) 176mg/L, biochemical oxygen demand (BOD5) 91 mg/L and chemical oxygen demand (COD) 227 mg/L). Microorganisms isolated include Staphylococcus aureus, Pseudomonas aeruginosa, Bacillus subtilis, Bacillus anthracis, Aspergillus niger, A. flavus, Mucor sp, Trichophyton quickeanum and Penicillium sp. Some of the microbes were observed to have biodegradation potential by their ability to grow on mineral salt media (MSM) incorporated with starch, cellulose, crude oil, kerosene and diesel as the sole source of carbon and energy. This study suggests that abattoir wastewater harbors microorganisms that could be hazardous to public health when discharged into the environment untreated hence the need for strict monitoring. These microbes isolated could be employed as agent of bioremediation of wastewaters. Key words: Abattoir; Biodegredation; Isolation; Microbiota; Wastewater


Jurnal Ecolab ◽  
2021 ◽  
Vol 15 (2) ◽  
pp. 101-109
Author(s):  
Dewi Ratnaningsih ◽  
◽  
Retno Puji Lestari ◽  
Ernawita Nazir

Kualitas air di suatu wilayah yang merupakan salah satu indikator lingkungan dapat dievaluasi menggunakan parameter fisika, kimia, dan biologi. Indeks Kualitas Air Indonesia (IKA-INA) dapat digunakan untuk menilai kondisi kualitas air secara menyeluruh pada lokasi dan waktu tertentu. IKA-INA dihitung dengan menggunakan sepuluh (10) parameter yaitu pH, Total Dissolved Solid (TDS), Total Suspended Solid (TSS), Dissolved Oxygen (DO), Biological Oxygen Demand (BOD), Chemical Oxygen Demand (COD), NO3, NH3, Total Phosphate (TP) dan fecal coliform. IKA-INA tersebut merupakan indeks kualitas air yang dapat memberikan informasi secara sederhana. Dalam pemanfaatannya, tidak semua data parameter dalam IKA-INA tersebut dapat terpenuhi karena adanya data tidak valid atau data yang hilang. Kajian ini bertujuan untuk memberi alternatif rumusan IKA-INA dengan parameter yang tidak lengkap atau jika tidak semua data dalam parameters tersebut tersedia. Metode yang digunakan dalam menyusun rumusan adalah dengan melakukan koreksi faktor bobot parameter IKA-INA terhadap parameter yang hilang dan nilai Q (nilai sub-indeks). Setelah itu dilakukan uji coba pada nilai baku mutu air dalam Peraturan Pemerintah No. 22/2021 Lampiran VI serta pada data kualitas air sungai yang mewakili kualitas baik dan buruk. Hasil uji coba menunjukkan bahwa bobot parameter terkoreksi dapat digunakan untuk penanganan parameter yang hilang dalam penilaian kualitas air dengan metode IKA-INA. Hasil IKA-INA dengan parameter hilang yang menggunakan bobot terkoreksi dan hasil IKA-INA dengan parameter lengkap mayoritas memberikan status IKA yang tidak berbeda, kecuali untuk parameter fecal coli dan parameter yang mempunyai kadar jauh berbeda terhadap kondisi air secara keseluruhan.


2018 ◽  
Vol 67 ◽  
pp. 04006 ◽  
Author(s):  
Irfan Aditya ◽  
Sutrasno Kartohardjono

Wastewater generated from the tofu industry usually still contains high organic pollutants that can contaminate the surface water. Therefore, it should be treated properly before it can be disposed to the environment. This study aims to evaluate the combination of coagulationflocculation and ultrafiltration methods in treating the wastewater from tofu industry. Based on the preliminary tests, the wastewater from tofu industry have pH, total dissolved solid (TDS), total suspended solid (TSS), turbidity and chemical oxygen demand (COD) of 3.4, 870 - 1080 mg/L, 370 mg/L, 446 FAU and 7954 mg/L, respectively. The coagulant and membrane used in this study were Poly aluminum chloride (PAC) and the ceramic membrane, respectively. Experimental results showed that the best pH for coagulation-flocculation process is at pH of 7.0, and this pH was then used for ultrafiltration process. The flux of the ultrafiltration membrane increased with increasing the trans membrane pressure due to increasing driving force. The observed parameters such as TSS and turbidity of wastewater decreased drastically after experiencing ultrafiltration process and met the National Environmental Quality Standard. However, the COD of water produced in the ultrafiltration process was still high and did not meet the National Environmental Quality Standard.


2020 ◽  
Vol 32 (4) ◽  
pp. 827-834
Author(s):  
Muhammad Towhid Moula ◽  
Ranjit K. Nath ◽  
Mh. Mosfeka Chowdhury ◽  
Md. Abu Bakar Siddique

Halda is an important river of Bangladesh, is now polluted in different ways through industrial, agricultural, domestic and sewage disposal. Increased anthropogenic activities have increased the potential pollution of the river and excessive pollutants may be toxic to humans and aquatic fauna. Presence of heavy metals in the river water causes perilous impact on the aquatic organisms. Hence, regular monitoring of pollution levels in the river is indispensable. In this study, we discuss about physico-chemical assessments of water quality parameters viz. pH, dissolve oxygen (DO), biochemical oxygen demand (BOD), chemical oxygen demand (COD), total solid (TS), total suspended solid (TSS), total dissolved substance (TDS), total alkalinity, turbidity, salinity, electrical conductivity (EC), hardness, chloride and heavy metals in the water of Halda river during rainy and winter seasons, at different points; sources of pollutants in water and their effects given starting from the early research until the current research.


2012 ◽  
Vol 610-613 ◽  
pp. 363-367
Author(s):  
Tipakorn Suwannarat ◽  
Nipon Pisutpaisal ◽  
Siriorn Boonyawanich

The purpose of current study was to examine the ability of electrocoagulation in decreasing chemical oxygen demand (COD) and total suspended solid (TSS) constituted in palm oil mill effluent. Bench-scale batch reactor containing two aluminum or steel plates (10 cm width × 30 cm height with 0.1 cm thickness) serving as electrodes with the interval distance of 3 cm was set up. The wastewater with COD concentration of 68,425 mg L-1 was treated in the reactor under the varied direct currents (0.3-1.3 A) and contact time (30-120 min). Sodium chloride was added to the wastewater to obtain the final concentration of 2 g L-1 (conductivity of 10 ms) prior to being fed into the reactor. The results showed that higher treatment efficiency when the aluminum was used as electrodes compared to the steel. COD removal efficiency was directly proportional to the contact time. The maximum COD and TSS removal observed at 1.3 A current input and 60 min contact time are 74.1 and 77.0%, respectively.


Sign in / Sign up

Export Citation Format

Share Document