scholarly journals Determination of Optimum Position of Shear Wall in an Irregular Building for Zone III & IV

Stiffness is the property of the structure that is responsible for absorbing the external forces. For the case a multistory building, when the height of the building increases, the lateral stiffness of the building decreases. With low lateral stiffness, the building becomes more vulnerable to lateral forces like wind and earthquake. In order to prevent the structure from damage from the lateral forces, lateral stiffness is induced in the structure by means of shear walls. With the introduction of shear wall, we observe a considerable decrement in lateral displacement and increase in base shear. The resistance of lateral forces in terms of magnitude by shear wall depends on its location in the building. In this paper, a G+15 storey building is considered. The building is irregular in nature (T shaped). A comparative study is done to obtain the optimum position of shear wall in the structure. For optimization, the total length of the shear wall in the structure is kept constant. The whole modeling and analysis is done by ETABS v. 2016. The comparative study is done on the basis of base shear, storey displacement & storey drift. The above values are calculated by the dynamic approach of analysis of building subjected to seismic loading.

2014 ◽  
Vol 2014 ◽  
pp. 1-15 ◽  
Author(s):  
B. R. Jayalekshmi ◽  
H. K. Chinmayi

Conventional analyses of structures are generally carried out by assuming the base of structures to be fixed. However, the soil below foundation alters the earthquake loading and varies the lateral forces acting on structure. Therefore, it is unrealistic to analyse the structure by considering it to be fixed at base. Multistorey reinforced concrete framed buildings of different heights with and without shear wall supported on raft foundation incorporating the effect of soil flexibility are considered in present study to investigate the differences in spectral acceleration coefficient (Sa/g), base shear, and storey shear obtained following the seismic provisions of Indian standard code and European code. Study shows that the value of base shear obtained for symmetric plan building is lowest in buildings with shear wall at all the four corners.


Author(s):  
T. Paulay

The usefulness of certain walls in the structural planning of multistorey buildings
in particular has long been recognised. When external or internal walls are situated in advantageous positions they can be very efficient in resisting lateral loads originating from wind or earthquakes. In addition to the potential strength, which shear walls possess, they offer considerable lateral stiffness and thus can protect a building against non-structural damage that arises when lateral displacement or sway becomes excessive during a moderate seismic disturbance. Only in the last few years did the 
subject receive more attention and many aspects of the behaviour of shear walls are still
 being studied and evaluated. Because of necessary space limitations relevant features, which have been treated in well known publications, will be mentioned very briefly here, but reference to the appropriate source will be made. Other aspects, which are now understood a little better because of more recent research efforts, are presented in more detail. Emphasis is placed on features of behaviour relevant to loading of seismic origin rather than on design recipes.


2018 ◽  
Vol 65 ◽  
pp. 08008
Author(s):  
Syed Muhammad Bilal Haider ◽  
Zafarullah Nizamani ◽  
Chun Chieh Yip

The reinforced concrete structures, not designed for seismic conditions, amid the past earthquakes have shown us the significance of assessment of the seismic limit state of the current structures. During seismic vibrations, every structure encountered seismic loads. Seismic vibrations in high rise building structure subjects horizontal and torsional deflections which consequently develop extensive reactions in the buildings. Subsequently, horizontal stiffness can produce firmness in the high rise structures and it resists all the horizontal and torsional movements of the building. Therefore, bracing and shear wall are the mainstream strategies for reinforcing the structures against their poor seismic behaviours. It is seen before that shear wall gives higher horizontal firmness to the structure when coupled with bracing however it will be another finding that in building model, which location is most suitable for shear wall and bracing to get better horizontal stability. In this study, a 15 story residential reinforced concrete building is assessed and analyzed using building code ACI 318-14 for bracing and shear wall placed at several different locations of the building model. The technique used for analysis is Equivalent Static Method by utilizing a design tool, finite element software named ETABS. The significant parameters examined are lateral displacement, base shear, story drift, and overturning moment.


Author(s):  
Guoqiang LI ◽  
Mengde PANG ◽  
Feifei Sun ◽  
Liulian LI ◽  
Jianyun SUN

Coupled shear walls are widely used in high rise buildings, since they can not only provide efficient lateral stiffness but also behave outstanding energy dissipation ability especially for earthquake-resistance. Traditionally, the coupling beams are made of reinforced concrete, which are prone to shear failure due to low aspect ratio and greatly reduce the efficiency and ability of energy dissipation.  For overcoming the shortcoming of concrete reinforced coupling beams (RCB), an innovative steel coupling beams called two-level-yielding steel coupling beam (TYSCB) is invented to balance the demand of stiffness and energy dissipation for coupled shear walls. TYSCBs are made of two parallel steel beams with yielding at two different levels.  To verify and investigate the aseismic behaviour improvement of TYSCB-coupled shear walls, two 1/3 scale, 10-storey coupled shear wall specimens with TYSCB and RCB were tested under both gravity and lateral displacement reversals. These two specimens were designed with the same bearing capacity, thus to be easier to compare. The experimental TYSCB specimen demonstrated more robust cyclic performance. Both specimens reached 1% lateral drift, however, the TYSCB-coupled shear wall showed minimal strength degradation. Additionally, a larger amount of energy was dissipated during each test of the TYSCB specimen, compared with the RCB specimen. Based on the experimental results, design recommendations are provided.


2021 ◽  
Vol 4 (1) ◽  
pp. 16
Author(s):  
Leonardus Setia Budi Wibowo ◽  
Dermawan Zebua

Indonesia is one of the countries in the earthquake region. Therefore, it is necessary to build earthquake-resistant buildings to reduce the risk of material and life losses. Reinforced Concrete (RC) shear walls is one of effective structure element to resist earthquake forces. Applying RC shear wall can effectively reduce the displacement and story-drift of the structure. This research aims to study the effect of shear wall location in symmetric medium-rise building due to seismic loading. The symmetric medium rise-building is analyzed for earthquake force by considering two types of structural system. i.e. Frame system and Dual system. First model is open frame structural system and other three models are dual type structural system. The frame with shear walls at core and centrally placed at exterior frames showed significant reduction more than 80% lateral displacement at the top of structure.


2021 ◽  
Vol 23 (2) ◽  
pp. 167-176
Author(s):  
Sekar Mentari ◽  
Rosi Nursani

Indonesia is one of the countries that is prone to earthquakes. In addition to the dead loads, superimposed dead loads, and live loads, the design of buildings in Indonesia must be concerned with earthquake loads. Installing shear walls in the building structure as the Special Moment Frame Dual System is one of a solution to withstand earthquake loads. However, the location of shear walls must be considered, especially in buildings with horizontal irregularities. This study aims to determine the optimum location of the shear walls in a 10-storey building that has U-configuration with dynamic earthquake loads. This research is a numerical simulation ran by modelling the structure with software. To know the effect of the shear wall’s location on a building, several variations of the shear wall configuration with different positions have been conducted. It can be seen the lateral displacement of each floor and the shear force are the response structure to withstand the dynamic earthquake loads. Shear walls that are located close to the center of mass of the building are the optimum variation because the position of the shear wall is the closest to the core area of the building, which is the rotational axis of the building.


10.29007/7bqt ◽  
2018 ◽  
Author(s):  
Rutvij Kadakia ◽  
Vatsal Patel ◽  
Anshu Arya Arya

This study aims to model and study G+14 RCC building with different geometrical configurations and provision of shear wall at different location for zone IV and V. The various parameters like Lateral displacement, Storey drift, Drift ratio, Base Shear are compared for building models developed by using SAP2000 with and without shear wall. The provision of shear wall in multistoried building in zone V improved lateral load carrying capacity and also other parameters are enhanced in comparison with building in zone IV.


Earthquake is an unexpected and expensive disaster for both livelihood and economy. In the modern day construction, there has been a lot of importance to make the structure resistant against lateral loads for multi storied building. Shear walls are an option of lateral load resisting system. The Concept of designing shear wall is to provide building structure with sufficient strength and deformation capacity to sustain the demands imposed by lateral loads with adequate margin of safety. The study focuses on effect of shear wall on R.C. building at different heights. For this purpose five models of different heights 15m, 30m, 45m, 60m and 75m and with different aspect ratios of 1.33, 0.66, 0.44, 0.33 and 0.26 respectively have been considered. All the models were designed for seismic zone V. For analysis purpose response spectrum method of analysis is considered as per IS: 1893-2002. The comparative study has been done for base shear, storey displacement, storey drift and storey stiffness. Utilization of shear walls when placed at corners of the building of low aspect ratio in high rise buildings is more effective compared to the low rise buildings of higher aspect ratio, as it gives the larger base shear and lesser displacement. The storey stiffness and storey drift is greatly improved when shear wall is placed at corners of the building


2021 ◽  
Vol 49 (2) ◽  
pp. 456-462
Author(s):  
Irina Troyanovskaya ◽  
A. Zhakov ◽  
O. Grebenshchikova ◽  
S. Voinash ◽  
E. Timofeev

The discrepancy between the plow width and the tractor width leads to the asymmetry of plowing units. The geometry of the plowshare surface of the moldboard plow contributes to the generation of lateral forces on the working tool. All this leads to the imbalance of the tool and the deviation of the tractor from straight-line movement during plowing. To maintain straight-line movement, the driver has to adjust the machine every 5-10 meters, which is highly tiresome. To study the causes of lateral slips of the plowing unit, we constructed a mathematical model, which consists of the equations of controlled movement and equations of the tractor's uncontrolled shear under the action of external forces from the plow. The description of the force interaction of the drive with the ground is based on the mathematical theory of friction, taking into account anisotropy and elastic properties in contact. Based on the passive shear model, we constructed a hodograph diagram of the maximum tractor shear force from the side of the working tool. We found that the shear force reaches its maximum friction value only in the case of a translational shear, when its line of action passes through the tractor's center of gravity. In all other cases, the shift (slip) of the tractor is caused by a lower force. We formulated the features and assumptions of the model as applied to caterpillar and wheeled tractors. As a result, we found that, regardless of the direction of the lateral displacement of the plow's traction resistance, the tractor is slipped towards the plowed field. The result of the numerical experiment showed that the main reason for the slip of the wheeled plowing unit is the difference in soils along the sides of the tractor but not the deviation of the plow traction resistance.


Author(s):  
Shaikh Jafar Shaikh Ismail ◽  
L. G. Patil

In present era, there is a huge scarcity of vacant land led to the development of the high rise structures. For the construction of high rise buildings, normal R.C.C. system is not suitable. These problems can overcome by using flat slab system along with shear wall arrangements. It is very essential that the shear wall position should be appropriate in structure so as to achieve the lateral stiffness and solid structure against lateral loads. In this work, two main factors i.e. with drop panels and without drop panels have been considered for 12 storey structures. In each factor 5 models of various locations of shear wall is taken for consideration. For stabilization of variable parameters such as storey displacement, storey stiffness and storey shear etc the seismic investigation & design of structures had carried out in software ETABS. After performing seismic investigation & design of all the structures, result shows that if we provide shear wall at incorrect or inappropriate locations then it will only increase the dead load and cost of the structure. So the final outcomes we have achieved is to provide shear walls at desired position where lateral loads are more predominantly acting on the structures


Sign in / Sign up

Export Citation Format

Share Document