scholarly journals Is There a Significant Difference in Accuracy of Four Intraoral Scanners for Short-Span Fixed Dental Prosthesis? A Comparative In Vitro Study

2021 ◽  
Vol 11 (18) ◽  
pp. 8280
Author(s):  
Anca Jivănescu ◽  
Adrian Bara ◽  
Andrei-Bogdan Faur ◽  
Raul Nicolae Rotar

Is the accuracy of the older generation of IOSs an impediment for obtaining a quality intraoral digital impression? The aim of this study was to evaluate the differences in accuracy between four intraoral scanners (two of the latest IOSs and two older IOSs) in the scenario of a short span fixed partial denture, and to determine if these differences have a major impact on the quality of the final digital impression. Four intraoral scanners: Cerec PrimeScan, Medit i700, Cerec Omnicam and Planmeca PlanScan and one laboratory scanner were used in this study. The scanned data were processed with the help of Geomagic Control X, a metrology software. For the statistical data analysis, the level of significance was set as 0.05 (α = 0.05). The Medit i700 group displayed the best level of trueness with the median value of 23.25 µm, PrimeScan group with a median of 25.55 µm, Omnicam group with a median of 32.3 µm and the PlanScan group which displayed the lowest level of trueness with a median value of 75.8 µm. From the precision data analysis, it was concluded that the PrimeScan group showed the best results, followed by Medit i700, Omnicam and the PlanScan group which showed the lowest precision. Even if there are some significant differences in accuracy between old and new IOSs, in the in vitro scenario of short span dental prostheses, the accuracy values were within the clinically acceptable range and may present important clinical implications.

2012 ◽  
Vol 2012 ◽  
pp. 1-5 ◽  
Author(s):  
Blerim Kamberi ◽  
Donika Bajrami ◽  
Miranda Stavileci ◽  
Shuhreta Omeragiq ◽  
Fatmir Dragidella ◽  
...  

Aim. The purpose of this in vitro study was to assess the antimicrobial efficacy of Biopure MTAD against E. faecalis in contaminated root canals. Materials and Methods. Forty-two single rooted extracted human teeth were inoculated with E. faecalis and incubated for four weeks. The samples were divided in two control and five experimental groups irrigated with 1.5% sodium hypochlorite solution (NaOCl); 3% NaOCl; BioPure MTAD; 1.5% NaOCl/17% EDTA; or 3% NaOCl/17% EDTA. After a one-week incubation, complete disinfection was confirmed by the absence of turbidity in the incubation media. Dentin shavings were taken from samples with no turbidity to verify whether E. faecalis was present in dentin tubules. Results were analyzed statistically using Fisher's exact test, with the level of significance set at . Results. Statistical analysis of the data obtained at Day 7 and after dentin shaving analysis showed that BioPure MTAD had significantly greater antibacterial activity than 1.5% NaOCl, 1.5% NaOCl/17% EDTA and 3% NaOCl/17% EDTA. No significant difference was detected between MTAD and 3% NaOCl. Conclusions. These findings suggest that BioPure MTAD possesses superior bactericidal activity compared with NaOCl and EDTA against E. faecalis.


2019 ◽  
Vol 19 (1) ◽  
Author(s):  
Francesca Cattoni ◽  
Giulia Teté ◽  
Alessandro Mauro Calloni ◽  
Fabio Manazza ◽  
Giorgio Gastaldi ◽  
...  

Abstract Background Aesthetic porcelain veneers proved to be a long-term reliable prosthetic solution, ensuring minimal invasiveness. The use of veneers requires an adhesive cementation technique, so maintaining as much enamel as possible is to ensure lasting success. A diagnostic mock-up is a key tool that allows a preview of the outcome of the aesthetic restoration: it is obtainable both in an analog and digital way. With the recent developments in impression technology and the ever so fast growing use of CAD-CAM technologies it is useful to understand the pros and cons of either one of these techniques (analog and digital) in order to identify the easier and more convenient workflow in aesthetic dentistry. Methods After taking pictures and impressions of the dental arcs of a patient in need of aesthetic rehabilitation, 52 resin models were produced and a digital drawing of the smile was outlined. Both an analog and a digital wax-up were obtained from two of the 52 models: the latter was obtained using digital impressions and a dedicated software. The analog wax-up was then used to produce 25 matrices that have later been used to mould 25 resin mock-ups using a traditional moulding protocol (Control Group - CG). The digital wax-up was used to mill 25 PMMA mock-ups. Each mock-up, both milled and moulded (total 50), was then laid on the other 50 resin models as a digital impression of it was taken. The STL. files of the milled mock-ups were compared with the 3D CAD wax-up made using a specific software. The STL. files of the analog printed mock-ups were compared with the traditional wax-up design. A statistical analysis was carried out to evaluate the difference between the groups. Results The statistical analysis showed a significant difference (P > 0.01) between the mean value of the distance between the points of the overlapping STL. meshes in GC (0.0468 mm) and in TG (Test Group - TG) (0,0109 mm). Conclusions The study showed a difference in accuracy between traditional moulded and milled mock-ups compared to their original wax-up. The data analysis reports that the digital method allows for greater accuracy. Within the limitations of this study, a fully digital workflow is to considered more reliable when it come to creating an esthetic mockup: the digital procedure has been shown to be more accurate than the one made manually which is much more operator dependent and it brings an increase to the chance of error, and that could ultimately affect the final result.


Materials ◽  
2019 ◽  
Vol 12 (23) ◽  
pp. 4001
Author(s):  
Vincenzo D’Antò ◽  
Simone Muraglie ◽  
Beatrice Castellano ◽  
Ettore Candida ◽  
Maria Francesca Sfondrini ◽  
...  

Background: Attachments are composite auxiliaries that are used during a clear aligner orthodontic therapy to achieve difficult tooth movements. Two important factors are the planned configuration and the actual position of these auxiliary elements to obtain the desired force system. The aim of the present study was to evaluate the role of different composite materials in the correct reproduction of attachment shape and position. Methods: The materials that were considered in the study were a flowable resin, a dental restorative material, and an orthodontic composite. The attachments were created on three models of extracted teeth. Once the impressions were performed, 25 attachments of different shapes were added onto each virtual model to obtain the necessary templates to make the attachments. Each tested material was used to create a set of 25 attachments that were then scanned with an accuracy of 10μm. The resultant STL (stereolithography) files were superimposed onto the ones from the initial virtual plan, through Geomagic software, and the aligned scans were then compared while using a color map. The parameters that were calculated to make a comparison between the created attachments and the ideal ones were the maximum deviation in defect and in excess, the overflow, and the volume’s difference. In addition to these measurements comparing the three above-mentioned groups, the difference in volume between all the ideal and realized samples were analyzed. To test for differences among the three groups, a one-way Analysis of variance (ANOVA) was used with a Bonferroni post-hoc test. The level of significance was set at p < 0.05. Results: No statistically significant results were found between the three groups regarding the maximum value in defect, the maximum value in excess, and the minimum value as control, while a statistically significant difference was found between the overflow of orthodontic resin when compared to the flowable composite. Conclusions: The three materials that were used in this study were appropriate for attachment fabrication. The fidelity of attachment reproduction was similar when using the three different composites. The orthodontic composite showed more overflow when compared with the flowable one.


2015 ◽  
Vol 41 (5) ◽  
pp. 537-541 ◽  
Author(s):  
Rashmi Biyani ◽  
Mohsin Ali ◽  
Donald Belles ◽  
John M. Powers

Purpose: Reducing the height of the implant abutment due to limited interarch space decreases the surface area for retention of cemented restorations. The purpose of this in vitro study was to see whether engaging the screw access channel with metal extension compensates for the loss of retention of posterior crowns cemented on shorter abutments. Material and Methods: Four identical prefabricated abutments were mounted on implant replicas embedded in acrylic resin blocks. Three of these abutments were reduced in height by 1 mm, 2 mm, and 3 mm respectively and one was left unmodified. Two sets of base metal crowns were fabricated for each abutment, one without and one with the metal extension inside the screw access channel. The crowns were cemented using Tempbond NE. The tensile forces required to separate the cemented crowns from abutments were measured using an Instron testing machine. Statistical analysis of the data was performed using a 2-way analysis of variance and Fisher's protected least significant difference at 0.05 level of significance. Results: An increase of 24% to 261% in retentive forces was observed for the group having metal extension in the screw access channel. Statistically significant differences (P &lt; .001) were found among 2 types of crowns and four heights of abutments. Generally, the retentive forces were reduced in magnitude as the abutment height was reduced. Conclusion: The retention of a casting cemented to posterior implant abutments is influenced by the height of the abutment and the metal extension engaging the screw access channel. The crowns made with a metal extension showed superior retention values.


Author(s):  
Praneetha D Rani ◽  
Vijaya Hegde

Introduction: Fluoride toothpastes are a major reason for the decline in dental caries globally. For fluoride toothpaste to be effective, an adequate amount of Total Soluble Fluoride (TSF) must be available in the toothpastes. Aim: To determine and compare the Total Fluoride (TF), TSF and pH among various toothpaste brands. Materials and Methods: An in-vitro study was conducted during October 2019 on 20 toothpaste samples, which belonged to four groups namely, herbal toothpastes group, nonherbal toothpastes group, medicated toothpastes group and kids toothpastes group. Analysis of the samples was done at the Department of Environmental Engineering Laboratory, National Institute of Technology, Surathkal, Karnataka, India. The TF and the TSF concentration was determined using fluoride ion electrode. The pH was determined using pH meter. Statistical analysis was performed using Statistical Package for Social Sciences (SPSS version 19.0). Analysis of variance (ANOVA) was used by Tukey’s post-hoc test to determine the difference between groups. The level of significance was kept at 0.05. Results: The results showed that there was a significant difference between the toothpaste types for mean TF concentration (p=0.004). The post-hoc test showed that there was a significant difference between herbal and nonherbal toothpastes (p=0.041) where the mean TF concentration for nonherbal toothpastes was 1095.20 ppm when compared to herbal toothpastes was 704.40 ppm. The results showed that there was a siginificant difference between the toothpaste types for Mean TSF concentration (p<0.003). There was a significant difference between medicated and kids toothpastes (p=0.024) where the mean total soluble fluoride concentration for medicated toothpastes was 938.60 ppm when compared to the kids toothpastes was 521.20 ppm. Conclusion: The present study showed that pH of all the toothpastes were either neutral or alkaline and the TSF concentration was less when compared to TF concentrations.


Author(s):  
Niloofar Shadman ◽  
Bahareh Pezeshki ◽  
Setare Rostami

Objectives: Bulk fill composites are preferred to conventional composites with time-consuming incremental application technique, given that they have good mechanical properties and low microleakage. The aim of this study was to evaluate and compare the dentinal marginal microleakage of bulk fill (in two viscosities) and conventional composites in class II cavities in maxillary premolars. Materials and Methods: In this in vitro studyˏ 42 class II cavities were prepared in the mesial and distal surfaces of 21 maxillary premolars extending 1 mm below the cementoenamel junction, and restored with Grandio composite with 2-mm increments, and X-tra fil and X-tra base with 4-mm increments. After 24 h of storage at 37oC and 100% humidity, they were thermocycled (500 cyclesˏ 5-55oC), stored in basic fuchsine, sectioned, and evaluated under a stereomicroscope (×40). The microleakage scores of the gingival margin were recorded. Statistical analysis was done by SPSS 21 via the Kruskal-Wallis and Mann-Whitney U tests at P≤0.05 level of significance. Results: No statistically significant differences were noted among the groups in marginal microleakage (P=0.47). No statistically significant difference was noted between bulk and incremental application techniques in this respect either (P=0.23). Conclusion: There was no difference in marginal microleakage between the bulk fill and conventional composites.


2020 ◽  
Vol 9 (5) ◽  
pp. 1436 ◽  
Author(s):  
Tim Joda ◽  
Lea Matthisson ◽  
Nicola U. Zitzmann

The aim of this in vitro study was to analyze the impact of model aging on the accuracy of 3D-printed dental models. A maxillary full-arch reference model with prepared teeth for a three-unit fixed dental prosthesis was scanned ten times with an intraoral scanner (3Shape TRIOS Pod) and ten models were 3D printed (Straumann P-Series). All models were stored under constant conditions and digitized with a desktop scanner after 1 day; 1 week; and 2, 3, and 4 weeks. For accuracy, a best-fit algorithm was used to analyze the deviations of the abutment teeth (GFaI e.V Final Surface®). Wilcoxon Rank Sum Tests were used for comparisons with the level of significance set at α = 0.05. Deviation analysis of the tested models showed homogenous intragroup distance calculations at each timepoint. The most accurate result was for 1 day of aging (3.3 ± 1.3 µm). A continuous decrease in accuracy was observed with each aging stage from day 1 to week 4. A time-dependent difference was statistically significant after 3 weeks (p = 0.0008) and 4 weeks (p < 0.0001). Based on these findings, dental models should not be used longer than 3 to 4 weeks after 3D printing for the fabrication of definitive prosthetic reconstructions.


Author(s):  
Rathika Rai ◽  
M. A. Easwaran ◽  
K. T. Dhivya

Aim: To evaluate the surface detail reproduction of dental stone this is immersed in different disinfectant solution and studied under stereomicroscope. Methodology: Total number of 30 specimens of dental stone (Type III) were made with measurements of 1.5cm diameter and 1cm height .This samples are divided in to 3 groups group A,B,C. were A is immersed in Distilled water which was taken as control group ;B is immersed in 2% Glutaraldehyde and C is immersed in 5%sodium hypochlorite. Each specimen were immersed in the disinfectant solution for 15 minutes and dried under room temperature for 24 hrs. After 24 hrs each specimens are studied under stereomicroscope for surface details. Result: The results showed no significant difference in the surface irregularities and porosities for a group 1 and group 2 except group 3 which showed significant increase in the porosities, surface irregularities and erosions after disinfection with 5% NaHOCl by immersion method. Conclusion: The surface detail reproduction capacity of die stone was adversely affected when 5% Sodium hypochlorite was used as disinfectant solution when compare d to control group and 2% Glutaraldehyde


2021 ◽  
Vol 11 (2) ◽  
pp. 857
Author(s):  
Keunbada Son ◽  
Kyu-Bok Lee

The purpose of this in vitro study was to evaluate marginal and internal fits of ceramic crowns fabricated with chairside computer-aided design and manufacturing (CAD/CAM) systems. An experimental model based on ISO 12836:2015 was digitally scanned with different intraoral scanners (Omnicam (CEREC), EZIS PO (DDS), and CS3500 (Carestream)). Ceramic crowns were fabricated using the CAD/CAM process recommended by each system (CEREC, EZIS, and Carestream systems; N = 15). The 3-dimensional (3D) marginal and internal fit of each ceramic crown was measured using a 3D inspection software (Geomagic control X). Differences among the systems and various measurements were evaluated using the Kruskal–Wallis test. Statistically significant differences were validated using pairwise comparisons (α = 0.05). Occlusal gaps in the CEREC, EZIS, and Carestream groups were 113.0, 161.3, and 438.2 µm, respectively (p < 0.001). The axial gaps were 83.4, 78.0, and 107.9 µm, respectively. The marginal gaps were 77.8, 99.3, and 60.6 µm, respectively, and the whole gaps were 85.9, 107.3, and 214.0 µm, respectively. Significant differences were observed with the EZIS system compared with the other two systems in terms of the marginal gap sizes. The CEREC system showed no significant differences among the four measured regions. However, the EZIS and Carestream systems did show a statistically significant difference (p < 0.05). All three systems were judged to be capable of fabricating clinically acceptable prostheses, because the marginal gap, which is the most important factor in the marginal fit of prostheses, was recorded to be below 100 µm in all three systems.


2015 ◽  
Vol 85 (6) ◽  
pp. 920-926 ◽  
Author(s):  
Ricardo Carvalho Bueno ◽  
Roberta Tarkany Basting

ABSTRACT Objective:  To evaluate the proliferation and morphology of human osteoblasts cultured on two brands of mini-implants after 24, 48, and 72 hours, in addition to the chemical composition found on their surface. Materials and Methods:  Two brands of mini-implant (Morelli and Neodent) were evaluated; polystyrene was used as a control group (n  =  3). Osteoblasts were cultured on the surface of sterilized mini-implants in a CO2 incubator at different time periods (24, 48, and 72 hours). Osteoblast proliferation was quantified by scanning electron microscopy using up to 5000× magnification, and cell morphology was analyzed by a single observer. For the chemical analysis, spectroscopy X-ray fluorescence was used to identify and quantify chemical components on the surface of the mini-implants. Results:  Two-way ANOVA showed no significant interaction between the factors studied (P  =  0.686). A Tukey test revealed no significant difference in osteoblast proliferation between the mini-implants at all studied periods; however, a difference in cell proliferation was detected between the Neodent and the control group (P  =  .025). For all groups, time had a direct and positive effect on osteoblast proliferation (P &lt; .001). The significant elements present in both brands of mini-implants were titanium, aluminum, vanadium, and iron. Conclusions:  Osteoblast proliferation was present on the mini-implants studied, which increased over time; however, no significant difference between brands was observed. No difference was seen between the mini-implants evaluated in terms of chemical composition. Cell adhesion after 72 hours suggests that areas of bone remodeling can be achieved, thus initiating the process of mini-implant anchorage.


Sign in / Sign up

Export Citation Format

Share Document