Regression Analysis on Bonding Test of Polypropylene Fiber

2014 ◽  
Vol 638-640 ◽  
pp. 1378-1382
Author(s):  
Wei Hong Xuan ◽  
Yan Wang ◽  
Yu Zhi Chen

Base on the data that gained from pullout test of Polypropylene fiber, multi-factor regression analysis considering water cement ratio and age of cement matrix, length and angle of embedded fiber was carried out. Then, a practical function of pullout force-displacement was proposed, which is well agreed with the test results.

2012 ◽  
Vol 166-169 ◽  
pp. 1521-1525
Author(s):  
Hui Wang ◽  
Ai Liang Zhai

By experimental, study on the elastic modulus and the splitting tensile strength together with the influence of the splitting tensile strength with different water-cement ratio, sand rate and water quantity , and the relational formula between the splitting tensile strength and the elastic modulus was summarized by regression analysis.


2021 ◽  
Vol 283 ◽  
pp. 01016
Author(s):  
Wei Li

In this paper, the main strength of the relationship between water-cement ratio and concrete, and it uses the contrast test of different water cement ratio, finally, it gets the regular change between water cement ratio and concrete strength. The test results show that: cement. when the ratio of large stone: small stone: water: admixture is 340: 618: 1009: 433: 139: 6.8, the water-cement ratio of concrete is within the range of 0.371-0.479. The concrete strength of the sample decreases with the increase of the water-cement ratio. Finally, the relationship between the concrete strength and the water-cement ratio is obtained by fitting.


2018 ◽  
Vol 382 ◽  
pp. 230-234
Author(s):  
Ming Ju Lee ◽  
Ming Gin Lee ◽  
Yung Chih Wang ◽  
Yu Min Su ◽  
Jia Lun Deng

In order to let fresh concrete react with carbon dioxide sufficiently, the carbon dioxide was added to mixing concrete. The study used three water cement ratio (0.55, 0.65, 0.75), three CO2 pressures (0.2, 0.4, 0.6 MPa), and two CO2 concentration (50% and 100%) to make concrete samples, and observed the effect of carbon dioxide adsorption in the above parameters. Finally, the compressive strength and carbonation degree of concretes were tested after three curing time (7, 14 and 28 days). The research showed that concrete could be more efficient to absorb carbon dioxide by using this pressure method. The results found that the mixing concrete react with carbon dioxide in a short time, and shorten the initial setting time of concrete. But this method would greatly reduce the workability of concrete after mixing with carbon dioxide and it might be enhanced by water or superplasticizer. The bond of cement matrix might cut down after reacting with carbon dioxide. Based on the above, the compressive strength of concrete which was mixed with carbon dioxide would be impaired. The proposed CO2-mixing method has the capacity to uptake 9.5% carbon dioxide based on water cement ratio and CO2 pressure.


2011 ◽  
Vol 243-249 ◽  
pp. 1179-1185
Author(s):  
Jing Fu Kang ◽  
Chun Xia Yan

This research investigated the influences of rubber content and water-cement ratio on the compressive strength of roller compacted rubberized concrete (RCR). The mix design of RCR was made by replacing same volume of sand with rubber chips based on the control concrete mix. Four rubber contents (50 kg/m3, 80 kg/m3, 100 kg/m3 and 120 kg/m3) and six water-cement ratios (0.30, 0.35, 0.40, 0.45, 0.50 and 0.55) were used. The specimen cubes were tested in compression at 28d with the load continuously and automatically measured until failure. Test results show that RCR exhibits low compressive strength but a ductile and plastic failure mode, the more the rubber used, the more the compressive strength reduced and the larger toughness obtained. Same as normal concrete, the compressive strength of RCR is also directly related to the water-cement ratio,the smaller the water-cement ratio, the higher the compressive strength. Based on the experimental results, a strength formula was developed to estimate the strength of RCR as a function of the cement strength, water-cement ratio and the rubber content.


Materials ◽  
2020 ◽  
Vol 13 (2) ◽  
pp. 321 ◽  
Author(s):  
Haitang Zhu ◽  
Chengcheng Wen ◽  
Zhanqiao Wang ◽  
Lan Li

Pervious concrete is considered to be porous concrete because of its pore structure and excellent permeability. In general, larger porosity will increase the permeability coefficient, but will significantly decrease the compressive strength. The effects of water-cement ratio, fiber types, and fiber content on the permeability coefficient, porosity, compressive strength, and flexural strength were investigated. The pore tortuosity of the pervious concrete was determined by volumetric analysis and two-dimensional cross-sectional image analysis. The concept and calculation method of porosity tortuosity were further proposed. Results show that the permeability coefficient of the pervious concrete is the most suitable with a water-cement ratio of 0.30; the water permeability of the pervious concrete is influenced by fiber diameter. The permeability coefficient of pervious concrete with polypropylene thick fiber (PPTF) is greater than that with copper coated steel fiber (CCF) and the polypropylene fiber (PPF). The permeability coefficient is related to tortuosity and porosity, but when porosity is the same, the permeability coefficient may be different. Finally, general relations between the permeability coefficient and porosity tortuosity are constructed.


Materials ◽  
2019 ◽  
Vol 12 (7) ◽  
pp. 1125 ◽  
Author(s):  
Ruohong Zhao ◽  
Yubin Weng ◽  
Christopher Tuan ◽  
An Xu

Ionically-conductive mortar can be used for indoor radiant heating partition walls. In these applications, mortar blocks are soaked in electrolyte solutions of CuSO4. The surfaces of the block are coated with sealant and epoxy resin afterwards to prevent evaporation. The mortar block becomes a heating element due to ionic conduction if a voltage is applied to the electrodes in the block. Its electrical conductivity depends on the dispersion of the electrolyte, and hence on the porosity of the mortar. The test specimens in this study were divided into four groups according to the different air entrainment agents, including aluminum powder and hydrogen peroxide as well as two air-entraining agents, SJ-2 and K12. Each group was manufactured with water/cement ratios in the range of 0.5 to 0.9. The test results showed that the conductivity of the mortar was strongly influenced by the air-entrainment and the water cement ratios. The volumetric electric resistivity and the associated microstructures of the mortar were investigated. The test results showed that the specimens made with aluminum powder and a water–cement ratio of 0.65–0.75 had high porosity. The porosity of those specimens was further increased by adding two different air-entraining agents. The specimens with aluminum powder and SJ-2, along with a water–cement ratio of 0.7 appeared to be the optimum mixture. Its resistivity was 19.37 Ω·m at 28 days under 25.31% porosity. The experimental results indicate that an ionically-conductive mortar can be produced by combining different air-entrainment agents with variable water-cement ratios to meet a specified electrical heating requirement.


2015 ◽  
Vol 9 (1) ◽  
pp. 627-630
Author(s):  
Yong Feng

PS silt mixed soil is a high quality synthetic fill material made of foam material and sludge wasted. This paper indicates according to the test results and the previous studies that: the intensity of light-weight soils is increasing as the grey water ratio increases, and when the gray water ratio reaches a certain value, the strength of the growth rate is not large. Therefore, the research of the relationship of its strength and water-cement ratio for providing accurate design parameters of soil particles lightweight soil is very important. According to existing research results, a number of samples were made to study the relationship between strength and water-cement ratio, then the analyzed curves were obtained. In this paper, based on the gray Verhulst model, the variation regulation between the strength and water ratio was fitted. The study showed that the fitted curve was similar with the measured curve. It is found that the measured curves can be derived from fitted curve available, the related research can give good references for construction of EPS silt light-weight soil.


2020 ◽  
Author(s):  
Mahyar Ramezani

Recently, Carbon Nanotubes (CNTs) are drawing considerable attention of researchers for reinforcing cementitious materials due to their excellent mechanical properties and high aspect ratio (length-to-diameter ratio). However, CNTs might not disperse well within the cement matrix, resulting in little improvement or even degradation of concrete properties. The uncertainty in producing the consistent results in different studies might be attributed to multiple interactions between the experimental variables affecting the nanotube dispersion and the final properties of CNT-cement nanocomposites. Therefore, this research mainly focused on proposing equations that can reliably capture these interactions in order to correlate CNT dispersion with the mechanical properties. The main experimental variables studied included CNT concentration, aspect ratio, ultrasonication energy, ultrasonication amplitude, surfactant-to-CNTs ratio, water-to-cement ratio, sand-to-cement ratio, and hydration age of specimen. The study reported in this research was conducted in two parts: experimental program and modeling. In the experimental part of this research, a total of 63 different mix proportions were used to evaluate the flowability, mechanical properties, and durability characteristics of cement pastes and mortars containing CNTs. Using experimental test results reported in this study and the literature, three critical relations were proposed to consider the CNT dispersion, cement matrix composition, and hydration age of cement. The proposed critical relations were then added to available theoretical models in the literature. The flexural strength and elastic modulus of CNT-cement nanocomposites were predicted through a state-of-the-art probabilistic model using a Bayesian methodology. Finally, the developed probabilistic models were used to identify the optimum ranges of the experimental variables to maximize the mechanical properties. This was done through computing the conditional probability of not meeting the specified design requirement. The experimental results indicated that addition of CNTs could significantly improve different properties of cementitious materials, if the optimum range of each variable was used. Also, to achieve the desired mechanical properties, various combinations of the experimental variables might be used. The proposed prediction models were shown to capture the interactions between the experimental variables for predicting the mechanical properties within ±15% and ±18% of the experimental test results for flexural strength and elastic modulus, respectively. Based on the findings of this research, contour plots were developed to provide practical guidelines for future engineers to design CNT-cement nanocomposites.


2014 ◽  
Vol 893 ◽  
pp. 602-605
Author(s):  
Yang Zhou ◽  
Jian Jun Shi ◽  
Quan Liu ◽  
Jian Xin Li

Yield stress and plastic viscosity are two basic parameters to describe the rheological characteristics of self-compacting concrete which would reflect the workability of self-compacting concrete quantificationally, the relationship between workability test results and rheological parameters was summarized, and the influence of superplasticizer and water cement ratio on rheological characteristics and of self-compacting concrete was studied by series experiments, the optimum water cement ratio and mixing amount of superplasticizer was proposed, this would guide the design and application of self-compacting concrete.


The presented research focuses on the experimental investigation to calculate the suitability of using recycled brick ballast obtained as demolition debris to serve as partial substitute to coarse aggregates for concrete of different grades like M10, M15, M20, M25 and by varying the product mix in different replacement proportions as 0%, 25%, 50%, 75% and 100% by weight. The proposed methodology is based on a series of tests carried out, focusing mainly on the workability and characteristic strength analysis of concrete with graded brick ballast and comparing them with the conventional cement concrete. The experimental work included several types of concrete made keeping the water-cement ratio as 0.45 and with target slump value 70-100 mm. The influence of replacing different percentages of coarse aggregates to produce different concrete grades was closely observed. The conclusion drawn from the test results conforms, the possibility to use brick ballast in concrete for M25 grade with 25% by weight of the coarse aggregate as optimum value.


Sign in / Sign up

Export Citation Format

Share Document