scholarly journals Numerical Analysis of the Effect of Ground Dampness on Heat Transfer between Greenhouse and Ground

2021 ◽  
Vol 13 (6) ◽  
pp. 3084
Author(s):  
Grzegorz Nawalany ◽  
Paweł Sokołowski

This paper deals with the problem of the influence of ground dampness on heat exchange between greenhouse and ground. The effect of humidity on the distribution of ground temperature fields was analyzed. The analysis was performed based on the analytical numerical method in the WUFI®plus software. The computational tool was used after a validation process. Research and simulations were conducted on the example of a real single-span greenhouse located in Southern Poland. The results of indoor and outdoor air temperature measurements were used to determine the boundary conditions, while the measured ground temperatures were used to compare with the results of theoretical calculations. Three variants were used for calculation analysis, assuming different levels of ground dampness. Analysis of the test results showed that during the summer period, dry ground provides 8% more thermal energy to the interior of the greenhouse than the damp ground, and provides 30% more thermal energy than wet ground. In the transition period (autumn/spring), the ground temperature fields are arranged parallel to the floor level, while the heat flux is directed from the ground to the interior of the greenhouse, regardless of the ground dampness level. During this period, the ground temperature ranges from 4.0 °C to 13.0 °C. Beneficial effect of dry ground, which contributes to maintaining an almost constant temperature under the greenhouse floor, was found in winter.

2010 ◽  
Vol 4 (4) ◽  
pp. 1877-1908 ◽  
Author(s):  
B. Etzelmüller ◽  
T. V. Schuler ◽  
K. Isaksen ◽  
H. H. Christiansen ◽  
H. Farbrot ◽  
...  

Abstract. Variations in ground thermal conditions in Svalbard were studied based on measurements and theoretical calculations. Ground temperature data was used to calibrate a transient heat flow model describing depth and time variations in temperatures. The model was subsequently forced with historical surface air temperature data records and downscaled global climate model runs to project ground temperatures. We discuss ground temperature development since the early 20th century, and the thermal responses in relation to ground characteristics and snow cover. The modelled ground temperatures show a gradually increase since the end of the Little Ice Age (mid 19th century on Svalbard), by about 1.5 °C to 2 °C at 20 m depth. The active layer thickness (ALT) is modelled to have increased slightly, with the rate of increase depending on water content of the near-surface layers. The used scenario runs predict a significant increase in ground temperatures and an increase of ALT depending on soil characteristics.


Geofluids ◽  
2019 ◽  
Vol 2019 ◽  
pp. 1-26 ◽  
Author(s):  
Helge Skarphagen ◽  
David Banks ◽  
Bjørn S. Frengstad ◽  
Harald Gether

Borehole thermal energy storage (BTES) exploits the high volumetric heat capacity of rock-forming minerals and pore water to store large quantities of heat (or cold) on a seasonal basis in the geological environment. The BTES is a volume of rock or sediment accessed via an array of borehole heat exchangers (BHE). Even well-designed BTES arrays will lose a significant quantity of heat to the adjacent and subjacent rocks/sediments and to the surface; both theoretical calculations and empirical observations suggest that seasonal thermal recovery factors in excess of 50% are difficult to obtain. Storage efficiency may be dramatically reduced in cases where (i) natural groundwater advection through the BTES removes stored heat, (ii) extensive free convection cells (thermosiphons) are allowed to form, and (iii) poor BTES design results in a high surface area/volume ratio of the array shape, allowing high conductive heat losses. The most efficient array shape will typically be a cylinder with similar dimensions of diameter and depth, preferably with an insulated top surface. Despite the potential for moderate thermal recovery, the sheer volume of thermal storage that the natural geological environment offers can still make BTES a very attractive strategy for seasonal thermal energy storage within a “smart” district heat network, especially when coupled with more efficient surficial engineered dynamic thermal energy stores (DTES).


2020 ◽  
Vol 15 (7) ◽  
pp. 950-957
Author(s):  
G.D. Mezhetskiy ◽  
◽  
V.A. Strelnikov ◽  

The article presents the results of studies of the thermal fatigue strength of diesel cylinder heads and their resource under operating conditions, by using the most advanced technology for their restoration. Based on the results of theoretical calculations of durability and operational studies, a restoration technology has been proposed, which makes it possible to increase the resource of cylinder heads by 2 ÷ 2.5 times. For this purpose, the non-uniformity of the temperature field on the firing bottom of the cylinder heads of YaMZ-238NB diesel engines was theoretically determined and experimentally confirmed. On the basis of theoretical calculations, the most heatstressed sections of the plane of the cylinder heads of diesel engines bonded to the cylinder block were determined, and the appearance of cracks in them. When developing a method for calculating the temperature fields of the fire bottom, the universal finite element method (FEM) was used. This method makes it possible to take into account the geometry and conditions of thermal loading of the cylinder heads quite accurately. For the determination of temperature fields, a well-founded assignment of the boundary conditions is crucial. With this in mind, a number of surfaces were determined that characterize the durability of the entire part during operation. As a result of calculations carried out on a computer, temperature fields have been obtained that make it possible to analyze the distribution of temperatures and temperature gradients at any point of the fire bottom. The highest temperatures (620...635K) are localized in the central part of the fire bottom, which is two times higher in thermal intensity than the peripheral one and confirms the appearance of cracks in these places during the operation of diesel cylinder heads.


2021 ◽  
Author(s):  
Cameron Ross ◽  
Ryley Beddoe ◽  
Greg Siemens

<p>Initialization (spin-up) of a numerical ground temperature model is a critical but often neglected step for solving heat transfer problems in permafrost. Improper initialization can lead to significant underlying model drift in subsequent transient simulations, distorting the effects on ground temperature from future climate change or applied infrastructure.  In a typical spin-up simulation, a year or more of climate data are applied at the surface and cycled repeatedly until ground temperatures are declared to be at equilibrium with the imposed boundary conditions, and independent of the starting conditions.</p><p>Spin-up equilibrium is often simply declared after a specified number of spin-up cycles. In few studies, equilibrium is visually confirmed by plotting ground temperatures vs spin-up cycles until temperatures stabilize; or is declared when a certain inter-cycle-temperature-change threshold is met simultaneously at all depths, such as ∆T ≤ 0.01<sup>o</sup>C per cycle. In this study, we investigate the effectiveness of these methods for determining an equilibrium state in a variety of permafrost models, including shallow and deep (10 – 200 m), high and low saturation soils (S = 100 and S = 20), and cold and warm permafrost (MAGT = ~-10 <sup>o</sup>C and >-1 <sup>o</sup>C). The efficacy of equilibrium criteria 0.01<sup>o</sup>C/cycle and 0.0001<sup>o</sup>C/cycle are compared. Both methods are shown to prematurely indicate equilibrium in multiple model scenarios.  Results show that no single criterion can programmatically detect equilibrium in all tested models, and in some scenarios can result in up to 10<sup>o</sup>C temperature error or 80% less permafrost than at true equilibrium.  A combination of equilibrium criteria and visual confirmation plots is recommended for evaluating and declaring equilibrium in a spin-up simulation.</p><p>Long-duration spin-up is particularly important for deep (10+ m) ground models where thermal inertia of underlying permafrost slows the ground temperature response to surface forcing, often requiring hundreds or even thousands of spin-up cycles to establish equilibrium. Subsequent transient analyses also show that use of a properly initialized 100 m permafrost model can reduce the effect of climate change on mean annual ground temperature of cold permafrost by more than 1 <sup>o</sup>C and 3 <sup>o</sup>C under RCP2.6 and RCP8.5 climate projections, respectively, when compared to an identical 25 m model. These results have important implications for scientists, engineers and policy makers that rely on model projections of long-term permafrost conditions.</p>


Author(s):  
Luis San Andrés ◽  
Feng Yu ◽  
Kostandin Gjika

Engine oil lubricated (semi) floating ring bearing (S)FRB systems in passenger vehicle turbochargers (TC) operate at temperatures well above ambient and must withstand large temperature gradients that can lead to severe thermo-mechanical induced stresses. Physical modeling of the thermal energy flow paths and an effective thermal management strategy are paramount to determine safe operating conditions ensuring the TC component mechanical integrity and the robustness of its bearing system. On occasion, the selection of one particular bearing parameter to improve a certain performance characteristic could be detrimental to other performance characteristics of a TC system. The paper details a thermohydrodynamic model to predict the hydrodynamic pressure and temperature fields and the distribution of thermal energy flows in the bearing system. The impact of the lubricant supply conditions (pressure and temperature), bearing film clearances, oil supply grooves on the ring ID surface are quantified. Lubricating a (S)FRB with either a low oil temperature or a high supply pressure increases (shear induced) heat flow. A lube high supply pressure or a large clearance allow for more flow through the inner film working towards drawing more heat flow from the hot journal, yet raises the shear drag power as the oil viscosity remains high. Nonetheless, the peak temperature of the inner film is not influenced much by the changes on the way the oil is supplied into the film as the thermal energy displaced from the hot shaft into the film is overwhelming. Adding axial grooves on the inner side of the (S)FRB improves its dynamic stability, albeit increasing the drawn oil flow as well as the drag power and heat flow from the shaft. The predictive model allows to identify a compromise between different parameters of groove designs thus enabling a bearing system with a low power consumption.


2019 ◽  
Vol 10 (2) ◽  
pp. 59-66
Author(s):  
E. A Biryuzova ◽  
A. S Glukhanov

Through pipelines of heat networks, due to their large length, a large amount of thermal energy is lost. Identification of technical solutions related to improving the energy efficiency of heating networks is an urgent task at present. The article is devoted to the consideration of options for laying pipelines of heat networks during design work. In the conducted studies, two main methods of underground laying of pipelines of heat networks with the choice of the most energy-efficient, with minimal losses of thermal energy are considered. Channel and channelless laying methods are investigated with the same design features and technological conditions of operation of pipelines of heat networks using the same thermal insulation material. For each option, the required thickness of the thermal insulation is determined by the normalized density of the heat flow, thermal calculations are performed to determine the heat loss and the value of the temperature fields generated around the operating pipelines of the heat networks. The obtained values of the thermal insulation thickness in the channel method of laying pipelines are 30-50 % lower than those in channelless laying. The heat loss values, according to the results of the heat calculation for the options under consideration, in the channel method of laying are reduced by 47-65 %. The temperature fields formed around the pipelines of thermal networks with channelless laying significantly exceed the natural value of the soil temperature at the depth of the pipeline. What has a great influence on the determination of the distance to adjacent pipelines and other utilities, laid underground, in the zone of the thermal network. A comparative analysis of the results obtained makes it possible to single out the choice of the method of laying the pipeline into a group of measures aimed at energy saving and increasing energy efficiency in heating systems.


2021 ◽  
Author(s):  
Andreas Kellerer-Pirklbauer ◽  
Gerhard Karl Lieb

<p>Ground temperatures in alpine environments are severely influenced by slope orientation (aspect), slope inclination, local topoclimatic conditions, and thermal properties of the rock material. Small differences in one of these factors may substantially impact the ground thermal regime, weathering by freeze-thaw action or the occurrence of permafrost. To improve the understanding of differences, variations, and ranges of ground temperatures at single mountain summits, we studied the ground thermal conditions at a triangle-shaped (plan view), moderately steep pyramidal peak over a two-year period (2018-2020).</p><p>We installed 18 monitoring sites with 23 sensors near the summit of Innerer Knorrkogel (2882m asl), in summer 2018 with one- and multi-channel datalogger (Geoprecision). All three mountain ridges (east-, northwest-, and southwest-facing) and flanks (northeast-, west-, and south-facing) were instrumented with one-channel dataloggers at two different elevations (2840 and 2860m asl) at each ridge/flank to monitor ground surface temperatures. Three bedrock temperature monitoring sites with shallow boreholes (40cm) equipped with three sensors per site at each of the three mountain flanks (2870m asl) were established. Additionally, two ground surface temperature monitoring sites were installed at the summit.</p><p>Results show remarkable differences in mean annual ground temperatures (MAGT) between the 23 different sensors and the two years despite the small spatial extent (0.023 km²) and elevation differences (46m). Intersite variability at the entire mountain pyramid was 3.74°C in 2018/19 (mean MAGT: -0.40°C; minimum: -1.78°C; maximum: 1.96°C;) and 3.27°C in 2019/20 (mean MAGT: 0.08°C; minimum: -1.54°C; maximum: 1,73°C;). Minimum was in both years at the northeast-facing flank, maximum at the south-facing flank. In all but three sites, the second monitoring year was warmer than the first one (mean +0.48°C) related to atmospheric differences and site-specific snow conditions. The comparison of the MAGT-values of the two years (MAGT-2018/19 minus MAGT-2019/20) revealed large thermal inhomogeneities in the mountain summit ranging from +0.65° (2018/19 warmer than 2019/20) to -1.76°C (2018/19 colder than 2019/20) at identical sensors. Temperature ranges at the three different aspects but at equal elevations were 1.7-2.2°C at ridges and 1.8-3.7°C at flanks for single years. The higher temperature range for flank-sites is related to seasonal snow cover effects combined with higher radiation at sun-exposed sites. Although the ground temperature was substantially higher in the second year, the snow cover difference between the two years was variable. Some sites experienced longer snow cover periods in the second year 2019/20 (up to +85 days) whereas at other sites the opposite was observed (up to -85 days). Other frost weathering-related indicators (diurnal freeze-thaw cycles, frost-cracking window) show also large intersite and interannual differences.</p><p>Our study shows that the thermal regime at a triangle-shaped moderately steep pyramidal peak is very heterogeneous between different aspects and landforms (ridge/flank/summit) and between two monitoring years confirming earlier monitoring and modelling results. Due to high intersite and interannual variabilities, temperature-related processes such as frost-weathering can vary largely between neighbouring sites. Our study highlights the need for systematic and long-term ground temperature monitoring in alpine terrain to improve the understanding of small- to medium-scale temperature variabilities.</p>


2020 ◽  
Vol 200 ◽  
pp. 02009
Author(s):  
Muhammad Nur Fajri Alfata ◽  
Amalia Nurjannah

Ground cooling is considered to be one of the passive cooling strategies in buildings although its application is rarely found in Indonesia. Effectiveness of this strategy depend on the ground temperature profiles. Meanwhile, comprehensive data of ground temperature as a basis of design for ground cooling are still rarely found in Indonesia. This research aims to develop the measurement devices for collecting ground temperatures data and to investigate the ground temperatures in different depths (i.e., 1m, 2m, …, 9m). For measurement, an instrumentation system was developed with the main component of Arduino Mega 2560 as microcontroller. T-type thermocouples with diameter of 0, 5mm mounted in the metal cones were used as the temperature sensor and placed at the different depths. The field measurement was conducted from August to November 2019 in Bandung, West Java, Indonesia. This study demonstrated that the developed instrument system had good performance both in measuring and data acquisition. Model equation was developed to predict the ground temperature at certain depth regardless ground materials and humidity level. The results indicated that the ground temperature significantly lower to 5m-depth. However, the reduction of the temperature after 5m was not significant; the deeper the ground, the temperature changes are negligible.


2018 ◽  
Vol 12 (6) ◽  
pp. 1957-1968 ◽  
Author(s):  
Charles J. Abolt ◽  
Michael H. Young ◽  
Adam L. Atchley ◽  
Dylan R. Harp

Abstract. The goal of this research is to constrain the influence of ice wedge polygon microtopography on near-surface ground temperatures. Ice wedge polygon microtopography is prone to rapid deformation in a changing climate, and cracking in the ice wedge depends on thermal conditions at the top of the permafrost; therefore, feedbacks between microtopography and ground temperature can shed light on the potential for future ice wedge cracking in the Arctic. We first report on a year of sub-daily ground temperature observations at 5 depths and 9 locations throughout a cluster of low-centered polygons near Prudhoe Bay, Alaska, and demonstrate that the rims become the coldest zone of the polygon during winter, due to thinner snowpack. We then calibrate a polygon-scale numerical model of coupled thermal and hydrologic processes against this dataset, achieving an RMSE of less than 1.1 ∘C between observed and simulated ground temperature. Finally, we conduct a sensitivity analysis of the model by systematically manipulating the height of the rims and the depth of the troughs and tracking the effects on ice wedge temperature. The results indicate that winter temperatures in the ice wedge are sensitive to both rim height and trough depth, but more sensitive to rim height. Rims act as preferential outlets of subsurface heat; increasing rim size decreases winter temperatures in the ice wedge. Deeper troughs lead to increased snow entrapment, promoting insulation of the ice wedge. The potential for ice wedge cracking is therefore reduced if rims are destroyed or if troughs subside, due to warmer conditions in the ice wedge. These findings can help explain the origins of secondary ice wedges in modern and ancient polygons. The findings also imply that the potential for re-establishing rims in modern thermokarst-affected terrain will be limited by reduced cracking activity in the ice wedges, even if regional air temperatures stabilize.


2012 ◽  
Vol 238 ◽  
pp. 341-345
Author(s):  
Hong Mei Li ◽  
Shu Shan Li ◽  
Wei Xie

The mechanism of crack formation on the concrete structure of gate piers during the construction period is analyzed. The temperature control and cracking prevention technique which combines surface heat preservation and the installation of expansion reinforcing bands is proposed. Based on the calculation principle of temperature fields and stress fields of concrete structures, simulated calculation analysis is conducted on the gate pier structure during the construction process by using the finite element method. The results show that the crack prevention effect of this temperature control measure is positive, and this measure has a certain reference value to similar engineering designs and constructions.