scholarly journals Effects of Water Content and Temperature on Bulk Resistivity of Hybrid Cement/Carbon Nanofiber Composites

Materials ◽  
2020 ◽  
Vol 13 (13) ◽  
pp. 2884 ◽  
Author(s):  
Kamila Gawel ◽  
Mohammad Ali Taghipour Khadrbeik ◽  
Ruben Bjørge ◽  
Sigurd Wenner ◽  
Bartlomiej Gawel ◽  
...  

Cement nanocomposites with carbon nanofibers (CNFs) are electrically conductive and sensitive to mechanical loads. These features make them useful for sensing applications. The conductive and load sensing properties are well known to be dependent on carbon nanofiber content; however, much less is known about how the conductivity of hybrid cement–CNF depend on other parameters (e.g., water to cement ratio (w/c), water saturation of pore spaces and temperatures above ambient temperature). In this paper we fill-in these knowledge gaps by: (1) determining a relationship between the cement–CNF bulk resistivity and w/c ratio; (2) determining the effect of water present in the pores on bulk resistivity; (3) describing the resistivity changes upon temperature changes up to 180 °C. Our results show that the increase in the water to cement ratio results in increased bulk resistivity. The decrease in nanocomposite resistivity upon a stepwise temperature increase up to 180 °C was found to be related to free water release from cement pores and the dry materials were relatively insensitive to temperature changes. The re-saturation of pores with water was not reversible with respect to electrical resistivity. The results also suggest that the change in the type of electrical connection can lead to two orders of magnitude different bulk resistivity results for the same material. It is expected that the findings from this paper will contribute to application of cement–CNF-based sensors at temperatures higher than ambient temperature.

1982 ◽  
Vol 15 ◽  
Author(s):  
Nabil Morcos ◽  
Ramesh Dayal ◽  
Laurence Milian ◽  
Philip Hayde ◽  
Allen J. Weiss

ABSTRACTA study correlating the leachability of 137 Cs from small-scale to large-scale cement forms was performed. The waste forms consisted of (a) organic ion exchange resins incorporated in Portland I cement, with a waste-to-cement ratio of 0.6 and a water-to-cement ratio of 0.4 (as free water) and (b) boric acid waste (12% solution) incorporated in Portland III cement, with a waste-to-cement ratio of 0.7. 137Cs was added to both waste types prior to solidification. The sample dimensions varied from 1 in. ×1 in. to 22 in. × 22 in. (diameter × height). Leach data extending over a period of 260 days were obtained using a modified IAEA leach test. A method based on semi-infinite plane source diffusion model was applied to interpret the leach data, which allows prediction of the amount of 137Cs leached from the forms as a function of leaching time and waste form dimensions. A reasonably good agreement between the experimental and calculated data was obtained for both types of cement waste forms.


Crystals ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 240
Author(s):  
Jianlan Chen ◽  
Jiandong Wang ◽  
Rui He ◽  
Huaizhu Shu ◽  
Chuanqing Fu

This study investigated the effective chloride diffusion coefficient of cement mortar with different water-to-cement ratio (w/c) under electrical accelerated migration measurement. The cumulative chloride concentration in anode cell solution and the cumulative chloride concentration drop in the cathode cell solution was measured by RCT measurement and the results were further used to calculate the chloride diffusion coefficient by Nordtest Build 355 method and Truc method. The influence of w/c on cement mortar’s chloride coefficient was investigated and the chloride diffusion coefficient under different determination methods were compared with other researchers’ work, a good consistency between this work’s results and literatures’ results was obtained. The results indicated that the increased w/c of cement mortar samples will have a higher chloride diffusion coefficient. The cumulative chloride concentration drop in the cathode cell solution will have deviation in early stage measurement (before 60 h) which will result in overestimation of the effective chloride diffusion coefficient.


1975 ◽  
Vol 53 (6) ◽  
pp. 679-685 ◽  
Author(s):  
J. B. Holter ◽  
W. E. Urban Jr. ◽  
H. H. Hayes ◽  
H. Silver ◽  
H. R. Skutt

Six adult white-tailed deer (Odocoileus virginianus borealis) were exposed to 165 periods of 12 consecutive hours of controlled constant ambient temperature in an indirect respiration calorimeter. Temperatures among periods varied from 38 to 0 (summer) or to −20C (fall, winter, spring). Traits measured were energy expenditure (metabolic rate), proportion of time spent standing, heart rate, and body temperature, the latter two using telemetry. The deer used body posture extensively as a means of maintaining body energy equilibrium. Energy expenditure was increased at low ambient temperature to combat cold and to maintain relatively constant body temperature. Changes in heart rate paralleled changes in energy expenditure. In a limited number of comparisons, slight wind chill was combatted through behavioral means with no effect on energy expenditure. The reaction of deer to varying ambient temperatures was not the same in all seasons of the year.


2012 ◽  
Vol 730-732 ◽  
pp. 271-276
Author(s):  
H.R. Pakravan ◽  
M. Jamshidi ◽  
M. Latifi ◽  
F. Pacheco-Torgal

This paper compares the adhesion strength between three polymeric fibres (polypropylene (PP), nylon66 (N66) and polyacrylonitrile (PAN)) embedded in a cement paste. The specimens were prepared at a water to cement ratio (w/c) of 0.5 and tested after 7, 14 and 28 curing days. It was found that although the adhesion between the polymeric fibres to the cement matrix is an important factor, the energy absorption capacity or energy dissipation ability of the fibres, plays a more important role in the improvement of the cementitious composites fracture toughness. Scanning electron micrographs were used to characterize the fibres surface before and after the Pull-out tests.


2021 ◽  
Vol 11 (16) ◽  
pp. 7558
Author(s):  
Tingting Gu ◽  
Xiaoming Qian ◽  
Peihuang Lou

The crankshaft online measurement system has realized the full inspection function with fast beats, at the same time it requires for high-precision measurement. Considering the effect of ambient temperature and temperature changes on measuring machine, the calibration part, the measured crankshaft and displacement sensor, a temperature compensation method is proposed. Firstly, relationship between calibration part and ambient temperature can be get through the zero calibration. Then use the material properties to obtain compensation values of the calibration part and the measured crankshaft part at different temperatures. Finally, the compensation parameters for displacement sensor can be obtained through the BP algorithm. The improved dragonfly algorithm (DA) is used to optimize the parameters of BP neural network algorithm. Experiments verify the effectiveness of IDA-BP for LVDT in temperature compensation. After temperature compensation, the error range of main journal radius is reduced from 0.0156 mm to 0.0028 mm, the residual error decreased from −0.0282 mm~+0.0018 mm to −0.0058 mm~−0.0008 mm. The influence of temperature changes on the measurement is reduced and measurement accuracy is improved through the temperature compensation method. The effectiveness of the method is proved.


1990 ◽  
Vol 17 (1) ◽  
pp. 102-112
Author(s):  
T. Rezansoff ◽  
D. Stott

The influence of CaCl2 or a chloride-based accelerating admixture on the freeze–thaw resistance of concrete was evaluated. Three air entrained mix designs were investigated using ASTM C666-84, Standard Test Method for Resistance of Concrete to Rapid Freezing and Thawing. All mix designs were similar, using cement contents of 340–357 kg/m3 of concrete, except for the addition of either 2% calcium chloride or 2% High Early Pozzolith, while no accelerating admixture was added to the control mix. The entire test program was repeated four times with water-to-cement ratio of 0.46 and three times with the ratio of 0.43. For the Pozzolith-accelerated concrete, half the samples were coated with boiled linseed oil in all seven series. For the control (unaccelerated) concrete, half the samples were coated with boiled linseed oil in one series for each water-to-cement ratio. Performance was monitored using the dynamic modulus of elasticity as obtained from transverse resonant frequency measurements. Weight loss of the specimens was also measured. Only the control samples (no accelerators) showed sufficient durability to satisfy the standard of maintaining at least 60% of the original dynamic modulus after 300 cycles of alternate freezing and thawing. Sealing with linseed oil showed inconsistent improvement in the durability in the various test series when defined in terms of the dynamic modulus; however, weight losses were the lowest of all categories and surface scaling was minimal. Key words: concrete, durability, freeze–thaw testing, calcium chloride, admixtures, sealants, air void system.


2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Kanwaldeep Singh ◽  
Sukhpal Singh ◽  
Gurmel Singh

Six concrete mixtures were prepared with 0%, 20%, 30%, 40%, 50%, and 60% of flyash replacing the cement content and having constant water to cement ratio. The testing specimens were casted and their mechanical parameters were tested experimentally in accordance with the Indian standards. Results of mechanical parameters show their improvement with age of the specimens and results of radiation parameters show no significant effect of flyash substitution on mass attenuation coefficient.


2021 ◽  
Vol 888 ◽  
pp. 67-75
Author(s):  
Ariel Verzosa Melendres ◽  
Napoleon Solo Dela Cruz ◽  
Araceli Magsino Monsada ◽  
Rolan Pepito Vera Cruz

Chloride ingress into concrete from the surrounding environment can result in the corrosion of the embedded steel reinforcement and cause damage to the concrete. Superabsorbent polymer (SAP) with fine particle size was incorporated into the structure of concrete for controlling the chloride ingress and improving its compressive strength via promotion of internal curing. The SAP used in this study was evaluated for its absorbency property when exposed to cementitious environment such as aqueous solution of Ca (OH)2 and cement slurry. The results were compared to that in sodium chloride solution, the environment where absorbency of most of the SAP found in the market are well studied. Results showed that although SAP absorbency decreased with increasing concentration of Ca (OH)2 and cement, the results suggest that water containing cementitious materials are able to be absorbed by SAP. Chloride ingress into 28-day cured concrete specimens were determined using Rapid Chloride Penetration Test (RCPT) method employing 60V DC driving force. Concrete samples with size of 50 mm height x 100 mm diameter were prepared using a M25 mix design with 0.4 and 0.45 water to cement ratios and different percentages of SAP such as 0.05%, 0.1% and 0.15% with respect to cement mass. Results showed that concrete with 0.15% SAP gave the best result with 14% less chloride permeability than concrete with no SAP for a 0.4 water to cement ratio. Concrete samples for compressive strength tests with size of 200 mm height x 100 mm diameter were prepared using the same mix design and percentages of SAP and cured for 28 days. Results showed that the best results for compressive strength was found at 0.1% SAP at a 0.4 water to cement ratio which can be attributed to internal curing provided by SAP.


Sign in / Sign up

Export Citation Format

Share Document