scholarly journals Bottom-Up Synthesis of Mesoporous TiO2 Films for the Development of Optical Sensing Layers

Chemosensors ◽  
2021 ◽  
Vol 9 (12) ◽  
pp. 329
Author(s):  
David Ortiz de Zárate ◽  
Sara Serna ◽  
Salvador Ponce-Alcántara ◽  
Miroslavna Kovylina ◽  
Jaime García-Rupérez

Many optical sensors exploit the interesting properties of porous materials, as they ensure a stronger interaction between the light and the analyte directly within the optical structure. Most porous optical sensors are mainly based on porous silicon and anodized aluminum oxide, showing high sensitivities. However, the top-down strategies usually employed to produce those materials might offer a limited control over the properties of the porous layer, which could affect the homogeneity, reducing the sensor reproducibility. In this work, we present the bottom-up synthesis of mesoporous TiO2 Fabry-Pérot optical sensors displaying high sensitivity, high homogeneity, and low production cost, making this platform a very promising candidate for the development of high-performance optical sensors.

Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 806
Author(s):  
Ning Wang ◽  
Wenhao Tian ◽  
Haosheng Zhang ◽  
Xiaodan Yu ◽  
Xiaolei Yin ◽  
...  

An easily fabricated Fabry-Perot optical fiber humidity sensor with high performance was presented by filling Graphene Quantum Dots (GQDs) into the Fabry-Perot resonator, which consists of two common single mode optical fibers. The relative humidity sensing performance was experimentally investigated by an interference spectrum drift between 11 %RH to 85 %RH. 0.567 nm/%RH sensitivity and 0.99917 linear correlation were found in experiments that showed high sensitivity, good and wide-range linear responding. Meanwhile, its good responding repeatability was demonstrated by two circle tests with increasing and decreasing relative humidity. For investigating the measurement influence caused by a temperature jitter, the temperature responding was experimentally investigated, which showed its linear responding with 0.033 nm/°C sensitivity. The results demonstrate the humidity sensitivity is greatly higher than the temperature sensitivity. The wavelength shift influence is 0.0198 nm with 0.6 °C max temperature jitter in the experiment, which can be ignored in humidity experiments. The fast-dynamic responses at typical humidity were demonstrated in experiments, with 5.5 s responding time and 8.5 s recovering time. The sensors with different cavity lengths were also investigated for their humidity response. All sensors gave good linear responding and high sensitivity. In addition, the relation curve between cavity length and response sensitivity also had good linearity. The combination of GQDs and single mode optical fibers showed easy fabrication and good performance for an optical fiber relative humidity sensor.


Author(s):  
Xiaodong Yang ◽  
Bowen Geng ◽  
Junqing Wei ◽  
Zhi Wang ◽  
Kuibo Lan ◽  
...  

Abstract Flexible integrated circuits (ICs) have gained a lot of attentions in recent years for their emerging application in wearable electronics. Flexible thin-film transistors (TFTs) with low-cost and high-performance are highly desirable as essential and fundamental element for most of the flexible applications. In this paper, we fabricated single-crystalline silicon nanomembrane (SiNM) based TFTs with anodized aluminum oxide (AAO) as dielectric material on glass and flexible plastic substrates. Good quality AAO was obtained on plastic substrates at room temperature. AFM was used for surface morphology of AAO gate dielectric layers on different substrates (i.e. glass, polyethylene terephthalate (PET) and SU-8 coated PET). The electrical characteristics of the AAO gate dielectric layers on different substrates were also analyzed with metal- dielectric-metal (MIM) capacitors. SiNMs were processed with complementary metal oxide semiconductor (CMOS) compatible semiconductor process (e.g. photolithography, ion implantation, thermal annealing, reactive ion etching, metal evaporation, etc.), and then transferred to the substrates with AAO/aluminum stack layers. Performances of transistors on glass and plastic substrates were characterized. Compared with the TFT fabricated on glass substrate, TFT fabricated directly on a PET substrate have lower performance due to poor surface roughness. For optimization of the surface roughness, PET was modified with coating SU-8 photoresist. By this way, TFT had properties close to that on glass substrate. AAO that can be manufactured at room temperature provides a simple and low-cost solution for high-performance flexible single-crystalline SiNM TFTs.


2018 ◽  
Vol 277 ◽  
pp. 152-156 ◽  
Author(s):  
Huihui Zhu ◽  
Jian-Jun He ◽  
Liyang Shao ◽  
Mingyu Li

2020 ◽  
Vol 23 (10) ◽  
pp. 1010-1022
Author(s):  
Emrah Dural

Aim and scope: Due to the serious toxicological risks and their widespread use, quantitative determination of phthalates in cosmetic products have importance for public health. The aim of this study was to develop a validated simple, rapid and reliable high-performance liquid chromatography (HPLC) method for the determination of phthalates which are; dimethyl phthalate (DMP), diethyl phthalate (DEP), benzyl butyl phthalate (BBP), di-n-butyl phthalate (DBP), di(2- ethylhexyl) phthalate (DEHP), in cosmetic products and to investigate these phthalate (PHT) levels in 48 cosmetic products marketing in Sivas, Turkey. Materials and Methods: Separation was achieved by a reverse-phase ACE-5 C18 column (4.6 x 250 mm, 5.0 μm). As the mobile phase, 5 mM KH2PO4 and acetonitrile were used gradiently at 1.5 ml min-1. All PHT esters were detected at 230 nm and the run time was taking 21 minutes. Results: This method showed the high sensitivity value the limit of quantification (LOQ) values for which are below 0.64 μg mL-1 of all phthalates. Method linearity was ≥0.999 (r2). Accuracy and precision values of all phthalates were calculated between (-6.5) and 6.6 (RE%) and ≤6.2 (RSD%), respectively. Average recovery was between 94.8% and 99.6%. Forty-eight samples used for both babies and adults were successfully analyzed by the developed method. Results have shown that, DMP (340.7 μg mL-1 ±323.7), DEP (1852.1 μg mL-1 ± 2192.0), and DBP (691.3 μg mL-1 ± 1378.5) were used highly in nail polish, fragrance and cream products, respectively. Conclusion: Phthalate esters, which are mostly detected in the content of fragrance, cream and nail polish products and our research in general, are DEP (1852.1 μg mL-1 ± 2192.0), DBP (691.3 μg mL-1 ± 1378.5) and DMP (340.7 μg mL-1 ±323.7), respectively. Phthalates were found in the content of all 48 cosmetic products examined, and the most detected phthalates in general average were DEP (581.7 μg mL-1 + 1405.2) with a rate of 79.2%. The unexpectedly high phthalate content in the examined cosmetic products revealed a great risk of these products on human health. The developed method is a simple, sensitive, reliable and economical alternative for the determination of phthalates in the content of cosmetic products, it can be used to identify phthalate esters in different products after some modifications.


2018 ◽  
Vol 15 (1) ◽  
pp. 67-73 ◽  
Author(s):  
Guiyun Cao ◽  
Suqiao Han ◽  
Keke Li ◽  
Li Shen ◽  
Xiaohong Wang ◽  
...  

Background: Ferruginol (FRGN) exhibits a broad range of pharmacological properties which make it a promising candidate for chemoprevention. However, little is known about its absorption, distribution, metabolism, excretion, and toxicity (ADMET) properties. Methods: A rapid, sensitive and specific HPLC-DAD method was established to quantify FRGN in the plasma and tissues of Wistar rats. After extraction of FRGN with ethyl acetate (EtOAc), chromatographic separation was performed on a YMC ODS C18 column (250 × 4.6 mm I.D., 5 µm) with a mobile phase consisting of methanol-water (92:8, v/v) at a flow rate of 0.9 mL/min. Detection was conducted with a wavelength of 273 nm at 25 °C. Results: The calibration curves for FRGN were linear in the concentration range of 0.5-20 µg/mL for plasma, 0.5-10 µg/mL for heart, liver, spleen, lung, kidney, stomach, intestine, brain and muscle. After three cycles of freezing and thawing, the concentration variations were within ± 7% of nominal concentrations, indicating no significant substance loss during repeated thawing and freezing. The assay was applied to pharmacokinetic and tissue distribution study in rats. Results suggested that lung, heart, liver, spleen and kidney were the major distribution tissues of FRGN in rats, and FRGN could permeate the blood-brain barrier to distribute in the brain of rats. Conclusion: The information provided by this research is very useful for gaining knowledge of the pharmacokinetic process and tissue distribution of FRGN.


Nanophotonics ◽  
2020 ◽  
Vol 9 (5) ◽  
pp. 1081-1086 ◽  
Author(s):  
Abdoulaye Ndao ◽  
Liyi Hsu ◽  
Wei Cai ◽  
Jeongho Ha ◽  
Junhee Park ◽  
...  

AbstractOne of the key challenges in biology is to understand how individual cells process information and respond to perturbations. However, most of the existing single-cell analysis methods can only provide a glimpse of cell properties at specific time points and are unable to provide cell secretion and protein analysis at single-cell resolution. To address the limits of existing methods and to accelerate discoveries from single-cell studies, we propose and experimentally demonstrate a new sensor based on bound states in the continuum to quantify exosome secretion from a single cell. Our optical sensors demonstrate high-sensitivity refractive index detection. Because of the strong overlap between the medium supporting the mode and the analytes, such an optical cavity has a figure of merit of 677 and sensitivity of 440 nm/RIU. Such results facilitate technological progress for highly conducive optical sensors for different biomedical applications.


Sensors ◽  
2021 ◽  
Vol 21 (6) ◽  
pp. 2163
Author(s):  
Dongjin Kim ◽  
Seungyong Han ◽  
Taewi Kim ◽  
Changhwan Kim ◽  
Doohoe Lee ◽  
...  

As the safety of a human body is the main priority while interacting with robots, the field of tactile sensors has expanded for acquiring tactile information and ensuring safe human–robot interaction (HRI). Existing lightweight and thin tactile sensors exhibit high performance in detecting their surroundings. However, unexpected collisions caused by malfunctions or sudden external collisions can still cause injuries to rigid robots with thin tactile sensors. In this study, we present a sensitive balloon sensor for contact sensing and alleviating physical collisions over a large area of rigid robots. The balloon sensor is a pressure sensor composed of an inflatable body of low-density polyethylene (LDPE), and a highly sensitive and flexible strain sensor laminated onto it. The mechanical crack-based strain sensor with high sensitivity enables the detection of extremely small changes in the strain of the balloon. Adjusting the geometric parameters of the balloon allows for a large and easily customizable sensing area. The weight of the balloon sensor was approximately 2 g. The sensor is employed with a servo motor and detects a finger or a sheet of rolled paper gently touching it, without being damaged.


Sign in / Sign up

Export Citation Format

Share Document